Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹42.7 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹47.4 L+₹4.7 L (10.9%)Rejected-AOC | ₹47.4 L+₹4.7 L (10.9%) | L2 | Rejected-AOC REJECTED |
| 3 | L3₹47.6 L+₹4.9 L (11.5%)Rejected-AOC SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | ₹47.6 L+₹4.9 L (11.5%) | L3 | Rejected-AOC REJECTED |
| 4 | L4₹47.7 L+₹5.0 L (11.6%)Rejected-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | ₹47.7 L+₹5.0 L (11.6%) | L4 | Rejected-AOC REJECTED |
| 5 | L5₹47.7 L+₹5.0 L (11.7%)Rejected-AOC | ₹47.7 L+₹5.0 L (11.7%) | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
15 Dec 2022, 6:00 pmClosed
GE I CG PORBANDAR
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVN OF ACCN FOR INSTALLATION OF RING MAIN UNIT (RMU) AND OTHER CONNECTED ITEMS AT CGAE
2022_MES_565153_1
8804
Open Tender
Civil Works
Item Rate
180 days
PBR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE I CG PORBANDAR
₹77,000
Yes
11 Jan 2023
25 Nov 2022
16 Dec 2022
25 Nov 2022
15 Dec 2022
9 Dec 2022
Amount
SCHEDULE 'A'
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm area on plan and n exc 1.5 m in depth and getting out Soft/disintegrated rock all as specified.
M&L for Plain Cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in foundation filling and mass concrete complete all as specified.
M&L Reinforced cement concrete 1:1.5:3 Type A1, using 20 mm graded aggregate) in foundation, footing, foundation beams, plinth beams, base of columns complete all as specified and as directed.
M&L Reinforced cement concrete 1:1.5:3 Type A1 (20 mm graded aggregate) Columns, pillars, piers, posts and struts . Complete all as specified and as directed.
M&L for Reinforced cement concrete 1:1.5:3 Type A1 using 20 mm graded aggregate)as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M&L for Reinforced cement concrete 1:1.5:3 Type A1, (using 20mm graded aggregate) for chajjas, complete all as specified and as directed
M&L for Reinforced cement concrete 1:1.5:3 Type A1 using 20 mm graded aggregate) in slab supported on walls, complete all as specified and as directed.
M&L for Formwork to flat sides with fair finish surface of concrete foundations, footings, bases of columns, raft and raft beams sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter
M&L for Formwork to sides of pillars,posts, struts, piers, columns and stanchions with rough finish surface complete all as specified and directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges as in rough finished surfaces of concrete complete all as specified.
Form work to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200 mm thick in sloping.
Form work to sides and soffits of floor or roof beams, beam haunching,lintel etc.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed.
all as per item No. above, but 6mm to 8mm dia. complete all as specified and as directed.
all as per item No.13 above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soft/disintegrated rock.
Removal of excavated rocks exc. 250m but n.exc 500 mtr and depositing where directed at level n exc. 1.5M above the starting point. all as specified.
M & L for Porbandar stone masonry, well bonded, bedded and solidly hearted built in CM 1:6 all as specified and as directed by Engineer-in-charge.
M&L for rendering 10 mm thick on fair face of brick work or concrete surfaces in CM 1:6 finished even and smooth wiithout using extra cement.
M&L for rendering 5mm thick cement plaster in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on ceiling in any height complete all as specified and directed.
M&L moorum/red bajri filling in floors or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed by Engr-in-charge
M&L for broken stone or boulders Hardcore of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified.
M&L for rendering 15mm thick, cement plaster, in cement mortar (1:4) mixed with integral water proofing compound as per manufactures instruction, on roof slab surfaces finished even and smooth without using extra cement,complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately) Under respective item of this schedule.
M&L for providing APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely. (ii) Applying APP based pre-fabricated with non woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method. (iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10Kg/Sqm over mineral surface.
M&L for rendering 15mm thick, cement plaster, in cement mortar (1:4) mixed with integral water proofing compound as per manufactures instruction, on fair faces of brick walls or concrete surfaces finished even and smooth without using extra cement in any height, complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately) Under respective item of this schedule.
Supply only water proofing compound (integral) all as specified & directed.
S&F powder coated aluminium anodised three track sliding window shutter and frame including jointing clit for fixing frame/chowkhat of window as per JINDAL section code (frame 20831), shutter (20846) including glazing with 5mm thick tinted glass & Aluminium wire mesh necessary fittings, rubber packing, suitable handles, rollers for shutters etc complete all as specified and as directed.
S&F powder coated aluminium grill with suitable aluminium anodised frame F/H section manufactured by M/s DECO GRILL as per design No DG-104, 6 mm thick complete all as specified and as directed.
S & F for Steel rolling shutters, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull or manual type , thickness of laths 1.25 mm complete all as specified and as directed.
M&L for Aplying two coat of anticrosive paint on steel surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified .
M&L for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as per the manufacturers instructions, complete all as specified and directed by Engr-in-charge.
M&L for preparation of surfaces and applying two coat of OBD over a coat of primer on new plastered surfaces of wall complete all as specified and as directed.
M&L for preparation of surfaces and applying two coat of white wash on new plastered surfaces of ceiling complete all as specified and as directed.
M&L for 75mm thick Cement concrete 1:3:6, type C2 (using 40 mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate 75 mm thick as in sub base complete all as specified .
M&L for PCC (1:2:4) type B1 using 20 mm graded aggregate as in floor of average 25mm thick complete all as specified .
M&L Machine cut kota stone slab flooring 20-25mm thick over and in 15 mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
all as per item ser no 37 here-in-before but in skirting/dado or verticle surfaces with back coat of screed bed or bedding layer of 10 mm thick 1:4 complete all as specified.
M & L for 60 mm thick M-35 Grade Machine pressed precast concrete paver block of any colour any shape and size confirming to IS 15658-2006 with grey cement and pigment complete all as specified and as directed.
M & L for 50 mm thick Sand filling under floors or in foundation including watering and consolidation complete all as specified .
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete using Fe-410-W( Gde E-250) quality-A complete all as specified .
S&F for PVC coated 4 mm dia galvanised steel wire mesh of aperture 100 x 100 mm made up into mattresses or cages, lapped, wired and laid in position, incl closing after filling complete including line wire complete all as specified and as directed.
S&F for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm and n exc. 10 cm long with 5 to 10mm dia of neck complete all as specified .
S&F Hand rails, half round or other stock section or core for woode hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concreteand screwing etc. wind ties for roof including securing bolts etc complete
Supply ainstallation, comissioning & testing of outdoor type nonextensible 11 KV, SF6 insulated compact ring main unit (RMU) with short circuit peak mating current 50 KA and short circuit breaking current 20 KA fully arc proof metal encloused free standing floor mounting motorised operated fixed type SF6 insulated, 2 Nos. Load break switches 400 Amps (as incoming) and 1 No SF6 circuit breaker 200 Amps ( as outgoing) with self-powered micro-processor based relays (as and related CTs, cable switch module and an interlocking mechanism with the earth switches, degree of protection IP 54 with the following components complete all as specified and directed. Make ABB/ SCHNIEDER/ C&S (a) 2mm stainless steel tank filled with SF6 comprising of 2 Nos isolators and 1 No SF6 circuit breaker (b) Blank (c) Self-powered micro processor controlled numeric relay comprising of 02 pole over current, one pole earth fault protection relay (e) Manual push button for emergency trip (d) Internal bus earthing with fat copper strip of size 50x6 mm. (f) Copper bus bar. (g) Manual mechanism. (h) Front access & bottom entry of HT cables (j) In case of bus bar extension the same should be achievedthrough "plugin bus bars only, bolted type bus bars are not acceptable (k) The bus bar should be extendible and connectable within the heath of the awitch gears, the bus bars should not exceed the size of RMU/Cubicle (l) The cable box should have bottom gland/base plata for cable entry and front cable covers for cable access (m) The live line indicators should be of LCD display type due to their higher life taking the required power from the capacitive coils situated at as the cable bushings (n) Manometer (o) Mechanical indication in the front in the mimic for open & close breakerisolator/ earth switch (p) Operating handle
Supply. Installation & commissioning of factory made,CPRI approved manufacturer, self supporting totally enclosed LT Panel Board (in door type) confirming to IP-55 compartmentalized design, dust & vermin proof for 440 Volt 3 phase 4 wire system madeup of GI sheet of 2.0 mm thick built upin rigid frame work having front and rear hinged door with neoprene rubber gasket, epoxy powder coated including danger plate, earth strip point and ventilation louvers at the rear side, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers, etc. having control circuit diagram with colour code solid conductor copper 1.5 sqmm cable for easy identification including Incoming/ Outgoing cable entry provisions, embeded with 50x6mm mild steel angle Iron frame and 200 mm above the normal ground level complete with PCC foundation in cement concrete 1:2:4 (20mm graded stone aggregate) and testing after installation including taking down unserviceable LT panel board complete all as specified and comprising with the following: Make: C&S/Legrand/Sigma Control System/Advance. (a) Copper Bus Bar of size 50x4mm, rating 800 Amps, supported with suitable size of heavy duty porcelain standblock with suitable size brass nut bolts and washers with heat shinkable PVC sleeving The Bus Bar shall be colour coded (Red, Yellow & blue) for 3 phase and Black for Neutral (b) Incoming MCCB 630 Amps four pole with Thermal magnetic release, having breaking capacity 35 KA-01 No, (c) Outgoing MCCB 250 Amps four pole with Thermal magnetic release, having breaking capacity 25 KA, 02 No (d) Outgoing MCCB 125 Amps four pole with Thermal magnetic release, having breaking capacity 25 KA-01 No. (f) MCB TPN 4 Pole 415 Vat 63 Amps-2 (g) MCB DP 230 Volt 6-32 Amps-2 No (h) Digital Voltmeter 0-500 V 95x96m-01 nos (j) Digital Ammeter 0-500 A 96x95m--01 nos (k) Indicating Lamps set RYB-01 set (l) MFM-01 Nos Note:- (i) cost of PCC foundation as per manufacturer specification to be included in the nuit rate. (ii) Cost of connecting incoming and outgoing cables along with necessary nut, bolts & clamps and cable lugs as per size of cable in included.
Disconnecting and Shifting of 500 KVA transformer from Existing Power House to New E/M installation bldg near New Hangar and proper connection of HTLT side and all as directed
Supply, laying & testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty)with stranced aluminium conductor 11000 volts grade, of size 3 core 120 sq mm
Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium) conductor of size 120 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy dut) 1100 Volts grade with stranded aluminium) conductor of size 300 sq mm 3.5 core
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 70 sqmm to 120 sqmm.
M&L for bore Earthing, 150 mm bore for earthing with maintenance free chemical earthing using copper electrode of size 19 mm dia - 01 No, 3 m long, Copper earth strip, excavation and earth work, back fill with compound (Chemical for earth enhancer gel 2 x 25Kg)-01 set all as directed, shall be deemed to be included in the unit rate. Note: (1) IR Value should be less than 1.0 ohm. (ii) Copper earth stip of size 20 x 3.15 mm including installation 7.5 Mtr (Copper purity not less than 99%) is deemed to be included in the unit rate. (iii) Suitable FRP Chamber should be included in the unit rate.
M&L Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size
M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment
Supply, Installation Testing & commissioning of DRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS 16583 with ISI marked/TAC approved fitted with quired accessories including wall suspension brackets
Supply Instalation Testing & commissioning of Trolley Mounted DRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 25 Kg confirm to IS 15683, with 151 macked/TAC approved fitted with required accessories including wan suspension brackets
Supply, installation, Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS 15683 with 151 marked/TAC approved fitted with required accessones including wall suspension brackets
Supply and instalation at approved location approved make Fire sand bucket of 24 gauge galvanized steel sheet, each set shan have 4 buckets with stand & Showel etc complete all as specified and drected
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil complete all as specified and directed.
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply and lay 90/76 mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. Make: Rex/Poly/Gemini
Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:-
(a) One light/fan point controlled by one, one way switch
(b) One 3 pin 6 Amps socket outlet on same board
(c) One 3 pin 6 Amps socket outlet on independent board .
Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame for modular switches, sockets, switch sockets for one 3 pin 15 or 16 Amps on independent board with required modules all as specified. insulated but unsheathed multistrand copper conductor FRLS cabel 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 1.5 Sqmm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board as specified. Note for item no 1/2 :- Cost of cutting / chasing on wall and making good after repair deemed to be included in unit Rate
S & F stepped type electronic fan regulator modular type on the existing phenolic laminated sheet etc. as reqd.
S & F Switch piano, modular type single pole, one way 5 Amp as rqd.
S & F Switch piano, modular type single pole, one way 15 Amp as rqd.
S & F Socket outlet 2 in 1, 3 pin, 5 and 15 amp modular type as rqd.
S & F Socket outlet 2 in 1, 3 pin, 5/6 amp modular type as rqd.
Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Material & labour for Sub main wiring with two runs of 2.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable,fire retardant low smoke drawn through and including PVC concealed conduit heavy duty grade ISI marked 25 mm dia (external) but shall be increased as per actual site requirement in accordance,with wall thickness not less than 1.8 mm complete with all necessary fitting and including with conduit accessories and one run of 2.5Sqmm single core PVC insulated but unsheathed multistranded copper conductor 1100 volts grade cable fire retardant low smoke as earth wire conductor, fixed on wall/ceiling including taking down old unserviceable sub main wiring complete all as specified and as directed Note :- Cutting chases for fixing of concealed conduit will measured and paid separetely.
S & F Sheet metal enclousure Double door for MCB DB single pole and neutral 04 way complete all as specified and as directed.
Supply,and fixing MCB SP 6-32 Amp complete all as specified
Supply,and fixing MCB SPN 6-32 Amp complete all as specified
Supply,and fixing Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified
SURAJ ENTERPRISE
vijay infraprojects pvt ltd
SURESH ELECTRICALS
jitendra c joisar
RAJESH ENTERPRISE
M/s SK Traders
OM ENGINEERING
fakhrie apostrical
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .