Loading…
Loading…
Tender Value
₹19.4 L
EMD Value
₹38,878
Closing Date
8 Jul 2026, 12:00 pm
Similar tender results from the same govt authority in the past 3 years.
Executive Engineer, PWD, Jal Electrical Division.
Office of the Executive Engineer, PWD, Jalpaiguri Electrical Division, Purta Bhavan, Hakimpara, Post and Dist. - Jalpaiguri, Pin - 735101.
Upgradation of Banarhat RH under Banarhat Block in the district of Jalpaiguri---- SITC of Air Conditioning System.
2026_WBPWD_5015821_1
WBPWD/EE/JED/NIT 05e/T of 2026-27.
Open Tender
A/C ORG
60 days
Banarhat Rural Hospital Jalpaiguri.
Please refer Tender documents.
3 documents required · 3 mandatory
₹38,878
24 Jun 2026
24 Jun 2026
10 Jul 2026
24 Jun 2026
8 Jul 2026
24 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. | ||||||
| 1.1 | The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. (Make - Mitsubishi Electric /Daikin /O-General/ Carrier/LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/ Sharp/Mitsubishi Heavy/Voltas) | - | - | - | - | BI01010001010000000000000515BI0100001113 |
| 1.2 | Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4 Star(min). | 8 | Each | 52,281 | ₹4,18,248 | BI01010001010000000000000515BI0100001114 |
| 2 | Supply & Delivery of Concealed type split AC machine (a set of full metal body indoor and outdoor unit), having Cooling Capacity range (6.6 KW - 7.0 KW), with fixed speed compatible rotary compressor, refrigerant gas R 32 / R 410A, Air flow range CFM (780 - 850), both condenser and cooling coils made of copper tube, with P2 type capacitor, connecting chord with plug top, confirming to IS 1391 (Part-I & Part-II) with all amendments. Noise level not more than 52 db., suitable for 1 Ph. 230V, 50 Hz. power supply with a minimum 5- year OEM warranty on both the compressor and PCB.
(Make - Mitsubishi Electric/ Daikin/ O-General/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/ Sharp/ Mitsubishi Heavy/Voltas) | 13 | Each | 60,039 | ₹7,80,507 | BI01010001010000000000000515BI0100001115 |
| 3Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | ||||||
| 3.1 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 130 | RM | 223 | ₹28,990 | BI01010001010000000000000515BI0100001117 |
| 3.2 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 130 | RM | 507 | ₹65,910 | BI01010001010000000000000515BI0100001118 |
| 4S&F of additional following items for length exceeding 3.5 mtr for complete installation and commissioning of aboove AC machines. [Make: Finolex/RR Kable / Polycab /Havells/ KEI/ Gloster] | ||||||
| 4.1 | 2.5 sqmm, 3/4 core copper cable (FRLS type) | 130 | Mtr. | 102 | ₹13,260 | BI01010001010000000000000515BI0100001120 |
| 5 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. | 130 | Mtr. | 62 | ₹8,060 | BI01010001010000000000000515BI0100001121 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.57 MB
Tendernotice_2.pdf
PDF • 1.04 MB
BOQ_5084835.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid