Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC | ₹14.3 L | L1 | Accepted-AOC Due to L1 |
| 2 | L2₹14.8 L+₹44,052 (3.07%)Rejected-Finance | ₹14.8 L+₹44,052 (3.07%) | L2 | Rejected-Finance Due to L2 |
| 3 | L3₹14.9 L+₹57,202 (3.99%)Rejected-Finance H NO 19 6 243 1 NGO S COLONY SHIV NAGAR NORTH BIDAR 585401 | BIDAR | KARNATAKA | 585401 | ₹14.9 L+₹57,202 (3.99%) | L3 | Rejected-Finance Due to L3 |
| 4 | L4₹15.6 L+₹1.3 L (8.85%)Rejected-Finance | ₹15.6 L+₹1.3 L (8.85%) | L4 | Rejected-Finance Due to L4 |
| 5 | L5₹15.9 L+₹1.6 L (10.9%)Rejected-Finance NO 3 26 DHUMANSOOR BIDAR DHUMANSUR KARNATAKA 585353 | BIDAR | KARNATAKA | 585353 | ₹15.9 L+₹1.6 L (10.9%) | L5 | Rejected-Finance Due to L5 |
Tender Value
₹15.3 L
EMD Value
₹30,500
Closing Date
20 Jul 2024, 6:00 pmClosed
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
PROVISION OF SOUND ABSORPTION FALSE CEILING AND WALLPANELLING IN ATC TOWER AT AFS BIDAR
2024_MES_661422_1
8107/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Bidar
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Bidar
₹30,500
Yes
25 Nov 2024
22 Jun 2024
22 Jul 2024
22 Jun 2024
20 Jul 2024
6 Jul 2024
Amount
Dismantling of wall and ceiling boards with frame work (fibre, pulp, insulation, etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
Providing and fixing Heradesign Superfine, 1 layer magnesite bonded (Not Cement bonded) wood wool acoustic panel, 1mm thick fibre, exquisite surface structure, size 1200 x 600 x 25mm, having edge detail AK-01 (5mm bevel on all 4 sides), weight 11.30Kg/Sqm, fire protection class B-s1,d0 as per EN 13501-1 & Humidity Resistance of 95%. Thickness Tolerance T2 (±1 mm/± 2 mm for 600/1200mm lengths respectively) according to EN 13168. Wood wool panels to be PEFC certified and should bear the Forest Stewardship Council Seal confirming that the wood used originates from responsibly managed forests. UD profile 28mm/27mm/0.60mm is fixed to the wall, such that the base of the UD profile is 25mm above the planned finished ceiling level / 25mm less that the finished wall level. The ends of the CD profile is to be inserted into the UD profile and placed at a distance of 600mm centre to centre and is to be secured to the wall using the AMF Heradesign Universal Bracket. The Universal brackets are to be fixed to the wall at a distance of 900mm using wall screws (for walls). Heradesign wood wool boards to be screw fixed to the CD profile using 6 screws (per board) 50/4. 50mm dia Heradesign screws. The wood wool board should be backed by 50mm thick glass wool slabs packed in 1200 x 600mm polythene bags having a gross density of 50kg/m3. The finished face of wood wool panels have to be installed at a distance of 85mm from the soffit to achieve a NRC of 0.90 as per ASTM C423. Panels can be spray painted on site (before installation) under supervision of manufacturer. Note: Tile & Grid to be painted as approved Make : Armstrong (Knauf Ceiling Solutions) or Equivalent as approved by GE.
Providing and fixing Heradesign Superfine, 1 layer magnesite bonded wood wool acoustic panel, 1mm thick fibre, exquisite surface structure, size 600 x 600 x 15, having edge detail SK-04, weight 7.80Kg/Sqm, fire protection class B-s1,d0 as per EN 13501-1 & Humidity Resistance of 95%. Thickness Tolerance T2 (± 1 mm) according to EN 13168. Wood wool panels to be PEFC certified & should bear the Forest Stewardship Council Seal confirming that the wood used originates from responsibly managed forests. The wood wool panels to be laid in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanized @ 50-60 gsm/sqm) consisting of Main "Tee", size 24W x 38H x 3600L mm made from 0.30 mm thick sheet spaced at 600mm centre to centre and Cross "Tee", size 24W x 28H x 600L mm made of 0.30 mm thick sheet to be interlocked between the main T runners at the distance of 600mm centre to centre to create 600x600mm module to lay ceiling tiles of approved surface pattern in the grid including, wherever required, cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. The perimeter trims to be of 22W x 19H x 3000L mm and 0.50 mm thick. Main "Tees" to be suspended from ceiling using 6mm dia and 50mm long anchor fasteners, SoH suspension hangers consisting of 4mm GI adjustable rods with galvanized level clips spaced at 900mm centre to centre along the Main Tee. The 4.00mm GI rods should be in accordance to IS 280:2006 and should have a zinc coating of not less than 90 gsm in accordance with IS 4826:1986 and a tensile strength of 300-550 MPa in accordance to IS 1608:2005. The first suspension from the perimeter trim should not exceed 300mm. The bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint. The wood wool board should be backed by 40mm thick rock wool slabs packed in 600 x 600 polythene bags having a gross density of 50kg/m3. The finished face of wood wool panels have to be installed at a distance of 300mm from the soffit to achieve a NRC of 0.90 as per ASTM C423. Panels can be spray painted on site under supervision of manufacturer. Note: Tile & Grid to be painted as approved . Make : Armstrong (Knauf Ceiling Solutions) or Equivalent as approved by GE.
Taking down carefully existing copper/aluminium point wiring (light/fan/sockets/bell/power point) complete with all accessories such as switch with sheet, ceiling rose including rusted/broken concealed conduit, junction and sunken boxes etc and removing dismantled material and making good disturbed surface of walls/floors etc matching with existing surface complete all as specified and as directed.
Concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 2mm thick galvanised steel pressed sunken box suitable for modular switch socket concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.
All as per item No. 5.00 here-in-before but in same board with other switches for 5 Amp switch socket with earth wire 1.5 sq mm FRLSH PVC insulated multistranded copper conductor FRLSH cable complete all as specified and as directed.
All as per item No. 5.00 here-in-before but for 5 Amp switch socket on independent board complete all as specified and as directed.
All as per item No 5.00 here-in-before but size of FRLSH cable 2.5 sqmm for 15 Amp switch socket with earth wire 2.5 sqmm FRLS PVC insulated multistranded copper conductor cable complete all as specified and as directed.
All as per item No 5.00 here-in-before but size of FRLSH cable 4.0 sqmm for 15 Amp switch socket with earth wire 4.0 sqmm FRLS PVC insulated multistranded copper conductor cable complete all as specified and as directed.
Concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing PVC conduit but including 2mm thick galvanised steel pressed sunken box suitable modular switch socket concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. complete all as specified and as directed. (switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ). Note:- Where ever it is not feasible to cable drawn through existing PVC conduit (for ceiling fan point only) due to blocked, casing caping shall be provided by contractor without any extra cost, cost for the same shall deemed to be included in the quoted unit rate.
Modular switch 1 way 6 Amps 1 module complete all as specified and as directed.
Modular switch 1 way 16 Amps 1 module complete all as specified and as directed.
Modular socket outlet 6 Amps 2/3 pin combined 2 module complete all as specified and as directed.
Modular socket outlet 6/16 Amps 2/3 pin combined 2 module complete all as specified and as directed.
Lamp holder, insulated body,with back plate for batten fitting including LED lamp 12 watt -01 No complete all as specified and as directed.
Ceiling rose three terminals 5 amps PVC / Polycarbonate, insulated body complete all as specified and as directed.
Point wiring with Television co-axial cable in and including concealed PVC conduit (25 mm dia) and conduit accessories and metal flush box of one module with cover fixed with screw and cap washers for Television point and making good all disturbed work to match the existing complete all as specified and directed
Modular type TV socket complete all as specified and as directed.
Sub main wiring with 2 runs of 6 sqmm, single core, FRLS PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through existing PVC conduit on surfaces of wall / floor with one run of FRLS PVC insulated 6 sqmm copper conductor for earth continuity including taking down existing submain wiring complete all as specified and as directed. Note :- 03 runs of 6 sqmm will be measured as one length.
Sub main wiring with 2 runs of 4 sqmm, single core, FRLS PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surfaces of wall / floor with one run of FRLS PVC insulated 4 sqmm copper conductor for earth continuity including taking down existing submain wiring complete all as specified and as directed. Note :- 03 run of 4 sqmm including 01 run of PVC conduit will be measured as one length.
Cutting chases, pinning in brick / PCC block masonry / concrete surfaces walls, making good to facings where required and pointing in cement mortar 1:3 to ends or edges for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth complete all as specified and as directed.
LED tube light fitting of LED T5 tube lights (6500K) environmental friendly energy efficient of 20 Watt LED 230 Volt, AC decorative box type with driver,holder including LED tube light electric connection with PVC copper flexible twin core cable, 1.0 sqmm from ceiling rose to light fitting including taking down old fitting complete all as specified and as directed.
LED street light luminarie 35 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting including taking down old fitting complete all as specified and as directed.
LED light fitting mirror type with high out put diffuser 2 feet , 10 Watt 220 V AC decorative type with driver holder including connecting up with three core flexible copper conductor cable of suitable size complete.
S & F MCB DB, SPN 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F MCB DB, TPN 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F Protector and accessories for AC starter 25 A, 2 Module grouted flush to walls complete all as specified and as directed.
S & F MCB, single pole, 240 Volts, 6-32 amps current rating and 10 KA breaking capacity, B' series type complete all as specified and as directed.
S & F MCB, Isolator TPN 4 pole, 415 Volts, of 63 amps current rating and 16 KA breaking capacity, B' series type complete all as specified and as directed.
S & F Isolator, Double pole, 240 Volts, of 32 amps current rating complete all as specified and as directed.
Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed ( GI wire upto 7.5m including testing consider in this item).
Refixing light fittings/fans inlcuding with fixtures like switch,sockets, MCB'S,DB's etc of any type and capacity duly remove by taking safety measures to serviceable one including with fixing accessories complete all as specified and directed.
Taking down carefully of AC's of any capacity and type with all safety measures free from leakings/damage and refixing the same inlcuding provn of new fixing accessories such as indoor frame, wire,extention copper pipe and filling reqd gas making to serviceable complete all as specified and directed.
Satish Patpally (BID ID -3068713)
RAMESH CONSTRUCTION COMPANY (BID ID -3068143)
kb technologies (BID ID -3068608)
NAYANA CONSTRUCTIONS (BID ID -3068692)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .