Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.0 LAccepted-AOC 101 ANUPAM APARTMENTS M B ROAD NEW DELHI DELHI 110068 | SOUTH DELHI | DELHI | 110068 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹68.0 L+₹1.0 L (1.50%)Rejected-Finance | L2 | Rejected-Finance L2 Bidder |
| Sl No | Description | Qty | Unit | Inficold India Pvt Ltd L2 | Pluss Advanced Technologies Limited L1 |
|---|---|---|---|---|---|
| 1.00Mechanical work | |||||
| 1.00 | OD10044/2024-2025:Supply , Installation , testing and commissioning of thermal energy storage for dual chambers cold storage unit with independent temperature set points and doors of total internal volume equals to 1500 CFT (One 1000 CFT chamber and second 500 CFT chamber), phase change material, and solar condensing unit copper tube & aluminium fin, 350 MJ thermal storage capacity, 1500 kg phase change material , thermal storage is kept outside the cold room , entire capacity of thermal storage is accessible to either chamber, completely stops providing cooling in the storage when not required, and solar condensing unit | 2 | set | 16,75,000 ₹33,50,000 | 16,39,800 ₹32,79,600 Lowest |
| 1.00 | OD10046/2024-2025:Supply , Installation , testing and commissioning of modular PUF panel cold room with three doors and waterproofing, minimum 120 +/- 2mm thick PUF of density 40 +/- 2 kg/m3 and 0.4 mm SS 304 sheet on both sides, floor insulation 80 mm PUF + Kota stone flooring , door type with minimum opening of 6 feet x 3 feet . 120 mm PUF and .4 mm SS 304 sheets on both sides, heavy duty hinges, inbuilt lock . | 2 | set | 7,50,000 ₹15,00,000 Lowest | 7,74,000 ₹15,48,000 |
| 1.00 | OD10045/2024-2025:Supply , Installation , testing and commissioning of Evaporator units SS 304 sheet metal, copper tube & aluminium fin, Evaporator fan airflow, total 3000 CFM , one 1000 CFT chamber has 2000 CFM airflow and second 500 CFT chamber has 1000 CFM airflow, brushless axial fans for evaporator and condenser ,pumps, hose pipes, and drain pipe. Storage temperature range -4 to 4 Degree Celcius | 2 | set | 1,00,000 ₹2,00,000 Lowest | 1,02,600 ₹2,05,200 |
| 1.00 | OD10043/2024-2025:Supply , Installation , testing and commissioning of Electrical control panel , solar controller for compressor, remote monitoring system | 2 | set | 1,40,000 ₹2,80,000 Lowest | 1,44,500 ₹2,89,000 |
| 1.00 | OD10048/2024-2025:Supply , Installation , testing and commissioning of Solar panels 15 KWP, monocrystalline , make Vikram/Jakson /Waaree, Electrical battery capacity 6 x12 V 200 Ah, make Exide/ Amron/Okaya, Electrical battery type solar tubular lead acid, C10 discharge rating , Galvanized iron structure, rated for 150 KMph wind load solar structure, 3 phase, 440 VAC , 8 KVA , automatic change over alternate power supply, all solar panels are accessible to power compressor or electrical battery solar configuration . | 2 | set | 4,71,550 ₹9,43,100 | 4,54,500 ₹9,09,000 Lowest |
| 1.01 | OD10047/2024-2025:Supply , Installation , testing and commissioning of Electrical battery inverter and solar change controller | 2 | set | 1,10,000 ₹2,20,000 | 99,000 ₹1,98,000 Lowest |
| 2.00Civil work-Foundation | |||||
| 2.00 | 2.7.1:Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock | 27.5 | cum | 140 ₹3,849.72 | 117 ₹3,217.27 Lowest |
| 2.00 | 60.7.1:DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site | 27.5 | cum | 700 ₹19,248.6 | 621 ₹17,076.26 Lowest |
Tender Value
₹68.6 L
EMD Value
₹50,000
Closing Date
4 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer Electrical HEED Harbour Eng
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram, TVPM
PMMSY_Supply and Installation of 2 numbers of 10 MT Dual Chamber Fish Solar Cold Storage at Koyilandy Fishing Harbour_General Civil Work_General Civil Work
2025_HED_779035_1
HED/CEHED/TR/97/2025_5_1_1/1
Open Tender
Civil Works - Others
Item Rate
90 days
Koyilandy fishing harbour
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
Yes
31 Oct 2026
25 Jul 2025
6 Aug 2025
25 Jul 2025
4 Aug 2025
25 Jul 2025
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1276035.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .