Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance SECOND FLOOR KRISHNAKRIPA ARCADE PADIVATTOM EDAPALLY ERNAKULAM KOCHI ERNAKULAM KERALA 682024 | ERNAKULAM | KERALA | 682024 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹6.4 L
EMD Value
₹16,500
Closing Date
27 Nov 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHIEF ENGINEER, KSCADC
KSCADC Building, Kamalewsaram , Manacaud P.O. Thiruvananthapuram Pin-695009
Fisheries Neyyar -Renovation of Ornamental Hub No 1 to 6 and additional facilities in GIFT Hatchery - Blower erection and associated works-General Electrical Work(Re-tender2)
2025_SCADC_779887_3
ET-38/2025-26
Open Tender
Electrical Works
Item Rate
75 days
Neyyar Dam In Thiruvananthapuram -District
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,360
₹16,500
15 Nov 2025
6 Nov 2025
29 Nov 2025
6 Nov 2025
27 Nov 2025
6 Nov 2025
Amount
Conduit laying and associated works
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.5 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.50 mm
Wiring and accessories
1.10.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.10.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.56 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
90.14.28.2 S & F Motor starters of the following ratingsThree phase DOL starters for 0.25HP to 7.5 HP motor
Fittings and installations
90.4.1 Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
OD67958/2024-2025 Supply and installation of 9w LED bulb having 900lm or higher (Make:Philips/Wipro/Kesselec or any equivalent spec PWD/KSCADC approved make)
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.
90.15.4.5 Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD67956/2024-2025 Supply and fixing of bulk-head light fittings of the reputed company make, with clear/frosted glass cover, 10-Watt LED Bulkhead, Lumen : 850 Lm, Power : 10 W, Color Temperature : 6500 K, IP-65 rating, similar to Bajaj Ivora 10-Watt LED Bulkhead. (Make: Bajaj/Philips/Havells/wipro/Crompton
OD67955/2024-2025 Supply, installation, testing, and commissioning of the following sweep ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 3-core flexible Copper round cable, etc. as required. (a) 1200 mm sweep ceiling fan with steppedtype electronic fan regulator, brand approved by the engineer in charge
OD67959/2024-2025 Supply, installation, testing, and commissioning of 1200mm 20w LED tube light fitting.
OD1633/2025-2026 Supply, installation, testing, and commissioning of cast-iron, 3-phase, 5hp(3.7kW), 4-pole TEFC(Totally enclosed fan cooled) squirrel cage induction motor of the following specification. Frame size:112M, rated speed:1445 rpm, PF>=0.82, Rated current(IN)at 415V : 7.09A. including all mounting accessories as required. (Make: Lubi/ABB/Siemens) (Ref model Lubi)
OD1634/2025-2026 Supply, installation, testing, and commissioning of cast-iron, 3-phase, 3hp(2.2kW), 4- pole TEFC(Totally enclosed fan cooled) squirrel cage induction motor of the following specification. Frame size:100L, rated speed:1440 rpm, PF>=0.81, Rated current(IN)at 415V : 4.37A. including all mounting accessories as required. (Make: Lubi/ABB/Siemens) (Ref model Lubi)
OD1666/2025-2026 Supply, installation, testing, and commissioning of horizontal orientation flow blowers of the specification as follows. capacity greater than 250m3/hr, AIR COOLED PRESSURE: 0.2kg/cm2 to 0.7kg/cm2, 1200 rpm, Indoor, horizontal mounting type, including all mounting accessories as required.(Make: A1/Everest/KAY )(Reference model : A1-53.
OD1667/2025-2026 Supply, installation, testing, and commissioning of horizontal orientation flow blowers of the specification as follows. capacity greater than 160m3/hr, AIR COOLED PRESSURE: 0.2kg/cm2 to 0.7kg/cm2, 1200 rpm, Indoor, horizontal mounting type, including all mounting accessories as required.(Make: A1/Everest/KAY) (Reference model :A1-44)
Cabling and accessories
90.12.6.1 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.2 core 4 sq mm
90.12.7.1 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp
90.12.7.38 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp
90.12.6.38 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 4 sq mm
90.12.6.41 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 16 sq mm
90.12.7.41 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
OD67968/2024-2025 Supply and installation of 4 sq mm to 16 sq mm. 60 mm long x 12 mm wide x 1 mm thick Copper earthing clips for single compression glands and giving all connections.
OD29239/2025-2026 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 4 sq. mm (19mm)
OD29248/2025-2026 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 4 sq. mm (19mm)
9.1.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
Earthing and associated works
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.1.1 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.5.1 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
OD67962/2024-2025 Supply and fixing of copper bench including necessary hole drilling and provision to connect earthing conductors. 20mm x 3 mm Cu tape completing with all respects as required.
OD67963/2024-2025 Supply and fixing of copper earthing test joint including necessary hole drilling and provision to connect earthing conductors. 20mm x 3 mm Cu tape completing with all respects as required.
90.16.1.9 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.64 mm GI conductor (12 SWG)
90.16.5.2 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
DB and accessories
90.11.1.15 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.4 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.3.1 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
OD3148/2025-2026 Supply, installation testing and commissioning of SMC junction box of size 140mm x 140mm x 95mm (minimum) along with double pole, 240 volts, 40A isolator including connections as per standard.
LT Panel board and accessories
OD3129/2025-2026 Supply, installation, testing, and commissioning of SMC type 3 phase energy meter chamber of the following specification. minimum size 700mm x 480mm x 210mm(Length x Width x Depth), suitable to install 3ph energy meter, 3 nos of existing HRC fuses, 1 no of existing neutral link, 1 no of existing 4P MCB type isolator etc as required. Including all mounting accessories.
90.14.5 Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD67966/2024-2025 Supply and installation of 32A, HRC Fuse Base with HRC Fuse link in the existing enclosure and giving all necessary connections.
OD67964/2024-2025 Supply and installation of 32A, 2 Way neutral links mounted on DMC/SMC base in the existing enclosure and giving all necessary connections
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Bidder Name
SQ Engineering Contractors Pvt. Ltd
finance_1374269.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
Materiallist.pdf
Other Document • 0.01 MB
TD381125.pdf
Tender Documents • 3.59 MB
BOQ_1374269.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .