Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC TC 25664 RAJI OPP HOTEL AMRITHA THYCAUD THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | ₹1.5 L | L1 | Accepted-AOC Agreement executed |
| 2 | L2₹1.6 LRejected-Finance | ₹1.6 L | L2 | Rejected-Finance Higher rate, hence rejected |
Tender Value
Refer Docs
EMD Value
₹3,813
Closing Date
25 May 2026, 6:30 pmClosed
Assistant Executive Engineer
PWD ELECTRICAL SUB DIVISION,KLC, TVPM
GENERAL-Setting up new Conference Hall for Architecture Wing at Public Office Main Building, Thiruvananthapuram -Electrification Electrical AC Work
2026_PWD_851733_1
PWD/BLDG/TR/21304/2025
Open Tender
Electrical Works
90 days
Thiruvanathapuram
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
₹3,813
23 Jun 2026
19 May 2026
26 May 2026
19 May 2026
25 May 2026
19 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1New AC unit | ||||||
| 1.001 | OD352866/2025-2026:Supply , Installation, Testing and Commissioning of 1.5TR, of minimum ISEER 5 Air Cooled Hi Wall Invertor split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), Copper evoporator coil and condensing coil , surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celcius. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature) with comprehensive maintenance contract up to the end of DLP period including periodical services, gas topping etc. complete. (Blue star/Daikin/Mitsubishi/O-General or equivalent. (including stand) | - | each | 57,685.9 | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | OD251300/2025-2026:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge | - | metre | 858.45 | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | 90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm | - | metre | 140.66 | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | OD251294/2025-2026:Supply and fixing of 25mm (10kg/sq.cm) PVC pipe along with all required accessories in surface/ recess including cutting the wall and making good the damages etc. as required. | - | metre | 71.46 | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | 90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid | - | metre | 1,143.05 | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | 90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap | - | each | 148.07 | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | OD267117/2025-2026:Charges for dismantling the existing damaged AC unit complete and conveying to section store without further damage. | - | each | 431.33 | - | BI01010001010000000000000515BI0100001120 |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1439152.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
epayment.pdf
Other Document • 0.38 MB
make.pdf
Other Document • 0.19 MB
viewsbd.pdf
Tender Documents • 4.78 MB
BOQ_1439152.xls
BOQ • 0.31 MB
agree.pdf
Other Document • 0.53 MB
form.pdf
Other Document • 0.37 MB
IP.pdf
Other Document • 0.19 MB
affi.pdf
Other Document • 0.46 MB
Download all tender documents and submit your bid