Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC NEW AZAD NAGAR IDGAH MOHALLA BISHUNPUR B POLYTECHNIC DHANBAD DHANBAD 828130 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828130 | ₹4.0 L | L1 | Accepted-AOC AOC ACCEPTED AS PER NIT |
| 2 | L2₹4.1 LRejected-Finance | ₹4.1 L | L2 | Rejected-Finance REJECTED |
| 3 | L3₹4.2 LRejected-Finance ANGARPATHA KATRASGARH DHANBAD | DHANBAD | DHANBAD | JHARKHAND | 828113 | ₹4.2 L | L3 | Rejected-Finance REJECTED |
Tender Value
₹3.8 L
EMD Value
₹4,800
Closing Date
27 Mar 2026, 6:00 pmClosed
AM (EnM), PB AREA
pba rea, putki
Rectification and maintenance of 6 No. Feeder 6.6 KV, Main Sub-Station and different LT O/H line (Sri Nagar, 2 No. Colony, 3 No. Colony, 10 No. Colony and 13 No. Colony) under Pootki colliery
2026_BCCL_356902_1
BCCL/PBA/AM(EnM)/2025-26/118 DATED-17.03.2026
Open Tender
Electrical and Maintenance Works
7 days
PUTKI COLLIERY
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,800
4 Apr 2026
17 Mar 2026
28 Mar 2026
17 Mar 2026
27 Mar 2026
17 Mar 2026
17 Mar 2026 - 20 Mar 2026
Item Description/ Heading
A) FOR 6 No. feeder 6.6 KV O/H line maintenance -Damage & weak jumper repairing with binding wire etc.
Dismantle of burnt cable joint from switch & jumper from O/H line 3 + 3 = 6 nos
Supply & making indoor cable end jointing including lugs and other jointing materials for 185/240 sq mm with Switch by compound and other materials (CPWD SOR' 2012, P-34, 10.1.3)
Opening jumper for searching faults & after megguring re-jumpering
Opening jumper for changing of faulty Disc insulator
Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (CPWD SOR' 2012, P-40, 12.40)
Supply & erection of 11 KV Disc insulator for O/H line with galvanised insulator fittings, bolts, nuts, washers etc. as required (CPWD SOR' 2012, P-42, 13.11)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Making new jumper with O/H line after changing faulty Disc
Dismantle of faulty AB Switch
Fabrication & erection of bracket & clamps
Supply and erection of M.S Nut & Bolts
Erection of AB Switch on pole
Taking down of one no. PVC insulated power cable of 11 KV grade of 185/240 sq mm for making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)
Laying/Hanging of one no. PVC insulated power cable of 185/240 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade (CPWD SOR' 2012, P-35, 10.5.3)
Tree & branches cutting below O/H line
B) FOR Sri Nagar LT O/H line maintenance - Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (CPWD SOR' 2012, P-40, 12.40)
Dismantle of pole/street light standard/strut embedded in cement concrete foundation etc. as required (CPWD SOR' 2012, P-40, 12.42)
Transportation of dismantle pole
Transportation of Pole at site
Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR' 2012, P-36, 11.3.3)
Erection of metallic pole of 12 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) (CPWD SOR' 2012, P-36, 11.3.4)
Fabrication & erection of bracket & clamps
Supply & erection of M.S Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR' 2012, P-39, 12.17)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Making new jumper with O/H line
Crane for erection of 12 mtr 3 nos pole in conjusted colony houses
Laying/Hanging of one no. PVC insulated power cable of 185 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 185 sq mm size of 3 core, XLPE Aluminium conductor cable of 11 KV grade (CPWD SOR' 2012, P-34, 10.2.3)
Supply & making indoor cable end jointing including lugs and other jointing materials for 185 sq mm with Switch by compound and other materials (CPWD SOR' 2012, P-34, 10.1.3)
Damage & weak jumper repairing with binding wire etc.
Tree & branches cutting below O/H line
C) FOR 2 No. LT O/H line maintenance - Dismantle of pole/street light standard/strut embedded in cement concrete foundation etc. as required (CPWD SOR' 2012, P-40, 12.42)
Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR' 2012, P-36, 11.3.3)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Tree & branches cutting below O/H line
D) FOR 3 No. LT O/H line maintenance - Dismantle of pole/street light standard/strut embedded in cement concrete foundation etc. as required (CPWD SOR' 2012, P-40, 12.42).
Transportation of pole at site
Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR' 2012, P-36, 11.3.3)
Fabrication & erection of bracket & clamps
Supply and erection of M.S Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR' 2012, P-39, 12.17)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Damage & weak jumper repairing with binding wire etc.
E) FOR 10 No. LT O/H line maintenance - Dismantle of cable jumper from O/H line
Taking down of one no. PVC insulated power cable of 1.1 KV grade of 70 sq mm for making fresh lead (CPWD SOR' 2012, P-27, 7.5.2)
Laying/Hanging of one no. PVC insulated power cable of 1.1 KV grade of 70 sq mm after making fresh lead (CPWD SOR' 2012, P-27, 7.5.2)
Making fresh new cable jumper with O/H line
Transportation of pole at site
Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR' 2012, P-36, 11.3.3)
Fabrication & erection of bracket & clamps
Supply and erection of M.S Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR' 2012, P-39, 12.17)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
F) FOR 13 No. LT O/H line maintenance - Dismantle of pole/street light standard/strut embedded in cement concrete foundation etc. as required (CPWD SOR' 2012, P-40, 12.42).
Transportation of pole at site
Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR' 2012, P-36, 11.3.3)
Fabrication & erection of bracket & clamps
Supply & erection of M.S Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR' 2012, P-39, 12.17)
Erection of Conductor of 7/2.11 mm to 7/3.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.21)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Making new jumper with O/H line
G) FOR main sub station O/H maintenance work - Making of Earthpit by G.I earthing pipe with charcoal & salt
Connection Transformer/Switch neutral & body with earthpit by cable lead
H) FOR Store Work - Crane for Transportation of 12 mtrs 3 nos poles from Regional Store to Colliery store with 6 heads i.e 6000 + 4404 = Total Rs. 10404.00
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.72 MB
BOQ_369781.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid