| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹47.9 L+₹1.4 L (3.11%)Rejected-Finance SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹48.0 L+₹1.5 L (3.27%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹48.4 L+₹1.9 L (4.16%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹48.7 L+₹2.2 L (4.76%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
7 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-T-25/2023-24 REPAIR TO FIRING, RANGE, ARMOURY AND CERTAIN INTERNAL AND EXTERNAL WORKS IN TECHNICAL AREA AT (AF) STN AMBALA UNDER GE (AF) AMBALA
2023_MES_603737_2
GE AF/AMB-T-25/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER
10 documents required · 10 mandatory
₹500
GE AF AMBALA
₹94,000
Yes
11 Sept 2023
19 Jul 2023
9 Aug 2023
19 Jul 2023
7 Aug 2023
26 Jul 2023
Amount
M & L for Forming embankments including raising earth raising from base, spreading in layers not exceeding 30cm thick, watering, ramming / rolling and finishing to required size, shape, etc. complete all as specified and as directed for the following levels (Note: The approved earth/soil to be brought fom out side of the MOD land).
Height not exceeding 1.5m, complete all as specified and as directed
Height exceeding 1.5m but not exceeding 4.5m, complete all as specified and as directed
Height exceeding 4.5m but not exceeding 6m, complete all as specified and as directed
M&L for Sand filling under floors/ firing range,Pavement or in foundations including watering and consolidation complete all as specified and as directed Note : any type of height firing range,
Supply and laying saw dust in small range firing but with compacted thickness complete all as specified and as directed Note: any type of height firing range
Taking down cement plaster from brick or stone wall etc including racking out joint, hacking for key scrubbing down with water etc complete all as specified and as directed by Engineer-in-charge.
M&L for rough cast plaster including 15mm thick rendering in CM 1:3 on brick wall or concrete concrete surfaces complete all as specified in SSR Part - I clause 14.22 complete all as specified and directed. Note : Rough cast finish to be as below :- After applying the under coat of cement mortar 1:3 and while it is still in plasic state the rough cast mixture consisting of crushed stone or fine gravel agg (which is generally of size between 6 to 12mm depending on the texture required ) mixed with course sand and cement in the ratio of 1 : 1 : 1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger agg are thoroughly covered.
M&L rendering 15mm thick on fair face of brick walls or concrete surfaces in CM 1:4 mixed with WPC as per manufactures specification finished even and smooth without using extra cement complete all as specified and as directed
Supply only integral water proofing compound/ complete all as specified and directed by Engr-in-Charge.
Material & Labour for preparation of newly plastered surfaces and applying two coat of exterior acrylic emulsion paint over a coat of primer in camouflaging pattern of any shape and to any pattern complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge.
M & L for Cement concrete 1:4:8, type D2 (using 40mm graded stone agg in foundations,filling and mass concrete) as in sub base of floors complete all as directed.
M&L 40mm thick PCC 1:2:4, type B 1, (using 20 mm graded stone aggregates) as in floor finish even and smooth using extra cement complete all as specified and as directed .
Material and labour for 75 mm thick cement concrete type C-2, 1:3:6 ( using 20 mm graded aggregates) as in path/pavings/plinth protection etc laid in bays incl finishing the concrete surface even and smooth without using extra cement complete all as specified and as directed
Demolition of brick work bult in cement mortar incl all quoins arches, pillars etc complete all as specified and directed by Engr-in-Charge.
Material and labour for brick work with sub class `B` brick old size in CM 1:4 straight or curved on plan exc 6m mean radious in drain etc. complete all as specified and directed by Engr-in-Charge. Note : Any type of hight
All as per item No 17.00 (here-in-before) but except bricks, complete all as specified and as directed. Note :- Serviceable bricks obtained from Sl No 16 shall be used after proper cleaning.
Material and labour for 15 mm thick Rendering on brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified .
Supply and fixing in repairs, vitreous china urinal , half stall type white with gratings, union for discharge pipe , flush pipe and waste pipe , CP urinal spreader fixed to water supply pipe etc complete all as specified and directed.
Supply and fixing in repairs, vitreous china urinal partition ,white of size 310 x 700mm etc complete all as specified and directed.
Supply and fixing in repairs coloured oval type wash hand basin, size 580x450 mm, white, flat back, (for Hospilal use) excluding taps, waste, chain and plug and porcelain stopper but including brackets waste pipe 32mm, coupling etc fixed as in counter slab etc complete all as specified and directed .
Supply and fixing in repairs Toilet paper holder, cast copper alloy, chromium plated fixed in position, complete all as specified and as directed.
Supply and fixing in repair vitreous china wash down water closet pedestal pattern white excluding fixing bolts , flushing cistern and flush pipe complete but including PVC seat cover with aluminium hinges devices & EWC jet chromium plated with 1.00 mtr long PVC connection pipe complete all as specified and directed.
Supply and fixing in repair CP grating of size 125mm complete all as specified and as directed
Dismantling of stone slabs and tiles of any description or thickness laid dry or laid dry and pointed in any mortar in floors, aprons etc complete all as specified and as directed.
M&L for Sand filling under floors/Pavement or in foundations including watering and consolidation complete all as specified and as directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 80mm thickness, M-40 Grade with grey cement and no pigment complete all as specified and as directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment complete all as specified and as directed
Material and labour PCC 1:2:4, type B-1, (using 20mm graded mechanincally crushed stone aggregates) as in bonding/locking of edges of interlocking tiles including weathering and slightly rounded or chamfered on edges and threating including necessary form work complete all as specified and directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and removing serviceable tiles to store yard and rubbish off the premises complete all as specified and as directed.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) jointless area of each tile exc 0.06 but not exc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed with white or colour cement to match the surface.over screed bed or bedding layer 15mm thick in cement mortar 1:4 complete all as specified and directed.
M&L for coloured glazed designer ceramic tiles 300 x 450 x 7 to 8mm thick on vertical surface as in dado/skirting and jointed in neat cement slurry and pointed with white/colour cement to match with the surface over 15mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for vetrified ceramic tiles 10mm thick in light/dark shade (square/rectangular) area of each tile n. exc 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed with white or colour cement to match the surface.over screed bed or bedding layer 15mm th in cement mortar 1:6 complete all as specified and directed.
All as per srl item No 35.00 here-in-above but as in skirting including 10mm thick in CM 1:4 rendering as in backing coat complete all as specified and directed.
Dismantling old unserviceable RCC/PVC water tank of capacity exc 250 but n. exc 500 ltrs cpacity including supply and fixing PVC water storage tank of 500 ltrs capacity HDPE double layered , cylindrical type fixed and hoisted in position on roof at any height complete with inlet/outlet of 20mm GI pipe connection including locking arrangement with ball valves high pressure with epoxy coated aluminium rod and high density plastic ball fixed as in repairs complete all as specified and directed.
Supply and fixing in repairs, 15 mm bore Bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
Supply and fixing in repairs, PVC valveless, syphonic action type, flushing cistern (ISI marked) of 10 litres capacity, low level (white) with inlet, ball valve, float and handle including bracket and flush pipe complete all as specified and as directed.
Supply and fixing in repairs fancy type stop valve/angle valve/concealed stop cock cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes of 15mm bore complete all as specified and directed.
Supply and fixing in repairs PVC connection 60cm long with brass check nuts on both sides suitable for 15mm bore pipe etc complete all as specified and directed.
Taking down existing fencing wire mesh of any description complete all as specified and as directed.
Supply and fixing chain link MS galvanised fencing of any size or type including line wires, any mesh, any size and type of standards, rails, straining bolt etc including provn of binding wire etc complete all as specified and directed.
Supply and fix mild steel screw bolt with hexagonal or square head at one end and screwed at the other end with washer & one hexagonal nut not exc 5 cm long & 5 to 10mm dia complete all as specified and as directed.
Material and labour for mild steel round bars 10mm dia and above as supporting horizontal bars in chain link fencing, incl binding and bonding complete all as specified and as directed.
Dismantling posts or struts of steel or RCC any section including taking out embedded portion from conrete or masonry and making good disturbed ground complete all as specified and as directed.
M&L Preparation of new or previously untreated steel surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a priming coat of Red oxide, zinc chrome primer, complete all as specified and as directed
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
Supply and fixing MS framed work as in doors or gates of angle or other sections with gusset plates, rails, braces, etc complete drilled for fixing to steel sheeting or other covering, doors, etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging, also fastening and fixing complete conforming to Fe-410-W complete all as specified and directed.
Supply and fixing in angles iron post & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire incl all necessary drilling bolts or rivetting & similar work confirming to Fe- 410-0 or Fe 310-0 and flat iron 40x4mm fillets (for securing chain link fencing etc) complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting any gauge , thickness, including Nainital or similar pattern from roof covering and wall Cladding complete all as specified and directed.
S&F Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Material and labour for one coat of synthetic enamel paint preparation of old painted steel surfaces as in walls / roof trusses/purlins/rafters/angle iron posts etc complete all as specified and directed.
Excavation in post holes each n exc 0.5 cum getting out, returning, filing in and removing earth or brocken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m in soft/loose soil and making good surface as per existing surface complete all as specified and directed.
Material and labour for cement concrete 1:2:4, Type D-2, (using 40 mm graded stone aggregates) as in foundation filling or mass concrete complete all as specified and as directed.
Material and labour for preparing surfaces of new or previously untreated surfaces of steel or metal works and applying two coats of synthetic enamel paint over a coat of rex oxide primer over 10cm in width or girth complete all as specified and as directed
S&F in repair galvanised , two strand , steel barbed wire 2.24mm dia barbed with 2mm dia bars at 75mm spacing and straining and fixing to any type of standard rail, straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc complete all as specified and directed. Note : - The work is to be carried out at any height of security wall etc. Necessary T&P, scaffolding, to carry out the above work is also included in quoted rate.
Supply and fixing in repairs PVC (SWR) 110mm bore as soil waste and vent pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
All as per srl item No 59.00 here-in-above but 75mm bore complete all as specified and directed.
Supply and fxing PVC (SWR) bends any radius for 110mm pipe complete all as specified and as directed.
All as per item No. 61.00 here-in-above but for 75mm pipe complete all as specified and directed.
M&L for complete removal of existing treatment from plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of 1mm putty complete all as specified and directed.
Material and labour for one coat of synthetic enamel paint on old painted wooden surfaces of any description exc 10cm width or girth including preparation of surfaces etc complete all as specified and directed.
M & L for Chequered/Designer cement concrete tiles 20mm thick,set, jointed and pointed in neat cement slurry in floors with pigment over a screed bed of 15mm thick in CM 1:6, complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth/width and getting out loose/soft soil for laying of under ground cable complete all as specified and directed.
Returning/ filling including spreading, levelling and well ramming in layers not exc 25cm in thick complete all as specified and directed.
Removal of surplus soil to a distance not exc 50m away and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and spread sand in cable trenches and providing cushioning for the cable complete all as specified and directed. Note:- Only punned thickness of 18cm will be measured for the purpose of payment.
Supply and lay burnt brick of size 230x115x75mm for protection of cable, laying in trenches perpendicular to the axis of cable complete all as specified and directed.
M&L for Make bore to road/cement path/hard standing for providing GI pipe 50/40mm both end socketed for passing armoured cable incl making good the disturbed surface complete all as specified.
S&F in replacement GI tubing of 50mm dia light grade at road cross for protection cable as per site requirement and sealing the pipe both ends with sealing compound complete all as specified and directed.
All as per item No.72.00 here-in-above but 40mm dia complete all as specified and directed.
Supply and Laying in replacement LT underground cable XLPE insulated and sheathed armoured cable 1100 volts 4 core 16 Sqmm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and directed by Engineer-in-Charge.
All as per srl item No.74.00 here-in-above but of cable 3.5 core 25 Sqmm complete all as specified and directed.
All as per srl item No.74.00 here-in-above but of cable 3.5 core 50 Sqmm complete all as specified and directed.
All as per srl item No.74.00 here-in-above but of size 3.5 core 95Sqmm complete all as specified and directed.
S&F lugs for UG cable for 3.5/4 core 16Sqmm to 50Sqmm complete all as directed by Engineer-in-Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed by the Engineer in Charge.
M&L Point Wiring using approved colour coding as per IS with Zerohalogen flame retardent (ZHFR) smoke free non toxic non corrosive with copper cable 1.5 sqmm (nominal area) single core insulated and unsheathed stranded cable 1100 Volts grade and including (ERW) stove enamelled concealed conduit heavy duty ISI marked complete all as specified and directed for one light point controlled by one way switch and 1.5 Sqmm copper conductor green in color as earth continuity conductor complete all as specified and directed. Note:- Rate of cutting chasing,Pinning in & making good shall quoted in unit rates.
All as per srl item No.80.00 here-in-before but with 2.5 Sqmm for power socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engr-in-Charge.
All as per srl item No.80.00 (here-in-before) but with 4 Sqmm for power socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engr-in-Charge.
M&L flame proof weather proof switch socket & plug combined with cable termination box in LM6, 16 A 250V (2P + earth) complete all as specified and directed.
M&L flame proof weather proof switch socket & plug combined with cable termination box in LM6, 25 A 250V (2P + earth) complete all as specified and directed.
M&L for in replacement sub main wiring alongwith earth wire with 3 x 2.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including ERW stove enamelled Steel Conduit heavy duty ISI marked and its all accessories of suitable size concealed complete all as specified and directed by Engr-in-Charge. Note: Three runs of 2.5 Sqmm copper cable and one run of above steel conduit shall be measured as one unit length.
M&L for submain wiring alongwith earth wire with 3 x 4 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including ERW stove enamelled Steel Conduit heavy duty ISI marked and its all accessories of suitable size concealed complete all as specified and directed by Engr-in-Charge. Note: Three runs of 4 Sqmm copper cable and one run of above steel conduit shall be measured as one unit length.
S&F in replacement LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in replacement Switch flame Proof rotary type with termination box in LM-6 16 A single Pole 240 V complete all as specified and directed.
S&F in replacement Flameproof LED bulkhead light fittings 25 watt, 230V, IP-65, 50Hz complete all as specified and directed.
M & L for brazing/welding of copper strip at joint complete all as specified and directed.
In replacement M&L for Air termination, single pointed aluminium rod 12 mm dia and 300 mm long incl fixing base plate with insulator complete fixing on the top roof of the hanger complete all as specified and directed.
In replacement S&F Test point terminal block made of gun metal phosphorus bronze, size 75x75x25mm drilled and screwed incl 3 Nos 8mm dia 25mm long hexagonal head screw, complete all as specified and directed.
M&L for earthing complete with copper earth plate electrode 600mmx600mmx3.15 mm thick buried directly in ground earth pit not less than 3 mtr below ground level with top edge of earth plate not less than 2.25 mtrs below found level connected to copper earth strip of 20x3 mm by two means of nuts, bolts, thimbles, chuck nuts, washers test points including one end firmly fixed with earth plate by means of nut and bolts and other end of copper strip to test point GI watering pipe, 20mm dia duly plugged shall be projected out at least 20 cms above the ground level incl covering the earth electrode with charcoal dust salt all around not less than 15cm provision of earth pit RCC cover all as shown in electrical plate No. 3 of SSR Part I, 2009 etc incl necessary earth an disposal of surplus soil complete and testing all as specified and directed. Note : The Earth result should be less than 3 ohm and the result will be checked in presence MES Rep.
M&L for PCC 1:2:4, type B 1, (using 20mm graded stone aggregates) as in coping etc including form work as required at site complete all as specified and directed.
S&F end joint kit in replacement for 1.1 KV grade suitable for outdoor/indoor type terminal heat shrinkable type joints with jointing material for 3.5/4 core XLPE armoured aluminium conductor cable of size 16/25 Sqmm complete all as specified and directed.
All as per item No.95.00 here-in-above but of cable 3.5 core 35/50Sqmm complete all as specified and directed.
S&F jointing kit in replacement for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 16 to 50 Sq mm complete all as specified and directed.
M&L for Aluminium strip 25x3mm with saddle on and including on FRP insulator fixed on wall/MS sheet or floors incl connecting to lightening arrester/earthing/test point strip should be brazed/welded at each joint complete all as specified and directed.
M&L for copper strip 20x3mm with saddles on FRP insulator fixed on wall/MS sheet or floors incl connecting to lightening arrester/earthing/test point strip should be brazed/welded at each joint complete all as specified and directed.
S&F in replacement security light bracket with 40mm bore GI tubing, light grade, cut and bent to shape required, 1.2m long fixed with including bends, flat iron clamp made of FI 40x6mm, nuts, bolts, washers, etc. duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specfied and as directed
S&F in replacement energy efficient LED street light fitting, 90W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-80, lumen efficacy ≥100 lumen/watt, THD> 20, CRCA housing including all fixing arrangement like clamps, nuts, bolts, washers, 90W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down the old unserviceable fittings complete complete all as specified and directed.
S&F in replacement energy efficient LED flood light fitting, 120W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI>70, PF>0.9, minimum 25000 burning hours, THD> 20, CRCA housing including all fixing arrangement like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations complete all as specified and as directed
M&L Preventive maintenance of Normal GI/copper earth pit by checking earth resistance value of earth and maintain the record before and after treatment of earth by pouring of Mixture of chemicals like sodium carbonate , magnesium sulphate , common salt, charcoal etc for improving the earth resistance value it also includes any excavation required at site all as directed.
M&L Preventive maintenance of Chemical earth pit by checking earth resistance value of earth and maintain the record before and after treatment of earth by pouring of chemical compound used in chemical earthing etc for improving the earth resistance value less than 1 ohm it also includes any excavation required at site all as directed.
M&L for digging of cable loop of LT XPLE cable of any size with all necessary excavation and return filling and replacing the end joint / straight through joint kit in replacement for 1.1kV grade with provision of jointing material for 3.5 core XLPE armoured aluminium conductor cable of any size complete all as specified and as directed Note: End/straight through joint will be measured and paid seperately under respective items herein. All other requistes shall be deemed to be included in the quoted rate
S&F in replacement rectangular type earth pit cover made out of heavy duty cast iron of size 12"x12" with MS frame of suitable size incl all necessary masonary work for fixing of earth pit cover incl replacement of wire mesh( jali) ,funnel including painting of plain PCC earthing pits surface by preparing new untreated surface,applying priming paints coats y two coats followed by two coats synthetic enamel paint all as directed by EIC.
JS CONSTRUCTION COMPANY
M/s Kang Builders
M/S SHASTRI BUILDERS AND ENGINEERS
M/S VINOD RANA CONTRACTOR
Bairagi Builders
M/s Hari Om Engineer and Contractor
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .