Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹3.4 Laccepted-aoc | ₹3.4 L | accepted-aoc |
Tender Value
₹3.9 L
EMD Value
₹9,700
Closing Date
4 Apr 2026, 3:00 pmClosed
Divisional Engineer-(Electrical), Tirumala
Line Inspector
Providing of 50 sq.mm 3 1/2 core UG cable from toilet at PPV dam old existing outdoor pillar box to dam water flow chamber at PPV dam,Tirumala
917213
404/DE(Elec)Tml/TTD/2025-26
OPEN - NCB
Electrical Works
TIRUPATHI
7 documents required · 7 mandatory
₹137
₹9,700
19 Apr 2026
21 Mar 2026
21 Mar 2026
Supply and transportation of 50 Sq.mm 3 1/2 core LT XLPE insulated, 1100V grade armoured Aluminium UG cable as per specification confirming to IS:7098 (Part-I) / 1554-1. Grade-A: Make: Torent / Universal / Unistar / Havells / KEI / Gloster / Polycab / RR Kabel / Finolex.
Supply and fixing of fabricated M.S clamps made out of 25mm x 3mm MS flat with necessary holes on either side with suitable 1 1/2" coach screws and painting 2 coats of enamel black paint over one coat of red oxide suitable for fixing of UG Cables of size 25 Sq.mm to 50 Sq.mm on walls etc., including all labour charges etc., complete.
Supply and Transportation of Outer dia 63mm and Inner dia 51mm double walled corrugated HDPE duct made as per specification BSEN - 500 86/IS 14930 Part-II. Makes:DURA LINE (Dura Guard)/Precision/CPE or any ISI approved make having ISI mark.
Earth work excavationin all soils excepts sand or loose soil, SDR etc., for pipe line for drainage and water supply and electrical where the depth is 11/2 times or more than width and depositing the excavated earth with in a lead of 10 metres.
Cutting open Cement concrete road surface with concrete saw cutter and removal with Breaker.
Cement Concrete using 20mm (0.54cu.m) and 12mm (0.36cu.m) nominal size hard broken granite crushed metal from any source conforming to the relevant ISI standards for foundations etc., laidin layers o not more than 15cm thick well compacted including curing,, machine mixing, costand conveyance of all materials etc., complete. Note : Measurement boxes shall be used form easuring the quantities of cement, aggregate and water required for the given concrete mix - C.C (1:3:6)
Only Laying of U.G cables upto 50 Sq.mm and back filling of trench including labour charges etc., complete.
Providing of Independent Chemical Earthing after excavating an earth pit of size1.5 m X 0.9 m X 2.05 m(Top 1.50 m X 0.90 m X 0.9m & bottom 1.20 m X 0.90 m X 1.15 m) with the following specification: (a) The Earth Electrodes, 40mm dia, wall thickness 3.25 mm, terminal Size 25x8 mm, terminal hole dia 12 mm, 2 meter long, galvanized, including 1 bag (25Kg to a bag) of Earth Life Compound, as per IS 3043, Base Metal: IS marked branded mild steel pipes. Makes: Potential / Shake Hands / Mars / Tirumala / Arshlok earthing. b) The Earth Electrode shall be inserted into the ground for 1.75 Mtrs. Below the inspection chamber bottom 300mm all around this Earth Electrode shall be covered with 25 Kgs. Of Earth Life Compound (c) The excavated gap shall be back filled with excavated earth, and shall be properly consolidated with water.
(d) The top 0.25 m of Earth pipe shall be exposed into inspection chamber of Hume pipe . The all around inspection chamber shall be providied with 18" dia hume pipe. Earth connections shall be given to the Earth Elecrods with bolts, nuts & washers. (e) A 65 mm dia PVC conduit is to be embeded through hume pipe at one side, to lay the Earth from the Earth bus to the Electrode through the PVC conduit and after laying the Earth, the pit entry PVC conduit is to be sealed with Bitumen compound. (f) Necessary Meggar testing is to be done in the presence of the concerned Engineers, and the reading should be as per IE standards.
Supply and run of 25mm X 6mm G.I Strip for earth electrode to required places buried in ground at not less than 0.5 mtrs below the ground level after excavation of trench and filling with 6" sand all around the earth strip and refilling etc., and giving necessary connections with 3/8" x 2" G.I Bolts, Nuts and Washers wherever joints has to be done. The strip has to be either riveted (or) bolted (or) gas welding neatly and all labour charges etc., complete.
Design, fabrication, supply and errection of Distribution panel board made with 14 SWG CRCA sheet. The size of panel should be 1300mm x 900mm x 400mm and should be provide front door with locking arangements and rain shed with a measurments of 1100 mm x 600 mm. The entire box should be mounted on base ISMS MS Angle size 50x50x6mm with a stand legs at 4 corners at a length of 600mm using of 50x50x6mm MS angle with necessary welding two coats of enamel block paint over one coat of red oxide. The piller box should be fixed in ground with cement concrete using 20mm (1:3:6) of size of 0.5 (L) x 0.3 (W) x 0.5 (H) and fixing firmly as directed execution.
The following switch gears, bus bars etc. should be supply and fixing in the panel firmly, and the panel with necessary individual doors to bus bars/Outgoing Cable, MCCB Chamber, Incoming Cable Chamber etc. and should be accomidate in the box with necessary holes provided to the bottom sheet of the box for incomming/ out going cables. All the doors shall be provided with rubber beading and door knobs. The entire panel should be powder coated with siemens grey color through 7 tank process as directed during execution. 1) 1 No. of 250A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 36/35 KA with thermal magnetic release Panel Mounted. Makes: L&T / Schneider / Siemens / Hager 2) 1 No. of 125A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted. Makes: L&T / Schneider / Siemens / Hager
3) 4 Nos of LED indicator lamps on the existing box / panel board of make L&T / C&S / SALZAR / HPL. 4) 3 Nos. of 40-63A, TP MCB, C/D Curve ISI Mark. Makes: Legrand / Schneider. 5) 4 Nos of size 1" x 1/2" copper flat bits shall be fix in all MCCBs incomming/Outgoing for a provision of Cable termination arrangements. 6) 4 Nos of size 1" x 1/2" copper flat shall be run from MCCB out going to Horizontal bus bar chamber and also fix the bus bar with necessary insulator supports. 7) 4 Nos of size 3/4" x 1/8 copper flat shall be run from Horizontal bus bar chamber to Outgoing MCCBs of 125 A Outgoing MCCBs and Outgoing bits respectively and also fix the bus bar with necessary insulator supports. 8) Earth Terminal should be provide both side of the panel for earth flat connection. 9) 2 Nos of danger boards to be fixed to the board.
Design, fabrication, supply and errection of Distribution panel board made with 14 SWG CRCA sheet. The size of panel should be 1000mm x 1600mm x 400mm and should be provide front door with locking arangements and rain shed with a measurments of 1200 mm x 600 mm. The entire box should be mounted on base ISMS MS Angle size 50x50x6mm with a stand legs at 4 corners at a length of 600mm using of 50x50x6mm MS angle with necessary welding two coats of enamel block paint over one coat of red oxide. The piller box should be fixed in ground with cement concrete using 20mm (1:3:6) of size of 0.5 (L) x 0.3 (W) x 0.5 (H) and fixing firmly as directed execution.
The following switch gears, bus bars etc. should be supply and fixing in the panel firmly, and the panel with necessary individual doors to bus bars/Outgoing Cable, MCCB Chamber, Incoming Cable Chamber etc. and should be accomidate in the box with necessary holes provided to the bottom sheet of the box for incomming/ out going cables. All the doors shall be provided with rubber beading and door knobs. The entire panel should be powder coated with siemens grey color through 7 tank process as directed during execution. 2) 1 No. of 125A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted. Makes: L&T / Schneider / Siemens / Hager 3) 4 Nos of LED indicator lamps on the existing box / panel board of make L&T / C&S / SALZAR / HPL. 4) 4 Nos. of 40-63A, TP MCB, C/D Curve ISI Mark. Makes: Legrand / Schneider. 5) 4 Nos of size 1" x 1/2" copper flat bits shall be fix in all MCCBs incomming/Outgoing for a provision of Cable termination arrangements.
6) 4 Nos of size 1" x 1/2" copper flat shall be run from MCCB out going to Horizontal bus bar chamber and also fix the bus bar with necessary insulator supports. 7) 4 Nos of size 3/4" x 1/8 copper flat shall be run from Horizontal bus bar chamber to Outgoing MCCBs of 125 A Outgoing MCCBs and Outgoing bits respectively and also fix the bus bar with necessary insulator supports. 8) Earth Terminal should be provide both side of the panel for earth flat connection. 9) 2 Nos of danger boards to be fixed to the board.
NOTE (i)The rates are of basic rates excluding GST. (ii) The applicable GST will be reimbursed/paid as per actuals on production of proof. (iii)Statutory deductions will be made as per norms, if applicable. Any modalities imposed on GST by the Government from time to time, the same will be implemented.
Supply and transportation of 50 Sq.mm 3 1/2 core LT XLPE insulated, 1100V grade armoured Aluminium UG cable as per specification confirming to IS:7098 (Part-I) / 1554-1. Grade-A: Make: Torent / Universal / Unistar / Havells / KEI / Gloster / Polycab / RR Kabel / Finolex.
Supply and fixing of fabricated M.S clamps made out of 25mm x 3mm MS flat with necessary holes on either side with suitable 1 1/2" coach screws and painting 2 coats of enamel black paint over one coat of red oxide suitable for fixing of UG Cables of size 25 Sq.mm to 50 Sq.mm on walls etc., including all labour charges etc., complete.
Supply and Transportation of Outer dia 63mm and Inner dia 51mm double walled corrugated HDPE duct made as per specification BSEN - 500 86/IS 14930 Part-II. Makes:DURA LINE (Dura Guard)/Precision/CPE or any ISI approved make having ISI mark.
Earth work excavationin all soils excepts sand or loose soil, SDR etc., for pipe line for drainage and water supply and electrical where the depth is 11/2 times or more than width and depositing the excavated earth with in a lead of 10 metres.
Cutting open Cement concrete road surface with concrete saw cutter and removal with Breaker.
Cement Concrete using 20mm (0.54cu.m) and 12mm (0.36cu.m) nominal size hard broken granite crushed metal from any source conforming to the relevant ISI standards for foundations etc., laidin layers o not more than 15cm thick well compacted including curing,, machine mixing, costand conveyance of all materials etc., complete. Note : Measurement boxes shall be used form easuring the quantities of cement, aggregate and water required for the given concrete mix - C.C (1:3:6)
Only Laying of U.G cables upto 50 Sq.mm and back filling of trench including labour charges etc., complete.
Providing of Independent Chemical Earthing after excavating an earth pit of size1.5 m X 0.9 m X 2.05 m(Top 1.50 m X 0.90 m X 0.9m & bottom 1.20 m X 0.90 m X 1.15 m) with the following specification: (a) The Earth Electrodes, 40mm dia, wall thickness 3.25 mm, terminal Size 25x8 mm, terminal hole dia 12 mm, 2 meter long, galvanized, including 1 bag (25Kg to a bag) of Earth Life Compound, as per IS 3043, Base Metal: IS marked branded mild steel pipes. Makes: Potential / Shake Hands / Mars / Tirumala / Arshlok earthing. b) The Earth Electrode shall be inserted into the ground for 1.75 Mtrs. Below the inspection chamber bottom 300mm all around this Earth Electrode shall be covered with 25 Kgs. Of Earth Life Compound (c) The excavated gap shall be back filled with excavated earth, and shall be properly consolidated with water.
(d) The top 0.25 m of Earth pipe shall be exposed into inspection chamber of Hume pipe . The all around inspection chamber shall be providied with 18" dia hume pipe. Earth connections shall be given to the Earth Elecrods with bolts, nuts & washers. (e) A 65 mm dia PVC conduit is to be embeded through hume pipe at one side, to lay the Earth from the Earth bus to the Electrode through the PVC conduit and after laying the Earth, the pit entry PVC conduit is to be sealed with Bitumen compound. (f) Necessary Meggar testing is to be done in the presence of the concerned Engineers, and the reading should be as per IE standards.
Supply and run of 25mm X 6mm G.I Strip for earth electrode to required places buried in ground at not less than 0.5 mtrs below the ground level after excavation of trench and filling with 6" sand all around the earth strip and refilling etc., and giving necessary connections with 3/8" x 2" G.I Bolts, Nuts and Washers wherever joints has to be done. The strip has to be either riveted (or) bolted (or) gas welding neatly and all labour charges etc., complete.
Design, fabrication, supply and errection of Distribution panel board made with 14 SWG CRCA sheet. The size of panel should be 1300mm x 900mm x 400mm and should be provide front door with locking arangements and rain shed with a measurments of 1100 mm x 600 mm. The entire box should be mounted on base ISMS MS Angle size 50x50x6mm with a stand legs at 4 corners at a length of 600mm using of 50x50x6mm MS angle with necessary welding two coats of enamel block paint over one coat of red oxide. The piller box should be fixed in ground with cement concrete using 20mm (1:3:6) of size of 0.5 (L) x 0.3 (W) x 0.5 (H) and fixing firmly as directed execution.
The following switch gears, bus bars etc. should be supply and fixing in the panel firmly, and the panel with necessary individual doors to bus bars/Outgoing Cable, MCCB Chamber, Incoming Cable Chamber etc. and should be accomidate in the box with necessary holes provided to the bottom sheet of the box for incomming/ out going cables. All the doors shall be provided with rubber beading and door knobs. The entire panel should be powder coated with siemens grey color through 7 tank process as directed during execution. 1) 1 No. of 250A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 36/35 KA with thermal magnetic release Panel Mounted. Makes: L&T / Schneider / Siemens / Hager 2) 1 No. of 125A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted. Makes: L&T / Schneider / Siemens / Hager
3) 4 Nos of LED indicator lamps on the existing box / panel board of make L&T / C&S / SALZAR / HPL. 4) 3 Nos. of 40-63A, TP MCB, C/D Curve ISI Mark. Makes: Legrand / Schneider. 5) 4 Nos of size 1" x 1/2" copper flat bits shall be fix in all MCCBs incomming/Outgoing for a provision of Cable termination arrangements. 6) 4 Nos of size 1" x 1/2" copper flat shall be run from MCCB out going to Horizontal bus bar chamber and also fix the bus bar with necessary insulator supports. 7) 4 Nos of size 3/4" x 1/8 copper flat shall be run from Horizontal bus bar chamber to Outgoing MCCBs of 125 A Outgoing MCCBs and Outgoing bits respectively and also fix the bus bar with necessary insulator supports. 8) Earth Terminal should be provide both side of the panel for earth flat connection. 9) 2 Nos of danger boards to be fixed to the board.
Design, fabrication, supply and errection of Distribution panel board made with 14 SWG CRCA sheet. The size of panel should be 1000mm x 1600mm x 400mm and should be provide front door with locking arangements and rain shed with a measurments of 1200 mm x 600 mm. The entire box should be mounted on base ISMS MS Angle size 50x50x6mm with a stand legs at 4 corners at a length of 600mm using of 50x50x6mm MS angle with necessary welding two coats of enamel block paint over one coat of red oxide. The piller box should be fixed in ground with cement concrete using 20mm (1:3:6) of size of 0.5 (L) x 0.3 (W) x 0.5 (H) and fixing firmly as directed execution.
The following switch gears, bus bars etc. should be supply and fixing in the panel firmly, and the panel with necessary individual doors to bus bars/Outgoing Cable, MCCB Chamber, Incoming Cable Chamber etc. and should be accomidate in the box with necessary holes provided to the bottom sheet of the box for incomming/ out going cables. All the doors shall be provided with rubber beading and door knobs. The entire panel should be powder coated with siemens grey color through 7 tank process as directed during execution. 2) 1 No. of 125A 4 Pole MCCB, Adjustable, Confirms to IS/IEC 60947-2 having Breaking Capacity 35/36 KA with thermal magnetic release Panel Mounted. Makes: L&T / Schneider / Siemens / Hager 3) 4 Nos of LED indicator lamps on the existing box / panel board of make L&T / C&S / SALZAR / HPL. 4) 4 Nos. of 40-63A, TP MCB, C/D Curve ISI Mark. Makes: Legrand / Schneider. 5) 4 Nos of size 1" x 1/2" copper flat bits shall be fix in all MCCBs incomming/Outgoing for a provision of Cable termination arrangements.
6) 4 Nos of size 1" x 1/2" copper flat shall be run from MCCB out going to Horizontal bus bar chamber and also fix the bus bar with necessary insulator supports. 7) 4 Nos of size 3/4" x 1/8 copper flat shall be run from Horizontal bus bar chamber to Outgoing MCCBs of 125 A Outgoing MCCBs and Outgoing bits respectively and also fix the bus bar with necessary insulator supports. 8) Earth Terminal should be provide both side of the panel for earth flat connection. 9) 2 Nos of danger boards to be fixed to the board.
NOTE (i)The rates are of basic rates excluding GST. (ii) The applicable GST will be reimbursed/paid as per actuals on production of proof. (iii)Statutory deductions will be made as per norms, if applicable. Any modalities imposed on GST by the Government from time to time, the same will be implemented.
(Rupees Three Lakhs Eighty Five Thousands Five Hundred Ninety Six and paise Five Only)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BOQ 404.xls
TENDER_DOCUMENT • 2.01 MB
NIT 404.docx
TENDER_DOCUMENT • 0.17 MB
NIT 404.xlsx
TENDER_DOCUMENT • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].