Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.6 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹74.6 L+₹7.9 L (11.9%)Rejected-Finance CHEETHICODE P O KANJIRAMATTOM VIA ERNAKULAM 682315 | ERNAKULAM | KERALA | 682315 | L2 | Rejected-Finance L2 | |
| 3 | L3₹83.3 L+₹16.7 L (25.0%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹66.7 L
EMD Value
₹50,000
Closing Date
26 Apr 2022, 2:00 pmClosed
Deputy Manager (PED)
STEEL INDUSTRIALS KERALA LTD. ATHANI P.O THRISSUR- 680 581
Construction of TSCCC Control Room (Partial Components) at AR Camp, Nandavanam for Smart City, Thiruvananthapuram Ltd.-Electrical Works.
2022_SILK_485254_2
SILK/PED/S-3723/2021-22/805
Open Tender
Miscellaneous Works
Item Rate
90 days
Thiruvananthapuram
As per tender documents
6 documents required · 6 mandatory
₹2,950
₹50,000
Yes
7 May 2022
19 Apr 2022
27 Apr 2022
19 Apr 2022
26 Apr 2022
19 Apr 2022
19 Apr 2022 - 26 Apr 2022
Amount
TSCC ELECTRICAL
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.9 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.14.10 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire
1.18.2 : Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.19 : Supplying and fixing 20 amps 415volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps "C" curve, TPMCB, in sheet enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.20 : Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2.22 : Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
2.25 : Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for tripple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.
5.5 : Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
90.11.1.11 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
90.11.1.15 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
90.11.1.20 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
90.12.1.32 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).
90.12.1.36 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).
90.12.7.28 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.7.32 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.7.33 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.7.36 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.7.39 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.41.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.41.32 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.41.36 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.12.41.38 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
90.14.10.11 : Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.25 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm)
9.1.26 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
od347427/2021_2022 : Supplying and making end termination with brass<br>compression gland and copper lugs for following size of<br>PVC insulated and PVC sheathed / XLPE copper<br>conductor cable of 1.1 kV grade as required. 4 X 35 sq.<br>mm
od347428/2021_2022 : Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed I XLPE copper conductor cable of 1.1 kV grade as required. 4 X 70 sq. mm
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required
90.16.3.9 : Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)
90.16.4.8 : Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.
5.8 : Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
4.6.10 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.450 mm width X 62.5 mm depth X 2.0 mm thicknessICDDescriptionUnit
4.6.11 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.600 mm width X 62.5 mm depth X 2.0 mm thickness
4.7.10 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 62.5 mm depth X 2.0 mm thickness
4.7.11 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends " ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.600 mm width X 62.5 mm depth X 2.0 mm thickness
4.8.10 : Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" ( galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.450 mm width X 62.5 mm depth X 2.0 mm thickness
1.30 : Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
od347429/2021_2022 : supply, installation, testing and commissioning of 200 kVA(160kW), Diesel Generating Set with CPCBII approved acoustic enclosure comprising of Radiator Cooled Diesel engine having 1500 RPM, complete with standard accessories. Coupled to “Stamford” Alternator rated at 160KW/200 KVA at 415 Volts mounted on Channel Iron Base Frame complete with Fuel Tank,Control Panel and Batteries with battery charger. The control panel must be compatible with BMS system.
od347430/2021_2022 : supply, installation, testing and commissioning of 12kV, SF6 Ring Main Unit complete with Extensible, Outdoor type ( 2 Isolator +1 Breaker ) FBXE /12-20/ CCT2 /Outdoor – Motorised + Battery Charger, with IP 54 outer enclosure. Rated short time withstand current -21 kA for 3 seconds, 630A continues, rated current, Normal ambient temperature -25 °C to + 40 °C, IP 67 Rated lightning withstand voltage of 75 kA, SF6 tank of IP 67 ratting, Cable box for termination of cable up to 1 No. x 300 sq. mm. Snap action mechanism for manual operation with integrated earthing switch. ON, OFF, EARTH indication on the front mimic of the panel. Must have Emergency Trip Push Button.
od347431/2021_2022 : Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length , having a diameter of 20mm with copper bonding thickness of250 microns with self-coupling peg & bore arrangement with fault current withstand capability of 30 KA rms value for 1 second and I peak of 76 KA. Exothermic welded Clamp for clamping as suggested as per NBC 2016. Impact point on the bottom rod for easy insertion.Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 m. It should be free from hazardous substances. The mineral compound is required to have minimum 30 Kg of the total composite. The compound should be
od347432/2021_2022 : Supply and fixing Fully Solid Vertical Air terminals as per IS/IEC -62305 part-3,16mm rod tapered to 10 mm aluminium rod meter rod Meets the requirement (IS/IEC 62305) Semi-hard (E-AlMgSiO5) Suitable for high wind load. All air terminal must have Interception Tip at the Top of air terminal. System consist of Fang Fix with base and clamp on the top air terminal is erected. Air terminal Joining Clip Stainless Steel SS 304 clamp made of cable bracket, lightning tested for 100 KA 10/350 micro sec waveform.Stainless Steel Wall Clamp/16 KG stone of 365 mm diameter, high level of stability. No of stones/wall clamps depending on wind load. Quick and easy mounting of interception rod using anchors. Concrete, frostresistant, can be stacked. Govt approved Indian labs test certificate required. 2 meter air terminal with necessary mounting accessories Make: Cape/OBO/Erico
od347433/2021_2022 : Providing and laying copper coated steel solid round conductor 10mm diameter from earth electrode directly in ground as required. copper coated steel, high corrosion resistant (if pure copper conductor 25x3mm solid tape can also be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns tape can also be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. After test link needs to be routed inside Heavy duty conduit to avoid touch potential till ground level. Govt approved Indian labs test certificate required.
od347434/2021_2022 : Supply & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Down Conductor Holder made of weather resistant plastic @ every 0.8 meters
od347435/2021_2022 : Providing and fixing of Stainless Steel Test Joint suitable with suitable Outdoor Enclosure: For 8mm dia solid round aluminium conductor & 10mm dia copper coated solid steel round conductor having 100 microns of copper bonding (if pure copper conductor 25x3 mm solid tape also can be used). Conforms to the requirements according to (IS/IEC 62305).The enclosure should be outdoor glass-fibre reinforced polycarbonate opaque having minimum inner dimension of 75mm x 75 mm x 50 mm. The test link has to be straight and needs minimum 4 mounting screws for strong joints. Inspection of bimetallic corrosion at site required. Single bolt joints are not permitted. Govt approved Indian labs test certificate required
od347436/2021_2022 : Supply & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Parapet Holder made of weather resistant plastic @ every 0.4 meters
od347437/2021_2022 : Supply & fixing of 8mm solid aluminium round conductor with necessary holders @ required interval as specified below: Meets the requirement of (IS/IEC 62305) : semi-hard (E-AlMgSiO5 )with 50 sq.mm cross sectional area. Govt approved Indian labs test certificate required. Terrace Conductor Fibre Reinforce Concrete Holder @ every 1 meters
od347438/2021_2022 : Supply installation testing and commissioning of unitized substation (outdoor type) having 200KVA,11KV/433V, 3 phase, outdoor type, vector DYN-11transformer with off circuit tappings from +5% to -10% in steps of 2.5%, changeable on off circuit by tap links provided, with WTI & LV terminals included MCCB 2 runs of PVCA cable and HV terminals connected to 11 KV, 26.3 KA, 630 A Load Break Switch, with incoming suitable for XLPE cable, with HT HRC fuses,3 Nos CTs, 1 No PT, provision for fixing TOD Meter and output connected to 11KV seal off bushings to the transformer with an outer enclosure for outdoor use.The Transformer must be compatible with BMS system. Simalar to Siemens make or equivalent
od347439/2021_2022 : Supply and installation of IP65 rated LED Bulkhead fitting with aluminium diecast housing with powder coated ,Polycarbonate opal diffuser,High quality silicon gasket for IP65 Protection,Ambient temp-0 to 45 DegC,LED with 50000 burning hours as per L70 Criteria, CRI>70, color temperature- 5700K, , Complete assembly with LED, Driver and accessories pre wired up to terminal block Driver With efficiency>85%, THD<10%, Power factor>0.95, Surge protection in CM2KV, Multistage Isolated Constant Current- Constant Voltage Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. 10W LED Bulkhead luminaire delivering 720lm, similar to WIPRO make : LW07-141-XXX- 57- G1 or equivalent in Philips/ Jaquar
od347440/2021_2022 : Supply and installation of LED suspended downlighter should have white powder coated pressure die cast aluminium housing and bottom frame , lumen output greater than 1000 lm and maximum system wattage of 10W including separate CC,CV APFC driver with surge protection of 2 kV. LM 80-08 compliant, ANSI rated LEDs from reputed makes should be provided. The LEDs used in luminaire should be ANSI standard Rated LED with CCT of 4000 K +/- 500K and CRI of Minimum 70. LEDs used must be tested as per EN62471 for photo biological safety of humans. Isolated type, multistage constant current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with driver efficiency greater than 85%. LED tube should have THD < 10%, power factor > 0.9, system efficacy of lamp greater than 100 lumen/watt and including all necessary accessories as required complete
od347441/2021_2022 : Supply and installation of 15W, High efficient retrofit matching recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI>80, IP20, Ambient temp-0 to 45DegC, CCT -4000/5700K, 50,000 hrs @ L70 life. Driver efficiency>85%, THD<10%, Power factor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Wipro make: LD06-171-XXX-57-XX or equivalent in philips/ havells
od347442/2021_2022 : Supply and installation of 18W, High efficient deep inset recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI>80, IP20, Ambient temp-0 to 45DegC, CCT - 4000/5700K, 50,000 hrs @ L70 life.Driver efficiency>85%, THD<10%, Power factor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Wipro make: LD06X-221-XX-57-XX or equivalent
od347443/2021_2022 : Supply and installation of 35W, High efficient suspended LED Housing made up of extruded Aluminum powder coated and non-yellowing PMMA diffuser. Aesthetic slim profile in ring type with edge lit concept for contemporary interiors. Revolutionary disc of light with horizontal plane creates circle of light.CRI>80, IP20, Ambient temp-0 to 45 Deg C, CCT - 4000K, 50,000 hrs @ L70 life. Driver efficiency>85%,THD<15%, Power factor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver<br>with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen 2625 lm. Wipro make :LM230R-621-XX57-XW or equivalent in Philips
od347444/2021_2022 : Supply and installation of Integral, SMD LED, IP40,40W Surface/Suspended Mounted LED Batten with system efficacy of greater than 100 lm/W. LED luminaire shall have sleek design with Extruded Aluminum Section. The luminaire shall have High Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. Screw less Design ensures ease of maintenance. LM 80-08 compliant LEDs from reputed makes should be provided. LEDs used in the product shall comply with EN 62471 for Photobiological safety an certificate for the same from manufacturer shall be provided. Luminaire manufacturer shall produce certificate of association with LED manufacturer for minimum five years. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 3 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012 Wipro Model No. LL24-541-XXX-57-XX or equivalent
od347445/2021_2022 : Fabrication, supply, conveyance, installation testing and commissioning of floor mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 2mm thick CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary multifunction meters, CT's, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The panel must be compatible with B M S system . ( M S B Panel)<br>INCOMER: 320A,50KA, 4P MCCB with E/F - 2 nos<br>325A 4P CONTACTOR- 2no<br>AMF relay with interlock- 1 no<br>51G relay- 1 no<br>Busbar mounting Surge protection device (50 KA) - 1 set (RYB &N)<br>OUTGOINGS:<br>125A ,25KA, TP, MCCB - 2nos<br>100A , 25KA, TP,<br>MCCB - 2 nos<br>200A FP MCCB - 2nos<br>200A TP MCCB - 1no
od351377/2021_2022 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switchgear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary multifunction meters,CT's, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process, etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. (UPS Panel ) INCOMER : 200 AFP MCCB OUTGOINGS: 125 TP MCCB - 3 Nos 63A TP MCCB - 2 Nos
od351378/2021_2022 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary multifunction meters, CT's, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly . (Utility Panel) INCOMER : 63 A TPN ISOLATOR OUTGOINGS: 40A TP MCB - 2 Nos 32A TP MCB - 2Nos 25A TP MCB - 2 Nos of standard make as approved by the site engineer in charge(LMR)
od351379/2021_2022 : Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary multifunction meters, CT's, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly.(AC Panel) INCOMER: 100A TPN ISOLATOR OUTGOINGS:63A TP MCB - 3 Nos 40A TP MCB - 3Nos of standard make as approved by the site engineer in charge(LMR)
od351380/2021_2022 : Supply installation testing and commissioning of 40 KVAr APFC panel with block reactors. The voltage rating of the Power Factor correction requirement shall be at 440 Volts between phases. The total KVAR shall be divided into automatically switched steps of suitable rating. The no. of switching stages shall be designed appropriately in steps of ,15*1, 10*1& 5*3 for 40 KVAr. Individual Capacitors shall be of 3 phase construction in design using Heavy Duty Polypropylene as a dielectric with vacuum deposited conductors on the polypropylene as electrodes. Dielectric material shall be low loss, less than 0.3 watts per KVAr. The controller should be fully automatic, intelligent microprocessor based relay operated offering minimum 8 stage. The enclosure shall be made from 14/16 gauge CRCA sheet steel. Seven tank process shall be carried out for treating the sheet metal of standard make as approved by the site engineer in charge(LMR)
od353222/2021_2022 : DOCUMENTATION & APPROVAL. Preparation of necessary forms, documents, drawings etc. and procuring approval and energization certificate from the Electrical Inspectorate, and getting power from KSEB. All expenses except statutory charges shall be met by the Contractor.
JBR INDUSTRIES
Chanakya Nirman Private Limited
Bidder Name
JBR INDUSTRIES
Chanakya Nirman Private Limited
Ether builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .