Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC | L1 | Accepted-AOC Bidders rates found lowest one among all participants | |
| 2 | L2₹14.7 L+₹1.2 L (9.24%)Rejected-Finance | L2 | Rejected-Finance rate quoted by firm found L2 | |
| 3 | L3₹14.8 L+₹1.4 L (10.1%)Rejected-Finance | L3 | Rejected-Finance rate quoted by firm found L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Dacuments not according to tender condition | |
| 5 | Rejected-Technical | - | Rejected-Technical Documents not according to tender conditions |
Tender Value
₹15.0 L
EMD Value
₹29,974
Closing Date
23 Jun 2020, 4:00 pmClosed
COMMANDANT ENGINEER SHQ BAREILLY
OFFICE OF THE COMMANDANT ENGR, SHQ BRLY, ITBP, BUKHARA CAMP BAREILLY, UP
AS ABOVE
2020_ITBP_563358_1
ITBP/SHQ(BLY)/ENG/14SSL3611
Open Tender
Civil Works - Others
Item Rate
730 days
FWD POST OF 14TH BN PITHORAGARH
AS PER TENDER DOC
12 documents required · 12 mandatory
₹0
₹29,974
Yes
23 Sept 2020
6 Jun 2020
24 Jun 2020
6 Jun 2020
23 Jun 2020
6 Jun 2020
6 Jun 2020 - 23 Jun 2020
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not wxceeding 1.5 m in depth or 10 sqm on plan), oncluding dressing of sides and remaining of bottoms, lift upto 1.5 m, including getting out and disposal of excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. Ordinary rock.For Bugdiyar Post
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not wxceeding 1.5 m in depth or 10 sqm on plan), oncluding dressing of sides and remaining of bottoms, lift upto 1.5 m, including getting out and disposal of excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. Ordinary rock.For Relikot Post
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not wxceeding 1.5 m in depth or 10 sqm on plan), oncluding dressing of sides and remaining of bottoms, lift upto 1.5 m, including getting out and disposal of excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. Ordinary rock.For Milam Post
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not wxceeding 1.5 m in depth or 10 sqm on plan), oncluding dressing of sides and remaining of bottoms, lift upto 1.5 m, including getting out and disposal of excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. Ordinary rock.For Dung Post
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 40 mm nominal size) For Bugdiyar Post
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 40 mm nominal size)For Relikot Post
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 40 mm nominal size)For Milam Post
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 40 mm nominal size)For Dung Post
Installation of 12 watt solar street light with Lithium ferro photosphate battery. Operates from dusk to dawn (First four hours at full brightness & amp rest of the time at lower level ) Battery capacity 40 AH, 5 mtr (16 ft) pole hight, Pre galvanised, MS with Hot Dip Galvanizing, MS with power coating material to be used for Pole, dia of pole should be 101.60 OD and thicness of pole 4mm as per MINRE specification under head BADP at verious Post of 14th BN ITBP Jajrdewal Pithoragarh (UKD).For Bugdiyar Post
Installation of 12 watt solar street light with Lithium ferro photosphate battery. Operates from dusk to dawn (First four hours at full brightness & amp rest of the time at lower level ) Battery capacity 40 AH, 5 mtr (16 ft) pole hight, Pre galvanised, MS with Hot Dip Galvanizing, MS with power coating material to be used for Pole, dia of pole should be 101.60 OD and thicness of pole 4mm as per MINRE specification under head BADP at verious Post of 14th BN ITBP Jajrdewal Pithoragarh (UKD).For Relikot Post
Installation of 12 watt solar street light with Lithium ferro photosphate battery. Operates from dusk to dawn (First four hours at full brightness & amp rest of the time at lower level ) Battery capacity 40 AH, 5 mtr (16 ft) pole hight, Pre galvanised, MS with Hot Dip Galvanizing, MS with power coating material to be used for Pole, dia of pole should be 101.60 OD and thicness of pole 4mm as per MINRE specification under head BADP at verious Post of 14th BN ITBP Jajrdewal Pithoragarh (UKD).For Milam Post
DALEEP SINGH
MAHAVEER CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .