| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹18.5 L+₹2.3 L (14.3%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-AOC Rejected being higher bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Not recommended since neither enlisted in c(i) nor similar nature work experience uploaded |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jodhpur
GE (AF) Jodhpur
REPAIR OR REPLACEMENT AND SERVICING OF SPLIT WINDOW TYPE AC AND ALLIED WORKS AT AF STN JODHPUR
2023_MES_582442_2
8546/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹40,000
Yes
20 May 2023
24 Mar 2023
15 Apr 2023
24 Mar 2023
13 Apr 2023
1 Apr 2023
Amount
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Rotary compressor) 1.5 Tonne capacity, single phase, 230 volt including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage rectification , and Supply & Fixing of new compressor of same capacity and make including gas charging R-22/R-407C and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Rotary compressor) 2 Tonne capacity, single phase, 230 volt including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage rectification , and Supply & Fixing of new compressor of same capacity and make including gas charging R-22/R-407C and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Inverter compressor) 1.5 Tonne capacity, single phase, 230 volt including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage rectification and Supply & Fixing of new compressor of same capacity and make including gas charging R-410 A and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for disconnecting, cutting and taking out unserviceable sealed unit (Inverter compressor) 2 Tonne capacity, single phase, 230 volt including necessary modification of the foundation as required to suit the new compressor, vacumisation, pressure, testing, leakage rectification and Supply & Fixing of new compressor of same capacity and make including gas charging R-410 A and testing complete all as specified & directed by the Engineer-in-Charge.
Material & labour for Water Jet servicing of Split type AC of 1.5/2.0 Tonne capacity (complete indoor and outdoor unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top cover outdoor top cover from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge.
Material & labour for Water Jet servicing of WINDOW TYPE AC's of 1.5/2.0 Tonne capacity (complete unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the complete unit from existing location, cleaning of cooling coil , condenser coil, and other components using clean water greasing of fan, motor, blower etc without damage any part and reinstall at the same location complete all as specified & directed by the Engineer-in-Charge. Note for Srl Item No.5 & 6 above :- The contractor shall at his own cost arrange water for servicing purpose and also clean the wall & Floor surfaces after servicing and make it neat and tidy to the entire satisfaction of Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 2.5 MFD, 230 volts, 50 HZ suitable for indoor unit complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 4 MFD, 230 volts, 50 HZ suitable for indoor unit complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 6 MFD, 230 volts, 50 HZ complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 45 MFD, 230 volts, 50 HZ complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs Running capacitor of capacity 50 MFD, 230 volts, 50 HZ complete all as specified & directed by the Engineer-in-Charge.
Taking down existing condensing fan motor from the unit and Material & labour for rewinding of condensing fan motor of suitable capacity for 1.5/2.0 Tonne (split type/window type ACs) of any make with super enameled copper winding wire of existing gauge including replacement of the motor bushes and shaft and testing on load for the entire satisfaction of Engineer-in-Charge.
Taking down existing fan blower motor of cooling unit and Material & labour for rewinding of fan blower motor of cooling unit of suitable capacity for 1.5/2.0 ton (split type/window type ACs) of any make with supper enameled copper winding wire of existing gauge including replacement of the shaft and bushes and testing on load for the entire satisfaction of Engineer-in-Charge.
Supply & fixing in repairs condensing fan motor single phase, AC 230 V, 50 Hz, for 1.5/2.0 Tonne capacity split type AC (for outdoor unit) of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs condensing fan motor single phase, AC 230 V, 50 Hz, for 1.5/2.0 Tonne capacity window type AC, of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs condensing fan DC motor for 1.5/2.0 Tonne capacity split type AC (for outdoor unit), of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs blowers suitable for outdoor unit of 1.5/2.0 Tonne Split type AC, of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs fan blades (ISI Marked) of suitable size for outdoor unit of 1.5/2.0 Tonne Split type AC complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs fan blades (ISI Marked) of suitable size for 1.5/2.0 Tonne Window type AC complete all as specified & directed by the Engineer-in-Charge.
Material & labour for repairing of PCB control card suitable for 1.5/2.0 Tonne capacity split /window type AC, single phase and making the PCB control card functional complete to the entire satisfaction of Engineer-in-Charge.
Material & labour for reparing of PCB control card suitable for 1.5/2.0 Tonne capacity Invertor type split/ window AC, single phase and making the PCB control card functional complete to the entire satisfaction of Engineer-in-Charge.
Supply & fixing in repairs PCB control card suitable for AC indoor unit 1.5/2.0 Tonne split AC, single phase of original make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs PCB control card suitable for DC indoor unit 1.5/2.0 Tonne inverter split/window AC, single phase of original make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs PCB control card suitable for outdoor unit 1.5/2.0 Tonne inverter split AC, single phase of original make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply only in replacement of Remote suitable for 1.5/2.0 Tonne capacity split AC of original make as per existing at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs capillary copper tube (ISI Marked) of suitable size for split /window type AC capacity 1.5/2.0 Tonne complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs condenser coil for split type AC 1.5/2.0 Tonne capacity of any make including charging of gas R-22/R407C complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs copper cooling coil for window type AC 1.5/2.0 Tonne capacity of any make including charging of gas R-22/R407C complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs water tray (ISI Marked) for Indoor unit of split AC of any capacity and make AC as approved by Engineer-in-Charge.
Supply & fixing in repairs of relay of split type AC of any make and any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs thermostat suitable for any make of Window type/Split type AC 1.5/2.0 Tonne capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs single pole contactor suitable for split type AC capacity 1.5/2.0 Tonne complete all as specified & directed by the Engineer-in-Charge.
Material & labour for finding out the leakage with the pressure test of the condenser or cooling coil of window type AC's/split type AC's of 1.5/2.0 Tonne capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering with and including charging the gas R-22/R-410A and testing the AC to the entire satisfaction of Engineer-in-Charge.
Supply, laying and commissioning in replacement of cable PVC sheathed cable with multistranded copper conductor of size 2.5 sqmm 3 core complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs copper tube (ISI Marked) of size ⅝” dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs copper tube (ISI Marked) of size ¼” dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
Material & labour in repairs fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size ⅝" dia for split type AC's any capacity complete all as specified & directed by the Engineer-in-Charge.
Material & labour in repairs fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size¼" dia for split type AC's any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs flexible drain pipe (PVC BRAIDED hose pipe) of size 15 mm dia, for split type AC any capacity and any make complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs air filter element suitable for split type AC 1.5/2.0 Ton capacity any make complete all as specified & directed by the Engineer-in-Charge.
Material & labour for fabrication of canopy stand for outdoor split type AC unit of mild steel angle iron 40mmx40 mm x 6 mm with mild steel plate of 1.6mm thick covering at top including cutting, made to shape, welding, with locking arrangement including painting of all steel surfaces with two coat of synthetic enamel paint over one coat of red oxide primer and fixing the same on PCC platform of suitable size including dismantling the old unserviceable rusted cracked canopy stand complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs wall mounting bracket stand suitable for 1.5/2.0 tonne capacity outdoor unit of split AC including necessary dash through bolt of suitable sizec omplete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs floor mounted bracket AC stand certified special coated super 50cm x 8 cm shelf bracket suitable for 1.5/2.0 ton outdoor unit capacity including necessary dash through bolt of suitable size complete all as specified & directed by the Engineer-in-Charge.
Material & labour for scraping and removing of old paint of MS sheet canopy and frame of condensing unit of split type AC unit and preparation of steel surfaces and applying two coat of synthetic enamel paint of smoke grey colour (first quality) over one coat of zinc chromate primer complete all as specified & directed by the Engineer-in-Charge. Note:- Painting shall be done with spray gun and compressor)
Material & labour in replacement for sub main wiring with two runs of PVC insulated unsheathed multi stranded copper conductor FRLS cable 4 Sqmm 1100 volt grade drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm,concealed in wall (including accessories like bends, tees, junction boxes, etc fixed in wall or ceiling etc.) including 2.5 sqmm PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 volt grade as earth wire including taking out / down the existing unserviceable sub main wiring with conduit complete all as specified and directed by the Engineer in Charge. Note :- Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length.
Supply & fixing in repairs sheet metal enclosure SPN with two pin and earth plug socket with & including 25 Amps MCB 'C' curve single pole 240 Volt AC complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB SP 06 to 32 Amp, ‘C’ curve type, 10 KA complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB SPN 40 to 63 Amp, ‘C’ curve type, 10 KA complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement 3 pin metal clad plug top capacity 15 Amp AC 240 Volts 50 Hz complete all as specified & directed by the Engineer-in-Charge.
Taking out of split AC/window AC any capacity including disconnecting from existing supply with proper sealing of gas pipes (pumpdown) to avoid leakage from the site and depositing to MES store yard (work shop) for major repair works complete all as specified & directed by the Engineer-in-Charge.
Fixing & commisioning only of split/window type AC capacity 1.5/2.0 Tonne (AC obtained from item No.50 above shall be reused) including testing after installation complete all as specified & directed by the Engineer-in-Charge. Note :- Copper tubing if required shall be measured & paid seprately.
Supply & fixing in replacement Display card of Indoor unit of Split AC capacity 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs L & key valve (ISI Marked) of size 5/8" for condenser unit split type AC 1.5/2.0 Tonne , including proper leak test check shall be carried after replacement of valve complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs L & key valve (ISI Marked) of size 1/4" for condenser unit split type AC 1.5/2.0 Ton , including proper leak test check shall be carried after replacement of valve complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs flair nut size 5/8" and 1/2"dia for split type AC of any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs flair nut size 3/8" and 1/4" dia for split type AC of any capacity complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs dead nut size 1/4 '' dia for any capacity of split type AC complete all as specified & directed by the Engineer-in-Charge.
Material & labour for filling of Refrigerant Gas R-22 complete all as specified & directed by the Engineer-in-Charge.
Material & labour for filling of Refrigerant Gas R-410A/R-32 complete all as specified & directed by the Engineer-in-Charge.
Supply & Fixing in repairs AC motor suitable for Indoor unit blower of split type AC 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Supply & Fixing in repairs DC motor suitable for Indoor unit blower of split type AC 1.5/2.0 Tonne of original make as per existing in the machine at site complete all as specified & directed by the Engineer-in-Charge.
Material & labour for sealing the bore holes of walls with expandable polyurethane foam complete all as specified & directed by the Engineer-in-Charge. Note :- Only existing Holes in walls to be sealed.
Supply & fixing in replacement Voltage Stabilizer of capacity 03 KVA, for automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5 % complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in replacement Voltage Stabilizer of capacity 05 KVA, for automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5 % complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs MCB DB SPN 08 ways, double door concealed in wall IP 54 protection including making good the disturbed surfaces complete all as specified & directed by the Engineer-in-Charge.
Supply & fixing in repairs sheet metal enclosure vertical MCB DB TPN 04 ways, IP 43, with 200 amps rated bus bar 415 Volts suitable for and including 63 Amps TPN MCCB 36 KA as incomer, double door with magnetic locking system complete all as specified & directed by the Engineer-in-Charge.
Shri Electrical Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .