| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC CAMP AT GORUBANDHA MISSAMARI ASSAM 784506 | SONITPUR | ASSAM | 784506 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹44.7 L+₹1.2 L (2.77%)Rejected-Finance P O P S MISSAMARI DIST SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹45.4 L+₹1.9 L (4.48%)Rejected-Finance GARUBANDHA MISSAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹45.5 L+₹2.1 L (4.72%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹46.7 L+₹3.2 L (7.44%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
3 Oct 2024, 6:00 pmClosed
GE MISSAMARI
PO-Missamari Dist-Sonitpur Assam
REPAIR TO STANDBY DISTRIBUTION SYSTEM AND MISC WORKS AT SOUTH OF RLY LINE UNDER GE MISSAMARI
2024_MES_673570_1
8514/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE MISSAMARI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE MISSAMARI
₹90,000
Yes
23 Nov 2024
10 Sept 2024
5 Oct 2024
10 Sept 2024
3 Oct 2024
25 Sept 2024
11 Sept 2024 - 17 Sept 2024
Amount
M&L Servicing to DG set of capacity 500 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at Sewage Treatment Plant (i) Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v) Air filter - 01 set (vi) Cleaning of fuel tank - 01 Job (vii) Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job
M & L for Servicing to DG set of capacity 250 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at 671 EME (i) Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v) Air filter - 01 set (vi) Cleaning of fuel tank - 01 Job (vii) Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job
M & L for Servicing to DG set of capacity 125 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at Old PH 33KV MRS-I (i) Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v) Air filter - 01 set (vi) Cleaning of fuel tank - 01 Job (vii) Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job
M & L for Servicing to DG set of capacity 100 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at Trolley mounted DG (Div), Signal Centre DG Set (i) Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v) Air filter - 01 set (vi) Cleaning of fuel tank - 01 Job (vii) Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job
M & L for Servicing to DG set of capacity 62.5 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at OMC, 311 ASC Perimeter lights (TCP-I), MRS-II, Signal Centre, 223 Transit camp, STP SPS-F Old SBI (i) Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v) Air filter - 01 set (vi) Cleaning of fuel tank - 01 Job (vii) Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job
M & L for Servicing to DG set of capacity 40 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at 4 Core Zonal Wksp (i) Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v) Air filter - 01 set (vi) Cleaning of fuel tank - 01 Job (vii) Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job
M & L for Servicing to DG set of capacity 30 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at 71 DOU, Signal Regt (i) Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v) Air filter - 01 set (vi) Cleaning of fuel tank - 01 Job (vii) Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job
M & L for Servicing to DG set of capacity 25 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at STP SPS-H Goving Nagar (i) Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v) Air filter - 01 set (vi) Cleaning of fuel tank - 01 Job (vii) Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job
M & L for Servicing to DG set of capacity 20 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at Zonal Wksp (i) Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v) Air filter - 01 set (vi) Cleaning of fuel tank - 01 Job (vii) Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job
M & L for Servicing to DG set of capacity 15 KVA with and including replacement of the worn out spares and drain out engine oil from the sump, cleaning with kerosene oil and filling up with new engine oil as manufacturer recommended grade & quality and testing for smooth running at rated speed complete all as manufacturer’s specifications and as directed The following items to be replaced after a period of 250 to 300 hours run of DG set ( parts must be replaced as per sample obtained in credit) installed at 176 MCO, STP SPS-B Transit Camp, STP SPS-D ENG KLP, STP SPS-I NEAR MRS (i) Fuel filter (Primary & Secondary) - 01 Set (ii) Spin –on filter for lubricant - 01 No (iii) Engine oil as per manufacture specifications (iv) coolent as per manufacture specifications (v) Air filter - 01 set (vi) Cleaning of fuel tank - 01 Job (vii) Tapping adjustment and calibration- 01 job (viii) Tighting of all nuts, bolts, screws,and any loose parts of DG Set - 01 Job
M&L Battery leads complete with terminal and lugs (set of three Nos) including removal of existing unserviceable one complete all as directed.
M&L Battery leads complete with terminal and lugs (set of two Nos) including removal of existing unserviceable one complete all as directed.
M&L Fan Belt complete suitable for DG set of capacity 100 to 500 KVA including removal of existing unserviceable one compete all as specified and directed.
M&L Fan Belt complete suitable for DG set of capacity 82.5 to 7.5 KVA including removal of existing unserviceable one compete all as specified and directed.
M&L Radiator Fan Blade complete suitable for capacity 7.5 to 82.5 KVA including removal of existing unserviceable one compete all as specified and directed.
M&L Radiator Fan Blade complete suitable for capacity 100 to 500 KVA including removal of existing unserviceable one compete all as specified and directed.
M&L disconnecting all electrical connections from DG set alternator of any capacity from base plate by opening nuts & bolts keeping aside the alternator for inspection and testing & commissioning complete all as specified & directed.
M&L Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing of 7.50 KVA to 15.00 KVA DG complete all as specified and directed.
M&L Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing of 20 KVA to 40 KVA DG complete all as specified and directed.
M&L Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing of 62.5 KVA to 82.5 KVA DG complete all as specified and directed.
M&L Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing of 100 KVA to 125 KVA DG complete all as specified and directed.
M&L Self Starter assembly 24 Volts complete suitable for 100 KVA to 500 KVA DG set including removal of existing unserviceable one compete all as specified and directed.
M&L Self Starter assembly 12 Volts complete suitable for 7.5 KVA to 82.5 KVA DG set including removal of existing unserviceable one compete all as specified and directed.
M&L DC Alternator assembly 24 Volts complete suitable for 100 KVA to 500 KVA DG set including removal of existing unserviceable one compete all as specified and directed.
M&L DC Alternator assembly 12 Volts complete suitable for 7.5 KVA to 82.5 KVA DG set including removal of existing unserviceable one compete all as specified and directed.
M&L SMPS (System main power supply) control unit assembly 24Volts complete suitable 100 KVA to 500 KVA DG set including removal of existing unserviceable one compete all as specified and directed.
M&L SMPS (System main power supply) control unit assembly 12Volts complete suitable 100 KVA to 500 KVA DG set including removal of existing unserviceable one compete all as specified and directed.
M&L AVR (Automatic Voltage regulator) control unit assembly suitable 7.5 KVA to 82.5 KVA DG set including removal of existing unserviceable one compete all as specified and directed.
M&L AVR (Automatic Voltage regulator) control unit assembly suitable 100 KVA to 500 KVA DG set including removal of existing unserviceable one compete all as specified and directed.
M&L Brass battery terminals extended type heavy grade including removal of existing unserviceable one compete all as specified and directed.
M&L SS canopy Stainless steel hinges as per original OEM for acoustic doors with suitable Stainless steel bolts and nuts of DG set including removal of existing unserviceable one compete all as specified and directed.
M&L Radiator hose pipe with suitable clamps of DG set including removal of existing unserviceable one compete all as specified and directed.
M&L solenoid switch assembly 24 volts suitable for 100 KVA to 400 KVA DG set including removal of existing unserviceable one compete all as specified and directed.
M&L solenoid switch assembly 12 volts suitable for 7.5 KVA to 82.5 KVA DG set including removal of existing unserviceable one compete all as specified and directed.
M&L Anti vibration pads with suitable bolts and washers including removal of existing unserviceable one compete all as specified and directed.
M&L Asbestos Rope including removal of existing unserviceable one compete all as specified and directed.
M&L Water pump Assembly suitable for 7.5 KVA to 63 KVA DG set including removal of extg unsv one compete all as specified.
M&L Water pump Assembly suitable for 82.5 KVA to 125 KVA DG set including removal of extg unsv one compete all as specified.
M&L Water pump Assembly suitable for 200 KVA to 500 KVA DG set including removal of extg unsv one compete all as specified.
M&L Feed pump suitable for 7.5 KVA to 63 KVA DG set including removal of extg unsv one compete all as specified.
M&L Feed pump suitable for 82.5 KVA to 125 KVA DG set including removal of extg unsv one compete all as specified.
M&L Electronic Type Starting Switch for 7.5 KVA to 15 KVA DG set including removal of extg unsv one compete all as specified.
M&L Electronic Type Starting Switch for 30 KVA to 125 KVA DG set including removal of extg unsv one compete all as specified.
M&L taking out unserviceable radiator from existing DG set of capacity 200 KVA to 400 KVA for servicing and cleaning by using chemical solution for removal of scaling/foreign material from water fins (tubes) through authorized dealer including checking and repair/replacement of water circulating pumps, thermostat, radiator cooling fan, all types of belts including soldring of damaged radiator fins and hose pipes for smooth functioning, complete all as specified and as directed.
M&L taking out unserviceable radiator from existing DG set of capacity 62.5 KVA to 125 KVA for servicing and cleaning by using chemical solution for removal of scaling/foreign material from water fins (tubes) through authorized dealer including checking and repair/replacement of water circulating pumps, thermostat, radiator cooling fan, all types of belts including soldring of damaged radiator fins and hose pipes for smooth functioning, complete all as specified and as directed.
M&L taking out unserviceable radiator from existing DG set of capacity 7.5 KVA to 45 KVA for servicing and cleaning by using chemical solution for removal of scaling/foreign material from water fins (tubes) through authorized dealer including checking and repair/replacement of water circulating pumps, thermostat, radiator cooling fan, all types of belts including soldring of damaged radiator fins and hose pipes for smooth functioning, complete all as specified and as directed.
S&F battery low maintenance heavy duty lead acid of capacity 12 volts 150 AH suitable for DG sets including removal of existing unserviceable one compete all as specified and directed.
S&F battery low maintenance heavy duty lead acid of capacity 12 volts 180 AH suitable for DG sets including removal of existing unserviceable one compete all as specified and directed.
S&F battery low maintenance heavy duty lead acid of capacity 12 volts 200 AH suitable for DG sets including removal of existing unserviceable one compete all as specified and directed.
M&L Low oil pressure switch (LLOP) as per Existing OEM Suitable for upto 200 KVA DG sets capacity compete all as specified and directed.
M&L microprossesor based fully configurated as per Existing OEM controller display panel board Suitable for upto 125 KVA DG sets capacity compete all as specified
M&L Onload change over switch of capacity 63 Amps (Side handle) in sheet metal encloser, 415 V, 50Hz, 4 Pole compete all as specified and directed.
M&L Onload change over switch of capacity 100 Amps (Side handle) in sheet metal encloser, 415 V, 50Hz, 4 Pole compete all as specified and directed.
M&L Onload change over switch of capacity 400 Amps (Side handle) in sheet metal encloser, 415 V, 50Hz, 4 Pole compete all as specified and directed.
M&L Onload change over switch of capacity 630 Amps (Side handle) in sheet metal encloser, 415 V, 50Hz, 4 Pole compete all as specified and directed.
Scraping old paint of any capacity DG set Chessis (Approx coverage area 5-7 Sqm) installed at various locations and Painting with one coats of red oxide paint and two coat of synthetic enamel paint of shade compete all as directed.
M & L earthing complete with copper Earth Plate Electrode 600mm x 600mm x 3.15mm, thick buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connected to GI earth strip 32X6 mm drawn through and including Galvanised Iron protection Pipe 40 mm bore (dia) Light grade by means of Bolts, Nuts, Check Nuts and Washers etc Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150mm thick PCC Pit in cement concrete 1:3:6 (20 mm graded aggregrate ), Precast RCC 1:2:4 (20mm graded aggregrate ) cover slab 350 x350 x 50mm thick reinforced with and including 8mm dia TMT Bars @ 10 cm Centre to Centre both ways GI Wire Mesh , Funnel, with GI Watering Pipe 20mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 meter and all as shown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion complete all as specified and as directed.
M&L taking out all injector (by using right tools means torque wrench ) from DG set 62.5 KVA to 125 KVA for servicing through authorised dealar and refixing its original position after repairing including replacement of plunger, washer, jets and any internal parts of injector, complete all as specified and as directed.
M&L taking out all injector (by using right tools means torque wrench ) from DG set 7.5 KVA to 45 KVA for servicing through authorised dealar and refixing its original position after repairing including replacement of plunger, washer, jets and any internal parts of injector, complete all as specified and as directed.
M&L fuel pipe ( benjo pipe) having length 1 feet to 3 feet of suitable size as per OEM including removal of existing unserviceable one compete all as directed.
M&L Hause pipe of suitable size and length as per OEM for 62.5 KVA to 400 KVA including removal of existing unserviceable one compete all as directed.
M&L contractor with add on accessories for AMF panel of suitable rating and exciting coil voltage 240/ 415 V as per OEM for 7.5 KVA to 45 KVA including removal of existing unserviceable one compete all as directed.
M&L contractor with add on accessories for AMF panel of suitable rating and exciting coil voltage 240/ 415 V as per OEM for 62.5 KVA to 320 KVA including removal of existing unserviceable one compete all as directed.
M&L contractor with add on accessories for AMF panel of suitable rating and exciting coil voltage 240/ 415 V as per OEM for 200 KVA to 500 KVA including removal of existing unserviceable one compete all as directed.
Supply only Coolent suitable as per OEM suitable for DG sets compete all as directed.
Supply only Engine OIL suitable as per OEM suitable for DG sets compete all as directed.
Supply only distilled water suitable for DG sets compete all as directed.
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laying in trenches or fixing with Walls/Poles, segreating serviceable Pipes, Cables etc and keep in safe custody for reuse, complete all as specified and as directed. Note : Earthwork will be measured and paid under appropriate Items.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.
M & L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for.
Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified and directed.
Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 80mm bore (dia) for passing of pipes, complete all as specified and as directed. Note:- GI pipe will be measured and paid seperately under appropiate item
S&F in repair GI Tubing light grade of size 80mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed.
S&F in repair GI Tubing light grade of size 50mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed.
S&F in repair GI Tubing light grade of size 40mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clamp as per site requirement etc complete all as specified and directed.
M/S RANA ENGINEERING ENTERPRISE (BID ID -3119898)
M/s AKRITI ENTERPRISE (BID ID -3125936)
bkgeneralstores (BID ID -3118451)
Maa Mira Enterprise (BID ID -3124587)
United Traders (BID ID -3122776)
M/S Singha Enterprise (BID ID -3120465)
M/S Mahabir Traders (BID ID -3113070)
Satya Enterprises (BID ID -3123604)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .