Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.4 LAccepted-AOC 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | L1 | Accepted-AOC Being L1 and found in order | |
| 2 | L2₹75.8 L+₹1.4 L (1.87%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | Rejected-Technical 149 KHAJURI HARIDWAR UTTARAKHAND 247668 | HARIDWAR | UTTARAKHAND | 247668 | - | Rejected-Technical Criteria not fulfilled as per NIT, Tender Cost and earnest money not received in physical form | |
| 4 | Rejected-Technical 54 AKASHDEEP COLONY CHAKRATA ROAD DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | - | Rejected-Technical No in WLR |
Tender Value
₹65 L
EMD Value
₹1.2 L
Closing Date
3 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer Bareilly Zone
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan, Station Road Bareilly Cantt Bareilly - 243001
COMPLETION OF INCOMPLETE WORK FOR COMPLETION OF INCOMPLETE WORK FOR PROVISION OF SECURITY WALL AT RIMC DEHRADUN
2020_MES_386950_4
CEBZ/DDN/T-09 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (P) Dehradun
₹1.2 L
Yes
1 Dec 2022
5 Sept 2022
10 Oct 2022
5 Sept 2022
3 Oct 2022
12 Sept 2022
6 Sept 2022 - 9 Sept 2022
Amount
B/R Items
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and exc. 1.50 m but not exc. 3.0 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in any type of soil complete all as specified and directed.
Excavation over areas not exc. 1.50 m deep and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Spreading and levelling of soil in layers not exc. 25 cm thick including well ramming and watering as required complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out, returning, filling and ramming earth or broken rubble mixed with earth around in layers not exc. 25 cm watering and removing surplus soil to a distance not exc. 50 m and making good surface as in hard / dense soil complete all as specified and directed.
Excavation and cutting in PCC/Bitumen road for laying of LT cable through GI Pipe and making good with PCC 1:2:4 type B-1 and finishing to the existing complete all as specified and directed.
M&L river washed and screened dry sand filling in trenches below and above/around under ground cable for cushioning of cable complete all as specified and directed.
M & L for providing plain cement concrete, type E-2, 1:5:10 (using 40 mm graded stone aggregate) as in foundation, filling, 100 mm thick as in sub base and mass concrete complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, kneelers, apex stones, bed plates, water troughs,plinth block and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate, as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and directed.
M & L for providing pre-cast cement concrete in door or window cills, lintel, bressumers, bed plate, apex stone, pintle blocks, bonders (For stone masonry) and similar items with plain faces including chamfers, weathering, throating etc. in cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate and setting in cement mortar 1:6 complete all as specified and directed.
M & L for providing pre-cast reinforced cement concrete (RCC) 1:2:4 type B-1, (using 20 mm graded stone aggregate) as in fencing posts, struts etc., average sectional area exc. 100 Sqcm but not exc. 250 Sqcm with or without chamfered angles and flat, splayed, rounded or mitred tops complete all as specified and directed.
M & L for cement concrete 1:3:6, type C-1 (using 20 mm graded stone aggregate) as in bed to drain pipes of 600 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
M & L for laying bricks on edges, using sub class ‘B’ old size bricks, bedded and jointed in cement mortar 1:6 and pointed in cement mortar 1:3 as in floor, berms etc. including matching the edge of berm with camber/gradient of surface of road with necessary required earth filling complete all as specified and directed.
M & L for continuous brick edging, with width equal to the width of brick using sub class ‘B’ old size bricks laid dry on end vertically including embedding bricks in the ground, temping ground around bricks and removal of surplus soil complete all as specified and directed.
M&L bricks sub class 'B' old size well burnt bricks, laid flat with width equal to the length of bricks, laid dry on sand for providing protection cover to the under ground cable all as specified and directed.
M&L walling random rubble brought upto course, well bonded, bedded & solidly hearted, built in CM 1:6 complete all as specified and directed
M & L precast cement concrete bonders using PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for stone walling and set in CM 1:6 including necessary form work etc, complete all as specified and directed.
M & L for use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions in fair finished surface of concrete complete all as specified and directed.
M & L for use and waste of form work to conceret foundation, footings, bases of columns and plinth beam etc. in fair finished surface of concrete complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and fair complete all as specified and directed.
M & L for 15 mm thick rendering on other than fair faces of brick work or stone masonry surfaces with cement mortar 1:6 finished even and fair complete all as specified and directed.
M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
M & L raised pointing to random rubble uncoursed or brought upto courses stone masonry in CM 1:4 complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel deformed or twisted bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F of mild steel work in hand rail for fixing of wooden hand rails, baluster, running bars, nosing of steps, wind ties, post and struts for fencing, flat iron fillets and the like including necessary cutting, drilling holes, notching etc. as required conforming to Fe - 410 - O or Fe - 310 - O complete all as specified and directed.
S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe-410-O or Fe-310-O complete all as specified and directed.
S & F of galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, straining bolts at ends, staples or steel pins etc. complete all as specified and directed. Note:- Each line of wire shall be measured separately.
S&F 900mm dia of concertina coil alongwith straight line of RBT(Supporting material as concertina coil) coils of standard specification i.e. 56 number of circles, 13-14 Kg of weight and 12-14 RMtr coverage per coil (Central core wire 2.6 mm dia hot dip galvanised spring steel high tensile core wire, barbed rezor strip 19 mm wide before warping on central core wire 0.50 mm thick low carbon and rolled steel tape with razor sharp barbs at close intervals and zinc coating 120 gm/sqm, stainless steel barbed razor strip 0.4 mm AISI 304 material, clips - GI 12 mm thick, GI handles and iron spikes on both ends and complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint complete all as specified and directed.
M & L for preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L for black bituminous paint to surface of any description wood steel, iron, concrete, wood etc exc 10 cm width or girth complete all as specified and directed.
S& F of 600 mm bore reinforced concrete pipe class NP-2, laid and jointed with collar complete all as specified and directed.
Defective Works
M&L for flush pointing in CM 1:4 in sub class 'B' bricks laid flat, in floors complete all as specified and directed.
Taking down plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) laid bedded and pointed in mortar complete all as specified and directed.
Demolition of cement concrete on any description and in any position not otherwise specifically provided for complete all as specified and directed.
E/M Items
M&L for tubing light grade galvanised iron laid under roads/drain/ wall, fixed to poles complete all specified and directed of following sizes :-
(a) 80 mm bore
(b) 40 mm bore
Note :- Excavation and earth work will be measured and paid separately.
Fixing in true vertical position steel tubular pole 11m long complete, cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55, confirming to IS-2713 to 1980 with and including two coats of aluminium paint over a coat of red oxide primer 03 No band/strap with white and red post office box colour (300mm wide each) in alternative layer from plinth block and red post office synthetic enamelled paint 1.5M from top and marking pole No with black synthetic enamelled paint 2.5 CM height including tarring one coat on steel surface embeded in concrete foundation complete all as specified and directed. Note :- Steel tubular poles 410 SP-55, 11 m long with MS base plate and pole cap (04 Nos) have been left out by the previous contractor and will be issued to the contractor free for fixing only under Sch 'B'.
Note :- Excavation and earth work will be measured and paid separately.
M&L for danger notice plate of 1.6mm thick mild steel of size 250 mm x 200 mm for HT vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with and including MS clamps bolts and nuts complete all as specified and directed.
M&L for Anti-clambing devices comprising 2.24mm dia GI steel 2 strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 Mtr clamp and properly secured or as ordered complete all as specified and directed. (Clamps messured seperately).
Earthing with galvanised steel earth plate 600 x 600 x 6 mm thick buried directly in the ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5 m below ground level connected to galvanised iron earth wire 4 mm dia by means of bolts, nuts, checknut and washers of galvanised iron or steel, GI pipe 15 mm dia light grade for protection of earthing strip, PCC 1:4:8 type D-2 chamber using 40 mm graded stone aggregate, 0.63 mm PGI sheet funnel with GI wire mesh, 50 mm thick RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) cover reinforced with 8 mm dia for steel round bars, charcoal dust and common salt all as per electric plate No 3 of SSR part I including excavation and earth work and connection with earth lead for equipment, complete all as specified and directed.
M & L cross arms, bracing, supports, clamps and plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and finishing coat of paint complete all as specified and directed.
Supplying, laying, jointing and testing LT underground cable XLPE insulated, screened , PVC bedded, galvanised steel strip armoured, heavy duty electric power cable with aluminium conductor, 1100 volts grade pressure earthed system laid in trenches/ duct, on pole, in GI pipe, under culvert, drains, road etc. complete all as specified and directed for the following sizes:-
(i) 50 Sqmm 3.5 Core
(ii) 16 Sqmm 4 core
(iii) 35 Sqmm 3.5 core
Supply, Laying & testing cable XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cables (Heavy duty) with aluminum conductor, 11000 Volts grade cross sectinal area 70 Sqmm 3 core complete all as specified and directed.
Supply, installation, testing and commissioning out door type, step down transformer, 11000/433 Volts (at no load) AC 3 phase, 50 Hz, 25 KVA capacity double copper wound, oil immersed naturally cooled with external cooling tubes, core type, delta connected on primary side (HV) and star connected on secondary side (LV side) in accordance with vector symbol DY-11(Vector group-4 with neutral brought on secondary and having tapping at (+/-)2.5%, (+/-)5%, (+/-)7.5% to be changed by means of manually operated "OFF LOAD" tap changing gear. The maximum temprature rise should not exceed 45 degrees celcius in oil and 50 degrees celcius in HV/LV winding when measured by resistance method after continuous full load run on ambient temp of 40 degree celcius. The transformer shall be IS-2026 marked of make : BHEL/ECE/Rajasthan transformors and switch gears Ltd/ITE Gurgaon and complete with the following standard fittings:-
(a) 03 Nos porcelain HV bushings with arcing horns on HV side suitable for 11 KV complete with bushing rods, nuts and washers etc. (b) One cable box on LV side (Secondary side) consisting of four Nos porcelain bushing with copper rods complete with nuts and washers with one No cable gland suitable for reception/taking out of 50 Sqmm 1100 Volts grade XLPE insulated heavy duty armoured cable in each gland including gland joint. (c) Oil conservator with filter type drain valve and oil level guage. (d) Dehydrating breather with first fill dehydrating agent (silica gel). (e) Explosive vent. (f) Thermometer pocket on tank cover.
(g) One No 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celcius with metal guard having maximum temp indicator with existing device for transformer. (h) Two earthing terminals on tank cover to faciliate fixing of flat iron 32x6mm galvanized iron earth strip for earthing on neutral and body. (j) Rating plate and terminal marking plate. (k) Oil level guage (l) Oil drain filter valve. (m) Lifting lugs (n) Oil filling hole with cap/plug with connection plate complete (o) Air release valve plug (p) Four plain solid cast steel detachable rollers. (q) First filling of new and unused transformer oil IS-335/93 (Fourth revision) marked filtered and tested upto 60 KV dielectric strength at 2.5 mm air gap between testing elctrode.
Supply, installation commissioning and testing HT 11 KV out door type gang operated air break switch outdoor type triple pole suitable for vertical mounting complete with MS channel of size 100 x 50 mm with suitable clamps MS bolts, nuts washers with operating mechanism worked from ground level current rating 200 amps complete with locking arrangement fuse unit type carriers and fuse element of required capacity and switch having 11 KV 3 phase including connecting with OH & HT UG cable all as specified and directed.
S&F lightening arrester HT non liner resister type coforming to IS-3070 pt I of 1985 suitable for HT 11 KV of nominal discharge capacity 65 killo amps including fixing on pole using FI clamps 50x6mm, nut bolts complete all as specified and directed.
Earthing with galvanised steel earth plate 600 x 600 x 6 mm thick buried directly in the ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5 m below ground level connected to galvanised iron earth GI strip 32 x 6 mm by means of bolts, nuts, checknut and washers of galvanised iron or steel, GI pipe 50 mm dia light grade for protection of earthing strip, PCC 1:4:8 type D-2 chamber using 40 mm graded stone aggregate, 0.63 mm PGI sheet funnel with GI wire mesh, 50 mm thick RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) cover reinforced with 8 mm dia for steel round bars, charcoal dust and common salt all as per electric plate No 3 of SSR part I including excavation and earth work and connection with earth lead for equipment, complete all as specified and directed.
Special earthing transformer body and sub station equipment with galvanised MS plate of size 600 x 600 x 6 mm thick buried vertically in ground to a depth not less than 4.5 m below ground level, with top edge of the plate not less than 3.75m below ground level, the earth plate surrounded by adequate quantities of char coal dust and salt to a packed thickness of 15Cm on all sides, excavation, earth work, returning filling, removal of surplus soil to a distance 50m PCC 1:2:4 type B-1 as in earth chamber 50mm thick RCC cover using cement concrete 1:2:4 tpe B-0 reinforced with and including 6mm dia mild steel round bars @ 100 mm center to center both way with suitable handles for lifting arrangement including GI strip of size 32x6 mm soldered and riveted to earth plate at one end connected to metallic body of HT/LT equipment / transformer body and neutral at the other end GI earth strip shall be encased in and including 50mm nominal bore GI light grade pipe with all fittings form earth plate upto transformer on pole/KIOSK complete all as shown on electrical plate No 3 of SSR Part-I and all as specified & directed.
Supplying fixing, connecting and testing of single piece die cast aluminium housing street light fitting complete with and including 150 W HPSV lamp, 40 mm light grade nominal bore GI pipe brackets made out of medium grade pipe of required length not less than 1.2 m mounting brackets made out of mild steel F1 40X6 mm of required shape ( two Nos) duly fitted on pole with Mild steel nuts bolts and washer and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer PVC insulated 2.50 Sqmm (3 single core) cable, copper conductor multi stranded, weather proof of required length sheet metal enclosure to light fitting and connecting and lamp complete all as specified. Make:- Philips type SRP 308/70(E) or equivalent in Bajaj, Crompton
S&F sheet metal enclosure box for outdoor use, IP-54 made out of MS sheet not less than 02mm factory fabricated front openable duly painted of size 300 X 250 X 100 mm deep having aluminium Bus bar of size 25x3mm ,3 phase and neutral including MCB SP 6 Amps, gunmetal cable gland for 16 sqmm 4 core LT cable fixed to pole with MS 25X6 mm GI clamps made to shape with required nut bolt washers etc. for street light fittings complete all as specified and directed.
Supply and fix cable end jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for3 core XLPE armoured Al conductor cable of size 50 to 95 sq mm complete all as specified and directed.
Supply and erection of 16 meter high mast lighting system raising and lowering type complete comprising the following :- Make Bajaj/ Crompton/Philips as approved by GE.
(a) Mast shaft shall be in two sections hot dip galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 part III . There shall be only one longitudinal seam weld per section and no circumferential well it shall also include accessories for high mast including head frame. 2 point suspension system with stainless steel wire rope 6 mm dia construction double drum winch galvanized lantern carriage arrangement suitable for 8 luminaries symmetrically and its CG boxes and lighting final, the mast shall have integral type power tool at the base compartment for it operation complete all as specified and directed..
(b) Costn of suitable shallow RCC foundation with M-20 grade crushed stone concrete including foundation bolts nuts washers anchor plate and items plates made form special steel including excavation and earth work as per manufacturer instructions/ design complete all as specified and directed..
(c) Supply and fix connecting complete LED type twin dome aviation obstruction light complete all as specified and directed.. Make : Bajaj complete
(d) S&F and connection and testing of integral flood light luminaries type BGENF 22 with 02 Nos 400 W MH lamps and control gear boxes with suitable size of wiring of luminaries with all wiring inclu-ding fixing on high mast light complete all as specified and directed.
Note :- All type test and routine test certificate shall be dispatched directly from manufacturer to consignee and GE (P) Dehradun.
Supply, fabricating, installation, testing and commissioning LT panel 440 Volts AC, 3 phase 4 wire ,50 cycle for outdoor use feeder pillar box, made out of 3.15 mm thick CRCA sheet totally enclosed weather proof and vermin proof suitable size complete wiring alumnium bus bar chamber cable alley, cable glandes brass cromimum plated of different sizes suitable for incoming and out going cables, painted with powder coated paint and including required PCC work and all specified for the following items:-
BLANK
Som Prakash Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .