Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.1 CrAccepted-AOC JAIN TEMPLE ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | ₹13.1 Cr Quoted ₹13.3 Cr | 1 | Accepted-AOC Being lowest and reasonable |
| 2 | 2₹14.2 CrRejected-Finance | ₹14.2 Cr | 2 | Rejected-Finance Not being lowest |
| 3 | 3₹15.4 CrRejected-Finance | ₹15.4 Cr | 3 | Rejected-Finance Not being lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Due to adverese remarks in WLR |
Tender Value
₹14.2 Cr
EMD Value
₹10.3 L
Closing Date
30 Apr 2019, 6:00 pmClosed
HQ CE AF SZ
HQ CHIEF ENGINEER (AF) SHILLONG ZONE MES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
PROVISION OF DEFICIENT LIVING IN ACCN AND AIRMEN MESS AT AF STN KUMBHIGRAM
2018_MES_214163_4
88395/KUM/E8
Open Tender
Civil Works
665 days
AGE I KUMBHIRGRAM
As per tender documents
6 documents required · 6 mandatory
₹3,000
AGE I AF KUMBHIRGRAM
₹10.3 L
Yes
28 Apr 2020
9 Mar 2019
6 May 2019
9 Mar 2019
30 Apr 2019
8 Apr 2019
9 Mar 2019 - 22 Mar 2019
Amount
SCHEDULE "A" Part - I (BUILDING WORKS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.
Construction of 40 Nos Single Living in Accn for CPLs / ACs (Double storey) complete all as specified and as shown on drawings.
Construction of 33 Nos Single Living in Accn for CPLs / ACs (Double storey) complete all as specified and as shown on drawings.
Construction of Dinning Hall and Cook house for CPLs / Acs (Single Storey) complete all as specified and as shown on drawings.
Construction of Airmen Institue (Single Storey) complete all as specified and as shown on drawings.
SCHEDULE "A" PART-II ( SITE CLEARENCE AND EARTH WORK ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD / PATH) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (FOUNTAIN AND COVERED SHED) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (GARBAGE BIN) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XI (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XII (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XIII (WATER COOLER AND AIR CONDITIONING ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XIV (SOLAR WATER HEATING SYSTEM) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XV (Demolition / Dismantling) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART -XVI (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES.
S & F for LED light fitting, 1x20 Watt , 230 Volts indoor decorative aluminium extruded T5 LED Battens-integrated type, with bipin holders , connector block, etc.complete with all accessories pre-wired and including connecting up with three core twisted flexible copper conductor cable of size 22/0.0076 all as specified and as directed. MAKE: C&S electric cat No. LTTB4F20WLED/W or equivalent make as mentioned in List of Makes.
S & F for 1 x 9 Watt LED light fitting indoor decorative round recess PDC aluminium housing slim down lighter integrated type with bipin holders, connector block etc working with 230 Volts, AC with all accessories including LED lamp and necessary electric connection with using required size copper cable complete all as specified and as directed. Make: C&S Cat No LTCRSLM9HPLEDRND/W or equivalent make as mentioned in List of Makes.
S & F for 1 x 36 Watt LED pressure die cast aluminium housing LED street light lumaniare fittings with heat resistant toughened glass with lens and suitable for working with 230 Volts, AC Supply with all accessories including LED lamp and necessary electric connection with using required size copper cable with and including 40 mm bore GI pipe (Light grade) bracket of 1.5 m long bend to shape as required, and fixed with clamp made out MS flat iron of size 40 mm x 5 mm and applying two coats of syenthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified and as directed.complete all as specified and as directed. Make: C&S Cat No LTESS14x2.5HPLED or equivalent make as mentioned in List of Makes.
S & F for ceiling fan 1200 mm sweep 240 volt AC, 5 star rating including down rod of suitable size, connected with twin core twisted flexible wire copper conductor cable with suitable size from ceiling rose to ceiling fan complete all as specified and as directed. Make: HAVELLS CAT NO. ES-50 5 Star or equivalent approved make as per list of make
S & F for Exhaust fan 300 mm sweep,1400 RPM, 240 volt, AC and including connected with twin core twisted flexible wire copper conductor cable with suitable size from ceiling rose to Exhaust fan complete all as specified and as directed. Make Havells Cat No. Turbo Force SP or equivalent approved make as per list of make.
S & F for sheet metal enclosure MCB DB, 4 way with 200 amp rated bus bar VTPN double door DB (IP 43 & IK- 09 tested by ERDA & CPRI), designed and manufectured as per IS: 8623- 1 & 3, glow wire tested, colour RAL 9003 white with provision for surface and flush mounting, reversible door provsion, field fittable key lock position, removable frame, centre plate and gland plate with incoming MCBs and outgoing MCBs complete all as specified and as directed.
S & F for MCB SP 6 to 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and directed
S & F for MCB SP 40 to 63 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and directed
S & F for MCB SPN 6 to 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and as directed
S & F for MCB SPN 40 to 63 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and as directed
S & F for MCB TPN 40 to 63 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and as directed
S & F for MCB TPN 6 to 32 Amps (C-Curve), breaking capacity 10 KA, 240 volts with cable connection and copper lugs complete all as specified and as directed
S & F for sub main wiring with 2 runs of single core 6 Sqmm (Nominal area) PVC insulated unsheathed multi-stranded copper conductor cable LT 1100 Volts grade (FR-LSH), drawn through in and including PVC rigid conduit pipes of required size including earth continuity conductor using PVC insulated unsheathed copper conductor cable of size 6 Sqmm (Nominal area) (FR-LSH) connected to common earth dolly complete all as specified and as directed. Note: A. Two runs of 6 sqmm, one run of earth continuity conductor of 6 sqmm cable and one run of PVC conduit shall be measured as one run length. B. Cutting chases, making good disturbed surface shall be included in quoted lump sum of schedule 'A' Part-I and nothing extra shall be paid on this account.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized steel wire 4mm dia earthing lead upto 7.5m from testing point fixed by means of galvanized iron or steel bolts nuts check nuts and washers, GI earth wire protected by 15mm bore light grade galvanized iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore medium grade galvanized iron, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness)all around the earth electrode with concrete earth pit in PCC (1 : 3 : 6) type C-1, (using 20 mm graded stone aggregate) ,cast iron frame, 50mm thick pre-cast RCC M-25 design mix cover slab size 450x450x50 mm reinforced with 8mm dia TMT bar 10cm C/C and suitable handle of 10mm dia round bar and MS angle iron 50x50x6 mm frame including two coats of painting over a coat of red oxide primer to exposed steel surface including necessary excavation, earth work in soft/loose soil and disposal off spoil to a distance n.exc 50m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part I and as directed.
S & F for 15 mm bore angular stop cock cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle with long shank and cup, screwed for iron pipe complete all as specified and as directed.
S & F for chromium plated brass urinal spreader for fixing with 15 mm bore pipe complete all as specified and as directed
M & L for 200mm thick GSB (Granular sub-base) over compacted sub grade using broken boulders or quarried stone, interstices filled and specified grading rolled and consolidated to the required gradient and camber complete all as specified and as directed.
M & L for 150 mm thick (compacted thickness) (in two layers of 75 mm compacted thick each) Wet Mixed Macadam (WMM), using granite trap or basalt of grading 2 and rolled with power roller of 8-10 tonne capacity of required camber and gradient complete all as speicified and as directed.
Construction of septic tank for 300 users complete all as specified and as shown on drawings.
Construction of soakage well for 150 users complete all as specified and as shown on drawings.
S & F for Cast Iron Air valves with two air outlets of 50 mm dia and fixed up in water supply mains of size 100 mm complete all as specified and as directed.
S & F for water flow meter magnetic induction type of size 100 mm dia pipe including testing commissioning and connection etc complete all as specified and as directed.
M & L for construction of brick masonary valve pit of size 100 cm x 100 cm x 100 cm (internal dimensions) with one brick thick wall in cement mortar (1 : 4) on 100 mm thick PCC (1:4:8) D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, including PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in beding and coping and 10 mm thick cement plaster in CM (1:4) internally and externally upto 15 cm below ground level providing valve pit 40 mm X 40 mm X 6 mm angle iron frame all round the fixed point by means of 04 Nos holdfast 150 mm long made out of flat iron 40 mm X 6 mm embedded in PCC block (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) of size 250 mm X 200 mm X 150 mm including provision of hinges welded with Mild Steel cover 3 mm thick, MS handle of suitable and size welded with MS cover and suitable locking arrangement including 65 mm dia Godrej pad lock and 3 Nos. key and applying two coats synthetic enamel paint over a coat of red oxide primer on steel surface including necessary excavation and earth work in soft/loose soil complete all as specified and as directed.
Supply, install, testing and commissioning of 50000 litre capacity water storage tank made out of FRB sheet of size 1250 mm x 1250 mm of suitable thickness at 20 mtr staging including suitable foundation and footing as per manufacturer instruction as approved by GE on mild steel structural section complete all as specified and as directed.
Supply, install, testing and commissioning of Reverse Osmosis plant of cut out put capacity of 25 ltrs per hour before water cooler with all fixtures and fitting arrangements with and including additional one year AMC after defect liability period complete all as specified and as directed. Make: kent / Usha / Havells
S & F for weather proof out door street / security light control pillar box grouted in the foundation complete 63 amp aluminium busbar for 3 phase and neutral, suitable for comprising the following componenets, including cable termination, wirings, earth work, PCC foundation etc complete all as specified and as directed. a) MCB TPN 32 Amp- 01 No b) Time Switch with auto with battery back up type and relay. MAKE: Hensal or equivalent make as mentioned in List of Makes.
S & F for 1 x 60 watt LED streetlight made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 energy saving and environmental friendly roadway luminaire with electronic driver including connection with 4 Sqmm aluminium conductor complete all as specified and as directed. Make: Havells cat No LHETBXU7PA6J060 or equivalent make as mentioned in List of Makes.
S & F for 08 watt Cone series acts as a imposing street furniture.the elegant yet minimalsitic design acts a silent observer and giving light, diffuser at the upper portion acts a beacon of path guidance in a landsacpe environment, IP 65, 240 volt with all accessaries and prewired with copper cable of suitable size 1100 volt, fixed in pcc foundation tighten with suitable nut bolt and base plate complete all as specified and directed. Make: Havells Cat Part No LHENABP7IZ6KOO8 or equivalent make as mentioned in List of Makes.
Supply, installation, testing and commissioning of CPRI approved LT feeder pillar box, outdoor type, IP 54 as per IS 13947, weather and vermin proof, canopy on top over all size 900 mm x 600 mm x 400 mm made out of 3 mm thick CRCA sheet with all necessary frame work with angle iron of required size not less than 50 mm x 50 mm x 6 mm, cubical type duly powder coated paint over a coat of red oxide zinc chrome primer and aluminium bus bar of 300 Amps for three phase and neutral duly PVC laminated - 4 Nos including internal wiring by FR-LSH grade multistranded PVC insulated copper conductor of size not less than 1.5 sqmm duly marked, plate for fixing MCCB, MCB etc with the following accessories and provision of PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as foundation of feeder pillar box and bedding upto a height of 30 cm above gorund level complete all as specified and as directed. (a) MCCB 4 pole, 415 V, 125 Amps 25 KA - 01 No (b) MCCB 4 pole, 415 V, 100 Amps 25 KA - 05 Nos (c) MCB TPN 63 Amp 'C' series - 03 Nos (d) MCB TPN 32 Amp 'C' series- 01 No
Supply, installation, testing and commissioning of CPRI approved LT feeder pillar box, outdoor type, IP 54 as per IS 13947, weather and vermin proof, canopy on top over all size 900 mm x 600 mm x 400 mm made out of 3 mm thick CRCA sheet with all necessary frame work with angle iron of required size not less than 50 mm x 50 mm x 6 mm, cubical type duly powder coated paint over a coat of red oxide zinc chrome primer and aluminium bus bar of 400 Amps for three phase and neutral duly PVC laminated - 4 Nos including internal wiring by FR-LSH grade multistranded PVC insulated copper conductor of size not less than 1.5 sqmm duly marked, plate for fixing MCCB, MCB etc with the following accessories and provision of PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as foundation of feeder pillar box and bedding upto a height of 30 cm above gorund level complete all as specified and as directed. (a) MCCB 4 pole, 415 V, 250 Amps 36 KA - 01 No (b) MCCB 4 pole, 415 V, 150 Amps 36 KA - 01 No (c) MCCB 4 pole, 415 V, 125 Amps 25 KA - 04 Nos (d) MCCB 4 pole, 415 V, 100 Amps 25 KA - 03 Nos (e) MCB TPN 63 Amp - 01 No
M & L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on complete all as specified and as directed.
Materials and labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with copper strip of size 25 mm x 3 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on complete all as specified and as directed
Supply and install voltage stabilizer automatic operation, single phase, naturally air cooled, AC supply 50 cycle, indoor type wall or floor mounted and designed for input variation between 160 Volt to 260 Volt with and output voltage stabilzed at 220V with accuracy + 2.5% and capacity 5 KVA with time delay relay, under /over voltage relay and overload relay complete all as specified and as directed.
Supply and install voltage stabilizer automatic operation, single phase, naturally air cooled, AC supply 50 cycle, indoor type wall or floor mounted and designed for input variation between 160 Volt to 260 Volt with and output voltage stabilzed at 220V with accuracy + 2.5% and capacity 4 KVA with time delay relay, under /over voltage relay and overload relay complete all as specified and as directed.
Supply and install voltage stabilizer automatic operation, single phase, naturally air cooled, AC supply 50 cycle, indoor type wall or floor mounted and designed for input variation between 160 Volt to 260 Volt with and output voltage stabilzed at 220V with accuracy + 2.5% and capacity 2 KVA with time delay relay, under /over voltage relay and overload relay complete all as specified and as directed.
Supply and install voltage stabilizer automatic operation, single phase, naturally air cooled, AC supply 50 cycle, indoor type wall or floor mounted and designed for input variation between 160 Volt to 260 Volt with and output voltage stabilzed at 220V with accuracy + 2.5% and capacity 1 KVA with time delay relay, under /over voltage relay and overload relay complete all as specified and as directed.
S & F for laying suitable electric / refrigerant copper pipe lines in between indoor and outdoor units beyond the standard length (5 m) for split ACs, including proper insulation, through wall / ceilling / floors etc complete all as specified and as directed.
S & F for sub main wiring with 2 runs of single core 4 Sqmm (Nominal area) PVC insulated unsheathed multi-stranded copper conductor cable LT 1100 Volts grade (FR-LSH), drawn through in and including PVC rigid conduit pipes of required size including earth continuity conductor using PVC insulated unsheathed copper conductor cable of size 4 Sqmm (Nominal area) (FR-LSH) connected to common earth dolly complete all as specified and as directed. NOTES: 1. Three runs of 4 sqmm and one run of PVC conduit shall be measured as one run length. 2. Cutting chases, making good disturbed surface shall be included in quoted lump sum of schedule 'A' Part-I and nothing extra shall be paid on this account.
Supply and install of refrigerator electric driven, single phase of capacity 310 ltrs double door, frost free, shiny steel, five star rating complete all as specified and as directed. MAKE: LG / Samsung / Haier
Supply install and testing of electrical Chimney of stainless steel body, size 1.5 m x 1 m and exhaust size 30 cm x 30 cm with 300 mm sweep heat resistant exhaust fan omplete all as specified and as directed. Make: Hindware / Faber / Glen / Butterfly / Elica
Supply, install, testing and commissioning water pumping set, horizontal type, 15 m head, 10000 LPH, 2 HP, SP, 220 V, 50 Hzfor water fountain including necessary base plate fixing arrangement, starter panel board etc complete all as specified and as directed. Make: Crompton Greaves / Kirloskar or equivalent make as mentioned in List of Makes.
S & F for submersible cable, flat type, 3 core, copper conductor, standard, 2.5 sqmm overall sheathed complete all as specified and as directed.
S & F for under water type LED light fitting, stainless steel body and frame complete all as specified and as directed.
S & F for gun metal / stainless steel fountain nozzles with necessary pipe and fixing arrangements etc complete all as specified and as directed.
S & F for electronic charger of under water luminaries including cabling and fixing arrangements etc complete all as specified and as directed.
Bringing approved earth (Suitable for plantation) from out side MOD land mixed with 50% sand, approved fertilizer / vermin composite mixture @ 1Kg per Cum and herbiside 30 ml per cum including spreading and levelling averaging 30 cm thick to receive carpet grass, different flower plant and ornamental leaf plant to desired gradient complete all as specified and as directed.
Supply and planting approved Korian carpet grass / lawn grass by dibbing method and maintaining the lawn for a period of three year including weeding out unwanted grass and irrigating the area by sprinkling water, spraying of fertilizer and insectisides etc as required complete all as specified and as directed.
Supply and planting approved plants of ornamental variety like Durenta, Golden durmda, Koynel, Lantena etc including excavation in trenches 45 cm wide and 45 cm in deep in hard / dense soil cleaning of any type of weeds in an around the plantation area and filling with approved agricultural soil mixed with fertilizer @ 0.1 kg for each plant and maintaining for three year including sprinkling water and weeding out unwanted grass / wild growth around the shurbs through out the maintenance period complete all as specified and as directed.
Supply and planting approved shurbs, Bougainvilla, Roses, Nerium, Dalia, Luxora, dreasenia, TMC, Marrigold, Harbiscus, kesam dhama, Gelidolius, sunflower etc having minimum height not less than 60 cm from ground level after plantation with and including excavation pits of size 60 cm x 60 cm x 60 cm depth of hard / dense soil and filling with approved aggricultural soil manuring with fertilizer @ 0.1 kg for each shurbs including watering loosening of soil fortnightly, trimming, prunning, stacking and spraying insectisides and fungicides as and when required and maintaining for three year including sprinkling water and weeding out unwantd grass / wild growth around the shurbs throughout the maintenance period complete all as specified and as directed.
Supply and planting hedges (Golden erica, green erica, Vrindavani red hedge, Australian cookies, Thuja) at 10 cm by ploughing the soil upto 15 cm depth and maintaining for a period of three year and upto the hedge growth upto 6 cm heigh including necessary watering, application of fertiliser, cleaning the weeds time to time including near by area throughout the maintenance period complete all as specified and as directed.
Supply and planting approved palm tree (jamaica / Triangular / Chanpiana) including excavation in pits of size 60 cm x 60 cm x 70 cm deep in hard / dense soil mixed with approved fartilizer @ 0.2 kg Per plant including maintaining for a period of three year complete all as specified and as directed.
Demolition of building constructed with CGI sheet roofing, false ceiling, timber scantling, lathplastering and PCC flooring and brick work etc of various building of plinth area approx 44.09 sqm to 305.78 sqm each, total 13 Nos building complete all as specified and as directed.
Dismantling of old unserviceable MCB / Isolator of any type / kind etc complete all as specified and as directed.
Dismantling of old unserviceable sub main wiring any size from board after taking all necessary precautions and making good of disturbed surface after repair / replacement has been done complete all as specified and as directed.
Taking down service connection wire of 6 sqmm and 10 sqmm complete all as specified and as directed.
Taking down old sluice valve of size 80 to 125 mm complete all as specified and as directed.
Note: Schedule of credit (SCHEDULE 'A' PART- XVII) amount of Rs 1136639.50 mentioned on Page No 40 shall be deducted from the total quoted amount of BOQ.
Golden Traders
Allied Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid