| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹27.4 L+₹2.6 L (10.6%)Rejected-Finance | L2 | Rejected-Finance Rejected being not lowest | |
| 3 | L3₹29.3 L+₹4.6 L (18.5%)Rejected-Finance | L3 | Rejected-Finance Rejected being not lowest | |
| 4 | L4₹31.9 L+₹7.2 L (29.0%)Rejected-Finance MATTILIPARAMBIL HOUSE SAHODHARAN AYYAPPAN ROAD EROOR WEST PO THIRUPUNITHURA 682306 | THIRUPUNITHURA | ERNAKULAM | KERALA | 682306 | L4 | Rejected-Finance Rejected being not lowest | |
| 5 | L5₹35.1 L+₹10.3 L (41.8%)Rejected-Finance CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | L5 | Rejected-Finance Rejected being not lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
15 Jun 2021, 6:00 pmClosed
SK Choudhary IDSE EE GE NW Kochi
GE NW Kochi Kataribagh Naval Base Post Pin 682004
COMPREHENSIVE MAINT AND PETTY REPAIR OF INTERNAL WIRING ELECTRICAL FITTINGS AND FIXTURES FANS AND GEYSERS OF K L M AT NAVAL BASE KOCHI UNDER GE NW KOCHI
2021_MES_443576_1
8481
Open Tender
Electrical and Maintenance Works
Works
365 days
GE NW Kochi Kataribagh Naval Base Post Pin 682004
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
₹90,000
7 Aug 2021
18 May 2021
17 Jun 2021
19 May 2021
15 Jun 2021
31 May 2021
Amount
Taking down Copper /aluminium point wiring (light ,fan ,socket ,bell,power point ) complete fitting such as switches ,ceiling roses ,pendants,regulators,sockets ,light fitting any type,building security light removing materials to store for keeping in safe custdoy for taking credit to match with existing suface all as specified and directed by Engr -In-Charge.
M&L Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLSH cable 1100 Volts grade including PVC casing and caping and connected accessories ISI marked with concealed sunken boxes with modular cover plate , PVC boxes, hylem sheet , including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLSH cable single core multistranded cable as earth continuity wire for one light / fan point controlled by one switch complete all as specified and as directedby engr in charge .
All as per item No 2 here-in-before but for one bell point controlled by one push button on independent board compleate all as specified and directed by Engr -In-Charge. .
All as per item No 2 here-in-before but for 5 pin 5 Amps socket outlet point on independent board all as specified and directed by Engr -In-Charge.
All as per item No 2 here-in-before but for 5 pin 5 Amps socket outlet point on same board all as specified and directed by Engr -In-Charge.
All as per item No 2 here-in-before but using 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cableand 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable earthwire with terminal box of suitable size of modular switch & socket for one 6 pin 15 Amp socket outlet point on independent board all as specified and directed by Engr -In-Charge.
Material and labour for point wiring for one light/fan point with 1.5 sqmm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC Conduit medium grade ISI marked Concealed of suitable size with all accessories and sunken box of 1.6 mm thick and 60 mm Depth pressed steel box factory made for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and as directed by the Engr-in-Charge.
All as per item No 6 here in before but for one bell point controlled by one 5 Amp bell push on independent board complete all as specified and directed.
All as per item No 6 here in before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and directed by Engr -In-Charge.
All as per item No 6 here in before but for one 5 pin 5 Amp socket outlet point on the same board all as specified and directed by Engr -In-Charge.
All as per item No 6 here in before but using with 2.5 Sqmm copper conductor cables multistranded (FRLSH) PVC insulated , unsheated cable and including 2.5 Sqmm copper conductor cable multistranded(FRLSH) PVC insulated and unsheated cable as earth continity wire and connecting to common earth dolly for one 6 pin 15 Amp socket outlet point on independent board all as specified and directed by Engr -In-Charge.
S & F in repair, bell push flush type 5 Amps single pole all as specified and directed by Engr -In-Charge.
S & F in repair, electric bell, AC 230 Volt single pole all as specified and directed by Engr -In-Charge.
S & F in repair, switch piano flush type single pole one way 5 Amp one way all as specified and directed by Engr -In-Charge.
S & F in repair, switch piano flush type single pole one way 15 Amp all as specified and directed by Engr -In-Charge.
S & F in repair, socket outlet 5 Amps, 5 pin, 2 in 1 all as specified and directed by Engr -In-Charge.
S & F in repair, socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 all as specified and directed by Engr -In-Charge.
S & F in repair, switch socket combination 5 Amps, 5 pin 2 in 1 , all as specified and directed by Engr -In-Charge.
S & F in repair fan regulator electronic step type 100 W, 250 Volts all as specified and directed by Engr -In-Charge.
S & F in repair fan regulator electronic step type 100 W, 250 Volts all as specified and directed by Engr -In-Charge.
S & F in repair, capacitor 2.5 MFD for ceiling fans all as specified and directed by Engr -In-Charge.
S & F in repair, lamp holder ,PVC /poly carbonate type with back plate suitable for batten fittings all as specified and directed by Engr -In-Charge.
S & F in repair, ceiling rose surface bakelite 65 x 50 mm, 3 all as specified and directed by Engr -In-Charge.
M&L in repairs sub main wiring with 4 runs of 10 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI Marked, medium grade, non metallic, PVC Casing & Capping and all accessories, with 1 run of 10 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLSH, and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls/floors/ceiling etc all as specified Note:- Five run of cable and one run of PVC casing and caping shall be measured as one unit
All as per item No 24 here-in-before but 2 runs of 4 sq mm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing all as specified and directed by Engr -In-Charge. Note:- Three run of cable and one run of PVC casing and caping shall be measured as one unit
All as per item No 24 here-in-before but 2 runs of 2.5 sq mm single core FRLSH copper conductor and 1 run of 2.5 sqmm conductor for earthing all as specified and directed by Engr -In-Charge. Note:- Three run of cable and one run of PVC casing and caping shall be measured as one unit
M&L in repairs sub main wiring with 4 runs of 16 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI Marked, medium grade, non metallic, PVC conduit white colour and all accessories, with 1 run of 16 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLSH, and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls/floors/ceiling etc all as specified and directed by Engr -In-Charge. Note:- five run of cable and one run of PVC conduits shall be measured as one unit
All as per item No 24 here-in-before but 2 runs of 1.5 sq mm single core FRLSH copper conductor and 1 run of 1.5 sqmm conductor for earthing all as specified and directed by Engr -In-Charge. Note:- Three run of cable and one run of PVC conduits shal be measured as one unit
S & F in repair Sheet Metal Enclosure for MCB DB, TPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB all as specified and directed by Engr -In-Charge.
S & F in repair Sheet Metal Enclosure for MCB DB, SPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB all as specified and directed by Engr -In-Charge.
S & F in repair Sheet Metal Enclosure for MCB DB, SPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB all as specified and directed by Engr -In-Charge.
S & F in repair MCB, TPN, 63 Amps, 415 Volt, b curve, having breaking capacity 10 kA all as specified and directed by Engr -In-Charge.
S & F in repair MCB, TP, 63 Amps, 415 Volt, b curve, having breaking capacity 10 kA, all as specified and directed by Engr -In-Charge.
S & F in repair MCB, TPN, 32 Amps, 415 Volt, b curve, having breaking capacity 10 kA,all as specified and directed by Engr -In-Charge.
S & F in repair MCB, SPN, 63 Amps, 415 Volt, b curve, having breaking capacity 10 kA,all as specified and directed by Engr -In-Charge.
S & F in repair MCB, SP, 6-32 Amps, 240 Volt, b curve, having breaking capacity 10 KA, all as specified and directed by Engr -In-Charge.
S & F in repair MCB, SPN, 6-32 Amps, 240 Volt, b curve, having breaking capacity 10 kA, all as specified and directed by Engr -In-Charge.
S & F in repair 20 watt LED tube double side with batten ,universal type , 230V,50 Hz,wall surface ,roof surface including connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal all as specified and directed by Engr -In-Charge. cat part no -,CRYSTAL1213T8DSTL20WLED865SGLASS(Tube) and REGALBATTENT8UPTO1X22WSSBSWH (Batten) of Havells or crompton,surya .
S & F in repair Led glass T8 tube 20 watt, 220 volt ,50 Hz, LED tube rod, double side connection,inbuilt driver , all as specified and directed by Engr -In-Charge. cat part no -CRYSTAL1213T8DSTL20WLED865SGLASS of havells ,surya ,crompton
S & F in repair LED light fitting 24 W, high performance batten , 220 volt ,50 Hz,6500 k surface mounted high quality extruded polycarbonate ,enviromental friendly ,energy efficient , with all connecting accessories ,with suitable connection all as specified and directed by Engr -In-Charge. cat part no-LHEXACP7IN1S024 of havells,crompton ,surya
S & F in repair LED light fitting 20 W, high performance batten , 220 volt ,50 Hz,6000 k surface mounted high quality extruded polycarbonate ,enviromental friendly ,energy efficient , with all connecting accessories ,with suitable connection all as specified and directed by Engr -In-Charge. cat part no-LHEXBLP7PN1W020 of havells,crompton ,surya
S & F in repair LED light fitting 18 W, high performance batten , 220 volt ,50 Hz,6000 k surface mounted high quality extruded polycarbonate ,enviromental friendly ,energy efficient , with all connecting accessories ,with suitable connection all as specified and directed by Engr -In-Charge. cat part no-LHEXBLP7PN1W018 of havells,crompton ,surya
S & F in repair LED light fitting 10 W, highperformance batten , 220 volt ,50 Hz, surface mounted high quality aluminium extruded with all connecting accessories ,with suitable connection complete all as specified.cat part no-LDL-10-CDL of crompton
S & F in repair 15 Watt Square recessed mounted down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit all as specified and directed by Engr -In-Charge. cat part no - LSDE-15-CDL of crompton,surya,havells .
S & F in repair 12 Watt Square recessed mounted down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit all as specified and directed by Engr -In-Charge. cat part no - LSDE-12-CDL of crompton,surya,havells .
S & F in repair 15 Watt recessed round down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit all as specified and directed by Engr -In-Charge. cat part no - LSCRM-15W-CDL of crompton, philips ,wipro. .
S & F in repair 12 Watt recessed round down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit. complete all as specified cat part no - LSCRM-12W-CDL of crompton, philips ,wipro. .
S & F in repair 12 Watt surface mounted round down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit all as specified and directed by Engr -In-Charge. cat part no - LCSR-12-CDL of crompton, philips ,wipro. .
S&F In repair focus light 7 watt 50 hz,230 volts with all accessories and connection to the electric all as specified and directed by Engr -In-Charge. cat part no - LSP07 of Luker, crompton, philips ,wipro. .
S&F in repair indoor wall mounted light 12 watt ,140 volt to 265 volts,IP-20 ,50 Hz ,aluminium housing with all accessories and connection to the electrc circuit all as specified and directed by Engr -In-Charge. cat part no -LWL105 of luker or havells ,crompton .
S&F in repair indoor wall mounted light suitable for led bulb any wattage ,220 volts ,50 Hz ,with all accessories and connection to the electrc circuit all as specified and directed by Engr -In-Charge. cat part no LHJE01104499 of Havells or Luker ,crompton .
S/F in repair , Ball bearing made out of high carbon steel, equivalent to the original, suitable for any type, any make, any size fans all as specified and directed by Engr -In-Charge.
S/F in repair Bush bearing, made out of brass alloy, equivalent to the original, suitable for any type, any make, any size, fan all as specified and directed by Engr -In-Charge.
S/F in repair Nickel plated mild steel clamps, Nuts, Bolts, Washers and split pin suitable for ceiling fans any type, any make, any size all as specified and directed by Engr -In-Charge.
S/F in repair Down rod, suitably threaded and holed, made out of 15 mm dia GI tubes, duly painted, 450 mm long, suitable for ceiling fans any type, any make, any all as specified and directed by Engr -In-Charge.
S/F in repair Fan canopy with tightening screw/check nut, made out of PVC, suitable for ceiling fans any type, any make, any size all as specified and directed by Engr -In-Charge.
S/F in reapir Rubber reel insulator, suitable for ceiling fans any type, any make, any size all as specified and directed by Engr -In-Charge.
M & L for hanging hook for ceiling fan with nuts bolts and washer min thickness 5 mm compleate all as specified and directed by Engr -In-Charge.
S/F in repair Fan blades for 1200 mm sweep fan made out of 1.2 mm thick Aluminium alloy and MS screws duly balanced & colour White or Brown , Set of three, suitable for ceiling fans of any type, any make compleate all as specified and directed by Engr -In-Charge.
S/F, in repair Fan blades made out of Acrylic / PVC alloy and MS screws duly balance suitable for 450/400 mm wall fans of any type, any make, for the following size compleate all as specified and directed by Engr -In-Charge.
S/F in repair exhaust fan blades for 250 mm / 300 mm sweep exhaust fan made out of 1.2 mm thick Aluminium alloy and MS screws duly balanced & spray painted with approved colour, suitable for Exhaust fans of any type, any make compleate all as specified and directed by Engr -In-Charge.
S/F in repair exhaust fan blades for 450 mm sweep exhaust fan made out of 1.2mm thick Aluminium alloy and MS screws duly balanced & spray painted with approved colour, suitable for Exhaust fans of any type, any make compleate all as specified and directed by Engr -In-Charge.
Taking down unserviceable ceiling fan of 1200mm/1400mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No compleate all as specified and directed by Engr -In-Charge.
Taking down unserviceable exhaust fan of 450/300/250 mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No compleate all as specified and directed by Engr -In-Charge.
Taking down unserviceable wall mounted fan of 400 /450 mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including cleaning of fan compleate all as specified and directed by Engr -In-Charge.
M & L in repair Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c , 20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion completeall as specified. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
S & F in repair Modular Bell push 6A, 1module, compleate all as specified and directed by Engr -In-Charge.
S & F in repair in repair Fan Regulator, modular electronic rotary,0-4 steps step type 100 Watt, 240 Volt 50 Hz hum free 2 module compleate all as specified and directed by Engr -In-Charge.
S & F in repair switch modular 6 Amps 240 Volts one way switch compleate all as specified and directed by Engr -In-Charge.
S & F in repair Socket 6 Amps AC 240 Volts 2/3 pin combined 2 modular type compleate all as specified and directed by Engr -In-Charge.
S & F in repair Socket 6A/16 Amps-2/3 pin combined AC 240 Volts modular type compleate all as specified and directed by Engr -In-Charge. Make -Legrand,havells ,honeywell.
S & F in repair Switch modular type AC 240 volts 16 Amps one way compleate all as specified and directed by Engr -In-Charge.
S & F in repair Switch modular type AC 240 volts 16 Amps one way compleate all as specified and directed by Engr -In-Charge.
S & F in repair sunken box with Modular white cover plate 4 module with removing old type sunken boxes /wooden board and match with existing surfaces compleate all as specified and directed by Engr -In-Charge.
S & F in repair sunken box with Modular white cover plate 6 module with removing old type sunken boxes /wooden board and match with existing surfaces compleate all as specified and directed by Engr -In-Charge.
S & F in repair sunken box with Modular white cover plate 8 module with removing old type sunken boxes /wooden board and match with existing surfaces compleate all as specified and directed by Engr -In-Charge.
S & F in repair sunken box with Modular white cover plate 12 module with removing old type sunken boxes /wooden board and match with existing surfaces compleate all as specified and directed by Engr -In-Charge.
S & F in repair SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug compleate all as specified and directed by Engr -In-Charge.
S & F in repair triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug compleate all as specified and directed by Engr -In-Charge.
M & L in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 6 sq.mm 2 core including taking down old unserviceable cable compleate all as specified and directed by Engr -In-Charge.
M & L in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 10 sq.mm 4 core including taking down old unserviceable cable compleate all as specified and directed by Engr -In-Charge.
M & L in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 16 sq.mm 4 core including taking down old unserviceable cablecompleate all as specified and directed by Engr -In-Charge.
S & F in repair cercular highbay Led light 110 Watt ,240 volt , min lmumens 110 Lm/w ,IP 66 including provision of flexible copper wire from ceiling rose to light fitting terminal compleate all as specified and directed by Engr -In-Charge. cat part no -LHB11-110-CDL/60 of crompton or surya,havells .
S & F in repair LED cercullar Flood Light 30 Watt,50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminious efficiancy and high power compleate all as specified and directed by Engr -In-Charge. Cat part no-LFLN11-30-CDL of crompton ,surya ,havells .
S & F in repair LED Flood Light 50 Watt,50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminious efficiancy and high power compleate all as specified and directed by Engr -In-Charge.Cat part no-LFLE-50-CDL of crompton ,surya ,havells .
S & F in repair LED Flood Light 60 Watt,50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminious efficiancy and high power compleate all as specified and directed by Engr -In-Charge.Cat part no-LFL-60-CDL/60 of crompton ,surya ,havells .
S & F in repair LED building security light 25 watts ,50 Hz,220 volts having IP-65 protection, pressure die cast aluminium housing, high luminious efficiancy and high power compleate all as specified and directed by Engr -In-Charge.Cat part no-ENDURAPEARLSL25WLED757SASYTOPC of Havells or surya ,crompton .
S & F in repair LED building security light 40 watts ,50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminious efficiancy and high power compleate all as specified and directed by Engr -In-Charge.Cat part no-ENDURAPEARLNEOSL40WLED757PASYTOPC of Havells or surya ,crompton .
Material,labour including transportion of tools for rectification of urgent nature of electrical complaints like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of MCBs, small pieces of wires including connections etc carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs to ceiling fans / exhaust fans like replacement of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functional at kataribagh area ,MES colony ,Ellision Avenue,Sanjivani hospital,shopping complex area during off hours (1700 hrs evining to 0900 Hrs morning ) on all working days compleate all as specified and directed by Engr -In-Charge. NOTE:- (i) The material incorperated for completion of work will be measured and paid seperately under relevent item. (ii) The contractor should display contact number at complaint cell to register users complaint. (iii) The recovery of rupees 400 per complaints will be charged if contractor failed to attend that instipulated time period . (iv) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly.including in all aspects like labours,tool,transportation etc.
Material,labour including transportion of tools for rectification of urgent nature of electrical complaints like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of MCBs, small pieces of wires including connections etc carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs to ceiling fans / exhaust fans like replacement of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functional at kataribagh area ,MES colony ,Ellision Avenue,Sanjivani hospital,shopping complex area during off days including sunday and holiday days all as specified and directed by Engineer-in-Charge. NOTE:- (i) The material incorperated for completion of work will be measured and paid seperately under relevent item. (ii) The contractor should display contact number at complaint cell to register users complaint. (iii) The recovery of rupees 400 per complaints will be charged if contractor failed to attend that instipulated time period . (iv) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly.including in all aspects like labours,tool,transportation etc.
M&L for checking of ceiling fans stability (like fan hooks,nuts, bolts ,hanging rod ,canopy ,washer etc ) exhaust fan stability ,loose connection in destribution boards,MCBs in qtrs compleate all as specified and directed by Engr -In-Charge. Note - 1. The material incorperated for completion of work will be measured and paid seperately under relevent item. 2. The contractor should prepaired a register and enter qtr number with signature of occupant and submited to engineer in charge office. 3. Checking of all fans and DBs in a qtr at a time ishall be considered as one job
M&L for checking of ceiling fans stability (like fan hooks,nuts, bolts ,hanging rod ,canopy ,washer etc ) exhaust fan stability ,loose connection in destribution boards,MCBs in office area compleate all as specified and directed by Engr -In-Charge. Note - 1. The material incorperated for completion of work will be measured and paid seperately under relevent item. 2. The contractor should prepaired a register and enter office name with signature of offce incharge and submited to engineer in charge office. 3. Checking of 7 fans and 2 DBs of any type at a time is shall be considered as one job
M & L for checking of faulty / jumped energy meter (three phase /single phase ) with fixing of new energy meter in series and after one week submmitted meter reading report of both energy meter in engr in charge office compleate all as specified and directed by Engr -In-Charge.
Supply & fix in repair recess mounted commercial luminaire 36 watt ,50 Hz ,220 volts,5700 K LED down lighter 2'x2' compleate all as specified and directed by Engr -In-Charge. cat part no -LCTRH-36-CDL of Crompton ,philips ,havells
Supply & fix in repair recess mounted/surface mounted commercial luminaire 36 watt ,50 Hz ,220 volts,5700 K LED down lighter 2'x2' compleate all as specified and directed by Engr -In-Charge. Make :- Crompton ,philips ,havells
N.O. Antony Contractors
M/s ANTONY THOMAS AND CO
Oriental Constructions
ANIE JOHN CONTRACTORS
Green Ray Enterprises
Jack Electrolinks Private Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .