| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC BINDODPUR KALIBARI KATIHAR 854105 BIHAR | KATIHAR | KATIHAR | BIHAR | 854105 | ₹8.8 L | L1 | Accepted-AOC Being the lowest Bidder |
| 2 | L2₹9.7 LRejected-Finance AMLA TOLA DISTT KATIHAR BIHAR 854105 | KATIHAR | BIHAR | 854105 | ₹9.7 L | L2 | Rejected-Finance Not being the Lowest Bidder |
| 3 | Rejected-Technical 0 BANI MOHAN ROAD SAROJNI NAGAR VILL AND POST TIRWA BANTHRA LUCKNOW UTTAR PRADESH 226401 UDYAM UP 50 0138308 | LUCKNOW | UTTAR PRADESH | 226401 | - | - | Rejected-Technical Adverse remark in WLR |
| Sl No | Description | Qty | Unit | M/S. R.D. Construction L1 | Prahalad Rai L2 |
|---|---|---|---|---|---|
| 1.00 | S&F in replacement of steel tubular swaged poles complete as per IS-2713 MS base plate of size 300mmx300mmx6mm, final taper plug, bolts, nuts and screws as specified type 410 SP-31(9 mtr long) including painting two coats of aluminium paint over one coat of red oxide primer including 4 Nos band/straps with yellow and black colour in alternate way (250 mm wide each) aluminium paint two coat at a distance 300 mm from plinth block and marking pole nos with black paint including tarring one coat on steel surface embedded in concrete complete all as specified and directed.
Note:-
Necessary earth work and excavation, PCC, disposal of surplus soil to a distance not exceeding 50 m shall measured and paid sepearately complete all as specfied and directed. | 3 | Each | 19,000 ₹57,000 | 30,000 ₹90,000 |
| 2.00 | S&F in repair of MCCB 4 pole, 415 volt, adjustable thermal and magnetic release type 63 Amp breaking capacity 16 KA complete, including terminal links of suitable amp rating and size all as specified and directed. | 3 | Each | 5,600 ₹16,800 | 1,000 ₹3,000 |
| 3.00 | S&F in repairs/replacement MCB, SP, AC, 240 volts of 06 to 32 Amps capacity 10 KA, 'C' Series and making connections with suitable size of copper lugs complete all as specified & directed | 15 | Each | 230 ₹3,450 | 500 ₹7,500 |
| 4.00 | S&F in repairs/replacement MCB, SPN, AC, 240 volts of 40 Amps capacity 10 KA, 'C' Series and making connections with suitable size of copper lugs complete all as specified & directed | 3 | Each | 1,000 ₹3,000 | 1,100 ₹3,300 |
| 5.00 | Supply and fixing in repair LED flood light 50W, 6500K, IP66 protection complete all as specified and as directed.Make Havells cat no LHEECNP7PB6J050 or eqv
Notes:-
(i) Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of warranty certificate.
(ii) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and Failure due to electrical impact.
(iii) All T& P required at site for installation of light on Pole / Bldg /Tower or at any location shall be arranged by contractor.
(iv) Taking down of defective light and fittings is deemed to be included in the quoted rate | 8 | Each | 1,750 ₹14,000 | 4,500 ₹36,000 |
| 6.00 | Supply and fixing in repair LED Gate light in aluminum die cast with modern artistic design and white PC diffuser suitable with LED lamp B22 ,7.5 W,230 V AC complete with IP 65/66 protection complete all as specified and as directed.Make Havells cat no LHFOASE1TN5W009 or eqv.
Notes:-
(i) Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of warranty certificate.
(ii) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and Failure due to electrical impact.
(iii) All T& P required at site for installation of light on Pole / Bldg /Tower or at any location shall be arranged by contractor.
(iv) Taking down of defective light and fittings is deemed to be included in the quoted rate | 10 | Each | 1,900 ₹19,000 | 7,000 ₹70,000 |
| 7.00 | Supply and fixing LED garden light/spike light with modern artistic design and water proof coating ,10/12 W,230 V AC complete with IP 65/66 protection complete all as specified and as directed.Make Havells model no. LHEVACPBPN6K010 10W LED 3000K or eqv.
Notes:-
(i) Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of warranty certificate.
(ii) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and Failure due to electrical impact.
(iii) All T& P required at site for installation of light on Pole / Bldg /Tower or at any location shall be arranged by contractor.
(iv) Taking down of defective light and fittings is deemed to be included in the quoted rate | 10 | Each | 2,400 ₹24,000 | 7,000 ₹70,000 |
| 8.00 | Supply and fixing in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
Notes:-
(i) If connection cable from pole Juction box to street light and street light bracket is required to be replace it shall be measured and paid seperately under respective items.
(ii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles.
(iii) Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of warranty certificate.
(iv) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and Failure due to electrical impact.
(v) The contractor shall submit the surge protection certificate.
(vi) All T& P required at site for installation of light on Pole / Bldg /Tower or at any location shall be arranged by contractor.
(iv) Taking down of defective light and fittings is deemed to be included in the quoted rate. | 25 | Each | 2,850 ₹71,250 | 4,000 ₹1 L |
| 9.00 | M&L for G.I (medium grade, ISI ) pipe 40mm dia, 1.5 Mtr long medium grade, bend to shape for street light fittings bracket, with 2 pairs of MS clamps of suitable length of size 40 mm x 5 mm of MS flat iron with nuts, bolts & washer including applying two coats Synthetic enamel aluminium paint over a coat of red-oxide taking out old unserviceable ones, complete all as specified and as directed. | 35 | Each | 500 ₹17,500 | 1,000 ₹35,000 |
| 10.00 | S&F in repair astro time switch with contractor on existing panel including taking down complete all as specified and directed.
Make: L&T Cat no AUTS02AST00 or equivalent in legrand/C&S. | 3 | Each | 5,400 ₹16,200 | 8,000 ₹24,000 |
Updated dates
Tender Value
₹10.0 L
EMD Value
₹19,980
Closing Date
20 Mar 2026, 6:00 pmClosed
AGE (I) KATIHAR
SIRSA ARMY CAMP PIN-854106
REPAIR/MAINT OF SECURITY LIGHTS/STREET LIGHTS AND ALLIED WORKS AT MAUZA DALAN AREA MIL STN KATIHAR
2026_MES_753395_1
8061/E8
Open Tender
Electrical and Maintenance Works
180 days
AGE (I) KATIHAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE (I) KATIHAR
₹19,980
Yes
8 May 2026
20 Feb 2026
27 Mar 2026
20 Feb 2026
20 Mar 2026
6 Mar 2026
S&F in replacement of steel tubular swaged poles complete as per IS-2713 MS base plate of size 300mmx300mmx6mm, final taper plug, bolts, nuts and screws as specified type 410 SP-31(9 mtr long) including painting two coats of aluminium paint over one coat of red oxide primer including 4 Nos band/straps with yellow and black colour in alternate way (250 mm wide each) aluminium paint two coat at a distance 300 mm from plinth block and marking pole nos with black paint including tarring one coat on steel surface embedded in concrete complete all as specified and directed. Note:- Necessary earth work and excavation, PCC, disposal of surplus soil to a distance not exceeding 50 m shall measured and paid sepearately complete all as specfied and directed.
S&F in repair of MCCB 4 pole, 415 volt, adjustable thermal and magnetic release type 63 Amp breaking capacity 16 KA complete, including terminal links of suitable amp rating and size all as specified and directed.
S&F in repairs/replacement MCB, SP, AC, 240 volts of 06 to 32 Amps capacity 10 KA, 'C' Series and making connections with suitable size of copper lugs complete all as specified & directed
S&F in repairs/replacement MCB, SPN, AC, 240 volts of 40 Amps capacity 10 KA, 'C' Series and making connections with suitable size of copper lugs complete all as specified & directed
M&L for G.I (medium grade, ISI ) pipe 40mm dia, 1.5 Mtr long medium grade, bend to shape for street light fittings bracket, with 2 pairs of MS clamps of suitable length of size 40 mm x 5 mm of MS flat iron with nuts, bolts & washer including applying two coats Synthetic enamel aluminium paint over a coat of red-oxide taking out old unserviceable ones, complete all as specified and as directed.
S&F in repair astro time switch with contractor on existing panel including taking down complete all as specified and directed. Make: L&T Cat no AUTS02AST00 or equivalent in legrand/C&S.
S&F cable PVC insulated flexible type 1.5 sqmm x 3 core copper conductor cable including taking out old and unserviceable cable from juction box to street light fiting, complete all as specifid and as directed. Make: Havells ,KEI/POLYCAB or Eqv.
M&L for for PCC (1:3:6) Type C2 (using 40 mm graded stone aggregate) for foundation of electirc pole and panel board etc complete all as specified and directed.
M&L for PCC (1:2:4) type B1 ( using 20 mm graded stone aggregate) for coping of poles upto 30cm above ground and finishing the surface even and smooth without extra cement complete all as specified and directed.
M&L for laying 15 mm bore GI pipe, light grade with all fittings, from junction box to street light fitting to carry connection wire or for protection of pipe, including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge.
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core including connecting the cables at both ends by providing suitable size aluminium lugs & glands at the termination ends, complete all as specified and as directed.
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armored, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 4 core including connecting the cables at both ends by providing suitable size aluminium lugs & glands at the termination ends, complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth in foundation of pole/ laying of under ground cable and including getting out of any type of soft/loose soil, complete all as specified and as directed.
Materials and labour for sand filling around the cable with approved quality coarse river sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed by the Engr-in-Charge.
Material and labour for burnt bricks sub class 'B laid flat in trenches over sand cushioning for cable protection complete all as specified and as directed.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil, complete all as specified and as directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
M&L painting of steel pole (swan neck type or straight type) up to 9 mtr height with cross arms, clamp of any length and shape for street light with two coats of aluminium paint after scraching out old paint, cleaning and exiting surface rust free, preparation of the existing surface, including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ Stricker, including one coat of lime wash on PCC copping of pole complete all as specified and as directed.
M&L for cutting the Bitumin road/ PCC road/hard standing n.exc 0.45m width and n.exc 0.90 m in depth and making good disturbed surfaces by using PCC type C2 (1:3:6) by using 20 graded stone aggregate matching with the existing specification and finish including disposal of surplus material to a distance n.exc 50m complete all as specified and as directed by Engr-in-Charge.
M&L for laying 40 mm bore GI pipe, light grade with all fittings, in crossing road/path and in pole up to junction box including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge. Note:- Cutting/Boring under road/path will be measured and paid under respective item.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron wire of dia 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel, earthing lead to be protected by galvanised iron pipe of 15 mm dia (Medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch or as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) and earthing pit with suitable handle including taking down and necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) including testing on completion complete all as specified and as directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire.
Dismantling the existing corroded outdoor panel board including all unserviceable accessories and Fabrication, Supply and installation as in replacement outdoor type LT panel board of suitable size (Minimum 900 x 900x 300 mm) with 3.15 mm thick MS sheet with top inclined canopy, floor mounted type, with base frame and four Nos. legs of 450 mm length made up of 40x40x 5mm angle iron, both side opening, having Copper busbar of suitable size of rated 200 Amps (3 Nos Phase + 1 No. Neutral half in capacity of phase) with separate chambers to accommodate and including following accessories. Make: L&T or eqv. INCOMING DETAILS:- (a) MCCB adjustable thermal magnetic release 80A, 16 KA, 4pole - 01 Nos. (b) Digital MFM L&T, Cat No. WL411010OOOO -01 Nos (d) R-Y-B indicator light. set of 3 -01 Nos (e) Digital Street Light Timer Control with Contactor - 01 No. OUTGOING DETAILS:- (a) MCB SPN 06-32 Amps,10 KA, C- series - 8 Nos (6W + 2S)
Supply and fix in repair electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH
Supply and fix in repair electronic meters temper proof LCD display with polycarbonate cover 415 V,3 phase, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
tender8061.pdf
Tender Documents • 1.50 MB
BOQ_843849.xls
BOQ • 1.09 MB
Download all tender documents and submit your bid