Assistant Executive Engineer
Electrical Wing Irrigation Subdivision Chalakkudy
GENERAL DTPC Palakkad Renewal of Garden lights at Band stand area in Malampuzha Garden Providing new lights in Malampuzha garden General Electrical Work
2025_Irrig_745698_6
C-ETN-MAR/EL/24-25
Open Tender
Electrical Works
Item Rate
120 days
Chalakkudy
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,805
₹20,418
29 Jul 2025
28 Apr 2025
19 May 2025
28 Apr 2025
17 May 2025
28 Apr 2025
Amount
Renewal of Garden Lights
OD208959/2024-2025:Supply , Conveyance, installation, testing and commissioning of 45w LED Post Top with minimum 4500 Lumens light output in 4000K CCT, minimum 335mm diameter, 100 Lumens per watt system efficacy, IP65 with IK07 Protection for the full luminaire, 4kv internal Surge Protection, 140v - 277v Operating Voltage range and 325V High cut-off of Philips BGP201 LED45 NW PSU GR CPC SPD /Techno Commercial equivalent or equivalent of outdoor type LED fittings directly on the existing pipe/ pole and giving connections with the existing wiring etc as required
OD211910/2024-2025:Supply , Conveyance, installation, testing and commissioning of 27w LED Post Top with minimum 2700 Lumens light output, minimum 570mm diameter, 100 Lumens per watt system efficacy, IP66 with IK08 Protection, 10kv Surge Protection, 3000- 4000K CCT and CE Certified product of Philips BGP161 LED2500/NW PSU 220-240V 7043 IN /Techno Commercial equivalent or equivalent of outdoor type LED fittings directly on the existing pipe/ pole and giving connections with the existing wiring etc as required
OD110315/2024-2025:Dismantle the existing dysfunctional post top light and convey to the section store and stack safely.
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
OD270082/2024-2025:Supply and fixing Syntex junction box GSJB 1816 or equivalent with provision for fixing SP/DP MCB for terminating street light cable.
90.3.17.1:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.32 mm dia GI pipe
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
P. PRADEEPAN (BID ID -2212793)
Bidder Name
ARUN.C.S
P. PRADEEPAN
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1240694.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .