Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAdmitted-Finance | ₹37.1 L | L1 | Admitted-Finance |
| 2 | L2₹37.3 LAdmitted-Finance | ₹37.3 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Dev Bhoomi Enterprises L1 | SMA ENERGY & INFRA PRIVATE LIMITED L2 |
|---|---|---|---|---|---|
| 1.01 | Solar Monocrystalline PV module minimum 550/570 Wp for 10KW to ensure the output. | 4 | Job | 2,97,500 ₹11,90,000 Lowest | 2,98,540 ₹11,94,160 |
| 1.02 | String invertor with power exporting facility to the grid having out put shall be 415 V AC, 50 H3, 3 Phase degree of protection IP-65 with self protective and self diagnositic features such as over voltage over current (both input and output) over/ under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage competable mean in each and every sense to synchronize with UPCL grid. | 4 | No | 89,880 ₹3,59,520 Lowest | 91,500 ₹3,66,000 |
| 1.03 | Hot dipped Galvanised structure including SS nut bolts at campus of pump housecomplete with grouting by cement concrete etc. | 4 | Job | 93,500 ₹3,74,000 | 93,450 ₹3,73,800 Lowest |
| 1.04 | DCDB box between solar panels and the invertor containing DC SPD and DC MCB with fuse set complete | 4 | Job | 5,485 ₹21,940 Lowest | 5,850 ₹23,400 |
| 1.05 | ACDB box with protective devices for overload and short circuit in between invertpr and AC side | 4 | No | 6,470 ₹25,880 Lowest | 6,520 ₹26,080 |
| 1.06 | Copper bonded Lightening arrestor & surge protection. | 8 | Job | 7,760 ₹62,080 Lowest | 7,870 ₹62,960 |
| 1.07 | Fire extenguisher 5 Kg. | 4 | No. | 14,700 ₹58,800 | 14,560 ₹58,240 Lowest |
| 1.08 | 03 Nos.Chemical earthing complete with 1 core 4 sqmm earth wire PVC pits etc as per IE rule | 4 | Job | 29,750 ₹1,19,000 Lowest | 29,870 ₹1,19,480 |
| 1.09 | Cabling work by copper 4 core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor | 4 | Job | 27,485 ₹1,09,940 | 27,480 ₹1,09,920 Lowest |
| 1.10 | Miscellenious work i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable , Fire safety system etc. | 4 | Job | 29,920 ₹1,19,680 | 25,900 ₹1,03,600 Lowest |
Tender Value
Refer Docs
EMD Value
₹88,500
Closing Date
15 Jun 2026, 5:00 pmClosed
Superintending Engineer,
Superintending Engineer, Mechanical Circle, UPJN, Haldwani
SURVEY AND SITC OF GRID CONNECTED ROOFTOP ON GROUND OR SUITEBLE LOCATION IN SOLAR PV POWER PLANT INCLUDING ALL ASSOCIATED ELECTRICAL CIVIL AND MECHANICAL WORKS IN DIFFERENT SCHEMES CONSTRUCTED UNDER JJM OTHER PROGRAME AT BLOCK BHIMTAL DIST NTL
2026_MDPEY_95958_1
204/G-7/10 DATED 22.05.2026
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
90 days
Haldwani
Please refer tender documents
3 documents required · 3 mandatory
₹3,540
Executive Engineer UKPJN
₹88,500
haldwani
18 Aug 2026
26 May 2026
17 Jun 2026
26 May 2026
15 Jun 2026
4 Jun 2026
2 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Solar Monocrystalline PV module minimum 550/570 Wp for 10KW to ensure the output. | 4 | Job | - | - |
| 1.02 | String invertor with power exporting facility to the grid having out put shall be 415 V AC, 50 H3, 3 Phase degree of protection IP-65 with self protective and self diagnositic features such as over voltage over current (both input and output) over/ under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage competable mean in each and every sense to synchronize with UPCL grid. | 4 | No | - | - |
| 1.03 | Hot dipped Galvanised structure including SS nut bolts at campus of pump housecomplete with grouting by cement concrete etc. | 4 | Job | - | - |
| 1.04 | DCDB box between solar panels and the invertor containing DC SPD and DC MCB with fuse set complete | 4 | Job | - | - |
| 1.05 | ACDB box with protective devices for overload and short circuit in between invertpr and AC side | 4 | No | - | - |
| 1.06 | Copper bonded Lightening arrestor & surge protection. | 8 | Job | - | - |
| 1.07 | Fire extenguisher 5 Kg. | 4 | No. | - | - |
| 1.08 | 03 Nos.Chemical earthing complete with 1 core 4 sqmm earth wire PVC pits etc as per IE rule | 4 | Job | - | - |
| 1.09 | Cabling work by copper 4 core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor | 4 | Job | - | - |
| 1.1 | Miscellenious work i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable , Fire safety system etc. | 4 | Job | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.04 MB
BOQ_113430.xls
BOQ • 0.35 MB
Gridsolarbhimtal.pdf
Tender Documents • 2.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].