| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAdmitted-Finance 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | ₹1.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.8 Cr+₹5.0 L (2.88%)Admitted-Finance KARNATAKA | ₹1.8 Cr+₹5.0 L (2.88%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Qualified as per NIT conditions. |
| Sl No | Description | Qty | Unit | JAI ENTERPRISES L2 | ABHISHEK INTEGRATIONS LIMITED L1 |
|---|---|---|---|---|---|
| 1.00 | Deployment of engineer as per Document Name- Shift Engineer | 1,200 | job | 3,973 ₹47,67,600 | 1,316 ₹15,79,200 Lowest |
| 2.00 | Deployment of Electrician/ Lineman as per Document Name- Electrician | 1,300 | job | 2,683 ₹34,87,900 | 1,213 ₹15,76,900 Lowest |
| 3.00 | Deployment of Trade Helper as per Document Name- Trade Helper | 1,200 | job | 1,963 ₹23,55,600 | 998 ₹11,97,600 Lowest |
| 4.00 | Annual Maintenance ,Testing and servicing of 20MVA, 132kV/11KV transformer as per Document name: AMC | 2 | No. | 2,22,333 ₹4,44,666 Lowest | 3,23,750 ₹6,47,500 |
| 5.00 | Annual Maintenance ,Testing and servicing of 800KVA 11kV/433V TRANSFORMER as per Document name: AMC | 2 | No. | 25,223 ₹50,446 Lowest | 1,13,750 ₹2,27,500 |
| 6.00 | Annual Maintenance ,Testing and servicing of 132KV SF6 GAS BREAKER as per Document name: AMC | 5 | No. | 75,733 ₹3,78,665 | 43,750 ₹2,18,750 Lowest |
| 7.00 | Annual Maintenance ,Testing and servicing of 132KV 3phase isolator with or with out earth switch as per Document name: AMC | 21 | No. | 29,923 ₹6,28,383 Lowest | 43,750 ₹9,18,750 |
| 8.00 | Annual Maintenance ,Testing and servicing of 132KV CT/PT as per Document name: AMC | 24 | No. | 32,133 ₹7,71,192 Lowest | 43,750 ₹10,50,000 |
| 9.00 | Annual Maintenance ,Testing and servicing of Numerical PROTECTIVE RELAYS as per Document name: AMC | 50 | No. | 4,543 ₹2,27,150 Lowest | 26,250 ₹13,12,500 |
| 10.00 | Annual Maintenance ,Testing and servicing of Electromagnetic/ Electromechnical relays as per Document name: AMC | 130 | No. | 3,993 ₹5,19,090 Lowest | 6,125 ₹7,96,250 |
Tender Value
₹2.4 Cr
EMD Value
₹4.9 L
Closing Date
10 Sept 2025, 3:00 pmClosed
Project Director, BARC(V)
BARC Main Site, Visakhapatnam.
Annual Operation and Maintenance for 132kV/11kV substation and its associated LT systems at UC-02, BARCF, Visakhapatnam.
2025_BARC_872453_1
BARC-V/ESS-V/2025/14
Open Tender
Electrical Works
Item Rate
365 days
BARC main Site, Visakhapatnam.
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹4.9 L
6 Nov 2025
12 Aug 2025
18 Sept 2025
12 Aug 2025
10 Sept 2025
27 Aug 2025
12 Aug 2025 - 25 Aug 2025
Amount
Deployment of engineer as per Document Name- Shift Engineer
Deployment of Electrician/ Lineman as per Document Name- Electrician
Deployment of Trade Helper as per Document Name- Trade Helper
Annual Maintenance ,Testing and servicing of 20MVA, 132kV/11KV transformer as per Document name: AMC
Annual Maintenance ,Testing and servicing of 800KVA 11kV/433V TRANSFORMER as per Document name: AMC
Annual Maintenance ,Testing and servicing of 132KV SF6 GAS BREAKER as per Document name: AMC
Annual Maintenance ,Testing and servicing of 132KV 3phase isolator with or with out earth switch as per Document name: AMC
Annual Maintenance ,Testing and servicing of 132KV CT/PT as per Document name: AMC
Annual Maintenance ,Testing and servicing of Numerical PROTECTIVE RELAYS as per Document name: AMC
Annual Maintenance ,Testing and servicing of Electromagnetic/ Electromechnical relays as per Document name: AMC
Annual Maintenance ,Testing and servicing of 11 KV Panels with VCB as per Document name: AMC
Annual Maintenance ,Testing and servicing of LT Air circuit breakers & MCCB'S as per Document name: AMC
Annual Maintenance ,Testing and servicing of EARTHING SYSTEM as per Document name: AMC
Annual Maintenance ,Testing and servicing of Battery banks with battery chargers /UPS as per Document name: AMC
Filtration of transformer Oil OF 20MVA 132KV/11KV TRANFORMER containing approximately 15KL oil till its BDV value reaches above 60KV or as per relevant IS
Filtration of transformer Oil OF 800KVA 11KV/433V TRANFORMER containing approximately 1.5KL oil till its BDV value reaches above 50KV or as per relevant IS
Supply and installation (Replacement)of 132kV CT as per Document name: CT
Supply and installation (Replacement) of 132kv PT as per Document name: PT
Supply and installation(Replacement) of 132KV LA as per Document name: LA
supply and installation (Replacement) of disk insulators (string insulator) as per Document name: String insulator
Supply and installation (Replacement)of 132kv post insulators as per Document name: post top insulator
Supply of sf6 gas cylinder of 7kg for 132kV SF6 GAS CIRCUIT BREAKER along with filling connector make: SIEMENS
supply , installation(replacement) of 11KV HT switch Board/cable termination bus Bar Support insulators
supply , installation(replacement) of11kV PT-Potential transformer as per Document name:11kV PT
supply , installation(replacement) of 11kv pt fuse as per Document name:11kV PT FUSE
supply , installation (replacement) of Current Transformer (1600-800/1) as per Document name: 11kV CT 1
supply , installation(replacement) of Current Transformer (300-150/1) as per Document name: 11KV CT2
supply and installation(Replacement) of vrla battery 2v, 100 ah suggested make EXIDE/AMARON
supply and installation(Replacement) of flooded lead acid(plante) 2v, 100 ah suggested make EXIDE/AMARON
Supply of fresh (virgin oil ) mineral Transformer oil with BDV 60KV and water content less than 15 ppm shall be conforming to IS:335(latest), filling of transformer oil as & when required for oil type transformers at various locations .
Supply of dry Silica gel (with orange colour in dry condition) having PH value 6-7 in particles of 2mm to 4 mm size & replacement in transformer breathers at various locations .
Supply and installation of clean cotton waste containing scrap cloths.
supply and installation of distilled water/ demineralised with PH : 6 to 7.5 in battery
Supply and installation of Silicone sealants along with applicator
supply and installation of straight through joint For 3 C X 400 Sq. mm - 11kV 3 core 400 SQMM , xlpe, wire armoured, earthed system, copper suggested make: EPKJ 3118 of M/s Raychem or Equivalent models of M/s 3M. The work includes Supply, installation of straight through joint kit , removing and placing back in position of concrete/ MS trench( which can weigh above 1ton) , cable dressing, cable pulling etc., to complete installation.
supply and installation of 11kV 3 core,400 SQMM , xlpe, wire armoured copper end termination kit, earthed system For 3 C X 400 Sq. mm - suggested make: EPKT 3131 of M/s Raychem or Equivalent models of M/s 3M. The work includes Supply, installation of straight through joint kit , removing and placing back in position of concrete/ MS trench ( which can weigh above 1ton) , cable dressing, cable pulling etc., to complete installation.
laying of copper or alumimnum 11kV 3 core,400 sqmm, xlpe,wire armoured cable/1.1kv 3.5 core, 400 sqmm, xlpe, wire armoured in trenches, including lifting of concrete trench covers ( which can weigh above 1ton) , and placing back in their original place.
Supply &installation(Replacement) of 4 Pole MCCB ,400A ,50 KA. make : L&T
Supply &installation(Replacement) of 4 Pole MCCB ,125A, 36 KA with replacement of leads from bus-bar to MCCB terminal .make : L&T
Supply & installation(Replacement) of 4 Pole MCCB 63A, 36 KA with replacement of leads from bus-bar to MCCB terminal .make : L&T
Supply & installation (Replacement) of 3 Pole MCCB ,40A ,36 KA. make : L&T
Supply & installation(Replacement) of 3 Pole MCCB ,16A, 36 KA with replacement of leads from bus-bar to MCCB terminal .make : L&T
supply and installation(Replacement) of electrical panel Indicating lamps( LED) SIZE:22.5mm, AC/DC (as per site requirement.) suggested MAKE:L&T
supply & installation(Replacement) of panel door locks with keys
Supply & replacement of Shunt release coil for 63A/125A/200A/400A MCCB ( coil voltage: 230V )
Supply and installation(Replacement) of LT cable straight Jointing kit for1.1kV, 3.5 core 400 sq mm. aluminium cable (Heat shrinkable) suggested MAKE: M/s Raychem or M/s 3M
Detecting the fault of underground HT/LT XLPE cable by fault locator machine and repairing of damaged cable
supply and installation of auxiliary contact multiplier relay , control supply voltage 220V DC, auxiliary contact 2 NO+2 NC, auxiliary contact current rating 10 amps . Installation shall include mounting of relay, cable lugging, screws etc., to make relay fully functional. Suggested make: SIEMENS, L&T,SCHNEIDER ELECTRIC
Supply and installation/replacement of Brass double compression gland for (82 mm) 3½ X 400 sq. mm 1.1 KV grade cable
Supply and installation/replacement of Brass double compression gland for (62 mm) 3½ X 240 sq. mm 1.1 KV grade cable
Supply and installation/replacement of Brass double compression gland for (50 mm) 3½ X 150 sq. mm 1.1 KV grade cable
Supply and installation/replacement of Brass double compression gland for (45 mm) 3½ X 120 sq. mm 1.1 KV grade cable
Supply and installation/replacement of Brass double compression gland for (38 mm) 3½ X 70 sq. mm 1.1 KV grade cable
Supply and installation/replacement of Brass double compression gland for (35 mm) 3½ X 50 sq. mm 1.1 KV grade cable
Supply and installation/replacement of Brass double compression gland for (32 mm) 3½ X 35 sq. mm 1.1 KV grade cable
Supply and installation/replacement of Brass double compression gland for (28 mm) 3½ X 25 sq. mm 1.1 KV grade cable
Supply and installation/replacement of Ring Tubular Type Copper lug for 400 sq. mm , 3.5 core cable
Supply and installation/replacement of Ring Tubular Type Copper lug for 240 sq. mm ,3.5 core cable
Supply and installation/replacement of Ring Tubular Type Copper lug for 150 sq. mm ,3.5 core cable
Supply and installation/replacement of Ring Tubular Type Copper lug for 120 sq. mm ,3.5 core cable
Supply and installation/replacement of Ring Tubular Type Copper lug for 70 sq. mm ,3.5 core cable
Supply and installation/replacement of Ring Tubular Type Copper lug for 50 sq. mm ,3.5 core cable
Supply and installation/replacement of Ring Tubular Type Copper lug for 35 sq. mm ,3.5 core cable
Supply and installation/replacement of Ring Tubular Type Copper lug for 25 sq. mm ,4 core cable
Supply and installation/replacement of Ring Tubular Type Copper lug for 16 sq. mm, 4 core cable
Supply and installation/replacement of Pin Type Copper lug for 16 sq. mm,4 core cable
Supply and installation/replacement of Pin Type Copper lug for 25 sq. mm ,4 core cable
Supply and installation of of Earth pit with MS rod 40 mm dia as per IS: 3043.
Supply and installation(Replacement) of LED luminaries ,240 volts, 50 hz, pf more than .94, TLD LESS THAN 11%, 200 watts, 24000 lumen, aluminum die cast, cradle mount, IP 66 along with driver model: wipro LF 30 FLOOD LIGHT or equivalent
Supply and installation(Replacement) of LED luminaries ,240 volts, 50 hz, pf more than .94, TLD LESS THAN 11%, 120 watts, 16200 lumen, aluminum die cast, suspended mount, IP 65 along with driver model: wipro LH 192-060 High bay LIGHT or equivalent
Supply and installation(Replacement) of driver for LED luminaries ,240 volts, 50 hz, pf more than .94, TLD LESS THAN 11%, 200 watts, 24000 lumen, aluminum die cast, cradle mount, IP 66 along model: wipro LF 30 FLOOD LIGHT
Supply and installation(Replacement) of driver for LED luminaries ,240 volts, 50 hz, pf more than .94, TLD LESS THAN 11%, 120 watts, 16200 lumen, aluminum die cast, suspended mount, IP 65 along with driver model: wipro LH 192-060 High bay LIGHT
Supply and fixing of LED Batten Light 20 Watt .
supply and fixing of LED batten light 36W
supply and fixing of LED Batten Light 10 Watt .
Servicing of exhaust fans of 450mm sweep, single phase including cleaning ,greasing , replacement of bearings .
supply and installation (Replacement) of 450mm sweep ,150 watt, single phase ,18 inch, industrial exhaust fans, noise less than 60 db.
Supply & installation(Replacement) of 4 pole 63A,10 KA MCBs.
Supply & installation(Replacement) of 2 pole 32A,10 KA MCBs.
Supply & installation(Replacement) of 4 pole 32A,10 KA MCBs.
Supply & installation(Replacement) of 4 pole 63 Amps ,30 mA,RCCB.,10 KA
Supply & installation(Replacement) of 2 pole 32/40 Amps ,30 mA,RCCB.,10 KA
Supply & installation(Replacement) of 2 pole 63A 30mA , RCCB,10 KA
Small bushes/ wild vegetation clearing for street light poles / 11 KV/ 132KV structures /switch Yards or at any necessary area.
Supply & Installation of Multi-lingual Danger Boards/caution boards/first aid board of size 600mmx600mm on metal sheet or pvc board
Excavation of earth in all types of soil .
supply and installation of 1:2:4 PCC
Supply & Replacement of PCC SLABS 500mmx500mmx20mm for earth pit covers
supply, fabrication and installation of MS angles, channels/ chequered plates etc.,
supply, fabrication and installation of GI FLATS / GI TRAYS/ GI BOLTS NUTS/ GI PIPES / angles, channels etc.,
supply and installation of paint after cleaning surface with wire brush to remove dirt and rust zinc rich primer (2 no of coats) and one coat of polyurethane paint of minimum 50 micron.
JAI ENTERPRISES (BID ID -3278484)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .