Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹95.2 L
EMD Value
₹95,205
Closing Date
31 Jul 2026, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Officer NA,GIDC, Ankleshwar
ARC for Operation, Maintenances and Repairing of Street light for Industrial and Housing Area at Notified, Area, GIDC, Ankleshwar for Zone-2
326585
01 of 2026-2027. Tender Sr. No. 04.
Open
Electrical and Maintenance Works
Works
Bharuch
20 documents required · 20 mandatory
₹2,832
Chief Officer, Notified Area, Ankleshwar
₹95,205
22 Jul 2026
22 Jul 2026
22 Jul 2026
31 Jul 2026
22 Jul 2026
120 days
Name of Work: ARC for Operation, Maintenances and Repairing of Street light for Industrial and Housing Area at
Notified, Area, GIDC, Ankleshwar for Zone-2.
Sr. No. Item Description Qty. Rate Unit Amount
Annual Rate contract for Operation & Maintenance of
street light of Notified Area, GIDC, Ankleshwar
(Industrial Zone). The Scope includes to maintain the
street light through out the contract period, this
includes labour plus material like replacement of
chocks, starter, holders, capacitors, ignitor, LED
Driver, PCB etc. in sodium/MH fittings and LED
Fittings. The quantites are as mentioned below. The
agency has to provide sufficient wiremans, helpers &
required labours for the alloted zone this gange also
be draw the ladder. The agency has to provide Bike or
two Wheeler to the each teams. The agency has to
maintain average 90% of the street lights during the
month. The payment shall be made on efficiency Per pole /
basis. If any lamps or accessaries required to be Month
replace in the above scope, the same shall be use of
approved brand only. The scope includes to the trim
the trees soruounded to the lamp fittings as and when
reqired. The agency has to carried out the work as per
direction of Engineer In-charge & as per the detailed
scope of work given in the tender. For the weekly
checking of the street light efficiency, the agency has
to arrange the vehiclal for the engineer either bike or
rekshaw as & when required or called. The Agency
Have to Provide Hydraulic Ladder (Tractor or
Vehical mounted) for Minimum 13 meter height from
Ground Level for Repairing of Any street Light Fitting.
(A) Sodium Fixtures 400 W
(B) Sodium Fixtures 250 W 9252 171.11 Month
(C) Sodium Fixtures 150 W 6132 140.98 Month
(E) 50-80 W LED Street Light Fixture 3528 79.39 Month
(F) 90-100 W LED Street Light Fixture 5952 112.41 Month
(G) 120-150 W LED Street Light/Flood Light Fixture 3336 162.11 Month
(H) 250 W LED Street Light/Flood Light Fixture 144 178.69 Month
(I) 400 W LED Flood Light Fixture 192 278.22 Month
Total Rs. Of Part A
Providing and erecting XLPE (IS:7098)(I)-88 ISI
marked armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing cable trench / pipe at
road crossing or floor of following size of cables --
Supplying & erecting XLPE(IS:7098) (I)-88 ISI
unarmoured Aluminium cable 1.1 KV.grade to be
erected as directed of following size -- 2 core 6 Sq.
Supplying & erecting XLPE(IS:7098)(I)-88 ISI
3 unarmoured copper cable 1.1 KV grade to be erected 1500 137.36 Meter
as directed of following size. 3 Core 2.5 Sq.mm
Making trench in soft soil of suitable width of 90 cms
deep for laying cable or locating the fault all over the
run and backfilling the same and making the surface
as normal ground. Up to 25 mm2 Cable
Making trench in hard murrum/Tar Road of suitable
width of 90 cm or required depth for laying any size of
cable or locating the fault all over the run and back
filling the same and making the surface as normal
ground. If Additional machinery like hammer driller or
Drilling the road without breaking the road surface
(Asphalt) for laying of cable for feeding power supply
by making upto 150mm dia. size of holes at both ends
Supply & erection Sintex or approved make SMC
press moulded composite FRP (Plastic) loop-in, loop-
out box approximate 2.07 mm thick comp. With
bakelite connector strip 8 way & hinged door having
locking with mounting clamps with nuts, bolts, &
washers suitable for erecting on pole with cable
clamps and earth bolt of following size of box.
Including kit kat pattern porcelain fuse bridge 15/16A
per way and neutral bar connector Complete 300mm
x 200mm x 100mm [deep]
Providing & laying. Double walled corrugated pipes
(DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at
8 required depth for laying of cable. below ground / 4000 62.62 mtr
road surface for enclosing cable and back filling the
same to make ground as per original. 50 mm outer
Providing & laying approved make ISI marked HDPE
Kg/cm2 (class-3) as per IS:4984:1995 PE-80 to be
9 erected at road crossing on or floor as directed for 150 249.47 mtr
laying of cable. The pipes as following size of dia &
weight per 6 mtr. 63 mm inner dia.
Disconnecting the cable connection and Providing
Straight Joint with PVC mould using heat shrink/cast
resin type epoxy compound insulating material and
10 making the joint complete using necessary in line 100 1083.73 Nos
connectors, spacers etc. and reconnecting the same &
ensure the joint resistance within the limits as per IS.
Up to 25 Sq.mm Cable.
Hiring of tractor with Trolley, driver, diesel etc only for
minimum 8 hr working per day.
Supplying and erecting approved make Octagonal
Pole made from HR sheet steel. The pole should be
made as per IS. And Shall be coated with hot dip
galvanizing as per IS 2629/2633/4759, suitable
suspended local wind speed with integral Junction box
consist of terminal plate of min 6 mm hylam sheet,
standard profile 35mmX7.5 mm Din-Rail for MCB
Mounting, Stud type terminal and Arrangement for
cable termination to be erected on foundation as per
details given by manufacturers considering site
requirement. (A) 8 Mtr. Long 70 mm Top X
mm bottom dia, 3 mm thickness with 260 mm X
260mm X 16 mm Base plate, 4-M20 bolts and
mm long J- Bolt.Approx pole weight 84 Kg.
Supplying and erecting approved make Octagonal
Pole made from HR sheet steel. The pole should be
made as per IS. And Shall be coated with hot dip
galvanizing as per IS 2629/2633/4759, suitable
suspended local wind speed with integral Junction box
consist of terminal plate of min 6 mm hylam sheet,
standard profile 35mmX7.5 mm Din-Rail for MCB
Mounting, Stud type terminal and Arrangement for
cable termination to be erected on foundation as per
details given by manufacturers considering site
requirement. (B) 10 Mtr. Long 70 mm Top X
mm bottom dia, 4 mm thickness with 275 mm X
275mm X 16 mm Base plate, 4-M20 bolts and
mm long J- Bolt. Approx Pole Weight 145 KG
Providing and erecting Street Light pole bracket
comprising main B Class GI pipe of 4.2 cm/require
outside dia. complete with suitable B Class GI sleeve
tubing of approx. 45cms.length and suitable for
mm /80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
1.5.mtr. length with 110 deg.with vertical plane &
suitable welded stays, reducer and with check nuts
complete painted with one coat of Red oxide / PU base
primer and two coats of Aluminium / PU paint. paint
with following nos of arms.(A) Decorative Single Arm
Bracket 1.5 meter
Providing and erecting Street Light pole bracket
comprising main B Class GI pipe of 4.2 cm/require
outside dia. complete with suitable B Class GI sleeve
tubing of approx. 45cms.length and suitable for
mm /80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
1.5.mtr. length with 110 deg.with vertical plane &
suitable welded stays, reducer and with check nuts
complete painted with one coat of Red oxide / PU base
primer and two coats of Aluminium / PU paint. paint
with following nos of arms.(A) Decorative Double Arm
Bracket 1.5 meter
Supplying and erecting LED Street Light/Flood Light
fittings with High Power White LEDs wattage of 1 Watt
and above assembled on single MCPCB, efficiency
more than 130lm/W and Corrossion free High
Pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminum with
diffuser and polycarbonate optics/lenses with company
mark/name engraved or embrossed 120 to 300 V,
Power factor more than .95, THD<10%, CCT 3000 K to
5700K, Uniformity ratio >0.45,Luminaire efficienacy >
100 lumens/watt. LED driver efficiency>85%
CREE/OSRAM/PHILIPS
lumilds/NICHIA/SEOUL/Bridge lux (USA) make LED
used for luminaire. ( fittings required LM-79 & LM-80
certificates) (Note: below description have show room
ranges of wattage capacity of LED fittings. The
Enginneer in charge may select any Wattage capacity
between the ranges shown.) Street Light (IP-65),
Surge protection - 4KV integral and 10KV non integral,
light must have 440VAC line supply protection. It
should with stand 48 hours for 440VAC line supply.
For above 48W to 60W LED
Supplying and erecting LED Street Light/Flood Light
fittings with High Power White LEDs wattage of 1 Watt
and above assembled on single MCPCB, efficiency
more than 130lm/W and Corrossion free High
Pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminum with
diffuser and polycarbonate optics/lenses with company
mark/name engraved or embrossed 120 to 300 V,
Power factor more than .95, THD<10%, CCT 3000 K to
5700K, Uniformity ratio >0.45,Luminaire efficienacy >
100 lumens/watt. LED driver efficiency>85%
CREE/OSRAM/PHILIPS
lumilds/NICHIA/SEOUL/Bridge lux(USA) make LED
used for luminaire. ( fittings required LM-79 & LM-80
certificates) (Note: below description have show room
ranges of wattage capacity of LED fittings. The
Enginneer in charge may select any Wattage capacity
between the ranges shown.) Street Light (IP-65),
Surge protection - 4KV integral and 10KV non integral,
light must have 440VAC line supply protection. It
should with stand 48 hours for 440VAC line supply.
For Above 60 to 90W LED
Supplying and erecting LED Street Light/Flood Light
fittings with High Power White LEDs wattage of 1 Watt
and above assembled on single MCPCB, efficiency
more than 130lm/W and Corrosion free High Pressure
die cast aluminium housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser
and polycarbonate optics/lenses with company
mark/name engraved or embrossed 120 to 300 V,
Power factor more than .95, THD<10%, CCT 3000 K to
5700K, Uniformity ratio >0.45,Luminaire efficiency >
100 lumens/watt. LED driver efficiency>85%
CREE/OSRAM/PHILIPS
lumilds/NICHIA/SEOUL/Bridge lux(USA) make LED
used for luminaire. ( fittings required LM-79 & LM-80
certificates) (Note: below description have show room
ranges of wattage capacity of LED fittings. The
Enginneer in charge may select any Wattage capacity
between the ranges shown.) Street Light (IP-65),
Surge protection - 4KV integral and 10KV non integral,
light must have 440VAC line supply protection. It
should with stand 48 hours for 440VAC line supply.
For Above 90 to 120W LED
Supplying and erecting LED Street Light/Flood Light
fittings with High Power White LEDs wattage of 1 Watt
and above assembled on single MCPCB, efficiency
more than 130lm/W and Corrossion free High
Pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminum with
diffuser and polycarbonate optics/lenses with company
mark/name engraved or embrossed 120 to 300 V,
Power factor more than .95, THD<10%, CCT 3000 K to
5700K, Uniformity ratio >0.45,Luminaire efficienacy >
100 lumens/watt. LED driver efficiency>85%
CREE/OSRAM/PHILIPS
lumilds/NICHIA/SEOUL/Bridge lux(USA) make LED
used for luminaire. ( fittings required LM-79 & LM-80
certificates) (Note: below description have show room
ranges of wattage capacity of LED fittings. The
Enginneer in charge may select any Wattage capacity
between the ranges shown.) Street Light (IP-65),
Surge protection - 4KV integral and 10KV non integral,
light must have 440VAC line supply protection. It
should with stand 48 hours for 440VAC line supply.
Supplying 120 erecting
Street Light/Flood Light
fittings with High Power White LEDs wattage of 1 Watt
and above assembled on single MCPCB, efficiency
more than 130lm/W and Corrosion free High Pressure
die cast aluminium housing with smooth finish powder
coated and heat sink extruded aluminium with diffuser
and polycarbonate optics/lenses with company
mark/name engraved or embrossed 120 to 300 V,
Power factor more than .95, THD<10%, CCT 3000 K to
5700K, Uniformity ratio >0.45,Luminaire efficiency >
100 lumens/watt. LED driver efficiency>85%
CREE/OSRAM/PHILIPS
lumilds/NICHIA/SEOUL/Bridge lux(USA) make LED
used for luminaire. ( fittings required LM-79 & LM-80
certificates) (Note: below description have show room
ranges of wattage capacity of LED fittings. The
Enginneer in charge may select any Wattage capacity
between the ranges shown.) Flood Light (IP-65),
Surge protection - 4KV integral and 10KV non integral,
light must have 440VAC line supply protection. It
should with stand 48 hours for 440VAC line supply.
For above 120 W to 160 W LED
Supplying and erecting LED Street Light/Flood Light
fittings with High Power White LEDs wattage of 1 Watt
and above assembled on single MCPCB, efficiency
more than 130lm/W and Corrossion free High
Pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminum with
diffuser and polycarbonate optics/lenses with company
mark/name engraved or embrossed 120 to 300 V,
Power factor more than .95, THD<10%, CCT 3000 K to
5700K, Uniformity ratio >0.45,Luminaire efficienacy >
100 lumens/watt. LED driver efficiency>85%
CREE/OSRAM/PHILIPS
lumilds/NICHIA/SEOUL/Bridge lux(USA) make LED
used for luminaire. ( fittings required LM-79 & LM-80
certificates) (Note: below description have show room
ranges of wattage capacity of LED fittings. The
Enginneer in charge may select any Wattage capacity
between the ranges shown.) Flood Light (IP-65),
Surge protection - 4KV integral and 10KV non integral,
light must have 440VAC line supply protection. It
should with stand 48 hours for 440VAC line supply.
For above 160 W to 200 W LED
Supplying and erecting LED Street Light/Flood Light
fittings with High Power White LEDs wattage of 1 Watt
and above assembled on single MCPCB, efficiency
more than 130lm/W and Corrossion free High
Pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminum with
diffuser and polycarbonate optics/lenses with company
mark/name engraved or embrossed 120 to 300 V,
Power factor more than .95, THD<10%, CCT 3000 K to
5700K, Uniformity ratio >0.45,Luminaire efficienacy >
100 lumens/watt. LED driver efficiency>85%
CREE/OSRAM/PHILIPS
lumilds/NICHIA/SEOUL/Bridge lux(USA) make LED
used for luminaire. ( fittings required LM-79 & LM-80
certificates) (Note: below description have show room
ranges of wattage capacity of LED fittings. The
Enginneer in charge may select any Wattage capacity
between the ranges shown.) Flood Light (IP-65),
Surge protection - 4KV integral and 10KV non integral,
light must have 440VAC line supply protection. It
should with stand 48 hours for 440VAC line supply.
For above 200 W to 250 W LED
Dismantling / Installation of Street light pole on
foundation with Bracket and light Fitting & nut bolt
system as per ISI complete manar, over all lenth of
pole 7.5 mtr to 11 mtr
Repairing of Street Light octagonal / Swage Pole by
cutting, bending, welding & paiting with same PU
colour with all material and with two time trasporation
of Pole at any location in ankleshwar GIDC Area.
S/o. Misc. Hardware like MS/GI nut Bolts, J bolts,
25 Washers , Base Plate Etc, as per Instruction Given by 100 164.27 KG
Engineer In charge.
Providing M-20 / 1:2:4 cement concrete foundation &
70 % PCC from bottom including excavation for the
pole of size 60 x 60 x 120 cms. Deep in below ground
26 level with plinth of 45 cms x 45 cms(or 45 cms dia x 45 15 1292.8 No
cms) high upper ground level with necessary curing
and finishing in approved manner. ( for 7.5 & 8/8.5 mtr
Painting & numbering of street light pole with bracket
27 complete with two coats of Aluminium paint for 250 357.54 No
following size of pole. [c] upto 9 mtr
Construction of RCC Foundation for Octagonal/GRP
28 Pole with Anchor Bolts, as Per Drawings and 35 6666.11 No
Solder less crimping type Aluminium lugs conforming
to IS Suitable for Cable of following size evenly
29 crimped with high pressure tools & connected to 1916 15.15 Ea
switchgear terminals with brass/cadmium plated nut
bolts in an approved manner. 16/25 Sq.mm.
Pipe type earthing having 150 cms.long and 2.5 cms.
dia. galvanised iron pipe with coupling and buch buried
in specially prepared earth pit complete with necessary
8 SWG earth wire.
Approved make Four Pole LT Heavy Duty Switch
Disconnector Fuse Unit Cubical type for panel
mounting complete with operating mechanism suitable
to operate on 415V A.C. With HRC fuses of suitable
load confirming to IS. 13947 (Part I & III). of following
capacities. Cat-III 125 Amp
Providing and erecting 240 V MCB double pole switch
for motor & inductive load (C curve) having 10KA
32 breaking capacity & confirms to IS: 8828 in existing 205 299.97 No
box having following capacity. A) 6 to 32 Amp. (Cat-
Supply and Installation of 10KV/10KA SPD (Surge
33 Protection Device) having input Volatge Range 120V 100 484.8 No
to 310 AC having IP-67 (Mould) Rating.
Providing & erecting GI MCB channel (Size: 1 Meter
34 (L) X 35 mm (W) DIN RAIL. Complete fitting with GI 151 58 Nos
Supply and Installation of 60A 4 way Bakelite
connector strip for Termination.
Supplying cutting, bending, binding and placing in
position steel as per plan and design and as per ISS
2502 including cost of steel and binding wire for
36 reservoirs/structures oly including lift up to 5 meter 1 69603.14 MT
height of depth below G.L. for all diameters. High yeild
strength deformed(HYSD)bars/cold twisted deformed
(CTD) bars confirming to IS1786(latest)FE-415
Providing and casting in situ CC in grade M-20
(Proportions as per table 9 of IS456 2000 in masses
by weigh batching) using granite, quartz trap metal of
size 6 mm to 20 mm for RCC work, including
scaffolding centring, formwork, needle vibrated
consolidation, curring complete up to 6 meter depth of
height (excluding cost of reinforcement and heat
finishing) with centring and shuttering/de-shuttering etc
complete for structure other than water retaining
(below G.L) Footing (without form work)
Supply and fabrication of Street light three phase Iot
GSM/GPRS Central Control & Monitoring System
(CCMS) Control Panel with all switch gear, bus-bar,
nos LCD Display, Energy Saving Feature and Spare
Relay facility having 10 years of reserve battery for
RTC with 50 programmable schedule, month-wise
offset settable facility, astronomic sunrise/sunset time
programming inbuilt for yearlong schedule. Operating
voltage @440 V ac with over voltage & short circuit
protection. 2 hours battery backup for street light
controller. Panel to have 1 nos of 3 phase- class
Energy Meter for Energy & fault monitoring on CCMS
web dashboard. power and control wiring etc complete
as per specification given, panel Enclosure fabricated
in MS 14 Gauge sheet & Enclosure size is 1000 mm x
1000 mm x 500 mm with 500 mm height mounting
stand with double door type. All incoming and outgoing
cable termination should be suitable for ring type lugs
termination, Panel suitable for 4 Nos out going circuits
for 4 C x 16 Sq.mm cable and 1 Nos incoming cable of
size 4C x 50 Sq.mm with following switch gear
complete connection. Panel suitable for outside open
area installation and whether proof with canopy, Panel
should be design with Double door with two separate
compartments with two inner door for cable termination
and switch gear. Panel Having IP65 Rating. Local
communication facility via mobile application in case of
GPRS connectivity frailer.
63 Amp Four Pole MCCB 36KA with thermal magnetic
Release -- 01 No
R-Y-B Indication Lamp 230 V AC
1 Nos 4 Pole ELCB
Door Switch for unauthorized access & tamper
Detection & Accelerometer for panel movement
detection &tamper alert
3 Nos of 3 Pole Contactor (ML-2 32A AC3 X 3 Nos)
CCMS Controller with timer -
2 Pole 2way Selector switch - 01 No
6A Control SP MCB, 10KA -01 No
O/G 32 A SP MCB, 10 KA - 16 No
Power terminal CBT /KBT type - 20 No's
Power Wiring 16 SQ.mm,25 Sq.mm, and 50 Sq.mm
copper flexible cable
1 Nos 4g / 5G Sim with slot with necessary data pack
5 Year Cloud Server Subscription
Supplying & erecting funnel type earthing having earth
plate of 600 mm x 600 mm x 3.15 mm thk. Copper
earth plate burried in specifically prepared earth pit
mtr. below ground with 40 Kg. Charcoal and 40 Kg.
salt with alternate layers of charcoal & salt, 38 mm dia
Medium Class G. I. Pipe with funnel with a wire mesh
for watering & bricks massanary block, C. I. cover
complete as per para 7.3 of IS : 3043 with necessary
length of double 8 SWG copper earth wire - bolted to
the plate and covered in 38 mm dia. G. I. pipe -
mtr. long complete connected to the nearest switch
gears with end socket as per direction & duly tested by
earth tester confirming to ISS & as per drawing - (1
Job per Distribution Box)
Total Rs. Of Part B
Add Total of Part A
Total Rs.of Part-A+B
1 The rates offered by Bidder shall be Exclusive of GST.
The rates offered shall be inclusive of all applicable taxes (1% LWC, ESIC, PF,
2 packing, forwarding, insurance, loading, unloading, shifting & transportation at
store/ site of work at Ankleshwar Notified Area.)
I/We have read the conditions mentioned in this tender & agree to abide by the
Please note that the agency in whose favor the tender is finalized by the
4 competent authority shall have to submit the document like insurance of the staff
engaged RPFC No. Labour license etc. and documents for vehicle.
The successful bidder in whose favor the tender is finalize by the competent
authority has to enter in to an agreement with Notified Area office in B-1
agreement form, the conditions & clauses of the agreement shall be binding to the
agency. If the bidder desires to study the same, the same is available in the office
of the Notified Area Officer, GIDC, and Ankleshwar during office hours of the
1% labour welfare cess on the bill amount will be deducted from the each RA bill
as per Govt. norms.
I / we agree to carry out the above work at ______% above the estimated rate put to tender
I / we agree to carry out the above work at _______% below the estimated rate put to tender.
Estimated amount Estimated amount
put to tender Rs.
9520507.43 put to tender Rs.
Deduct : % below Rs.___________________ Add :% Above Rs.___________
Net amount Rs.___________________ Net amount Rs.__________
Signature of Contractor with Seal Chief Officer
NAA GIDC Ankleswhar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
DTP for ARC for O M R of St.light for Zone-2.pdf
BOQ for Zone-2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .