| 1 | 1₹1.3 CrAccepted-Finance VILLAGE AND POST OFFICE LUJ TEHSIL PANGI DISTRICT CHAMBA | ₹1.3 Cr | 1 | Accepted-Finance Lowest One |
| 2 | 2₹1.4 Cr+₹10.7 L (8.42%)Rejected-Finance VILL SAKRAH PO CHAMBI TEHSIL SUNDERNAGAR DISTT MANDI HP | SUNDERNAGAR | MANDI | HIMACHAL PRADESH | ₹1.4 Cr+₹10.7 L (8.42%) | 2 | Rejected-Finance Other than lowest |
| 3 | 3₹1.4 Cr+₹16.5 L (13.1%)Rejected-Finance | ₹1.4 Cr+₹16.5 L (13.1%) | 3 | Rejected-Finance Other than lowest |
| 4 | 4₹1.4 Cr+₹17.7 L (13.9%)Rejected-Finance VPO TEHSIL JAWALI DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | ₹1.4 Cr+₹17.7 L (13.9%) | 4 | Rejected-Finance Other than lowest |
| 5 | 5₹1.5 Cr+₹20.8 L (16.4%)Rejected-Finance | ₹1.5 Cr+₹20.8 L (16.4%) | 5 | Rejected-Finance Other than lowest |
Tender Value
₹1.5 Cr
EMD Value
₹1.8 L
Closing Date
1 Feb 2024, 5:00 pmClosed
Executive Engineer JS Division Karsog
Executive Engineer JS Division Karsog
Providing LIS to Upper Shakra in Tehsil Karsog Site Development Desliting Tank RCC Circular Storage Tank Pump House Pumping Machinery Rising Main
2024_HPIPH_84525_1
KSG_MDI10_764
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
Tattapani
Providing LIS to Upper Shakra in Tehsil Karsog Site Development Desliting Tank RCC Circular Storage Tank Pump House Pumping Machinery Rising Main
8 documents required · 8 mandatory
₹1,500
Yes
₹1.8 L
Yes
25 Jun 2024
24 Jan 2024
2 Feb 2024
24 Jan 2024
1 Feb 2024
24 Jan 2024
24 Jan 2024 - 1 Feb 2024
Amount
Cutting in all kinds of soil such as kankar, moorum, shingle boulders decomposed of soft rock or any such mixed in other variety of soil or rocks, including filling in embankments where necessary including ramming and watering etc. stacking of serviceable materials at the place specified by the Engineer-in-Charge including all leads and lifts wherever or for what purpose required.
Excavation in foundation, trenches ( for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of such deposoited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration unmetalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-Charge.
Providing and laying cement concrete 1:4:8 (1 cement:4sand:8 graded crushed stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth in all leads and lifts and to the enitre satisfaction of Engineer-in- charge.
Providing and laying cement concrete 1:5:10 (1 cement : 5 Sand :10 graded stone aggregate 40mm nominal size) and curing complete excluding the cost of form work in: Foundation and plinth. complete with in all lead & lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying cement concrete 1:3:6(1cement: 3sand: 6 graded stone agg.40mm nominal size) and curing complete excluding cost of centering and shuttering complete in all respect within all lead and lifts as per the direction of Engineer-in-Charge. a) Foundation and plinth.
Providing and laying cement concrete 1:6:12(1cement: 6sand: 12 graded stone agg.40mm nominal size) and curing complete excluding cost of centering and shuttering including all leads and lifts. a) Foundation and plinth
P/L cement conc. 1:2:4(1 cement:2 sand:4 graded stone agg. 20mm nominal size) and curing complete excluding cosot of form work and reinforcement of RCC work in all leads and lifts as per direction and to the entire satisfaction of the Engineer-in-charge.
Suspended floor, roof, landing, balconies, shelves and thwir supports balconies, beams girder bressumers and cantilevers upto floor two level.
Foundation footing , basis of columns and the like and mass concrete.
Providing and laying cement concrete 1:1 ½ :3(1cement:1 ½ sand:3graded stone aggregate of 20mm nominal size)and curing complete excluding cost of form work and reinforcement for reinforced concrete work complete in all respect within all lead and lifts as per the direction of Engineer-in-Charge.
Foundation footing , basis of columns and the like and mass concrete.
Walls (any thickness) but not less that 0.10 Mtrs. thick including attached pilasters buttresses plinth and string course from top of foundation upto floor two levels.
Column,s pillars posts and struts upto floor two level.
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing & Laying mild /tor steel reinforcement for RCC. work including bending, binding and placing in position complete up to floor two level complete in all respect within all lead and lifts as per the direction of Engineer-in-Charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4mtrs.and removal of the same for in situ reinforced concrete and plain concrete work complete in all respect within all lead and lifts as per the direction of Engineer-in-Charge.
Vertical surfaces such as walls (any thickness)portions and the like including attached pilaster buttresses plinth and string course and the like
Flat surface such as soffits and suspended floors, roofs, landings and the like: Floors etc. up to 200mm in thickness within all leads and lifts
Foundation,footing basis of columns & the like and mass concrete.
Column,s pillars posts and struts upto floor two level.
Beam/cantilevers,girders & lintels,side & soffits, of beams, haunching, cantilevers, bressumers 1.00 mtrs In depth in all height from floor
Provision for C/O control room equiped wit lifting (electrical operated chain pully ) of M.S Pipe & Pump machinery etc. i/c up & down arrangement of suction etc. acc. To water level in the Satluz river .it also covers side railling of M.S Pipe
Laying Jointing of G.I Pipe (;light grade) tube fitting in trenches I/c earth work complete in all respect within all lead and lifts as per the direction of Engineer-in-Charge. for Scour pipe, Out let pipe & inlet pipe (LR).
G.I pipe 150 mm
G.I pipe 125 mm
G.I pipe 100 mm
Providing & fixing CI Sluice valve (with hand wheel) as per IS : 780-1984 class-I upto 300mm dia.(i/c brass spindle & as per 2906-1984class-II for dia. 300 mm) in outlet, Scour and inlet pipe of G.I With M.S flange T-5 i/c welding and fix the sluice valve with flanged pipe complete with bolts nuts,rubber insertion etc.,complete in all respect within all lead and lifts as per the direction of Engineer-in-Charge. for Scour pipe, Out let pipe & inlet pipe make JSV approved
Steel work welded in built up sections,trusses & framed work i/c cutting,hoisting & fixing in position & applying a priming coat of red paint :-In grating, framed ,guards,bars,ladders, railing,brackets & similar works with in all leads and lifts as per the entire satisfaction & direction of the Engineer Incharge
Constructing chamber for sluice valve, with CI surface box 100 mm top dia.,160 mm bottom dia. & 180 mm deep(inside) with chained lid RCC top 1:2:4 mix (1 cement :2 sand :4 grad-ed stone aggregate 20 mm nominal size 100mm thick foundation concrete 1:5:10 mix (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) & inside plastering with cement mortor 1 :3 (1 cement : 3 sand) finish-ed with a floating coat of neat cement i/c curing complete.
Random rubble masonary/Polygonal rubble masonary (coursed or brought to courses with hard stones of approved quality in foundation and plinth including levelling up with cement concrete 1:6:12 in cement mortar 1:6 ( 1 cement : 6 sand)as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.
Brick work using comman burnt clay building bricks in foundation above plinth level upto floor two level with C.M 1:6 ( 1 cement :6 Sand ) with in all leads and lifts as per direction & satisfaction of Engineer -in-charge. (2nd class bricks).
Half Brick work with conventional using comman burnt clay building bricks in super structure up to floor two level 2nd class brick in cement motor 1:4 (1cement:4 sand) with in all leads and lifts as per the entire satisfaction & direction of the Engineer in charge.
Pointing on Brick work with cement mortor 1:3 (1cement : 3 Sand) complete with in all lead & lifts and to the entire satisfaction of the Engineer-in-Charge.
Providing and laying brick tiles over mumty roofs grouted with cement mortar 1:3 over a 12mm layer of cement mortar 1:3 and finished needly within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing panelled glazed or panelled and glazed shutters for doors, windows and clerestory windows i/c bright 2nd class deodar wood 40mm thick including entire carriage of material as per satisfaction of E-in-charge.
Providing and fixing pressed steel door, frames, manufactured from comercial mild steel sheet of 1.25 mm thickness including hinges jump block Jamb, beed, and if required angle threshold of mil steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or regidly fixed together by machanical means adjustable lugs with split and tails to each Jamb i/c steel but things 2.5mm thick with guards lock strike plate and shock as specified and applying a coat of applying steel primer after pretreatment of the surfaces directed by the Engineer-in-charge
6 mm cement plaster to ceiling in CM 1:3 ( 1Cement :3 Sand) as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.
15 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cement mortar 1:6 (1cement:6sand) with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge.
20 mm thick cement plaster on rough sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cement mortar 1:3(1cement:3sand) with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge.
Providing & fixing M.S. grills of required pattern in wooden frame of window etc.with M.S. flats, square or round barswith round headedbolts and nuts by screws plain grills. as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.
Providing and fixing wire gause shutters using galvanised MS wire gause of IS gause designation 85 G with wire diameter 0.56mm for doors, windows, clerestorey windows I/c bright finished black enamelled iron hinges with necessary secrews 30 mm thick 2nd class deodar wood with in all leads and lifts as per the entire satisfaction & direction of the Engineer - in - Charge. 2nd class deodar wood.
Boulder filling behind the R/wall/under channel bed including all leads and lifts
Providing plinth protection 50 mm thick in cement concrete 1:3:6 (1 cement: 3 sand: 6 graded stone aggregate 20 mm nominal size as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.
Constructing course rubble hammer dessed "U" shape open surface drain with side wall 15x22 cm in cement mortor 1:6 (1cement : 6 sand) and inside plastering with cement plaster 1:3 (1cement : 3 sand) including earth work and laayng 10 cm cement concrete in 1:5:10 (1 cement :5 sand : 10 graded stone aggregate 40 mm nonminal size) and 7.5 cm cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) and finished with a floating coat of neat cement complete as per standard design.
White washing with lime on undecorated wall surfaces(two coats) to give an even shade I/c thoroughly brooming the surface to remove all dust dirt & other foreign matter as per direction & to the entire satisfaction of Engineer-in- Charge upto all lead & lifts.
Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on undecorated wall surfaces to give an even shade sand papered smooth.as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.
Finishing wall with water proofing cement paint of approved brand and manufacture and of rerquired shade on undecorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials.
Applying priming coat on new wood and wood based surfaces after and including preparing the surface by thoroughly cleaning oil,greese,dirt and other foreign matters, sand papering and knotting.Ready mixed paint brushing wood primer pink. as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.
Painting two coats(excluding coat) on new wood and wood based surface with enamel paint to give an even shade including cleaning the surface of dirt,dust and other foreign matter,sand papering & stoping with animal paint other then white and as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.
Precast terrazo tiles 20m thick (with marble chipsof specified shadeand of specified laid in floor treads of steps and landingon bed on10mm thick cement plaster 1:6 (1cement6sand) jointed withneat cement slurry mixed with pigment to match the shade of tiles. selvary grey
Providing and fixing anodised MS sliding door bolts with bolts and nuts screws etc. complete and as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts. 300x16 mm.
Providing and fixing anodised MS tower bolts ( barrel type) with screws etc. complete and as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts
Providing and fixing anodised MS Handle transparent or died to required shade with screws . complete and as per direction & satisfaction of the Engineer- in- charge upto all lead & lifts.100 mm.
Providing , laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding ) and testing of MSERW pipe X-42 of following dia meters confirming to BIS 3183-2007, steel grade -A (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards and the damaged portion of the pipes and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately).
1200 mm dia MSERW pipe X-42 thickness 4.00mm from RD 0 to 1000 = 1000 rmt. @ 95% butt welding = 950 rmts.
Providing Laying in trenches IS marked MSERW pipe X-42 of following diameters conforming to BIS 3183-2007 of following grade and having wall thickness as specified below with plain end capable of with standing required test presure in random length of 4 to 7 mtr, including specials, short pieces bends, reducers, tees etc. made from parent tube with providing and welding of MS flanges detailed as below. The MS flanges shall confirm to BIS 6392-1971 ( with latest up to date amendments) duly welded in two layers ( two inner and two outer) with pipes at both ends as per relevant BIS standards along with nuts and bolts of required sizes 3mm thick compressed asbestos fiber/synthetic rubber gaskets confirming to relevant BIS standared. The laying of pipe will include all operation such as cutting welding jointing providing and fixing of MS flanges fabrication of bends tees etc. including lowering and laying in excavated trenches to ensure required level including flushing cleaning and hydralic testing complete in all respects to the satisfaction of the Engineer inCharge. The fabricated bends shall have three or four cuts having its radius not less than five time the dia of pipe. The pipe shall be factory galvanized ( zinc coating both inside and outside) as per relevant IS standareds and the damaged portion of the pipe and specials made form the parent tube shall be provided anticorrosive treatment by applying two coats of antocorrosive bituminous paint over a priming coat as per AWWA Specification C-203-1978. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The rates also includes entire carrriage of matrial flushing cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts.(5% of Lenght of Rising Main has been taken for Flanged)
200 mm dia MSERW pipe X-42 thickness 4.00mm Flange Table-28 from RD 0 to 600 = 600 rmt. @ 5% flanged joint = 30 rmts.
200 mm dia MSERW pipe X-42 thickness 4.00mm Flange Table-17 from RD 600 to 1000 = 400 rmt. @ 5% flanged joint = 20 rmts.
200 mm dia MSERW pipe X-42 thickness 4.00mm Flange Table- 5 from RD 0 to 100 for (submersible stage)
Submersible Pump Set:- Supply of submersible Raw Water pump set confirming to ISO 9906 suitable to handle turbidity up to 60 PPM of KSB/ Kirloskar /Sabar/ Johnston/Crompton/ Kalama make instead of clear water pump conforming to BIS:8034 for 600 PPM or latest suitable for lifting Water ( latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrel case electric induction motor of same make as (manfacture standared) conforming to BIS: 9283-1979 ( latest with upto date ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrust bearig plate to with take up expansion of water with the heating of motor including water level guard errection clamps, manfacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given as below:- Discharege (Q) 26.16 LPS for each pump, Total Dynamic head 12.44 meter, (a) LWL in Sump well (h) 652.50 meter, Shaft level 652.00 meter, level at discharge point 663.00 meter, sunction lift +ve, discharge head 11 meter, static head 11 meter, Rising main:- Length 100 meter, dia 200mm, Pumping hours 20 hours, Altitude of installation above MSL 650 Meter Characterstics of water turbidity upto 600 PPM, Temperature 25 degree centigrade.
Suppply , Installation , Testing and Commissioning of Star Delta Stater Panel for Submersible pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mouted and front opening door type with copper insulated wiring suitable to operate 1Nos. pumps(1working) each of the rating 10HP through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/ OFF & TRIP indicators. Make: JSV approval
Star, Delta and Mains Power Contactors of required ratings as per type-2 co-ordination for 10HP starter
Voltage Protection device to protect panel from over voltage and under voltage
Single phasing and phase reversal protection device top safeguard system from single phasing and phase reversal of the supply voltage
Multi function meter indicating different parameters like current, Voltage, KWH , PF , THD etc with RS 485 communication Make JSV approved
Main incomer MCCB/MCB of suitable capacity of L&T/ Schnieder/ABB make on the feeder for pumping set confirming to BIS 2516-1985 (Latest edition) JSV approved
Individual Starter incomer MCCB/MCB of suitable capacity of L&T/ Schieder /ABB make on the feeder for pumping set confirming to BIS 2516-1985 (Latest editiion) JSV approved
Three phase indicating lamps complete with toggled switches for individual motors confirming to BIS 3452 (Part I & II ) latest with upto date ammendments.
LED On/Off & Trip indicator and push buttons, Control and power wiring, power capacitor, cooling fan 230 VAC , Control terminal, Bus Bar , i.e. Bolt, insulator, etc
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.
Control Transformer to provide a stable control voltage to safegaurd the control circuit of all the components from the voltage surges and spikes JSV approved
Providing double flanged cast steel sluice valve, ASA-150 of Leader/BHEL/Kirlosker/Kilburn / GLEd/ Fourses make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendment
Providing double flanged cast steel reflux valves class, ASA-150 of Leader/BHEL/Kirlosker/Kilburn / GLEd/ Fourses make for rising main and capable of withstanding normal seat pressure as per BIS standards with upto date amnmendment
Providing 100mm dia circular dial analog pressure gauge of suitable of Fiebig/Bourden/PREGA/precision make complete with all accessories such as stop cock, copper tubing etc. as per IS:3624-1987 with upto date amnmendment
Providing discharge meterof standard make to be fixed on the rising main in pump house as per the directions of the Engineer in Charge as per IS:2373:1981 with upto date ammendments.
Installation of all the items apparing as per the schematic drwaing.
Providing and laying copper PVC insulated armoured power cable (One cable carrying all the three phases) of suitable size and capacity to motor and all other electrical equipments as per IS:1554(P-I) 1988 or latest with upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes, solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.
(a) Motor side (From switch to starter and starter to Motor)
(b) Supply side (From Meter of HPSEB to bus bar and switch)
PLC (Programmable logic controller) with appropriate digital and analog inputs and output
Electronic relay card 8 channel
SMPS 4.5 Amps to energise PLC system
HMI (Human Machine Interface) 7'' display for Monitoring and controlling
Control MCB for Automation system
Level Sensor to indicate the water level of tank remotely
Shielded Data Cable for Communication of Level Sensor with PLC
Centrifugal Pump Set:- Supply of horizontal spindle horizontal radial casing/ and suctions(back pull out arrangments) Single/ double / multistage centrifugal pumps or combination of pumps in series/parellel of KSB/Mathur & Platt/Jyoti/ Kriloskar/ BE / Maxflow/ Beaconweir sabar make conforming to BIS 5659-1970) pump (latest with upto to date amendments, read with BIS :9137-1978 (latest edition) suitable for lifting water of under mentioned characteristics with bronze/ suitable alloy,priming funnels, casing ring and shaft motor of bronze, shaft of steel grade ASA-410 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set ) to coupling of electric induction motor/motor of standard make such as Kirloskar / NGEF / Cromption / Siemen/ Jyoti/ BHEL / GEC / ABB confirming to BIS 325-1978) read as BIS 900-1972 and IS: 12615:2011 with IE-2 specification (latest upto date ammendments) it should include the cost of bearings, nuts & bolts , painting etc. and shall be and suitable for operation on the data given as below:- Discharege (Q) 13.08 LPS for each pump, Total Dynamic head 275.8 meter, (a) LWL in Sump well (h) 662 meter, Shaft level 661.50 meter, level at discharge point 930 meter, sunction lift +ve, discharge head 268.50 meter, static head 268.50meter, Rising main:- Length 100 meter, dia 200mm, Pumping hours 20 hours, Altitude of installation above MSL 660 Meter Characterstics of water turbidity clear water with turbidity upto 600 PPM,
Supply, installation, Testing and Commissioning of Energy saving variable Frequency starter panel for centrifugal pump made out of 16 Gauge sheet, power coated dust and vermin proof , wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pumps (2 working) each of the rating 100HP. Starter should be capable enough to handle the following faults like Short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators, Power Quality Monitoring & Controlling Relay at the incomer Feeder, should be fitted with surge suppressor Device suitable to protect against class-1 & 2 Surges exhaust fan, DC reacter and EMC Filter with C3C casting Make: JSV Approved
Energy Saving Variable Frequency Starter of 100HP Heavy Duty for smooth start and smooth stop of pumpd and for the energy conservation in the system. It should be capable to monitor & control the frequency of pump through out the operation and to maintain the power factor of the system within acceptable limits. it should be able to withstand ambient temperature upto 50 Degrees celcius without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. JSV approved
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc. with RS 485 communication Make:- JSV Approved
Main incomer MCCB of Suitable capacity of L&T / Schnieder / ABB / Siemens make on the coming feeder for pumping set confirming to BIS 2516-1985 (latest edition)
LED Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 (Part I & II ) latest with upto date ammendments.
LED On/ Off & Trip indicator and push buttons, Control and power wiring, Power capacitor, cooling fan 230 VAC, control terminal, Bus bar, i.e. Bolt, insulator, etc.
Input Choke of required HP for Energy saving variable frequency starter which should be installed at the input of energy saving variable frequency starter, so that there should be proper protection in case of any voltage surge and distortions.
Control Transformer Make: JSV Approved
Power and control wiring and busbar
Installation, commissioning and software Development
Surge supressor device with isolating MCCB to eliminate the power surges due to lightening and system surges.
Power Quality monitoring & controling relay with control contactor to safegaurd the Electronic & Electric elements.
Independent control panel with switch fuse unit and fuses of suitable Amperage to eliminate the KITKAT fuses of HPSEB Make: JSV Approved
Providing double flanged CI sluice valve PN-1 of Leader/ BHEL/ Kirlosker/ GLED / Kilburn/ Fourses / Kartar make and equal to dia of suction pipe and capable of withstanding the normal seat pressure as per IS: 780:1984 with upto date ammendments)
Providing double flanged Cast steel sluice valve , ASA-300 of Leader/ KSB/ Kirlosker make and one step higher then delivery line of pump capable of withstanding the normal seat pressure as per BIS Standards with upto date ammendments)
Providing double flanged Cast steel reflux valve class , ASA-300 of Leader/ BHEL/ Kirlosker/ GLED / Kilburn/ Fourses make for rising main and capable of withstanding the normal seat pressure as per BIS Standards with upto date ammendments)
Providing souble flanged cast steel reflux valves class, ASA-300 of Leader/ BHEL/ Kirlosker/ Kartar/ Kilbrun / Gled/ Fourses make for rising main and caable of withstanding normal seat pressure as per BIS standards with upto date ammendments.
Providing 100mm dia circular dial analog presure gauge of suitable range of Fiebig/ Bourden/ PREGA/ precision make complete with all accessories such as stop cock, copper tubing etc. as per IS:3624-1987 with upto ate ammendments.
Providing discharge meter of sandard make to be fixed on the rising main in pump hose as per the directions of the Engineer in charge as per Is :23731981 with upto date ammedments.
Installation of all the items apparinmg as per the schematic drawing.
providing and fixing double flanged MS/Gi piping work (Layout to be approved by the Engineer in in Charge0 for suction deloivery pipes suitable to pump (s) offered and common header as per the R/Main respectively complete with all specials such as bends, tees, reducers. Increasers with cimpanions flanges matching with the relevant specufication of the acccessories including rubber/ asbestos gasket of minimum 3mm thckness as per IS:27:12:1979 and required numer of nuts and bolts as per Is :1364:1983, The Pipes fittings and joints shall be as per relevant IS code & to withstand 1.5 times total head stipulated under item No. 12. The size of the various comoponants to be as under.
a) Suction pipe: One dia higher then the suction of pump offerd and suitablke to keep the velocity of flow from 1 to 1.5 M/second in the suction pipe.
b) Delivery pipe: One dia higher then delivery of the pump offered and suitable to keep the velocity of flow from 1.5 to 2M/ second in the delivery pipe.
c) Common header: One dia higher then delivry of pump will extend upto 5 meters from the outer wall of the pump house in the derection to be jointed.
Providing and laying copper PVC insulated armoured power cale ( One cable carrying all the three phases ) of suitable size and capacity to motors and oil other electrical equipments as per IS: 1554 (P-1) 1988 orlatest with up to date ammendments of sienes/ GLOSTER/IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such thinbles, flexsible pipes, solders, nuts and bolts cable glandsetc, laid in pipes or trenches under floor.
a) Motor side ( Grom switch to starter and starter to motor)
(b) Supply side (From Meter of HPSEB to bus and bar and switch.
Providing and fixing double loop earting with GI plate 600mmX3mm thick electrode complete with material such thimbles nuts and charcoal and commo salt, 25mmX5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pitrs etc, complete in all respect.
PLC ( Programmable logic controller) with appropriate digital and analog inputs and outputs to give automatic command to star Delta Starter Panel/ Energy Saving Varaable Frequencyn Starter Panel : JSV Approved.
Electronic relay card 8 channel
SMPS 4.5 Amps to energies PLC system
HMI ( Human Maching Interface) 7" display for Monitoring and Controlling of Centrfugal pumps Make : JSV Approved/ Bechoff Auitomation / Rockwell
Control MCB for Automation System
Level Sensor to indicate the water level of tank remotely
Shielded Data Cable for communication of Level Semnspor with PLC
KUSHAL SINGH RAGHAV
R.K.Manhotra
Mohit Kaushal
SANJEEV KUMAR SHARMA
Anurag Deep
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .