| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC NEW AZAD NAGAR IDGAH MOHALLA BISHUNPUR B POLYTECHNIC DHANBAD DHANBAD 828130 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828130 | ₹4.0 L | L1 | Accepted-AOC AOC ACCEPTED AS PER NIT |
| 2 | L2₹4.1 L+₹7,558.62 (1.89%)Rejected-Finance | ₹4.1 L+₹7,558.62 (1.89%) | L2 | Rejected-Finance REJECTED |
| 3 | L3₹4.2 L+₹22,675.86 (5.66%)Rejected-Finance ANGARPATHA KATRASGARH DHANBAD | DHANBAD | DHANBAD | JHARKHAND | 828113 | ₹4.2 L+₹22,675.86 (5.66%) | L3 | Rejected-Finance REJECTED |
Tender Value
₹3.8 L
EMD Value
₹4,800
Closing Date
27 Mar 2026, 6:00 pmClosed
AM (EnM), PB AREA
pba rea, putki
Rectification and maintenance of 6 No. Feeder 6.6 KV, Main Sub-Station and different LT O/H line (Sri Nagar, 2 No. Colony, 3 No. Colony, 10 No. Colony and 13 No. Colony) under Pootki colliery
2026_BCCL_356902_1
BCCL/PBA/AM(EnM)/2025-26/118 DATED-17.03.2026
Open Tender
Electrical and Maintenance Works
Percentage
7 days
PUTKI COLLIERY
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,800
4 Apr 2026
17 Mar 2026
28 Mar 2026
17 Mar 2026
27 Mar 2026
17 Mar 2026
17 Mar 2026 - 20 Mar 2026
Item Description/ Heading
A) FOR 6 No. feeder 6.6 KV O/H line maintenance -Damage & weak jumper repairing with binding wire etc.
Dismantle of burnt cable joint from switch & jumper from O/H line 3 + 3 = 6 nos
Supply & making indoor cable end jointing including lugs and other jointing materials for 185/240 sq mm with Switch by compound and other materials (CPWD SOR' 2012, P-34, 10.1.3)
Opening jumper for searching faults & after megguring re-jumpering
Opening jumper for changing of faulty Disc insulator
Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (CPWD SOR' 2012, P-40, 12.40)
Supply & erection of 11 KV Disc insulator for O/H line with galvanised insulator fittings, bolts, nuts, washers etc. as required (CPWD SOR' 2012, P-42, 13.11)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Making new jumper with O/H line after changing faulty Disc
Dismantle of faulty AB Switch
Fabrication & erection of bracket & clamps
Supply and erection of M.S Nut & Bolts
Erection of AB Switch on pole
Taking down of one no. PVC insulated power cable of 11 KV grade of 185/240 sq mm for making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)
Laying/Hanging of one no. PVC insulated power cable of 185/240 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade (CPWD SOR' 2012, P-35, 10.5.3)
Tree & branches cutting below O/H line
B) FOR Sri Nagar LT O/H line maintenance - Dismantling of over head lines comprising of Copper/Aluminium over head conductor, G.I wire, cross arms, insulators etc as required (CPWD SOR' 2012, P-40, 12.40)
Dismantle of pole/street light standard/strut embedded in cement concrete foundation etc. as required (CPWD SOR' 2012, P-40, 12.42)
Transportation of dismantle pole
Transportation of Pole at site
Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR' 2012, P-36, 11.3.3)
Erection of metallic pole of 12 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) (CPWD SOR' 2012, P-36, 11.3.4)
Fabrication & erection of bracket & clamps
Supply & erection of M.S Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR' 2012, P-39, 12.17)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Making new jumper with O/H line
Crane for erection of 12 mtr 3 nos pole in conjusted colony houses
Laying/Hanging of one no. PVC insulated power cable of 185 sq mm after making fresh lead (CPWD SOR' 2012, P-28, 8.3.2)
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 185 sq mm size of 3 core, XLPE Aluminium conductor cable of 11 KV grade (CPWD SOR' 2012, P-34, 10.2.3)
Supply & making indoor cable end jointing including lugs and other jointing materials for 185 sq mm with Switch by compound and other materials (CPWD SOR' 2012, P-34, 10.1.3)
Damage & weak jumper repairing with binding wire etc.
Tree & branches cutting below O/H line
C) FOR 2 No. LT O/H line maintenance - Dismantle of pole/street light standard/strut embedded in cement concrete foundation etc. as required (CPWD SOR' 2012, P-40, 12.42)
Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR' 2012, P-36, 11.3.3)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Tree & branches cutting below O/H line
D) FOR 3 No. LT O/H line maintenance - Dismantle of pole/street light standard/strut embedded in cement concrete foundation etc. as required (CPWD SOR' 2012, P-40, 12.42).
Transportation of pole at site
Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR' 2012, P-36, 11.3.3)
Fabrication & erection of bracket & clamps
Supply and erection of M.S Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR' 2012, P-39, 12.17)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Damage & weak jumper repairing with binding wire etc.
E) FOR 10 No. LT O/H line maintenance - Dismantle of cable jumper from O/H line
Taking down of one no. PVC insulated power cable of 1.1 KV grade of 70 sq mm for making fresh lead (CPWD SOR' 2012, P-27, 7.5.2)
Laying/Hanging of one no. PVC insulated power cable of 1.1 KV grade of 70 sq mm after making fresh lead (CPWD SOR' 2012, P-27, 7.5.2)
Making fresh new cable jumper with O/H line
Transportation of pole at site
Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR' 2012, P-36, 11.3.3)
Fabrication & erection of bracket & clamps
Supply and erection of M.S Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR' 2012, P-39, 12.17)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
F) FOR 13 No. LT O/H line maintenance - Dismantle of pole/street light standard/strut embedded in cement concrete foundation etc. as required (CPWD SOR' 2012, P-40, 12.42).
Transportation of pole at site
Erection of metallic pole of 8 to 10 metre length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required (CPWD SOR' 2012, P-36, 11.3.3)
Fabrication & erection of bracket & clamps
Supply & erection of M.S Nut & Bolts
Supplying and erection of 100 mm X 110 mm shackle insulators with G.I bolts, nuts, and straps etc. as required (CPWD SOR' 2012, P-39, 12.17)
Erection of Conductor of 7/2.11 mm to 7/3.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.21)
Erection of Conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc (CPWD SOR' 2012, P-39, 12.22)
Making new jumper with O/H line
G) FOR main sub station O/H maintenance work - Making of Earthpit by G.I earthing pipe with charcoal & salt
Connection Transformer/Switch neutral & body with earthpit by cable lead
H) FOR Store Work - Crane for Transportation of 12 mtrs 3 nos poles from Regional Store to Colliery store with 6 heads i.e 6000 + 4404 = Total Rs. 10404.00
Total impact of GST for the purpose of CTC
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 2.72 MB
BOQ_369781.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .