Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹50.6 L+₹58,870 (1.18%)Rejected-Finance 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L2 | Rejected-Finance L2 | |
| 3 | L3₹51.5 L+₹1.5 L (2.99%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹52.9 L+₹2.9 L (5.82%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L4 | Rejected-Finance L4 | |
| 5 | L5₹55.2 L+₹5.2 L (10.4%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹99,400
Closing Date
26 Mar 2021, 6:00 pmClosed
Lt Col Bhamre Kiran S
Garrison Engineer (AF) No.1 Military Engineer Service Air Force Station No.1 Jamnagar 361 003
REPAIR/MAINTENANCE OF DG SET AND CONNECTED WORKS UNDER GE (AF) JAMNAGAR NO 1
2021_MES_428402_1
8789/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) JAMNAGAR NO.1
₹99,400
Yes
8 Apr 2021
5 Mar 2021
27 Mar 2021
5 Mar 2021
26 Mar 2021
19 Mar 2021
Amount
Maintenance and servicing of 400 KVA DG set of any make Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions and as directed-03 Nos NOTES: (i) Control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exclusive of servicing/ maintenance of the above said fittings.
(ii) Servicing of DG Set along with connected Alternator and Panel Board including 'A' Check of the Engine shall be carried out once in every month (Except during the month when 'B' check is carried out) as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG set for a period of 30 days from the date of service and shall also attend all the maintenance works as and when required in that period except in case of Major repairs. (iii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be included in the rate quoted for this item.
(iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item. (v) List of checks to be carried out under 'A' check shall be all as directed by Engineer-in-charge. (vi) The quoted rate shall be for the maintenance of One DG Set per month.
All as per Item No .1 here in before but for 320 KVA DG set -05 Nos
All as per Item No .1 here in before but for 250 KVA DG set -01 Nos
All as per Item No .1 here in before but for 200 KVA DG set -07 Nos
All as per Item No .1 here in before but for 160 KVA DG set -06 Nos
All as per Item No .1 here in before but for 100 to 125 KVA DG set -06 Nos
All as per Item No .1 here in before but for 70 to 83 KVA DG set -06 Nos
All as per Item No .1 here in before but for 62.5/63 KVA DG set -04 Nos
All as per Item No .1 here in before but for 50 KVA DG set - 01 Nos
All as per Item No .1 here in before but for 25 to 30 KVA DG set -04 Nos
All as per Item No .1 here in before but for 20 KVA DG Set - 02
All as per Item No .1 here in before but for 10 to 15 KVA DG set -04 Nos
Maintenance and servicing of 400 KVA DG set of any make Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine 'B' check of the engine including items covered in 'A' check complete for smooth functioning all as per manufacturer's instructions and as directed - 03 Nos NOTES: (i) Control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exclusive of servicing/ maintenance of the above said fittings
(ii) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set along with connected Alternator and Panel Board including items covered in 'A' Check of the Engine shall also be carried out in that month as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG set and shall also attend all the maintenance works as and when required in that period except in case of Major repairs (iii) Spare parts, engine oil and radiator coolant oil required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares/ filling of oils shall be deemed to be included in the rate quoted for this item.
(iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item,contractor to be provided fuel filter, oil filter, water filter,top head gaskets,fuel pipes, battery terminal, battery lead and distilled water. (v) List of checks to be carried out under 'B' check be all as directed by Engineer-in-charge. (vi) The quoted rate shall be for the maintenance of One DG Set per month.
All as per Item No .13 here in before but for 320 KVA DG set -05 Nos
All as per Item No .13 here in before but for 250 KVA DG set -01 Nos
All as per Item No .13 here in before but for 200 KVA DG set -07 Nos
All as per Item No .13 here in before but for 160 KVA DG set -06 Nos
All as per Item No .13 here in before but for 100 to 125 KVA DG set -06 Nos
All as per Item No .13 here in before but for 70 to 83 KVA DG set -06 Nos
All as per Item No .13 here in before but for 62.5/63 KVA DG set -04 Nos
All as per Item No .13 here in before but for 50 KVA DG set - 01 Nos
All as per Item No .13 here in before but for 25 to 30 KVA DG set -04 Nos
All as per Item No .13 here in before but for 20 KVA DG Set - 02
All as per Item No .13 here in before but for 10 to 15 KVA DG set -04 Nos
Repair / overhauling of following mentioned Self Starter assembly of DG Set by disconnecting and removing from the engine, cleaning of all accessories, replacing of worn out parts such as brushes, bushes, contact plates, jumping leads and seals, revarnishing the field coil, armature if required copper winding re-assembling the same and re-fixing into the engine including testing all as per manufacturer's instructions and as directed. (a) Self starter assembly, 24 Volt DC 250/320/400
All as per item No 25 above but Self starter assembly, 24Volt DC 160/180/200
All as per item No 25 above but Self starter assembly, 12Volt DC up to 100 kva
Repair / overhauling of following mentioned radiator assembly of DG set by disconnecting and removing from the engine, dismantling the top and bottom chambers, descaling the sediments, scales, corrosion etc. by means of acid, cleaning and high pressure water washing, air cleaning, re-assembling the same with new gaskets including arresting leakages, if any and fixing to the engine with new hoses, clips etc. all as required and as directed. Note: The rate quoted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges. (a) Radiator assembly320/ 400 KVAcapacity
All as per item No 28 above but Radiator assembly 250 KVA/ 200 KVA/180 KVA capacity
All as per item No 28 above but Radiator assembly 160 KVA capacity
All as per item No 28 above but Radiator assembly 100KVA/75 KVA/70 KVA/82.5 KVA/ 62.5 KVA/ 40 KVA capacity.
All as per item No 28 above but Radiator assembly 100KVA/75 KVA/70 KVA/82.5 KVA/ 62.5 KVA/ 50 KVA capacity.
All as per item No 28 above but Radiator assembly 10 TO 30 KVA capacity.
Supply and Fix in repair Lead acid battery, 12 volt, 180 AH Make :- Exide/ Amco/Amron
Supply and Fix in repair Lead acid battery, 12 volt, 150 AH Make :- Exide/ Amco/Amron
Supply and Fix in repair Lead acid battery, 12 volt, 130 AH Make :- Exide/ Amco/Amron
Supply and Fix in repair Lead acid battery, 12 volt, 120 AH Make :- Exide/ Amco/Amron
Supply and Fix in repair Lead acid battery, 12 volt, 92 AH Make :- Exide/ Amco/Amron
Supply and filling Engine oil SAE 20W-40W Make :- VOLVOLINE/ IOC/HP
Supply and filling radiator coolant Make : VOLVOLINE/ IOC/HP
M&L for distilled water (electrolyte ) to be filled in lead acid batteries all as directed by Engr-In-Charge
Supply and Fix in repair solenoid switch, 240 volts, suitable for 400/250/200/180/160 KVA DG set
Supply and Fix in repair solenoid switch, 240 volts, suitable for 83.5/75/70/62.2 KVA DG set
Supply and Fix in repair solenoid switch, 240 volts, suitable for 10 to 50 KVA DG set
S&F in repair Automatic voltage regulator (AVR) Suitable for DG Set 400/250/200/180/160/100 KVA
S&F in repair Automatic voltage regulator (AVR) Suitable for DG Set 10 to 83 KVA
Supply and fixing in repair Battery charger panel mounted 24 volt 15 Amps suitable for AMF Panels of DG Set 100/125/160/200/250/400 KAV capacity
Supply and fixing in repair Battery charger panel mounted 12 volt 15 Amps suitable for AMF Panels of DG Set 10 to 83 KVA KAV capacity
Supply and fix in repair fan belt as per existing make for the following capacities of DG sets. (a) 250 to 400KVA
All as per item No 49 above but 200/180/ 160 KVA
All as per item No 49 above but 125/100 KVA
All as per item No 49 above but 70/ 75/82.5 KVA
All as per item No 49 above but 10 to 63 KVA
Supply & fix in repair Air filter element as per existing make for the following capacities of DG sets. (a) 400 KVA - 03
All as per item No 54 above but 320 KVA
All as per item No 54 above but 250 KVA
All as per item No 54 above but 200 KVA
All as per item No 54 above but 160 KVA
All as per item No 54 above but 100 t0 125 KVA
All as per item No 54 above but 70 KVA to 83 KVA
All as per item No 54 above but 50 KVA
All as per item No 54 above but 25 to 30 KVA
All as per item No 54 above but 10 to 20 KVA
Overhauling the fuel injection pump assy and injectors, disconnecting the fuel supply lines, and taking out FIP to workshop for servicing/repair, replacement the worn out/un serviceable parts like service kit, D-Valve, Elements, nozzles etc., as required and calibrating the same, assembling at site and testing on load all as directed for the following capacity of Gen sets:- (a) 400 KVA
All as per item No 64 above but 320 KVA
All as per item No 64 above but 250 KVA
All as per item No 64 above but 200 KVA
All as per item No 64 above but 160 KVA
All as per item No 64 above but for 100 to 125 KVA
All as per item No 64 above but 70 to 83 KVA
All as per item No 64 above but 64.5 /63 KVA
All as per item No 64 above but 50 KVA
All as per item No 64 above but 25 to 30 KVA
All as per item No 64 above but 20 KVA
All as per item No 64 above but 10 to 15 KVA
Disconnecting the inlet and outlet supply of the fuel tank cleaning the tank internally by draining out the fuel into clean container , taking out the corroded sludge and foreign impurities ,cleaning with pressure water and air, drying the tank, preparing the external old painted surface of tank including steel platform /stand of fuel tank and painting the prepared surface with one coat of synthetic enamel paint of existing shade, including writing SM /MES No. complete all as directed for the following capacity of Gen sets :-400 KVA DG set Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) Note : Substitute fuel tank for cleaning purpose including all reqd items is deemed to be included in the rate quoted.
All as per item No 76 above but 320 KVA - 05 Nos.
All as per item No 76 above but 250 KVA - 01 Nos.
All as per item No 76 above but 200 KVA - 07 No.
All as per item No 76 above but 160 KVA - 06 Nos.
All as per item No 76 above but for 100 to 125 KVA - 06 No.
All as per item No 76 above but 70 to 83 KVA - 06 Nos.
All as per item No 76 above but 62.5 /63 KVA - 04 Nos.
All as per item No 76 above but 50 KVA - 01 Nos.
All as per item No 76 above but 25 to 30 KVA - 04 Nos.
All as per item No 76 above but 20 KVA - 02 Nos.
All as per item No 76 above but 10 to 15 KVA - 04 Nos.
Supply & fix in repair solenoid coil of self starter of 24V capacity of any capacity DG sets taking out of self and transportation to workshop is deemed to be included quoted rate all as directed. suitable for Make:- Kirloskar / Cummins / Greaves
Supply & fix in repair solenoid coil of self starter of 12V capacity of any capacity DG sets taking out of self and transportation to workshop is deemed to be included quoted rate all as directed suitable for Make:- Kirloskar / Cummins / Greaves
M&L for repair in Right / Left hand lock with catcher for acoustic enclosure (canopy) of any capacity DG sets all as specified & directed.
M&L in repair for Dial type mechanical fuel level indicator for any capacity DG set complete all as specified & directed.
S&F in repair 4 Pole 400 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge. Make L&T (Type MNX 400) or equivalent of make siemens / ABB
S&F in repair 4 Pole 265 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge. Make L&T (Type MNX 265) or equivalent of make siemens/ABB
S&F in repair 4 Pole 225 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge Make L&T (Type MNX 225) or equivalent of make siemens/ABB
S&F in repair 4 Pole 185 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge. Make L&T (Type MNX 185) or equivalent of make siemens / ABB
S&F in repair 4 Pole 140 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge. Make L&T (Type MNX 140) or equivalent of make siemens / ABB
S&F in repair 4 Pole 95 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge. Make L&T (Type MNX 95) or equivalent of make siemens/ABB
S&F in repair MCCB 400 Amps, 4 pole, breaking capacity 36/35 kA with thermal Magnetic release range 320 Amps to 400 Amps, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair MCCB 250 Amps, 4 pole, breaking capacity 36/35 kA with thermal Magnetic release range 200 Amps to 250 Amps, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair MCCB 160 Amps, 4 pole, breaking capacity 25 kA, fixed type fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair MCCB 100 Amps, 4 pole, breaking capacity 25 kA, fixed type fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair indicating lamp LED type, size 22.5 mm voltage 240 V AC. fixing in existing AMF panel & connecting complete all as specified & directed by Engr-in-Charge. Make:- BCH / C&S / Havells / Simens / L&T
S&F in repair push button with element for PB1 - Engine start / PB2 - Engine stop / PB3 - DG contactor ON / PB4 - DG contactor OFF / PB5 - Mains contactor ON / PB6 - Mains contactor OFF, fixing in existing AMF panel & connecting complete all as specified & directed by Engr-in-Charge. Make:- BCH / C&S / Havells / Simens / L&T
S&F in repair Aux control relay with socket 3 C/O 12 V DC, 5 A fixing in existing AMF panel & connecting complete all as specified & directed by Engr-in-Charge. Make:- BCH / C&S / Havells / Simens / L&T
S&F in repair amps meter digital type 0-400 Amps of size 96 mm x 96 mm, fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
S&F in repair C T ratio 100 A Class of accuracy 1, VA 15, ring type fixing in existing AMF panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair Digital type DC Voltmeter, 0 to 30 V DC, size 96 mm x 96 mm fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
S&F in repair Digital type DC Ammeter, 0 to 20 ADC, size 96 mm x 96 mm fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
S&F in repair Electronic type Hooter, supply voltage 12 V, DC flush mounted, suitable for DG set, fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
Supply and fix in repair MCB’s single pole 6-32 Amps, 415 volts with ‘C’ curve, fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
Supply and fix in repair Aux supply 12 V DC, voltage sensing relay 415 V AC fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge. Make:- BCH / C&S / Havells / Simens / L&T
Supply and fix in repair electronic type auto battery charger for AMF of any capacity DG sets 440 / 12 V output voltage complete all as directed.
S & F in repair electronic controller for AMF panel of capacity 63 to 100 KVA DG sets showing the complete details to run the DG sets and to stop the DG sets complete with logical programming as per existing AMF panel all as directed. Make : Wood Word / Deep sea Electronic
S & F in repair electronic controller for AMF panel of capacity 125 to 160 KVA DG sets showing the complete details to run the DG sets and to stop the DG sets complete with logical programming as per existing AMF panel all as directed. Make : Wood Word / Deep sea Electronic
S & F in repair electronic controller for AMF panel of capacity 200 to 400 KVA DG sets showing the complete details to run the DG sets and to stop the DG sets complete with logical programming as per existing AMF panel all as directed. Make : Wood Word / Deep sea Electronic
Dismantling of alternator assembly complete from DG set of capacity from 10KVA to 400 KVA and removing the burnt out copper winding cleaning of limb thoroughly and rewinding the same with supper enameled copper winding wire of the same gauge and turn with proper class of insulation impregnated & baking, assembling and testing complete all as specified & directed by Engineer-in-Charge. Note : All cost is inclusive of to & fro to local workshop if reqd including veh reqd for it.
Supply & fix in repair silencer assembly complete suitable for DG set cap 10 to 35 KVA
Supply and installation, testing, commissioning, factory made, outdoor type, AMF Panel board, suitable for 160 KVA DG set confirming to IS-5039, cubical type base mounting with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour.......
.......coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old AMF panel , Controller with battery charger 12/24 V all as specified and directed & Consisting of the following equipment connecting up incoming and out going cables complete with glands and lugs and chamber painted with two coats of aluminium paint over a coat of red oxide primer including mounting the chamber with suitable size of bolts/ nuts including taking down existing unserviceable chamber of any description all as specified and as directed. Note: Rate included Excavation, earth work and pcc work and complete connected work
(a) 4 Pole 250 Amp power Contractor, AC 3 duty, coil voltage 230 VAC - 02 Nos
(b) MCCB, 250 Amps 4 pole 25 KA 50 Hz - 02 Nos
(c) Panel should be Internally prewired with suitable size of copper conductor PVC insulated cable with colour coding - 01 job
(f) Indicating lamp LED type , Size 22.5 mm voltage 240 VAC. DG ON indicating lamp , Mains MCCB ON indication lamp , SC Supply ON indicating lamp. - 06 Nos
(g) push button with element PB1 - Engine start PB2 - Engine stop PB3 - DG contactor ON PB4 - DG contactor OFF PB5 - Mains contactor ON PB6 - Mains contactor OFF
(h) Aux control relay with socket 3 C/O 24 VDC, 30 A - 04 Nos
(j) Digital type DC Voltmeter, 0 to 30 VDC - 01 Nos
(k) Electronic type Hooter, supply voltage 12 V DC 96 Sqmm flush mounted - 01 No
(l) Miniature circuit breaker , 1 pole 6 Amps with over load & short circuit protection , short circuit strength 10 kA - 06 Nos .
(m) Miniature circuit breaker , 1 pole 10 /16 Amps with over load & short circuit protection , short circuit strength 10 KA. - 02 Nos
(n) Neutral link rated current 15 A -01 No
(o) Aux supply 24 V DC , voltage sensing relay 415 VAC. - 02 Nos
Supply and installation, testing, commissioning, factory made, outdoor type, AMF Panel board, suitable for 250 KVA DG set confirming to IS-5039, cubical type base mounting with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour......
......coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old AMF panel , Controller with battery charger 12/24 V all as specified and directed & Consisting of the following equipment connecting up incoming and out going cables complete with glands and lugs and chamber painted with two coats of aluminium paint over a coat of red oxide primer including mounting the chamber with suitable size of bolts/ nuts including taking down existing unserviceable chamber of any description all as specified and as directed. Note: Rate included Excavation, earth work and pcc work and complete connected work
(a) 4 Pole 320 Amp power Contractor, AC 3 duty, coil voltage 230 VAC - 02 Nos
(b) MCCB, 320 Amps 4 pole 25 KA 50 Hz - 02 Nos
(c) Panel should be Internally prewired with suitable size of copper conductor PVC insulated cable with colour coding - 01 job
(f) Indicating lamp LED type , Size 22.5 mm voltage 240 VAC. DG ON indicating lamp , Mains MCCB ON indication lamp , SC Supply ON indicating lamp. - 06 Nos
(g) push button with element PB1 - Engine start PB2 - Engine stop PB3 - DG contactor ON PB4 - DG contactor OFF PB5 - Mains contactor ON PB6 - Mains contactor OFF
(h) Aux control relay with socket 3 C/O 24 VDC, 30 A - 04 Nos
(j) Digital type DC Voltmeter, 0 to 30 VDC - 01 Nos
(k) Electronic type Hooter, supply voltage 12 V DC 96 Sqmm flush mounted - 01 No
(l) Miniature circuit breaker , 1 pole 6 Amps with over load & short circuit protection , short circuit strength 10 kA - 06 Nos .
(m) Miniature circuit breaker , 1 pole 10 /16 Amps with over load & short circuit protection , short circuit strength 10 KA. - 02 Nos
(n) Neutral link rated current 15 A -01 No
(o) Aux supply 24 V DC , voltage sensing relay 415 VAC. - 02 Nos
Supply and installation, testing, commissioning, factory made, outdoor type, AMF Panel board, suitable for 400 KVA DG set confirming to IS-5039, cubical type base mounting with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour.......
.......coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old AMF panel , Controller with battery charger 12/24 V all as specified and directed & Consisting of the following equipment connecting up incoming and out going cables complete with glands and lugs and chamber painted with two coats of aluminium paint over a coat of red oxide primer including mounting the chamber with suitable size of bolts/ nuts including taking down existing unserviceable chamber of any description all as specified and as directed. Note: Rate included Excavation, earth work and pcc work and complete connected work
(a) 4 Pole 500 Amp power Contractor, AC 3 duty, coil voltage 230 VAC - 02 Nos
(b) MCCB, 500 Amps 4 pole 25 KA 50 Hz - 02 Nos
(c) Panel should be Internally prewired with suitable size of copper conductor PVC insulated cable with colour coding - 01 job
(g) push button with element PB1 - Engine start PB2 - Engine stop PB3 - DG contactor ON PB4 - DG contactor OFF PB5 - Mains contactor ON PB6 - Mains contactor OFF
(h) Aux control relay with socket 3 C/O 24 VDC, 30 A - 04 Nos
(j) Digital type DC Voltmeter, 0 to 30 VDC - 01 Nos
(k) Electronic type Hooter, supply voltage 12 V DC 96 Sqmm flush mounted - 01 No
(l) Miniature circuit breaker , 1 pole 6 Amps with over load & short circuit protection , short circuit strength 10 kA - 06 Nos .
(m) Miniature circuit breaker , 1 pole 10 /16 Amps with over load & short circuit protection , short circuit strength 10 KA. - 02 Nos
(n) Neutral link rated current 15 A -01 No
(o) Aux supply 24 V DC , voltage sensing relay 415 VAC. - 02 Nos
Supply and installation, testing, commissioning, factory made, outdoor type, AMF Panel board, suitable for 83/100 KVA DG set confirming to IS-5039, cubical type base mounting with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour.......
........coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old AMF panel , Controller with battery charger 12/24 V all as specified and directed & Consisting of the following equipment connecting up incoming and out going cables complete with glands and lugs and chamber painted with two coats of aluminium paint over a coat of red oxide primer including mounting the chamber with suitable size of bolts/ nuts including taking down existing unserviceable chamber of any description all as specified and as directed. Note: Rate included Excavation, earth work and pcc work and complete connected work
(a) 4 Pole 160 Amp power Contractor, AC 3 duty, coil voltage 230 VAC - 02 Nos
(b) MCCB, 160 Amps 4 pole 25 KA 50 Hz - 02 Nos
(c) Panel should be Internally prewired with suitable size of copper conductor PVC insulated cable with colour coding - 01 job
(g) push button with element PB1 - Engine start PB2 - Engine stop PB3 - DG contactor ON PB4 - DG contactor OFF PB5 - Mains contactor ON PB6 - Mains contactor OFF
(h) Aux control relay with socket 3 C/O 24 VDC, 30 A - 04 Nos
(j) Digital type DC Voltmeter, 0 to 30 VDC - 01 Nos
(k) Electronic type Hooter, supply voltage 12 V DC 96 Sqmm flush mounted - 01 No
(l) Miniature circuit breaker , 1 pole 6 Amps with over load & short circuit protection , short circuit strength 10 kA - 06 Nos .
(m) Miniature circuit breaker , 1 pole 10 /16 Amps with over load & short circuit protection , short circuit strength 10 KA. - 02 Nos
(n) Neutral link rated current 15 A -01 No
(o) Aux supply 24 V DC , voltage sensing relay 415 VAC. - 02 Nos
Material and Labour for cleaning of dust particles from inside the AMF Panel by air blowers, tightening of loose connections, filling of gaps with sealants, removing of vegetation, surface dressing surrounding the panel, welding of damaged panel doors, fixing of hinges, providing locking arrangements, applying one coat of primer, painting of panel with two coats synthetic enamel paint of existing colour complete including providing lock all as specified and directed by Engr-in-charge.
M&L for taking out fuel tank from 200 KVA DG Set, welding / brazing at all leakage joint to make leak proof & reinstalled as specified & directed by Engg-in-charge.
Supply & fix in repair AMF controller of 400 KVA DG Set of existing make complete (officer Mess) all as specified and directed by Engr-in-charge.
Supply & fix in repair AMF controller of 250/320 KVA DG Set of existing make complete all as specified and directed by Engr-in-charge.
Supply & fix in repair AMF controller of 160/200 KVA DG Set of existing make complete all as specified and directed by Engr-in-charge.
Supply & fix in repair AMF controller of 63/100 KVA DG Set of existing make complete all as specified and directed by Engr-in-charge.
Supply & fix in repair AMF controller of 10/50 KVA DG Set of existing make complete all as specified and directed by Engr-in-charge.
(Note: (i) During breakdown of any DG set contractor is liable to trace out the defect within 12 hrs under intimation to JE/Engineer-in-Charge. (ii) Contractor is bound to rectify the defect within 24 hrs if contractor is unable to do so panel recovery of Rs.200/- per hour will be initiated upto 48 hours. Quoted rates is deemed to be inclusive of all cost reqd for its rectification including T&P.
MADHAV ENTERPRISE
Chamunda Kruparefrigeration
Vijay Construction Co
Sukhi Electricals
Hirachand Sunderji and co
SAGATHIYA BUILDERS
jitendra c joisar
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .