Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAdmitted-Finance | ₹2.1 L | L1 | Admitted-Finance |
| 2 | L2₹2.2 LAdmitted-Finance | ₹2.2 L | L2 | Admitted-Finance |
| 3 | L3₹2.2 LAdmitted-Finance 110 MINI SHOPPING COMPLEX NEHRU MARKET JAMMU | ₹2.2 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Rishabh Electricals and Mechanical Works L3 | M/S ISHAN ELECTRICAL and MECH. ENGG. WORKS L2 | VEE AUTO TRADERS L1 |
|---|---|---|---|---|---|---|
| 2.00 | Repair/Replacement of Damaged aluminium insulation of MS Chiller Pipelines in Emergency Block of GMCH Jammu. The job includes switching off the main power supply to the units and draining of all the water from the chiller plants and chiller pipelines and removing the insulating Aluminium sheet from the damaged/wornout portion from the surface of the pipeline by using sheet cutters etc. Then the C-shaped damaged thermocol is removed from the surface of the pipeline with the help of tools and tackles. The surface of the MS Pipeline is cleaned thoroughly to remove all the traces of adhesive and thermocol and the rusted portions of 4” MS Pipeline are removed with the help of pipe cutter/gas welding and new 4” diameter MS Pipeline (03 meter) is fixed in that portions by gas welding method .. The job also includes providing and fitting of MS bends 02 No’s of 4” diameter by replacing the rusted/damaged ones. All the MS Pipeline joints are welded in double layers so that all the joints are leak proof and to test the joints water is filled in the chiller plants and MS Pipelines and water and circulated and checked for leakage if any from the joints and is rectified again by applying another layer of welding. The water is again drained from the chiller plants and MS pipelines and two coatings of special adhesive paint is applied over the surface of the MS pipeline and pre fabricated C shaped thermocol (50 mtr)is fixed all over it. Then aluminium sheet of 26 gauge (50 mtr) is fixed all over the thermocol with the help of crimping tool and star shaped rivets. Complete job includes cost of tools and tackles required for execution of the job, material, all types of taxes and labour charges etc. | 1 | job | 0.02 ₹2,19,030 | 0.02 ₹2,15,600 | 0.02 ₹2,14,522 |
Tender Value
₹2.2 L
EMD Value
₹5,000
Closing Date
6 May 2026, 4:00 pmClosed
XEN MH DIVISION GMCH JAMMU
XEN MH DIVISION GMCH JAMMU
Repair Replacement of Damaged Aluminium Insulation of MS Chiller Pipelines laid in Emergency Block of GMCH Jammu.
2026_PWDJK_308833_1
MHDJ/e-NIT 22 of 2026-27
Open Tender
Repair and Maintenance Services
10 days
GMCH
as per e nit
2 documents required · 2 mandatory
₹200
XEN MH DIVISION GMCH JAMMU
₹5,000
18 May 2026
27 Apr 2026
7 May 2026
27 Apr 2026
6 May 2026
29 Apr 2026
27 Apr 2026 - 6 May 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
Repair/Replacement of Damaged Aluminium Insulation of MS Chiller Pipelines laid in Emergency Block of GMCH Jammu...
MHDJ/e-NIT 22 of 2026-27 Dated: 27.04.2026 Due : 06.05.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
2 Repair/Replacement of Damaged aluminium insulation of MS Chiller Pipelines in Emergency Block of GMCH Jammu. The job includes switching off the main power supply to the units and draining of all the water from the chiller plants and chiller pipelines and removing the insulating Aluminium sheet from the damaged/wornout portion from the surface of the pipeline by using sheet cutters etc. Then the C-shaped damaged thermocol is removed from the surface of the pipeline with the help of tools and tackles. The surface of the MS Pipeline is cleaned thoroughly to remove all the traces of adhesive and thermocol and the rusted portions of 4” MS Pipeline are removed with the help of pipe cutter/gas welding and new 4” diameter MS Pipeline (03 meter) is fixed in that portions by gas welding method .. The job also includes providing and fitting of MS bends 02 No’s of 4” diameter by replacing the rusted/damaged ones. All the MS Pipeline joints are welded in double layers so that all the joints are leak proof and to test the joints water is filled in the chiller plants and MS Pipelines and water and circulated and checked for leakage if any from the joints and is rectified again by applying another layer of welding. The water is again drained from the chiller plants and MS pipelines and two coatings of special adhesive paint is applied over the surface of the MS pipeline and pre fabricated C shaped thermocol (50 mtr)is fixed all over it. Then aluminium sheet of 26 gauge (50 mtr) is fixed all over the thermocol with the help of crimping tool and star shaped rivets. Complete job includes cost of tools and tackles required for execution of the job, material, all types of taxes and labour charges etc. 1 job Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.93 MB
BOQ_1000379.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid