| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹94,320Qualified Make: Okaya
Model: Okaya 150Ah Tubular Battery MAIN BUS STAND NEAR SYNDICATE BANK DHAULANA GHAZIABAD UTTAR PRADESH 245301 | HAPUR | UTTAR PRADESH | 245301 | Make: Okaya
Model: Okaya 150Ah Tubular Battery | L1 | Qualified | |
| 2 | L2₹97,200+₹2,880 (3.05%)Qualified Make: Okaya
Model: Okaya Inverter Battery 100 2 GROUND FLOOR STREET NO 10 EAST AZAD NAGAR KRISHNA NAGAR DELHI 110051 | EAST DELHI | DELHI | 110051 | Make: Okaya
Model: Okaya Inverter Battery | L2 | Qualified | |
| 3 | L3₹98,360+₹4,040 (4.28%)Qualified Make: LUMINOUS
Model: LUMINOUS EC18036 150Ah Lead Acid Battery 100 2 GALI NO 10 EAST AZAD NAGAR EAST DELHI DELHI 110051 EAST DELHI DELHI 110051 | EAST DELHI | DELHI | 110051 | Make: LUMINOUS
Model: LUMINOUS EC18036 150Ah Lead Acid Battery | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
28 May 2018, 12:00 pmClosed
lead acid battery Lead Acid Battery ( 8 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Stationary cells and Batteries
Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 Stationary cells and Batteries
Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container ABS Hard Rubber
Fibre Reinforced Plastics (FR P)
Polypropylene
ABS Rated Capacity at C20 discharge (AH) 150 150 Warranty (Years) 2 Years 1 Year
2 Years
3 Years
4 Years
5 Years Battery Condition Dry Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 9200 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn.
corresponding Ah Yes. - 1/3 No.of cells per Battery (No.) 6 Cells for 12 Volt battery - CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab Manak Bhavan
9 Bahadur shah Zafar Marg
New Delhi-110002 - Name of the Lab Bureau of Indian Standards - Test Report No. R-410J5563 - Test Report Date 08-11-20 17 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells
and for Batteries made from them for use in portable applications R-410J5563 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ashok Kumar Thakur 784026
O/O The Commandant
68th Bn
SSB Debendra Nagar 8 15 EMD Required No ePBG Required No
103377
GEM/2018/B/14751
lead acid battery
15 days
Assam; Sonitpur
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| lead acid battery Lead Acid Battery ( 8 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Types of Lead Acid of Battery Stationary cells and Batteries | - | - | - |
| Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 Stationary cells and Batteries | - | - | - |
| Lead Acid Type (With Tubular Positive Plates) conforming to IS:1651/1991 Nominal Voltage of Battery (volts) 12.0 Volt 12.0 Volt Material of container ABS Hard Rubber | - | - | - |
| Fibre Reinforced Plastics (FR P) | - | - | - |
| Polypropylene | - | - | - |
| ABS Rated Capacity at C20 discharge (AH) 150 150 Warranty (Years) 2 Years 1 Year | - | - | - |
| 2 Years | - | - | - |
| 3 Years | - | - | - |
| 4 Years | - | - | - |
| 5 Years Battery Condition Dry Charged - CONSTRUCTIONAL Dimensions (L x W x H) (mm x mm x mm) As per relevant IS Specifications - Volume of Electrolyte (ml) 9200 - Weight of Dry Battery (Kg) shall be as per relevant IS: Specn. | - | - | - |
| corresponding Ah Yes. - 1/3 No.of cells per Battery (No.) 6 Cells for 12 Volt battery - CERTIFICATIONS Availability of Test Reports from Central Govt./NABL/ILAC accrediated Lab showing conformity to the specifications Yes - Address of the Lab Manak Bhavan | - | - | - |
| 9 Bahadur shah Zafar Marg | - | - | - |
| New Delhi-110002 - Name of the Lab Bureau of Indian Standards - Test Report No. R-410J5563 - Test Report Date 08-11-20 17 - Compulsory Registration (CRS) of BIS for safety as per IS 16046 as applicable. Secondary Cells and (Batteries containing Alkaline or other non- acid Electrolytes-Safety Requirements for Portable sealed secondary cells | - | - | - |
| and for Batteries made from them for use in portable applications R-410J5563 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ashok Kumar Thakur 784026 | - | - | - |
| O/O The Commandant | - | - | - |
| 68th Bn | - | - | - |
| SSB Debendra Nagar 8 15 EMD Required No ePBG Required No | - | - | - |
Exempted
28 May 2018
18 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_103377.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .