| 1 | L1₹31.1 LAccepted-AOC | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹33.9 L+₹1.4 L (4.29%)Rejected-Finance | L2 | Rejected-Finance Second Lowest | |
| 3 | L3₹34.7 L+₹2.2 L (6.72%)Rejected-Finance | L3 | Rejected-Finance Third Lowest | |
| 4 | L4₹39.0 L+₹6.4 L (19.8%)Rejected-Finance | L4 | Rejected-Finance Fourth Lowest |
Tender Value
Refer Docs
EMD Value
₹74,560
Closing Date
29 Jul 2022, 6:00 pmClosed
Major Sameer Wadekar
Holta Cantt Palampur
SPECIAL REPAIRS TO BLDG NO P-4MH IN A AREA AND OTHER SANCTIONED WORK AT ALHILAL MIL STN
2022_MES_535172_1
GEP-12/2022-23
Open Tender
Civil Works
Item Rate
180 days
Alhilal Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹74,560
Yes
26 Aug 2022
1 Jul 2022
1 Aug 2022
1 Jul 2022
29 Jul 2022
15 Jul 2022
Amount
Schedule 'A' Part-I:- Dismantling old plain or corrugated rusted steel sheeting, any gauge and thickness in roof covering including Nainital or similar pattern roof coverings, complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, compete all as specified and directed. (Colour as approved by GE)
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, compete all as specified and directed. (Colour as approved by GE)
Dismantling timber scantlings 40Sq.cm and over in section, in any position complete all as specified and directed.
S&F mild steel roof trusses (framed), trussed, purlins, crane gantries. rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, Fe 410-W (Grade E-250) complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
Excavation post holes (or similar holes) in any type of soil each n exc 0.50 cu.m,getting out,returning,filling on and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25cm, complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in mass concrete complete all as specified and directed.
M&L preparing new surface of steel of any description, over 10cm width or girth not other wise described and appliying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer, complete all as specified and directed.
Dismantling of wall & ceiling boards (fiber, pulp, insulation etc) or insulation boards /slabs /blankets any thickness, including cover fillets complete all as specified and directed.
S&F anodised aluminium snap grid frame work 605mm x 605mm for false ceiling including hangers 6mm dia GI(upto1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of G.I. flat iron of size 40mm X 3 mm, 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
M&L 8mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid (Frame work for ceiling shall be measured and paid separately).
Demolition of brickwork or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work precast concrete articles complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in Cement mortar 1:6, complete all as specified and directed.
M&L walling of random rubble, un-courses, well bonded bedded & solidly hearted built in cement mortar 1:6, complete all as specified and directed.
Demolition of floor, hearth or wall tiling including cement mortar bedding or backing coat, removing rubbish off the premises, removal and depositing where directed and leaving the work clear of any plastering complete all as specified and directed.
M&L Non-skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L Non-skid coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm as in floors etc laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L Non-skid, coloured ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but not exc 0.38 sqm cut to size as required as in skirting/dado over and including 10mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B-0 (12.5mm graded stone aggregate) 25mm thick as in sub base of flooring, leveling course of flooring or levelling course of roof etc, complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors, kota stone, granite flooring, tiles flooring and paving's not exceeding 15cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed.
M&L plain cement concrete,1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in surface channels or drains etc, complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed.(inner girth only measured)
M&L 50 mm thick PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate laid in alternative bays area not exc 2 sqm each as in plinth protection laid to slope of 1 in 12 including finishing the surface even & fair & filling the joints (6 mm wide) with mastic filling i.e one part of bitumen 85/25 or VG-30 and 3 parts of sand by weight complete all as specified & directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed.
M&L rendering 15mm thick plaster in cement mortar(1:4) on brick/stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing, finished even and smooth without suing extra cement complete all as specified and directed.
M&L rendering 15mm thick plaster in cement mortar(1:6) on brick/stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing, finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of Oil bound distemper, of approved tinted over and including plaster of paris putty of 1mm thick to prepare the surface even and smooth complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paints having VOC content less than 50 gms/litre, and UV resistance as per IS 15489-2004,alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additived @1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.90litre/10 sqm on new surface complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.50 Sqm and not exceeding 4 Sqm each, complete all as specified and directed.
S&F pressed steel frames of size 165mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer,complete all as specified and directed.
S&F Pressed steel frames of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer, complete all as specified and directed.
S&F rolled mild steel bands,straps,supports or stays for rainwater,ventilating pipes,including bolts,if required; hooks(stays),heavy,for large gates,hook and pintle hinges;large hasps and staples;chains;hand made sliding bolts; clamps; hold fasts; wall ties;hooks for hanging fans; plain angle cleats for securing purlines to wooder trusses conform to Fe-290 Gde E-165 complete all as specified & directed.
M&L plain cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate cast in situ in lintels up to 1.5 m clear span, cills steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, back side filling of steel chowkats or frames, kneelers, apex stones (fixing hold fasts), bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straight or curved) complete all as specified & directed.
S&F 35mm thick factory made 2nd class hard wood rail and style plain framed, panelled shutter with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS:1003 (part 1) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35mm thick, 2nd class hard wood, factory made, glazed & skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. Sizes of members of shutters as specified in SSR Part I, Section 8, Clause 8.24 (a) complete all as specified and directed.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
M&L preparation of new wooden surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc. 0.5 sq.m in each pane complete all as specified and as directed.
S&F box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thick MS tube factory made with double side shutters wire gauged shutters & glass glazed shutter(wire and glass panes shall be measured and paid separately) with side hung shutters with steel handles and steel peg stay doytailed at welded incl 2 Nos tower bolts 150 mm long for each leaf and 8 mm square bar grills at spacing as shown on drg welded to FI frame work,incl other fittings,hinges,handles tarred hold fast PCC blocks etc. all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 ,complete all as specified.
S&F rolled mild steel sections like angle, channel, flat etc as inframed work such as grills, gratings,etc,with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders ; framed balusters; walk ways; railings; framed work of water tanks and similar work confirming toFe-290Gde E-165 complete all as specified & directed by Engineer-in-charge.
S&F 100 mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
S&F 150 mm size (length of bolt) aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F aluminium handles, cast type, anodised of size 150 mm long, complete all as specified and directed.
S&F 300 mm size (length of bolt) aluminium alloy, anodised, sliding door bolt with hasp and staple ,(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F well seasoned 2nd class hard wood small fitting such as cleats, brackets of any type,latch and hinge blocks,shaped door and windew stops and the like including all necessary labours articles n.exc 200 Cu.cm each complete all as specified and as directed.
S&F in repairs PVC coated mild steel conduit pipe 25mm dia (Drapery rod) with PVC coated MS clamps to hold drapary rod and decorative attachment at one or both ends of drapary rod complete all as specified & directed.
Excavation in trenches,nexc 1.50m wide and n exc 1.50m in depth for foundation,etc or for shafts, wells, cesspits, manholes,pier holes,etc n exc 10 sq m on plan and getting out any type of soil complete all as specified and directed. (Exavation by mechanical means)
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30cm thick; watering, ramming/rolling and finishing to required size, shape, etc, n exc. 1.5m high from base complete all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30cm thick; watering, ramming/rolling and finishing to required size, shape, etc, exc. 1.5m but not n exc. 3m high from base complete all as specified and directed.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30cm thick; watering, ramming/rolling and finishing to required size, shape, etc, exc. 3m but not n exc. 4.50m high from base complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L M-25 (design mix) using 20mm graded crushed stone aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns etc; basement slabs, under-reamed plies and mass concrete complete all as specified and directed.
M&L M-25 (design mix) using 20mm graded crushed stone aggregate in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed.
Formwork to sides of rough finished flat surfaces of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Formwork to sides of rough finished flat surfaces of concrete to face of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc; vertical or to batter complete all as specified and directed.
Supply only PVC (SWR) pipes 110mm bore low density of pressure rating 10 Kg/sqcm for weep holes of RCC retaining wall complete all as specified and directed.
Returning, filling in (soil ) including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified.
S&F wire netting of galvanised steel wire 1.40mm dia and 12mm size mesh fixed with tinned tacks of wire staples complete all as specified and directed.
Supply only 20mm graded stone aggregate for weep holes complete all as specified and directed.
Schedule 'A' Part-II:- Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc . removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
M&L point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS-H cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including concealed PVC rigid conduit with accessories fixed wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box (with earth dolly) duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally. and two coats of black bituminous paint over a coat of red oxide primer externally,covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly for One light/ fan/ Exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and directed.
All as per the description of Serial item No. 64 above but one 5 pin socket outlet, 6 Amp on independent board complete all as specified and directed.
All as per the description of Serial item No. 64 above but one 5 pin socket outlet, 6 Amp on the same board complete all as specified and directed.
All as per the description of Serial item No. 64 above but for 16 Amps socket point on independent board with 2.5 Sqmm PVC insulated FRLS-H multi-stranded copper conductor with 2.5 Sqmm PVC insulated FRLS-H multi-stranded copper conductor as earth wire,complete all as specified and directed.
S&F switch piano 6 Amp flush type single pole one way with ISI marked,complete all as specified and directed.
S&F switch piano 16 Amp flush type single pole one way with ISI marked,complete all as specified and directed.
S&F socket outlets 2-in-1, 3 pin 6 Amp flush type, complete all as specified and directed.
S&F socket outlets 6 and 16 Amps 2-in-1, 5 pin flush type, complete all as specified and directed.
Supply and fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required complete all as specified and directed.
S&F Ceiling rose, 3 phase / PVC / Polycarbonate, isolated bodycomplete all as specified and directed.
Taking down of sub main wiring of any type and capacity with PVC casing caping / PVC surface or concealed conduit including earth wire and making good disturbed surfaces to match the existing surface, complete all as specified and directed.
M&L Wiring for circuit / sub-main wiring with approved colour coding in PVC concealed conduit alongwith 6 Sqmm earth wire with 2 x 6.0 Sqmm FRLS-H PVC insulated multi-stranded copper conductor, single core cable complete all as specified and directed. Note:- 2 run of 6 sqmm wire and 1 run of 6 Sqmm of earth wire and PVC conduit shall be measured as one run.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed.
S&F Factory made DB TPN 4 way double door with suitable size of copper bus bar concealed in wall IP 43 protection,415 V,3 phase 50 Hz for fixing MCB complete all as specified and directed.
S&F Factory made DB SPN 8 way double door with 200 Amps rated bus bar concealed in wall IP 42/43 protection,240V for fixing MCB complete all as specified and directed.
S&F MCB SP ‘B’ curve, 10KA 6 to 32 amps including necessary connection complete all as specified and directed.
S&F MCB SPN ‘C’ curve, 10KA 32 amps including necessary connection complete all as specified and directed.
S&F MCB TPN ‘B’ curve, 10KA 32 amps including necessary connection complete all as specified and directed.
S&F 1x 20 watt 4 feet long LED tube light fitting box type with compact commercial batten suitable for single T8 LED tube 4 feet long and polycarbonate T8 tube with in built driver with metal head sink double sided connection complete all as specified and directed. ( CG product description DMLN1LT8-16 for batten and CG product description LT8-20-865-(2) for rod or equivalent make as approved by GE)
S&F in repairs LED bulk head fittings IP-65 protection class with LED lamp 10 watt complete all as specified and directed. (Bajaj cat part No: BIBWP 10W LED or equivalent make as approved by GE)
Hanging only ceiling fan and connecting up including privision of cable from ceiling rose or connector to fan complete all as specified and directed. Note: Fan obtained from taking down will be refixed in this item.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades for proper cleaning complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode of size 600x600x6mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with top edge of the plate not less than 1.5 mtr below ground level and connected to galvanised iron earth lead wire 4mm (8 SWG) dia by means GI nuts, bolts & washers including PCC pit (1:2:4) type B 1 pre cast RCC cover slab of size 550 x 550 x 75mm thick using reinforcement with XPM weighting not less than 1.8 Kgs / sqmm with suitable handle, made of 12 mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with case iton funnel and wire mesh, 15mm bore light grade galvanised steel tubing upto 5 M length for drawing earth lead wire protection, common salt, charcoal etc complete all as shown in EP No 3 of SSR Part I and testing on completion.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 mtr in depth for foundation laying of under ground cable erecting of pole stay not exc 10 sqm on plain and not exc 1.5 m depth and getting out in any type of soil complete all as specified.
Returning, filling in (soil ) including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified.
Removal of excavated material (soil) to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified.
Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
Sub class “B” brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal, to length of the brick, complete all as specified and directed.
Material and labour for GI tubing (light grade) with all fitting laid in trenches or along pole/bldg or under road crossing and protection pipe or fixed alongwith wall/pole with necessary clamp nut bolt and washer bore of pipe 40mm complete all as specified.
Taking down unservicible U/G cable after disconnecting from pole and Supply & laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16sqmm, 4 core complete all as specified.
M/S THAKUR ENTERPRISES
VIVEKA ENTERPRISES
M/S Bharmouri Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .