Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹23.6 L+₹6.1 L (35.1%)Rejected-AOC SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L2 | Rejected-AOC Other Than Lowest Bidder |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
21 Nov 2024, 6:00 pmClosed
GE Chandigarh
GE Chandigarh N Area Pin-160003
REPAIR /REPLACEMENT OF SUBMERSIBLE PUMP AND CONNECTING ACCESSORIES AT K AREA INCLUDING REPAIR/MAINTENANCE OF EXTERNAL WATER SUPPLY, SUBMERSIBLE PUMP SET AND CONNECTING ITEMS AT DAD COLONY SECTOR 35B AND PCDA COMPLEX SEC-09 UNDER GE CHANDIGARH
2024_MES_680253_1
GE/CHD-65/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Chandigarh
Class D category a(ii) and b(i) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹64,000
Yes
17 Jan 2025
19 Oct 2024
23 Nov 2024
19 Oct 2024
21 Nov 2024
9 Nov 2024
19 Oct 2024 - 26 Oct 2024
Amount
Disconnection & taking out submersible pump with motor of any capacity 20 to 35 HP along with column pipe of any size upto 90 mtr (maximum) long and lowering the same after repairing to motor / pump along with existing / replaced column pipe, and re-connection of three phase AC Supply and tested at site to the satisfaction of Engineer-in Charge. Note for item no 3 to 7 : (i) Repair / replacement of pump /motor / column pipe / rubber gasket / Nut bolt and washers shall be measured and paid separately under respective items of this Schedule ‘A’. (ii) Transportation of defective motor / pump from well to work shop and vice-versa shall be deemed to be included in the unit rate of this item. Nothing extra shall be admissible on this account. (iii) The cost of T&P required for taking-out, lowering of submersible motor / pump / column pipe, dewatering the UG sump shall be deemed to be included in the unit rate of this item. Nothing extra shall be admissible on this account.
All as per above item No 01 here-in-before but 7.5 to 15 HP submersible pump set for under ground sump along with column pipe of any size upto 15mtr.
Dismantling of existing unserviceable submersible pump motor of 35 HP, 3 phase, 440 volts, 50 Hz, 2900 RPM and rewinding of stator with PVC insulated copper winding wire including sleeves, thimbles & minor spare parts like bronze bushes, gland packing etc and re-assembling the same motor after repair work . complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 03 he here-in-before but for submersible motor of 25 HP
All as per above item No 03 he here-in-before but for submersible motor of 20 HP
All as per above item No 03 he here-in-before but for submersible motor of 15 HP
All as per above item No 03 here-in-before but for submersible motor of 7.5 HP.
Supply & fixed bearing along-with thrust bearing plate for submersible Pump 35 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 08 here-in-before but for 25HP.
All as per above item No 08 here-in-before but for 20HP.
All as per above item No 08 here-in-before but for 15HP.
All as per above item No 08 here-in-before but for 7.5HP.
Supply & fixed motor bearing bush (set of five) for submersible Pump 35 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 13 here-in-before but for 25HP.
All as per above item No 13 here-in-before but for 20HP.
All as per above item No 13 here-in-before but for 15HP.
All as per above item No 13 here-in-before but for 7.5HP.
Supply & fixed water seal & adopter (Set of two) suitable for submersible Pump 35 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 18 here-in-before but for 25HP.
All as per above item No 18 here-in-before but for 20HP.
All as per above item No 18 here-in-before but for 15HP.
All as per above item No 18 here-in-before but for 7.5HP.
Supply & fixed stainless steel shaft suitable for submersible Pump 35 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 23 here-in-before but for 25HP.
All as per above item No 23 here-in-before but for 20HP.
All as per above item No 23 here-in-before but for 15HP.
All as per above item No 23 here-in-before but for 7.5HP.
Supply & fixed Neck ring of impeller of gun metal for submersible Pump 35 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 28 here-in-before but for 25HP.
All as per above item No 28 here-in-before but for 20HP.
All as per above item No 28 here-in-before but for 15HP.
All as per above item No 28 here-in-before but for 7.5HP.
Supply & fixed Bowl casing for submersible Pump 35 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 33 here-in-before but for 25HP.
All as per above item No 33 here-in-before but for 20HP.
All as per above item No 33 here-in-before but for 15HP.
All as per above item No 33 here-in-before but for 7.5HP.
Supply & fixed Shaft sleeve of stainless steel for submersible Pump 35 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 38 here-in-before but for 25HP.
All as per above item No 38 here-in-before but for 20HP.
All as per above item No 38 here-in-before but for 15HP.
All as per above item No 38 here-in-before but for 7.5HP.
Supply & fixed Gun metal Impeller Model V-9 for submersible Pump 35 HP complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 43 here-in-before but for 25HP.
All as per above item No 43 here-in-before but for 20HP.
All as per above item No 43 here-in-before but for 15HP.
All as per above item No 43 here-in-before but for 7.5HP.
Material & labour for Replacement of unserviceable Rubber gasket for column pipe (80/100/125 bore) in lieu of provided with new Rubber gasket for column pipe (80/100/125bore) complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing for Nut, Bolt & Washers machine made suitable for jointing of column pipe fixed as in repair complete all as specified and as directed by Engineer-in-Charge
Dsconnection and removing the unserviceable Column pipe and S&F 80 mm bore mild steel water pipe heavy duty both end flanged as column pipe (each length of pipe 3 metre long) as in repair complete all as specified and as directed by Engineer-in-Charge.
All as per item No 50 here-in-above but of 100 mm dia.
Disconnection and removing the unserviceable Heavy duty Socket connected between the lowering pipes of Submersible pumpsets and supply and fix GI Socket, Heavy duty 80mm dia and length 80mm ISI Marked complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 52 here-in-before but for 100mm
PVC insulated multi-stranded copper conductor 16 Sq mm (nominal area) 3 core submersible cable (copper) and connected to submersible pump set including submersible cable joints & LT panel board complete all as specified and directed.
All as per above item No 54 here-in-before but for 25Sqmm
All as per above item No 54 here-in-before but for 35Sqmm
Supply & fixing FASDS suitable for 35 HP submersible electric driven pump set, 3 Phase, AC 415 volt ,50 HZ with MS enclouser with Std proction etc complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing FASDS suitable for 25 HP Submersible electric driven pump set, 3 Phase, AC 415 volt ,50 HZ with MS enclouser with Std proction etc complete all as specified and as directed by Engineer-in-Charge.
Disconnection and removing the unserviceable MCCB, 4 pole, 160 Amps and Supply & fixing MCCB, 4 pole, 160 Amps, 50 Hz, 415 volts, Range : 125 - 160A, rupturing capacity 25 KA including connecting the cables complete all as specified and as directed.
All as per item No. 59 above but Capacity 200Amp.
All as per item No. 59 above but Capacity 100Amp.
Disconnection and removing the unserviceable Automatic star/delta starter and Supply & fixing Automatic star/delta starter in SS enclosure with relay max range 28 to 45 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 42 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed.
Disconnection and removing the unserviceable Automatic star/delta starter and Supply & fixing Automatic star/delta starter in SS enclosure with relay max range 20 to 32 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 40 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed.
Disconnection and removing the unserviceable DOL starter and Supply & fixing DOL starter Type - MK1, 15A, 3 Phase, 50 Cycles, Relay Range upto 9-14 Amp, 415V/440V including connecting the cable complete all as specified and as directed.
Disconnection and removing the unserviceable Electronic Timer and Supply & fixing Electronic Timer Series, Micon 225, Star Delta, Supply Voltage : 24 - 240 VAC/DC, 50 HZ, Timing : 0.3S - 120S including connecting the cable complete all as specified and as directed.
Disconnection and removing the unserviceable Thermal Overload Relay and Supply & fixing Thermal Overload Relay with Start & Off/Reset with Relay Range : 20 - 40A, 415V, 50 Hz including connecting the cable complete all as specified and as directed.
Disconnection and removing the unserviceable Contactor from existing AMF panel and Supply & fixing Power Contactor 1-40A, 220Volt AC, 50 Hz including connecting the cable complete all as specified and as directed.
Disconnection and removing the unserviceable 3P Contactor and S&F 3P Contactor MNX 32A, Coil Voltage 415V, 50 Hz including connecting the cable complete all as specified and as directed.
Disconnection and removing the unserviceable 3P Contactor and Supply & fixing 3P Contactor MNX 18A, Coil Voltage 415V, 50 Hz including connecting the cable complete all as specified and as directed.
Disconnection and removing the unserviceable MCCB and Supply & fixing MCCB, 3 pole, 125 Amps, 50 Hz, 415 volts, Range : 100 - 125A, rupturing capacity 25 KA including connecting the cables complete all as specified and as directed.
All as per item No. 70 above but Capacity 63Amp.
Supply and installation in repair single phase preventer for three phase panel set eletric driven 415 volts three phase starter complete all as specified and as directed.
Cleaning and maint of water supply installations and water tank including cutting/cleaning of grass/ bushes in surrounding of installation of clear water installation complete all as directed by Enginer-in-Charge
M&L DI pipe 200 mm (certifugally cast) class 'K-9' (ISI Mark) in any length with spigot and socket ends complete including rubber ring joint (Tyton joint) as per IS- 1536-2001 jointed and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified . Note :- Cost of rubber ring (tyton) joint is deemed to be included in the quoted rates .
Disconnection and removing the unserviceable Sluice Valve and S&F Sluice Valve IS-14846, PN 1.6 stainless steel spindle with hand wheel head, screwed both ends for GI/CI/DI Pipe 200 mm dia complete all as specified and directed.
Disconnection and removing the unserviceable Sluice Valve and S&F Sluice Valve IS-14846, PN 1.6 stainless steel spindle with hand wheel head, screwed both ends for GI/CI/DI Pipe 150 mm dia complete all as specified and directed.
Disconnection and removing the unserviceable CI Non Return valve and S&F Non return valve cast iron 100MM dia, PN-1.6 class with flanged ends at both sides complete fitted with GI pipe incl connected accessories and joining materials including taking down the old u/s one complete all as specified and as directed.
Disconnection and removing the unserviceable column pipe and S&F 150 mm colum pipe mild steel water pipe Heavy duty both end flangd as column pipe (each length of column pipe 3mtr) long as in repair complete all as directed by Engineer-in-charge.
Disconnection and removing the unserviceable thermal overload relay and Supply & fixing thermal overload relay with start & off/Reset with relay range 30 to 75 Amp omplete all as directed by Engineer-in-charge.
Supply and fixing in repair electronic over current relay (BCOR-FEZ), start (Off) reset and detachable screen (EOCR 3EZ MODE: 110AC), Relay complete all as pecified and as directed.
Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs upto 150mm bore complete all as specified and as directed
Construction of valve pit chamber of size 120 x120 x120 cm with brick masonary in cement mortar 1:4, all internal surface to be plastered in cement mortar 1:4 and floor 100mm thick in cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, including 6.00 mm thick MS sheet cover fixed with angle iron frame 40x40x6mm thick with locking arrangement and lifting handle including two coat of anti- corrosive synthetic enamel black paint over a coat of red oxide primer to steel surfaces including necessary earth work and PCC copping in cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as specified.
Supply and filling of calcium based granular (Calcium hypochlorit granular) disinfectant for Chlorination of water having more stable than chlorine gas and contains no mercury, no heavy metal contamination, supported with test certificate, all as specified and including daily testing of water from different -different locations in presence of MES / Medical authority from SHO/MI Room and maintaining record of test result in a register and otaining signature of Medical Authority for all as specified.
Dismantling the earth chamber, Excavation and removing the u/s earthing materials along with u/s earth electrodes from the existing u/s earth pits situated inside the K area of earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 2.25 mtr below normal ground level, connected to GI wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20mm dia GI watering pipe ‘medium grade’, GI protection pipe of size 20 mm dia upto 7.5 mtr length , funnel with wire mesh, earthing chamber with cement concrete (1:2:4) type B-1, RCC chamber cover 80mm thick (1: 1 ½ : 3) type B1, excavation & earth work all as shown in electrical plate No 5 of SSR (Part-I) and testing on completion, complete all as specified and directed.
Supply & fixing Tubes 20 mm bore, ‘medium grade’, ISI MARKED, galvanized iron pipes with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
All as per Item No 85 above but 25mm dia / bore.
All as per Item No 85 above but 50mm dia / bore.
M&L for run lead joint in position, including removing old lead to store of the following sizes 100mm dia for Spigot and socket pipe & fittings :-
All as per Item No 88 above but 150 mm dia / bore.
All as per Item No 88 above but 200 mm dia / bore.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5Core 50 Sqmm.
All as per Item No 92 above but size 3.5 Core 70 Sqmm.
Excavation in trenches in soft/loose soil not exceeding 1.50 meter wide and not exceeding 1.5 meter in depth and not exceeding 10sqmm on plan and getting out complete all as specified.
Returning,filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each excavated soil in trenches after the pipes have been laid and tested completed as in soft/loose soil, complete all as specified.
Removing of surplus soil/excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I
Supply and laying of class 'B' bricks for under ground cable protection as directed by Engineer- in - charge
Supply & fixing Tubes 15 mm bore, ‘medium grade’, ISI MARKED, galvanised iron pipes with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
Supply & fixing Tubes 80 mm bore, ‘medium grade’, ISI MARKED, galvanised iron pipes with all fittings and fixed complete laid in trnches or walls and ceilings or laid in floors, complete all as specified.
Taking up or down steel tubing 15 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down steel tubing 20 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down steel tubing 25 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down steel tubing 50 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Taking up or down steel tubing 80 mm bore and connections, including cleaning for re-fixing or removal to store complete all as specified.
Cutting existing 15 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.
Cutting existing 20 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.
Cutting existing 25 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.
Cutting existing 40mm to 50 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.
Cutting existing 80 mm bore, ‘medium grade’, galvanized tubes, for alteration or additions (each cut measured) providing threads etc.complete all as directed by the Engineer- in-Charge.
Material and labour for DI pipe 150 mm (certifugally cast) class 'K-9' (ISI Mark) in any length with spigot and socket ends as per is 1536-2001 jointed ie rubber gasket joint and laid in trenches or in any position, complete including taking down any type and size of pipe all as specified.
S&F Rubber gasket joint for 150 mm dia pipe complete all as specified
Supply & fixing Sluice valve PN-1.6 (ISI marked) confirming to IS-14846-2000 with brass spindle and fly net flanged both ends and drilled for jointing, wheel head type including nuts, bolts, washes & 02 Nos rubber insertion packing etc for 100 mm bore pipeand fixed, in repairs, complete all as specified.
Supply & fixing Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 25mm dia, IN REPAIRS, complete all as specified.
Supply & fixing Gun-metal, globe or gate valves, ISI marked (IS:778) with iron wheel head, screwed both ends for iron pipe and fixed of size 20mm dia, in repairs, complete all as specified.
Arresting of water leakage from existing pipe line in position from DI/CI/GI pipe of size 80mm to 100 bore ,including excavation through Men/Mechnical power ,cutting,welding as per site requirement,jointing material such as lead joint/gaskit joint/CI fitting, nut and bolts,washers and refilling etc complete all as specified . Note:- (i) Excavation up to 1x1x6 Mtr will be deemed to be included in quoted rate. (ii) Jointing material and pipe length will be measured and paid saperately under approriate item of sch 'A' herein.
Arresting of water leakage from existing pipe line in position from GI pipe of size 40mm to 50mm bore ,including excavation through Men/Mechnical power ,cutting threading,welding as per site requirement, incl jointing material such as GI (Bend,socket,reducer,tee,funel, union ,solution,thread etc) and refilling etc complete all as specified. Note :- (i) Excavation up to 1x1x6 Mtr will be deem to incl in quoted rate. More excavation will be measured and paid saperately. (ii) Pipe length will be measured and paid saperately.
Arresting of water leakage from existing pipe line in position from GI pipe of size 15mm to 25mm bore ,including excavation through Men/Mechnical power ,cutting threading,welding as per site requirement, incl jointing material such as GI (Bend,socket,reducer,tee,funel, union ,solution,thread etc) and refilling etc complete all as specified. Note :- (i) Excavation up to 1x1x6 Mtr will be deem to incl in quoted rate. More excavation will be measured and paid saperately. (ii) Pipe length will be measured and paid saperately.
Dismantling to existing unserviceable submersible pump motor of 12.5 HP, 3Phase, 440Volt, 50HZ and Rewinding of stator with PVC insulated copper winding wire including sleeves, thimble & minor spare parts like as bronze bushes, gland packing etc and Re-assembling to the same after motor after repair work . Complate all as specified and as directed by Engineer -in - Charge.
Supply and fix in repair for motor bearing bush (Set of five) for Submersible pump 12.5 HP complete all as specified and as directed.
Supply and fix in repair for stainless steel shaft suitable for submersible pump 12.5 HP complete all as specified and as directed.
Supply and fix in repair for Impeller suitable for submersible pump 12.5 HP complate all as specified and as directed by engineer in charge.
Supply and fix in repair ball bearing as per existing size for motor make: SSK/NBC/SKF
S&F in repair PVC insulated, unsheathed copper conductor cable 10Sqmm, 3Core, Suitable for submersible pump motor complete all as specified and as directed.
Supply and fix in repair add on block of capacity 32 amp MNX-A2 for power contactor.
Supply and Fixing relay capacity of 28 to 32Amp.
Supply and fixing of On load Change over switch, 4 Pole,440 Volts,50 Hz,AC,100 Amps side handle operated conforms to IS 60947-1 & 3 incl making all incoming and out going wires are properly fitted through lugs/thimbles complete all as specified and directed.
Disconnection and removing the unserviceable Automatic star/delta starter and Supply and fixing Automatic star/delta starter in SS enclosure with relay max range 18 to 25 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 40 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed.
Disconnection and removing the unserviceable Automatic star/delta starter and Supply and fixing Automatic star/delta starter in SS enclosure with relay max range 9 to 14 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 40 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed.
Disconnection and removing the unserviceable Automatic star/delta starter and Supply and fixing Automatic star/delta starter in SS enclosure with relay max range 7 to 10 Amps, 415V/440V and 3 Nos of Power Contactors of capacity 40 Amps, Prewired with ON/OFF Buttons complete including connecting the cable all as specified and as directed.
Supply and fixing Indication Lamp set of 3 for RYB & N all as specified and as directed.
Material and labour for Outdoor type Straight through ,jointing kit,cold shrinakable for 11KV grade UG cable 120 Sqmm 3 core Aliminium conductor complete along with jointing material all as specified and as directed by Engr-in-Charge.
Material and labour for Indoor type jointing kit cold shrinakable for 240 Sqmm 3.5 Core 1100 Volts grade LT UG cable end termination with 3.5 /4 Core Aluminium conductor complete along with jointing material all as specified and as directed
Taking down of LT XLPE/ PVC UG cable 1100 V grade, 240 Sqm 3.5 core from the trenches along with cable protection covers/bricks , sand care fully for finding out the fault with the existing sand , PCC covers/Bricks complete all as directed by Engineer - in charge. Note : - Excavation,RFR & PCC covers will be measured and paid seperately under the respective items Note 2:- Unserviceable LT Cable replaced with new cables will be measured and paid seperately Note3:- PCC Cover/bricks and sand protection required for addtional loops of LT cable straight through joints will be measured and paid seperately under the respective items. Note4 : - Excavation,RFR,Sand cushioning cable protection covers and joints required for additional loops and re routing of cables will be measured and paid seperately.
All as per Item No 135 here in above but of 120 sq.mm 3.5 core
All as per Item No 135 here in above but of 95 Sqmm 3.5 Core
All as per Item No 135 here in above but of 50/35/25 Sqmm 3.5 Core
Supply, laying ,connect, test and commisioning of LT UG 240 Sqmm 3.5 Core XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 3.5/ 4 core, 1100 volts, grade complete all as specified and as directed by Engineer - in charge.
All as per Item No 139 here in above but of 120 sq.mm 3.5 core
All as per Item No 139 here in above but of 95 Sqmm 3.5 Core
All as per Item No 139 here in above but of 50 Sqmm 3.5 Core
All as per Item No 139 here in above but of 35 Sqmm 3.5/ 4 Core
All as per Item No 139 here in above but of 25 Sqmm 3.5/ 4 Core
Supply anf fix in repair ACB 4 Pole, 415V, 800 Amp 50KA, with thermal magnetic release (manual drawout type) complate all as Specified and as directed.
Supply and fix in repair CT/PT 800/05 400Amp complete all as specified and as directed by Engineer - in charge.
M&L for earthing complete with galvanized steel earth plate electrode 600mmX600mmX6mm thick buried drectly in ground Verticaly to a depath not less than 2.25mtr deep below normal ground level with top edge of earth plate at a depth of not less than 1.5mtr below normal ground level connected to galvanized iron strip 32mmX6mm by means of bolts, nuts, check nuts and washers made out of galvanized iron and GI earth strip protected by 40MM bore light grede GI Pipe as well as 20mm dia medium grade pipe 1.5mtr fixed with funnel and wire mesh as Specified and connected allas shown in electrical plate No 03 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1:2:4 type B-1 in chamber and 40mm thick 1:2:4 type B-1 cover slab with 6mm dia mield steel bars at 100mm center to center both way with 6mm dia MS hooks complete all as specified and as directed.
Supply & fix Indoor Type LT panel board outdoor type double door wall mounted made out of 3mm thick CRCA sheet Steel for load bearing and 2 mm thick for non load bearing and portions mounted on frame angle iron fo suitable size weather proof/veermin proof shutter type with locking arrangment of cubical type prewired with aluminium extendable busbar 200 Amps for 03 phases and aluminium busbar 200 Amps for neutral including suitable CTs etc and powder coated paited, agle iron frame base (90CMX75CMX30CM) with provision for fixing of MCCB's mounting arrangement shall be adjustabile type,Comprising of following complete all as specified. Make of the Panel board confirming to CPRI specifications only. (i) MCCB 125 Amps, Breaking capacity 35 KA, 4 pole -1 No (In coming) Make: legrand (ii) 4Nos Aluminium Bus bar of Capacity 125 Amps for Phase & Neutral (iii) MCB SP 6-32 Amp - 40 N0s (out going) Make - legrand (iv) LED/Neon indicator bulb in RYB Colour - 1 Set.
Supply, fixing & testing of Solar water tank made out of stainless steel alongwith PUF insulation of capacity 100 litre with electrical heating backup of 2 KW as per existing make including taking down old unserviceable solar water tank complate all as Specified and as directed by Engg-in-charge.
M/s Friends Engineering Works (BID ID -3164849)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .