Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC 6 RAMESHWAR COMPLEX OPP OSCAR CITY SADHU VASVANI ROAD RAJKOT 360007 | RAJKOT | GUJARAT | 360007 | L1 | Accepted-AOC Meeting NIT criteria | |
| 2 | L2₹19.6 L+₹61,347 (3.23%)Rejected-Finance 18 EMPIRE HOUSE RANG UPVANSOCIETY SARDARPATEL COLONY SIX ROAD CIRCLE NAVRANGPURA AHMDABAD GUJARAT 380014 | AHMADABAD | GUJARAT | 380014 | L2 | Rejected-Finance Meeting NIT criteria | |
| 3 | L3₹21.8 L+₹2.8 L (14.8%)Rejected-Finance D S 185 186 SECTOR D LDA COLONY KANPUR ROAD LUCKNOW LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L3 | Rejected-Finance Meeting NIT criteria | |
| 4 | L4₹21.9 L+₹2.9 L (15.1%)Rejected-Finance A 86 MANISH MARG NEMI NAGAR VAISHALI NAGAR JAIPUR JAIPUR JAIPUR RAJASTHAN 302021 | JAIPUR | RAJASTHAN | 302021 | L4 | Rejected-Finance Meeting NIT criteria | |
| 5 | L5₹22.8 L+₹3.8 L (20.0%)Rejected-Finance 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | L5 | Rejected-Finance Meeting NIT criteria |
Tender Value
₹25.3 L
EMD Value
₹50,572
Closing Date
23 Feb 2022, 5:00 pmClosed
Sh J S Deshmukh SM (E-E)
Elect. Engg. Office, Rajkot Airport, Rajkot
Replacement of AC units at C.A. Rajkot.
2022_AAI_103960_1
AAI/RAJ/SM (E-E)/NIT-09/21-22
Open Tender
Electrical Works
Works
90 days
Rajkot
As per NIT
15 documents required · 15 mandatory
₹1,180
Yes
₹50,572
Yes
17 Mar 2022
2 Feb 2022
24 Feb 2022
2 Feb 2022
23 Feb 2022
2 Feb 2022
2 Feb 2022 - 22 Feb 2022
Amount
SITC of inverter split-type air conditioning unit of the following capacity with 5-star BEE-rating conforming to IS : 1391 (Part-2) - 1992 with latest Amendments fitted with scroll/rotary compressor operating on eco- friendly refrigerant suitable for wall mounting for 230 V, 50 Hz single phase AC supply; capable of performing the functions as cooling, dehumidifying, air circulating and filtering, remote control operation for temparature adjustment; complete with compressor, evaporators, air cool condenser (copper), copper piping (Minimum 3 Mtr.) with Nitrile rubber insulation, copper cable as per OEM recommendation (minimum 3 mtr), including suitable heavy duty M.S.Stand for outdoor unit, Standard drain pipe, including all accessories etc. as per technical specification and as per site requirement as per attached approved make list. 1.5 TR split-type AC
SITC of inverter split-type air conditioning unit of the following capacity with 5-star BEE-rating conforming to IS : 1391 (Part-2) - 1992 with latest Amendments fitted with scroll/rotary compressor operating on eco- friendly refrigerant suitable for wall mounting for 230 V, 50 Hz single phase AC supply; capable of performing the functions as cooling, dehumidifying, air circulating and filtering, remote control operation for temparature adjustment; complete with compressor, evaporators, air cool condenser (copper), copper piping (Minimum 3 Mtr.) with Nitrile rubber insulation, copper cable as per OEM recommendation (minimum 3 mtr), including suitable heavy duty M.S.Stand for outdoor unit, Standard drain pipe, including all accessories etc. as per technical specification and as per site requirement as per attached approved make list. 2 TR split-type AC
SITC of ceiling-mounted casette-type air conditioning unit of the 4 TR capacity conforming to with latest Amendments fitted with rotary/scroll compressor operating on eco- friendly refrigerent, LED Display, with remote control, auto restart, independent dehumidification, air flow direction control, low voltage start up & suitable to operate on 415 V (+/- 10%), 50Hz, 3 phase power supply etc. complete with M/S stand for outdoor unit and all standard accessories etc. as per site requirement.
Dismantling of old AC units (up to 3 TR) including indoor unit, outdoor unit, piping and all necessary connections i/c. painting putty, wall hole finishing etc. complete as per site requirement and safely hading over to AAI store.
Providing & fixing extra refrigerant copper piping with Nitrile rubber insulation and copper cabling (2.5 sq.mm.) between indoor and outdoor units of split-type AC units (Upto 2 TR) etc. as required.
Providing & fixing extra refrigerant copper piping with Nitrile rubber insulation and copper cabling for power (2.5 sq.mm.) and communication (1.5sq.mm) between indoor and outdoor units of casette AC units etc. as required.
Supplying and drawing 5 C X 4 sqmm of FRLS PVC insulated copper conductor cable in the existing surface / recessed steel / PVC conduit / Casing Caping etc. as required.
Supplying and fixing of 25 mm dia medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Providing and fixing of 20mm inner dia CPVC drain pipe for drain water for AC and wastage water of water cooler unit to nearest drain point including CPVC Elbow , CPVC Coupler, Reducer, solvent, clamp, net packing at end etc. as per site requirement.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Replacement of Aluminium condensers with copper condensers of existing split-AC units with following capacities; including dismantling, discharging, vaccuming, pressurized N2 testing for leaks, recharging with an eco- friendly refrigerant and reinstallation at different location (with outdoor unit) as instructed by EIC; complete as per site requirement. [Copper piping will be executed at per item no. 5 as per site requirement] 1.5 / 2.0 Ton Split type AC
Supply and installation of 4 KVA rating automatic voltage stabilizer suitable for operation on 170V-280V, input single phase, AC power Supply with high/low voltage cut of time delay with output voltage of 220V+9% including cable leads confirming to IS-specification etc. as required.
Supply and installation of 5 KVA rating automatic voltage stabilizer suitable for operation on 170V-280V, input single phase, AC power Supply with high/low voltage cut of time delay with output voltage of 220V+9% including cable leads confirming to IS-specification etc. as required.
Empire Airconditioning Pvt Ltd
Anoop Refrigeration
LIFE STYLE INTERIORS
Techno Electricals
M/s. PRANAM HVAC ENGINEERING PVT. LTD.
CIS GLOBAL INFRATECH PRIVATE LIMITED
Shanti Structure Pvt Ltd
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .