Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | ₹14.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹15.0 L+₹7,985 (0.54%)Rejected-Finance MES COLONY KUMBHIGRAM AIRPORT CACHAR ASSAM 788109 | KUMBHIGRAM | CACHAR | ASSAM | 788109 | ₹15.0 L+₹7,985 (0.54%) | L2 | Rejected-Finance L2 |
| 3 | L3₹15.2 L+₹29,915 (2.01%)Rejected-Finance | ₹15.2 L+₹29,915 (2.01%) | L3 | Rejected-Finance L3 |
| 4 | L4₹15.3 L+₹35,583 (2.39%)Rejected-Finance | ₹15.3 L+₹35,583 (2.39%) | L4 | Rejected-Finance L4 |
| 5 | L5₹15.4 L+₹49,550 (3.32%)Rejected-Finance | ₹15.4 L+₹49,550 (3.32%) | L5 | Rejected-Finance L5 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
17 Jul 2023, 6:00 pmClosed
AGE I AF Kumbhirgram
AGE I AF Kumbhirgram Military Engineer Services PO Kumbhirgram Assam Pin 788109 Tele 03841282376
REPAIR MAINT OF CEILING FANS, EXHAUST FANS GEYSER AND CERTAIN POINT WIRING AND ALLIED WORKS AT AFS KUMBHIRGRAM
2023_MES_601608_2
8492/2023-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STATION KUMBHIRGRAM
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
AGE I AF Kumbhirgram
₹30,000
Yes
4 Sept 2023
6 Jul 2023
19 Jul 2023
6 Jul 2023
17 Jul 2023
10 Jul 2023
Amount
Taking down carefully copper/ Aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, sockets, boards, DB, MCB, light fittings etc), removing materials from site and making good disturbed surfaces of walls, floors etc, complete all as specified and directed.
Material and labour for concealed point wiring for one light/ Fan point controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn through and including 20 mm dia (medium grade) non metallic PVC concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including pressed steel sunken boxes, having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm(concealed type) with 3mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc or metal flush boxes suitable for mounting modular switch, socket etc., including testing on completion, including cutting chases for concealed conduit , making good the disturbed surfaces using cement mortar 1:3 complete all as specified and directed.
All as per Item No 2 here-in before but for one three pin switch socket outlet, 5 Amp on independent board complete all as specified and directed.
All as per item No 2 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathed multistranded FRLS copper conductor, complete all as specified and directed.
Material and labour for point wiring (surface type) for one light/ Fan point controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade in and including PVC capping and casing (double lock, ISI Marked) of suitable size with all necessary fittings along with 1.5 sqmm continuous PVC insulated unsheathed stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including PVC rectangular switch board with plastic laminated sheet cover for mounting switches, sockets, fan regulators etc or modular plastic surface boxes suitable for mounting modular switch, socket etc., including testing on completion complete all as specified and directed.
All as per Item No 5 here-in-before but for one switch socket outlet, 5 Amp on independent board all as specified and as directed.
All as per item No 5 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathed multistranded FRLS copper conductor, complete all as specified and directed.
All as per item No 5 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 4.0 sqmm PVC insulated unsheathed multistranded FRLS copper conductor, complete all as specified and directed.
Cutting chases for concealed conduit wiring, making good to the disturbed surfaces, facings and pointing in cement mortar 1:3 in brick walls, cutting not exc 10 cm girth, complete all as specified and directed.
M&L for sub main wiring with 2 run of single core 4.0 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit/ casing capping of minimum size 25 mm alongwith accessories on roof/walls/ ceiling etc including one run of 4.0 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 4.0 Sqmm single core cable, one run of 4.0 Sqmm earth wire and one run of PVC conduit/ casing capping shall be measured as one run length.
M&L for sub main wiring with 2 run of single core 6.0 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit/ casing capping of minimum size 25 mm alongwith accessories on roof/walls/ ceiling etc including one run of 6.0 Sqmm FRLSH (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 6.0 Sqmm single core cable, one run of 6.0 Sqmm earth wire and one run of PVC conduit/ casing capping shall be measured as one run length.
Supply and fix Switch piano flush button single pole, one way 6 Amp, complete all as specified and directed.
Supply and fix Switch Socket combination 2-in 1 flush type 6 Amps 5pin, 240 volts complete all as specified and directed.
Supply and fix Switch Socket combination 2-in 1 flush type 6 and 16 Amps 5pin, 240 volts complete all as specified and directed.
Supply and fix Ceiling rose, 3 pole, PVC/polycarbonate, insulated body (ISI Marked) complete all as specified and directed.
Supply and fix Stepped type electronic fan regulator, AC 50 HZ, 230V,100 Watts, minimum 4 steps (ISI Marked), complete all as specified and directed.
Supply and fix modular switch 1 way 6 A, 1 module , complete all as specified and directed.
Supply and fix modular switch 1 way 16 A, 1 module , complete all as specified and directed.
Supply and fix modular Socket 2-in 1, 5 pin 6 Amps, 2 module complete all as specified and directed.
Supply and fix modular Socket 2-in 1, 3 pin 16 Amps, 2 module complete all as specified and directed.
Supply and fix modular fan step regulator, 100 Watts, 2 module, complete all as specified and directed.
Supply and fix modular white cover plate with frame 3 module, complete all as specified and directed.
Supply and fix modular white cover plate with frame 4 module, complete all as specified and directed.
Supply and fix modular white cover plate with frame 6 module, complete all as specified and directed.
Supply and fix modular white cover plate with frame 8 module, complete all as specified and directed.
Supply and fix in repair PVC casing and caping of size 20X12mm complete all as specified and directed.
Supply and fix in repair PVC casing and caping of size 25X12mm complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB 4 way SPN double door suitable for 240 V, fixed flushed on walls including necessary wall cutting and making good disturbed surfaces and blanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB 6 way SPN double door suitable for 240 V, fixed flushed on walls including necessary wall cutting and making good disturbed surfaces and blanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed.
S&F miniature circuit breaker (MCBs) SPN , 240 Volt, 32-40 Amps, "C" series,10 KA breaking capacity, complete all as specified and directed.
Fixing only miniature circuit breaker (MCBs) of any cap , 240 Volt, (serviceable MCB obtained from unserviceable BD's shall be re-used) complete all as specified and directed.
S&F MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps complete all as specified and directed.
Supply and fix in repair Switch Socket combination 5-in 1 flush type 6 Amps 5pin, 230 volts with PVC box complete all as specified and directed
Supply and fix in repair Switch socket combination ,3 pin 16 amps (ISI marked) flush type, with PVC box complete all as specified and directed.
S&F in repair MS anchoring bolt of size 10mmx75mm long including necessary drilling on wall for fixing of frame/ geyser all as specified and directed.
Supply and fix in repair sheet metal enclosure with socket plug top and MCB single pole 10 Amp, 240V complete all as specified and directed.
Supply and fix in repair sheet metal enclosure with socket plug top and MCB single pole 20 Amp, 240V complete all as specified and directed
Disconnecting electrical wire from ceiling rose, taking down ceiling fan/ wall mounted fan of any type/ size and make, cleaning all dust, open it to apply fresh lubrication/ grease and to make the ceiling fan noise free for smooth functioning (including replacement of worn-out/ unserviceable capacitor, connector, bearing, down rod, flexible wire etc.) assembling the repaired fan testing, hanging using new nut and bolt with locking arrangement, connection with point wiring,testing complete all as directed. Note: Spare parts to be replaced shall be measured and paid separately)
All as per item No. 38 here-in-above but for Exhaust fan 230/300/450 mm sweep .
M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.,complete all as specified and directed.
M&L for Rewinding of Ceiling fan/ wall mounted fan of any sweep after dismenting complete motor assembly, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unserviceable bearings / bushings, assemble of motor and statar unit with capacitor, connecting wire, down rod, blades and testing complete. Note: 1. Cost of transportation will be inclusive of quoted rate. 2. Spares require for repair such as bearing, bushing, capacitor shall be measured and paid separately as supply only. 3. Cost of Connector block and capacitor holder shall be inclusive of the quoted rate.
All as per item No. 41 here-in-above but for Exhaust fan 450 mm sweep industrial type.
All as per item No. 41 here-in-above but for Exhaust fan 230mm/300 mm sweep .
Supply only ball bearing of No 6201/6202/6203/6204 of Make:SKF/Tata/NBC.
Supply only G.M. Bushing for ceiling fan as per existing pattern.
Supply only capacitor AC for 230 volts 50 Hz of capacity 1.8/2.0/2.25/2.5 Mfd.
Supply only capacitor AC for 230 volts 50 Hz of capacity 3.15/4.0 Mfd.
Supply only anti sucidal down rod suitable for ceiling fan.
Supply and replacement of PVC insulated sheathed twin twisted stranded copper flexiable wire of size 1.5 Sqmm all as specified and directed.
S&F in repair PVC plug top 5Amps, 3 pin, 230 volts complete all as directed.
S&F in repair PVC plug top 15Amps, 3 pin, 230 volts complete all as directed.
Supply and replacement PVC insulated PVC sheathed copper flexiable wire multistrand 2.5 sqmm 3 core, ISI marked, complete all as directed.
Taking down geyser after disconnecting water and electric connection of any type, size and make, opening the plate and removing heating element, scraipng and cleaning mud deposites on the heating element and inside surface of geyser for proper functioning of geyser (including replacement of worn-out/ unserviceable items like heating element, thermostat, fusible plug etc.) assembling the geyser including writing MES No with black synthetic enamel paint , testing, hanging on existing position, connection with pipe complete all as directed by Engr-in charge. Note:Spare parts to be replaced shall be measured and paid seperately as supply only.
Supply only thermostat ISI marked suitable for geysers 25 Ltrs to 50 Ltrs Capacity . Make- Bajaj/Venus/Recold
Supply only fusible plug ISI marked suitable for 25 and 50 ltrs capacity Geysers .
Supply only heating element ISI Marked round/triangular bar, push type or thread type including rubber washers for 1.5/2.0 KW .
Supply only MLD hot & cold water PVC geyser connection pipe with ss nut, 450mm.
S&F in repairs stop valve 15 mm dia cast copper alloy chromium plated with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as directed.
S&F in repairs bib taps 15 mm dia cast copper alloy chromium plated, fancy type with crutch or butter fly handles screwed down for iron pipe or for brass ferrule complete all as directed.
S&F GI tubing 15 mm bore, medium grade with all fittings such as bends, elbows, nipples, sockets, tees, unions, short pieces etc. and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground & earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth lead wire 4.0 mm dia , by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 15mm bore from earthing test point or main controling switch as directed including providing funnel with 20mm bore GI pipe medium grade, wire mesh,charcoal or coke and common salt in alternative layer of 15 Cm (compacted thickness) all round the earth electrode,concrete earth pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 50mm thick cover of RCC (1:2:4) (re-inforced with 8mm dia TMT bar @15 cm C/C bothways and MS bar handle made of 10mm dia bar) including necessary earth work in excavation,returning in, filling and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 3 of MES Schedule Part-I including earthing pit cover etc. complete all as specified and directed.
Supply and fix in repair exhaust fan louvers shutter suitable for 230mm/300mm sweep fan opening, complete all as specified and directed.
Supply and fix in repair Stepped type electronic fan regulator, AC 50 HZ, 230V,100 Watts, minimum 4 steps (ISI Marked), complete all as specified and directed.
Supply and fix in repair modular fan step regulator, 100 Watts, 2 module, complete all as specified and directed.
Supply and fix in repair Switch piano flush button single pole, one way 5 Amp, complete all as specified and directed.
Supply and fix in repair modular switch 1 way 6 A, 1 module , complete all as specified and directed
Goswami Traders
M/S RAKHAL KANTI NAG
M/S ANITA ROY and SONS
Niranjan Roy
M/S Goutam Chakraborty
Anup Kumar Paul Choudhury
Shri Jyotibrata Chakrobarty
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .