Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹38.9 L+₹62,055.20 (1.62%)Rejected-Finance SECTOR 10 PANCHKULA | PANCHKULA | PANCHKULA | HARYANA | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹40.6 L+₹2.4 L (6.18%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L3 | Rejected-Finance Other Than Lowest Bidder | |
| 4 | L4₹41.5 L+₹3.2 L (8.44%)Rejected-Finance CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L4 | Rejected-Finance Other Than Lowest Bidder | |
| 5 | L5₹41.7 L+₹3.4 L (8.98%)Rejected-Finance | L5 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
₹46.8 L
EMD Value
₹93,500
Closing Date
7 Oct 2023, 6:00 pmClosed
GE Chandigarh
GE Chandigarh N Area Pin-160003
SPECIAL REPAIR TO EXTERNAL ELECTRIFICATION TO CONVERT OVER HEAD LINE TO UNDER GROUND CABLES INCLUDING CERTAIN SANCTIONED REVENUE AND MINOR WORKS OF E/M NATURE AT K AREA UNDER GE CHANDIGARH
2023_MES_618077_1
GE/CHD-43/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chandigarh
Class D category b(i) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹93,500
Yes
1 Dec 2023
9 Sept 2023
9 Oct 2023
9 Sept 2023
7 Oct 2023
25 Sept 2023
9 Sept 2023 - 17 Sept 2023
Amount
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of size 400 Sqmm 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item no 1 above but size 240 Sqmm 3.5 core.
All as per item no 1 above but size 185 Sqmm 3.5 core.
All as per item no 1 above but size 120 Sqmm 3.5 core.
All as per item no 1 above but size 70 Sqmm 3.5 core.
All as per item no 1 above but size 50 Sqmm 3.5 core.
All as per item no 1 above but size 25 Sqmm 3.5 core.
All as per item no 1 above but size 25 Sqmm 2 core.
All as per item no 1 above but size 16 Sqmm 4 core.
All as per item no 1 above but size 16 Sqmm 2 core.
All as per item no 1 above but size 10 Sqmm 4 core.
All as per item no 1 above but of size 10 Sqmm 2 core.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm surrounded by mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less 2.25mtr below ground level with top edge of earth plate at a depth of not less than 1.50mtrs below ground level connected with and including 32x6mm galvanized iron strip as earthing lead by means of bolts, nuts, check nuts and washers made out of galvanized iron, 20mm dia medium grade GI pipes for watering with funnel, wire mesh and 40mm GI light grade protection pipe for GI strip and including necessary excavation, earth work, PCC 1:3:6 type C-2 concrete pit and RCC pit cover charcoal and common salt filling in alternate layers complete all as specified and directed by Engineer-in-Charge on electrical plate no-3 of SSR Par-I of 2009. Note:(i) If desirable earthing result not found re done earthing without any extra charge until get required earth resistance. (ii) The result sheet of earthing may submit to sub division level by contractor.
Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge. Note : (i)The unit rate includes for protecton pipe 15mm and GI earth strip 4mm from top of earth plate upto 7.50 metre above ground level. (ii) If desirable earthing result not found re done earthing without any extra charge until get required earth resistance. (iii) The result sheet of earthing may submit to sub division level by contractor.
M&L for cable route indicator made of cast iron plate circular type 10 cm dia duly marked Blue colour marked LT cabless arrows mark up side duly welded/nut, bolt with angle iron 45/45 equal size and 45 cm long duly grouted on fround with PCC (1:3:6) as in foundation & earth work excavation etc complete all as specified an directred at site.
Supply, install, testing & commissioning of distribution LT panel OUTDOOR of suitable size factory fabricated(Approved by CPRI) outdoor cubical/KIOSK type totally enclosed made out of 3.15 mm thick MS sheet and inner comparments of 2.00mm thick steel sheet enclosure with double door shutter with locking arrangement and angle iron legs made out of 50mmx50mmx 6 mm thick MS angle mounted on plateform suitable for operation on 3 phase,4 wire ,440volts, AC supply system with hinged panel door(covers) on two sides with handle,bottom gland plate and locking arrangement consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure ,required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with strandard copper conductor FRLS wires of adequate size,duly powder coated internally & externally of approved shade with PCC foundation mounted on epoxy insulators with :- 4 Nos of Aluminium bus bar with colour code of 1000 Amps capacity each and supply and fixing the following(Main LT Panel No-1) :- Incoming (a) MCCB 630 Amps , 4 pole, ultimate breaking capacity 35 KA 415 Volts – 01 Nos Outgoing (a) MCCB 400.00 Amps , 4 pole, breaking capacity 25 KA,415 Volts – 01 Nos (b) MCCB 315 Amps 4 Pole,25 KA, 415 V-02 Nos. (c) MCCB 250 Amps 4 Pole,25 KA, 415 V-01 Nos. (d) MCCB 100 Amps 4 Pole,25 KA, 415 V-01 Nos. (e) MCCB 63 Amps 4 Pole,25 KA, 415 V-01 Nos. (f) MCB TPN 63 Amps 2 Pole,240 V-01 Nos. (d) Suitable size of Timer analog type for street light with power contractor complete
Supply, install, testing & commissioning of distribution LT panel OUTDOOR of suitable size factory fabricated(Approved by CPRI) outdoor cubical/KIOSK type totally enclosed made out of 3.15 mm thick MS sheet and inner comparments of 2.00mm thick steel sheet enclosure with double door shutter with locking arrangement and angle iron legs made out of 50mmx50mmx 6 mm thick MS angle mounted on plateform suitable for operation on 3 phase,4 wire ,440volts, AC supply system with hinged panel door(covers) on two sides with handle,bottom gland plate and locking arrangement consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure ,required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with strandard copper conductor FRLS wires of adequate size,duly powder coated internally & externally of approved shade with PCC foundation mounted on epoxy insulators with 4 Nos of Aluminium bus bar with colour code of 475 Amps capacity each and supply and fixing the following(LT Panel No-2) :- Incoming (a) MCCB 315 Amps , 4 pole, ultimate breaking capacity 35 KA 415 Volts – 01 Nos Outgoing (a) MCB TPN 63 Amps , 4 pole, breaking capacity 25 KA,415 Volts – 05 Nos (b) MCB DP 63 Amps 2 Pole,25 KA, 240 V-12 Nos. (c) MCB DP 40 Amps 2 Pole,25 KA, 240 V-12 Nos. (d) Change over switch 315 Amps 415 V -01 Nos.
Supply, install, testing & commissioning of distribution LT panel OUTDOOR of suitable size factory fabricated(Approved by CPRI) outdoor cubical/KIOSK type totally enclosed made out of 3.15 mm thick MS sheet and inner comparments of 2.00mm thick steel sheet enclosure with double door shutter with locking arrangement and angle iron legs made out of 50mmx50mmx 6 mm thick MS angle mounted on plateform suitable for operation on 3 phase,4 wire ,440volts, AC supply system with hinged panel door(covers) on two sides with handle,bottom gland plate and locking arrangement consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure ,required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with strandard copper conductor FRLS wires of adequate size,duly powder coated internally & externally of approved shade with PCC foundation mounted on epoxy insulators with 4 Nos of Aluminium bus bar with colour code of 300 Amps capacity each and supply and fixing the following(LT Panel No-3) :- Incoming (a) MCCB 200 Amps , 4 pole, ultimate breaking capacity 35 KA 415 Volts – 01 Nos Outgoing (a) MCB TPN 63 Amps , 4 pole, breaking capacity 25 KA,415 Volts – 01 Nos (b) MCB DP 63 Amps 2 Pole,25 KA, 240 V-05 Nos. (c) MCB DP 40 Amps 2 Pole,25 KA, 240 V-05 Nos. (d) Change over switch 200 Amps 415 V -01 Nos.
Supply, install, testing & commissioning of distribution LT panel OUTDOOR of suitable size factory fabricated(Approved by CPRI) outdoor cubical/KIOSK type totally enclosed made out of 3.15 mm thick MS sheet and inner comparments of 2.00mm thick steel sheet enclosure with double door shutter with locking arrangement and angle iron legs made out of 50mmx50mmx 6 mm thick MS angle mounted on plateform suitable for operation on 3 phase,4 wire ,440volts, AC supply system with hinged panel door(covers) on two sides with handle,bottom gland plate and locking arrangement consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure ,required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with strandard copper conductor FRLS wires of adequate size,duly powder coated internally & externally of approved shade with PCC foundation mounted on epoxy insulators with 4 Nos of Aluminium bus bar with colour code of 200 Amps capacity each and supply and fixing the following(LT Panel No-4) :- Incoming (a) MCCB 100 Amps , 4 pole, ultimate breaking capacity 35 KA 415 Volts – 01 Nos Outgoing (a) MCB TPN 63 Amps , 4 pole, breaking capacity 25 KA,415 Volts – 01 Nos (b) MCB DP 40 Amps 2 Pole,25 KA, 240 V-08 Nos.
Supply, install, testing & commissioning of distribution LT panel OUTDOOR of suitable size factory fabricated(Approved by CPRI) outdoor cubical/KIOSK type totally enclosed made out of 3.15 mm thick MS sheet and inner comparments of 2.00mm thick steel sheet enclosure with double door shutter with locking arrangement and angle iron legs made out of 50mmx50mmx 6 mm thick MS angle mounted on plateform suitable for operation on 3 phase,4 wire ,440volts, AC supply system with hinged panel door(covers) on two sides with handle,bottom gland plate and locking arrangement consisting of sufficient no's of circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent water/moisture inside the enclosure ,required no's of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with strandard copper conductor FRLS wires of adequate size,duly powder coated internally & externally of approved shade with PCC foundation mounted on epoxy insulators with 4 Nos of Aluminum bus bar with colour code of 200 Amps capacity each and supply and fixing the following(LT Panel No-5) :- Incoming (a) MCCB 100 Amps , 4 pole, ultimate breaking capacity 35 KA 415 Volts – 01 Nos Outgoing (a) Timer with contractor 3 Phase 100 Amps,415 Volts – 02 Nos
Supply & install steel tubular pole swaged welded with MS base plate size 30cm x 30cm x 6mm thick final taper plug bolts nuts & washers as per IS: 2713 (part-I) 1980 made out of MS tubing including painting of two coats of aluminium paint of approved quality over one coat of red oxide primer length 9.00 mtr long 410 SP -31 using for any description of external electric work all as specified and directed by Engr-in-charge. NOTE : (i) Earth work and PCC work will be measured and paid separately under respective item of the schedule. (ii) Material and labour for ACSR conductor, cross arms, insulators will be measured and paid separately under respective item of the schedule.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S&F street light bracket made out of 40/32mm dia fancy type top mounted, 1.50 mtr long GI tubing, "medium grade" ISI marked, bent to required shape and angle as per site requirement with and including MS clamps size 30X6mm, with nuts, bolts, washers etc for fixing street light fittings and bracket, duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply only PVC insulated copper wire FRLS of size 2.5 Sqmm (nominal area) 3 core with 200 mm dia PVC conduit for street light wherever required at site and as directed by Engr -in-charge.
M&L for Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate in coping/padestal to poles including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 and applying two coats of white wash complete all as specified and directed.
S&F Plastic Rectangular sintex SMC/FRP Juction box for street light pole including MCB 10 Amp and terminal with M.S clamps, nuts, bolt and washer of approved size for LT pole for street light pole box
M&L for steel water tubing, galvanised, light grade, ISI marked, 100 mm bore fixed along poles, under roads/culverts complete all as specified and directed by Engineer-in-Charge.
All as per item no 28 above but 80 mm dia.
All as per item no 28 above but 50 mm dia.
All as per item no 28 above but 40 mm dia.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge.
All as per item no 32 above but exceeding 1.5 mtr depth and not exceeding 3 mtr depth complete all as specified and directed.
Returning, filling in (soils) including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil (Soils) not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I
Supply and laying burntbricks sub class "B" old size for cable protection laid flat lengthsise perpenducualr to the axis of cable complete all as specified and direted by Engineer-in-Charge.
Supply and fix MCB DB sheet metal encolsure Triple pole and Neutral 4 way double door 415 Volts.
Supply and fix MCB TPN/FP, 'B' series. 10 KA, 415 Volts 40 to 100 Amps capacity.
Supply and fix MCB SP, 'C' series. 10 KA, 240 Volts, 6-32 Amps capacity.
M & L for trenches less cutting of road and culvert at the span of upto 6 mtr for crossing of UG cable and GI pipe of size up 50/40 mm dia
Supply and fixing on LT pole danger notice plate for LT of size 20 cm x 15 cm , 1.6mm thick mild steel sheet vitreous enameled white with letters, figure and conventional skull & bones “DANGER” etc. in signal red colour and fixed with MS clamps made out of 25mmx3mm MS flat iron, nut, bolts complete all as specified and directed.
Material, fabrication and labour for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections inclidng nuts, bolts, washers , welding, bending cold or hot, driling holes for bolts, in and shape or size as indicated or directed and inclusive of one primer coat and two under coat of synthetic enamel paint and incl removing rusted cross arm complete all as specified.
M&L for stay assembly for LT poles comprising of 20mm dia, 2.15 mtr long galvanized stay rod , having 7 / 2.25 mm GI stay wire stranded and 300mm X 500mm X 6mm thick MS stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/accessories like loop type insulator overall dimensions 90mmx140mm, clearance of hole 25.5mm, shackle & stay clamps made out of 50x6mm MS flat iron, necessary excavation and earth work in soft/loose soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge.
Taking down of LT XLPE/ PVC UG cable 1100 V grade, 2 core/4 core of size upto 25 Sqmm from the trenches complete all as directed by Engineer - in charge . Note1 : - Excavation,RFR,Sand, Brick, will be measured and paid seperately under the respective items.
Taking out old unsv RCC Poles 9 mtr long all as specified and directed by Engineer-in-Charge.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m.
Dismantling insulators any type, any size complete all as specified and directed by Engineer-in-Charge.
Dismantling of ACSR or AAC conductors complete all as specified and directed by Engineer-in-Charge.
Dismantling earth wire , service feeder or distributor span complete all as specified and directed by Engineer-in-Charge.
Dismantling stay assembly complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking down carefully any type of pole complete all as spcified and directed.
M/s Friends Engineering Works
GS Engineers
Jai Maa Electrical Works
bharat contrectors
unique power & control system
Alpha Engineers and Builders
Bharat Enterprises
M/s Shiksha Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .