Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.1 L+₹4.5 L (25.6%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹22.5 L+₹4.9 L (27.7%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹23.3 L+₹5.7 L (32.1%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹29.8 L+₹12.2 L (69.3%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹85,000
Closing Date
17 Oct 2020, 6:00 pmClosed
HQ CWE Kota
HQ CWE Kota Dadwara Military Station Kota Rajasthan 324002
CWE KOTA/ALW-30 OF 2020-21 SPECIAL REPAIR TO CONVERSION OF LT OH LINE TO LT UG CABLE AT ITARANA ALWAR
2020_MES_371101_2
CWE KOTA/ALW-30 OF 2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
ALWAR
For Enlisted Contractors Class D Category b i and for unenlisted contractors meeting enlistment criteria for required Class and Category
8 documents required · 8 mandatory
₹500
GE Alwar
₹85,000
Yes
10 Nov 2020
8 Oct 2020
19 Oct 2020
8 Oct 2020
17 Oct 2020
12 Oct 2020
8 Oct 2020 - 12 Oct 2020
Amount
Taking down old unserserviceable ACSR aluminium Conductor of any size from Poles and removing from site complete all as specified and directed.
Taking down old unserviceable cross -arms/bracings supports/clamps/nut bolts/back plate and Angle section etc from Pole any size/height, complete all as specified and directed.
Taking down old unserserviceable GI Earth wire/Guard wire etc. of any size from LT Poles and removing from site complete all as specified and directed.
Dismantling and taking down of old unserviceable pin type/ shackle type insulators and from any height of electric pole, complete all as specified and directed.
Demolition of plain cement concrete of any description and in any position otherwise specifically provided for complete all as specified and directed.
Dismantling and taking old unserviceable stay assembly from LT poles and removing from site, complete all as specified and directed.
Dismantling and taking old unserviceable prestressed cement cocnrete LT poles, complete all as specified and directed.
Dismantling and taking down of old steel poles/ struts for re-use complete all as specified and directed.
Dismantling and taking down street light fitting with bracket from the PCC pole and Re-fixing the same on steel tubular pole including 2 Nos flat iron clamp 50x6mm with bolts, nuts and washer complete all as specified and directed.
Excavation in trenches n exc. 1.5 mtr width n. exc 1.5 mtr in depth for laying of cables & foundation of poles stay assembly and getting out soft/loose, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose soil in trenches after cables have been laid and tested,poles, stays, struts have been erected and tested complete all as specified and directed.
Removing excavated surplus material (Soils) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection, complete, all as specified & directed.
M & L for sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
Supply and fixing GI pipe 50 mm bore light grade , ISI marked, including all fittings and laid in trecnhes/ under road/ drains, fixed to poles/ walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable GI tubes, complete all as specified and directed.
Fixing/Laying only/jointing/testing & comissioning LT UG cable of LT under ground cable 1100 volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles complete all as specified and directed for following size cables :-
3.5 core 185 Sqmm
3.5 core 120 Sqmm
3.5 core 95 Sqmm
3.5 core 70 Sqmm
3.5 core 50 Sqmm
4 core 16 Sqmm
2 core 25 Sqmm
2 core 16 Sqmm NOTE :- (a) Excavation & earth work for laying cable shall be measured and paid for seprately under respective items of this BOQ. (b) GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the schedule (c) Road cutting involved during excavation for laying of cables etc shall be made good as per existing road. Nothing extra shall be admissible on this account. Quoted rates of the item shall be inclusive of the above provisions.
Supply & errecting cable path indicators for LT cable made of CI plate fixed on MS angle iron size 25x25x5mm and 60 cm long and fixing in ground 30 cm below ground level in PCC 1:3:6 ype B-1 using 40mm grade stone aggregate of size 30x30x30cm, cable path indiciators shall be provided at distance of every 30 metres and at cable joints and turning of all cables and incorporated LT 1100 volts on it, including PCC & earth work complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20 mm graded aggregate) as in pedestal of poles, copings etc including providing necessary form work for fair finished exposed concrete surfaces, completed all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20 mm graded aggregate) as in foundation of stay assembly & poles and similar works, completed all as specified and directed. Note:- Volume of pole/strut embedded in concrete shall be deducted for the purpose of payment.
Supply and fix of automatic street light switch using infrared sensor based three phase nature switch for automatic switching of street lights, nature switch operation should be based on netural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF>10 Lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs. 3 Nos contactors, each of 25 Amp and incoming-outgoing MCBs single pole (3 Nos each) rating 25 Amp and Auto-Manual (sensor by pass) seelection option should be enclosed in a pole/ wall mountable enclosure made of Ruse proof Electric shock proof. Termite proof and FR grade SMC junction box conforming to IP 54 Model : SWADEEP-02EC complete all as specified and directed.
BLANK
S & F for pole mounted junction box made out of one piece moulded SMC IP65 protection having aluminium bus bars 100 Amps single phase and neutral with one No. MCB SPN 6 Amp for street light, cable entry from bottom, maintenance free size 300x200x100mm fixing on pole with MS flat 25x3mm clamp inclduing nut bolts front openable complete all as specified and directed.
S & F for pole mounted junction box made out of one piece moulded SMC IP65 protection having aluminium bus bars 100 Amps three phase and neutral with one No. MCB SPN 6 Amp for street light, cable entry from bottom, maintenance free size 300x200x100mm fixing on pole with MS flat 25x3mm clamp inclduing nut bolts front openable complete all as specified and directed.
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT Panel Board, cubicle type, suitable for 415 volts, 3 Phase, 4 wire, 50 Hz, AC supply system and tested at CPRI, having bus bar chember with insulated Aluminium bus bar four wire system, colour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, the panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but no less than 2.5 sqmm) including grouting of panel 60 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6mm, welded on all the four corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm complete all as specified and directed. The scope of work includes the following :- (a) INCOMING : - (i) MCCB four Pole 250 Amps, 25 KA - 01 No (ii) Aluminium bus bar 400 Amps with insulator - 04 Nos (iii) Instrument control fuses and indication lamp - 01 set. (b) OUTGOING :- (i) Thermal magnetic MCCB 3 pole, 250 Amps, 25 KA - 01 No. (ii) Thermal magnetic MCCB 3 pole, 125 Amps, 25 KA - 01 No.
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT Panel Board, cubicle type, suitable for 415 volts, 3 Phase, 4 wire, 50 Hz, AC supply system and tested at CPRI, having bus bar chember with insulated Aluminium bus bar four wire system, coour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, the panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but no less than 2.5 sqmm) including grouting of panel 60 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6mm, welded on all the four corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm complete all as specified and directed. The scope of work includes the following :- (a) INCOMING : - (i) MCCB four Pole 250 Amps, 25 KA - 01 No (ii) Aluminium bus bar 200 Amps with insulator - 04 Nos (iii) Instrument control fuses and indication lamp - 01 set. (b) OUTGOING :- (i) Thermal magnetic MCCB 3 pole, 200 Amps, 25 KA - 01 No. (ii) Thermal magnetic MCCB 3 pole, 100 Amps, 25 KA - 01 No.
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT Panel Board, cubicle type, suitable for 415 volts, 3 Phase, 4 wire, 50 Hz, AC supply system and tested at CPRI, having bus bar chember with insulated Aluminium bus bar four wire system, coour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, the panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but no less than 2.5 sqmm) including grouting of panel 60 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6mm, welded on all the four corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm complete all as specified and directed. The scope of work includes the following :- (a) INCOMING : - (i) MCCB four Pole 100 Amps, 25 KA - 01 No (ii) Aluminium bus bar 200 Amps with insulator - 04 Nos (iii) Instrument control fuses and indication lamp - 01 set. (b) OUTGOING :- (i) Thermal magnetic MCB TPN, 63 Amps, 25 KA - 02 Nos.
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT Panel Board, cubicle type, suitable for 415 volts, 3 Phase, 4 wire, 50 Hz, AC supply system and tested at CPRI, having bus bar chember with insulated Aluminium bus bar four wire system, coour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, the panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but no less than 2.5 sqmm) including grouting of panel 60 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6mm, welded on all the four corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm complete all as specified and directed. The scope of work includes the following :- (a) INCOMING : - (i) MCCB four Pole 100 Amps, 25 KA - 01 No (II) Aluminium bus bar 200 Amps with insulator - 04 Nos (iii) Instrument control fuses and indication lamp - 01 set. (b) OUTGOING :- (i) Thermal magnetic MCB TPN, 63 Amps, 25 KA - 04 Nos.
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT Panel Board, cubicle type, suitable for 415 volts, 3 Phase, 4 wire, 50 Hz, AC supply system and tested at CPRI, having bus bar chember with insulated Aluminium bus bar four wire system, coour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, the panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but no less than 2.5 sqmm) including grouting of panel 60 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6mm, welded on all the four corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm complete all as specified and directed. The scope of work includes the following :- (a) INCOMING : - (i) MCCB four Pole 100 Amps, 25 KA - 01 No (ii) Aluminium bus bar 200 Amps with insulator - 04 Nos (iii) Instrument control fuses and indication lamp - 01 set. (b) OUTGOING :- (i) Thermal magnetic MCB TPN, 63 Amps, 10 KA - 04 Nos (SPace for one No MCB).
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT Panel Board, cubicle type, suitable for 415 volts, 3 Phase, 4 wire, 50 Hz, AC supply system and tested at CPRI, having bus bar chember with insulated Aluminium bus bar four wire system, coour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, the panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but no less than 2.5 sqmm) including grouting of panel 60 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6mm, welded on all the four corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm complete all as specified and directed. The scope of work includes the following :- (a) INCOMING : - (i) Thermal magnetic MCCB 4 pole, 200 Amps, 25 KA - 01 no. (ii) Aluminium bus bar 400 Amps with insulator - 04 Nos. (iii) Instrument control fuses and indication lamp - one No. (b) OUTGOING :- (i) Thermal magnetic MCCB 3 pole, 160 Amps, 25 KA - 01 No. (ii) Thermal magnetic MCCB 3 pole, 63 Amps, 25 KA - 01 No.
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT Panel Board, cubicle type, suitable for 415 volts, 3 Phase, 4 wire, 50 Hz, AC supply system and tested at CPRI, having bus bar chember with insulated Aluminium bus bar four wire system, coour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, the panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but no less than 2.5 sqmm) including grouting of panel 60 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6mm, welded on all the four corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm complete all as specified and directed. The scope of work includes the following :- (a) INCOMING : - (i) Thermal magnetic MCCB 4 pole, 160 Amps, 25 KA - 01 no. (ii) Aluminium bus bar 200 Amps with insulator - 04 Nos. (iii) Instrument control fuses and indication lamp - one No. (b) OUTGOING :- (i) Thermal magnetic MCCB 3 pole, 160 Amps, 25 KA - 01 No. (ii) MCB DP, 63 Amps, 10 KA - 02 No + (Space for one No MCB)
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT Panel Board, cubicle type, suitable for 415 volts, 3 Phase, 4 wire, 50 Hz, AC supply system and tested at CPRI, having bus bar chember with insulated Aluminium bus bar four wire system, coour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, the panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but no less than 2.5 sqmm) including grouting of panel 60 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6mm, welded on all the four corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm complete all as specified and directed. The scope of work includes the following :- (a) INCOMING : - (i) Thermal magnetic MCCB 4 pole, 160 Amps, 25 KA - 01 no. (ii) Aluminium bus bar 200 Amps with insulator - 04 Nos. (iii) Instrument control fuses and indication lamp - one No. (b) OUTGOING :- (i) Thermal magnetic MCCB 3 pole, 63 Amps, 25 KA - 01 No. (ii) Thermal magnetic MCCB 3 pole, 125 Amps, 25 KA - 01 No.
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT Panel Board, cubicle type, suitable for 415 volts, 3 Phase, 4 wire, 50 Hz, AC supply system and tested at CPRI, having bus bar chember with insulated Aluminium bus bar four wire system, coour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, the panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but no less than 2.5 sqmm) including grouting of panel 60 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6mm, welded on all the four corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm complete all as specified and directed. The scope of work includes the following :- (a) INCOMING : - (i) Thermal magnetic MCCB 4 pole, 125 Amps, 25 KA - 01 no. (ii) Aluminium bus bar 200 Amps with insulator - 04 Nos. (iii) Instrument control fuses and indication lamp - one No. (b) OUTGOING :- (i) Thermal magnetic MCCB 3 pole, 63 Amps, 25 KA - 01 No. (ii) Thermal magnetic MCCB 3 pole, 100 Amps, 25 KA - 01 No. (iii) MCB DP, 63 Amp, 10 KA - 02 No + (Space for one No MCB).
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT Panel Board, cubicle type, suitable for 415 volts, 3 Phase, 4 wire, 50 Hz, AC supply system and tested at CPRI, having bus bar chember with insulated Aluminium bus bar four wire system, coour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, the panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but no less than 2.5 sqmm) including grouting of panel 60 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6mm, welded on all the four corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm complete all as specified and directed. The scope of work includes the following :- (a) INCOMING : - (i) Thermal magnetic MCCB 4 pole, 100 Amps, 25 KA - 01 no. (ii) Aluminium bus bar 200 Amps with insulator - 04 Nos. (iii) Instrument control fuses and indication lamp - one No. (b) OUTGOING :- (i) Thermal magnetic MCCB 3 pole, 63 Amps, 25 KA - 01 No. (ii) MCB DP, 63 Amp, 10 KA - 04 No + (Space for one No MCB).
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT Panel Board, cubicle type, suitable for 415 volts, 3 Phase, 4 wire, 50 Hz, AC supply system and tested at CPRI, having bus bar chember with insulated Aluminium bus bar four wire system, coour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, the panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but no less than 2.5 sqmm) including grouting of panel 60 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6mm, welded on all the four corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm complete all as specified and directed. The scope of work includes the following :- (a) INCOMING : - (i) Thermal magnetic MCCB 4 pole, 63 Amps, 25 KA - 01 no. (ii) Aluminium bus bar 100 Amps with insulator - 04 Nos. (iii) Instrument control fuses and indication lamp - one No. (b) OUTGOING:- (i) MCB DP, 63 Amp, 10 KA - 02 No + (Space for one No MCB).
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT Panel Board, cubicle type, suitable for 415 volts, 3 Phase, 4 wire, 50 Hz, AC supply system and tested at CPRI, having bus bar chember with insulated Aluminium bus bar four wire system, coour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, the panel shall be dust and vermin proof, IP-65 class protection and made 3.2mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but no less than 2.5 sqmm) including grouting of panel 60 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6mm, welded on all the four corners, embedded in PCC 1:2:4 using 20mm stone aggregate upto 30 cm complete all as specified and directed. The scope of work includes the following :- (a) INCOMING : - (i) Thermal magnetic MCCB 4 pole, 63 Amps, 25 KA - 01 no. (ii) Aluminium bus bar 100 Amps with insulator - 04 Nos. (iii) Instrument control fuses and indication lamp - one No. (b) OUTGOING:- (i) Thermal magnetic MCCB 3 pole, 63 Amps, 25 KA- 01 No. (ii) MCB DP, 63 Amp, 10 KA - 02 No + (Space for one No MCB).
Supply and fixing of PVC insulated unsheathed copper conductor cable 2.5 sqmm 3 runs including steel conduit from street light fitting to junction box on pole of 9 meters and making necessary connection both at junction box and street light fittings and fixing accessories complete all as directed.
Boring of holes under road, paverment, hardstanding by trenchless technology using ultra sound technique and necessary machine indluding HDPE pipe of 80mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
M & L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx 6.3mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to galvanized earth lead GI strip 32x6mm by means of bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to continuous earth wire on pole all as specified and testing on completion, including provision of earth wire protected by 40mm dia GI light grade protection pipe from test point to main board and 20mm GI medium grade watering pipe funnel, PCC earth pit and RCC cover charcoal, salt and GI wire including excavation and earth work etc complete all as directed at site. Note :- (i) The concrete pit shall be in PCC (1:3:6) type C-1 and 40mm thick precast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate with suitable handle. (ii) The cost of GI pipe for protection of earth lead/ strip including earth lead upto 7.5 mtr.
S.S Enterprises
M/s Prem Associates
GAR CONSTRUCTIONS
MORESHWAR ELECTRICALS CORPORATION
UNIQUE INDIA CONSTRUCTIONS
M/s Yash Electrical and Maintenance
B.S Constructions
ANNAPURNA ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .