Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC 121004 | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹8.5 L−₹27,025.89 (3.09%)Rejected-Finance WELLAMUNDA | L2 | Rejected-Finance 10 percentage deduction As per govt order for labour contracting society. L1 ACCEPTED. | |
| 3 | L3₹8.9 L+₹11,767.69 (1.35%)Rejected-Finance MANANTHAVADY | WAYANAD | KERALA | 670644 | L3 | Rejected-Finance 10 percentage deduction As per govt order for labour contracting society. L1 ACCEPTED. |
Tender Value
₹10 L
EMD Value
₹25,000
Closing Date
23 Jun 2020, 5:00 pmClosed
ASSISTANT ENGINEER
ASSISTANT ENGINEER, LSGD SECTION, PADINJARATHARA- 673575
CMLRRP 2020 21 POOKKOTTUKUNNU KUTTANNARIKUNNU ROAD CULVERT IN PADINJARATHARA
2020_LSGD_364137_1
AE/LSGD/PGP/CMLRRP/5/2020-21
Open Tender
Civil Works - Others
Item Rate
90 days
PADINJARATHARA
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,380
Yes
online
₹25,000
28 Aug 2020
11 Jun 2020
27 Jun 2020
11 Jun 2020
23 Jun 2020
11 Jun 2020
Amount
CULVERT ch;-1450m
11.1.1.1 : Excavation for StructuresEarthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.I.Ordinary soil(i)Upto 3 m depth
od699135/2020_2021 : DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.
od699136/2020_2021 : Providing concrete for plain/reinforced concrete in open foundations (WITHOUT FORMWORK) complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (11.4.1.1 Modified)P.C.C grade M 10, Nominal mix 1:3:6
11.4.1.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203I.P.C.C grade M 10(i)Nominal mix 1:3:6
12.5.1.1 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 mI.P.C.C grade M 15(i)Nominal mix (1:2.5:5)
12.7 : Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
12.5.3 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 m III.R.C.C grade M 20
od738061/2020_2021 : Providing concrete for reinforced concrete in MIDDLE BELT for DR Retaining Walls complete as per drawing and direction of Engineer-in-Charge.R.C.C grade M 20, nominal mix 1:2:4 (11.4.4 Modified)
13.3 : Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202
13.1.2 : Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5R.C.C M 25
od727485/2020_2021 : Filling with Quarry Muck<br>Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
od699727/2020_2021 : DRY RUBBLE MASONRY _ Dry rubble without concrete leveling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labor charges etc. complete as per direction of Departmental officers at site.
od699734/2020_2021 : Construction of Plain Cement Concrete Pavement (WITH FORM WORK) : Mord Item 6.4 ModifiedConstruction of Plain Cement Concrete Pavement, thickness as per design,over a prepared sub base, with 43 grade cement or any other type as per clause 1501.2.2 (M 20 grade), coarse and fine aggregates conforming to IS 383 (maximum size of coarse aggregate not exceeding 25 mm) mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side form work (steel channel, wedges,steel plates including leveling the form work as per drawing), spreading the concrete with shovels, rakes, compacted using needle vibrators and finished in continuous operation including provision of contraction and expansion construction joints, curing of concrete slabs for 14 days, with water finishing to lines and grade as per drawing and Technical Specifications clause 1501
od701218/2020_2021 : Pumping or Bailing out water and removing slush etc by using Pump set including cost of labour, oil, hire charges of pump set etc complete
2.5.1.C : Dismantling of StructuresDismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.(I) By Manual Means(C) Reinforced Cement Concrete
2.5.2.A : Dismantling of Structures<br> Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.<br>(II) By Mechanical Means <br> (A) Cement Concrete
10.4.A.3 : Direction and Place Identification signs with size more than 0.9 sqm size board<br> A. Retro-reflectorised Traffic Signs <br>3 Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on RCC Posts 100 mm x 100 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
Kottathara Labour Contract Co-operative Society
Joseph VU
Bidder Name
Joseph VU
AC Nasar
Kottathara Labour Contract Co-operative Society
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_514291.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .