Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC LAIYO CHOWK RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 825325 | L1 | Accepted-AOC SINCE L1 | |
| 2 | L2₹5.0 L+₹31,558.60 (6.72%)Rejected-Finance KUNDA DIST BOKARO 829112 | KUNDA | BOKARO | JHARKHAND | 829112 | L2 | Rejected-Finance SINCE L2 | |
| 3 | Rejected-Technical AT JHARKHAND 15 NO KEDLA DIST RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 825101 | - | Rejected-Technical All documents are not as per NIT. |
| Sl No | Description | Qty | Unit | MOHANLAL SAO L1 | M/s Kamrul Construction L2 |
|---|---|---|---|---|---|
| 2.00 | Erection of steel tubular or rail pole strut incementconcrete1:3:6(1cement: 3coarsesand:6gradedstoneaggregate40mmnominal size) foundation includingexcavationandrefillingandsecuredwithholdingclamps,bolts,nuts, etc. as required. | 2 | nos | 6,500 ₹13,000 Lowest | 6,500 ₹13,000 Lowest |
| 3.00 | Supplying and erection of galvanised stay set for 11 KV over head lines
completewith19/20mmdiaX 1.8metres long stayrod,anchorplateof
size45cmX45cmX7.5mmthick, thimble, stayclamps, turnbuckle(20
mmX600mm),7/4.00mmdiaG.I. staywire and11 KVstrain insulator
etc in cement concrete1:3:6 (1cement : 3coarsesand : 6gradedstone
aggregate40mmnominal size) foundation includingexcavationandrefilling
etc. as required. | 12 | Set | 4,800 ₹57,600 | 4,600 ₹55,200 Lowest |
| 4.00 | Supplying and making outdoor cable end termination with heat
shrinkablejointingkit completewithall accessories includinglugssuitablefor
following size of3 core, XLPE aluminiumconductorcableof11KVgradeas
required:70 sq. mm | 4 | nos | 16,500 ₹66,000 Lowest | 17,136.15 ₹68,544.6 |
| 5.00 | LayingofonenumberPVCinsulatedand PVCsheathed/XLPEpower cable of
11 KV grade of following size direct in groundincluding excavation, sand
cushioning, protective covering and refilling the trench etc as required.Upto 120 sq. mm | 50 | mtr | 400 ₹20,000 Lowest | 400 ₹20,000 Lowest |
| 6.00 | Supplyinganderectionof11KVpininsulatorcompletewithlargesteelhead G.I. pin, nuts, washers etc. as required. | 33 | set | 320 ₹10,560 | 249 ₹8,217 Lowest |
| 7.00 | Supplyinganderectionof11KVdisc insulator for11KVoverheadlines with
galvanised insulator fittings, ball and socket type and complete with
galvanised strain clamps, bolts, nuts, washers etc. as required. | 18 | nos | 900 ₹16,200 | 818 ₹14,724 Lowest |
| 8.00 | Supplyingofchannel iron75mmX40mmX6mm(7.14kgpermetre)cross
armfortwo11KVoverheadlineconductorscompletewith50mmX50mmX 6mm(angleironbracketweldedtothechannel ironandcompletewith50mm
X 6mmM.S. flat iron clamps, bolts and nuts including drilling holes for
insulatorpins,bolts,nutsandwashersetc(asperdrawing)andpaintingwith
primer and finish paint as required. | 2 | nos | 2,200 ₹4,400 | 1,924 ₹3,848 Lowest |
| 9.00 | Supplyingoftwolengthsofchannel iron75mmX40mmX6mm(7.14kgper
metre)doublepolecrossarmfor threewire11KVoverhead line conductors
complete with through bolts and nuts forclampingtothepoles,50mmX
6mmM.S. flatsweldedononesidetothechannel ironandwithboltsandnuts
ontheothersidefortyingthecrossarmstogether, includingdrillingholesfor
insulator pins/ fittings, bolts, nuts andwashers etc (as per drawing) and
painting with primer and finish paint as required | 2 | set | 4,500 ₹9,000 | 4,158 ₹8,316 Lowest |
| 10.00 | Erectionofpoletop/straight twowire/Vshapetwowire,angle iron/channel
iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required. | 3 | nos | 420 ₹1,260 | 409 ₹1,227 Lowest |
| 11.00 | Erection of ACSR conductor of 7/3.35mmto 7/4.00 diameter and above including binding etc. as required. | 744 | kg | 210 ₹1,56,240 | 193 ₹1,43,592 Lowest |
Tender Value
Refer Docs
EMD Value
₹6,500
Closing Date
24 Jul 2025, 6:55 pmClosed
SO(ENM)
GM UNIT KUJU
Maintenance of 11KV Overhead line from 33KV/11KV Murpa substation to Kuju Substation at Kuju Project.
2025_CCL_339596_1
GM (K)/EnM/eTender/25-26/99
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
GM UNIT KUJU
2 documents required · 2 mandatory
₹6,500
10 Oct 2025
14 Jul 2025
25 Jul 2025
14 Jul 2025
24 Jul 2025
14 Jul 2025
14 Jul 2025 - 21 Jul 2025
Amount
Erection of steel tubular or rail pole strut incementconcrete1:3:6(1cement: 3coarsesand:6gradedstoneaggregate40mmnominal size) foundation includingexcavationandrefillingandsecuredwithholdingclamps,bolts,nuts, etc. as required.
Supplying and erection of galvanised stay set for 11 KV over head lines completewith19/20mmdiaX 1.8metres long stayrod,anchorplateof size45cmX45cmX7.5mmthick, thimble, stayclamps, turnbuckle(20 mmX600mm),7/4.00mmdiaG.I. staywire and11 KVstrain insulator etc in cement concrete1:3:6 (1cement : 3coarsesand : 6gradedstone aggregate40mmnominal size) foundation includingexcavationandrefilling etc. as required.
Supplying and making outdoor cable end termination with heat shrinkablejointingkit completewithall accessories includinglugssuitablefor following size of3 core, XLPE aluminiumconductorcableof11KVgradeas required:70 sq. mm
LayingofonenumberPVCinsulatedand PVCsheathed/XLPEpower cable of 11 KV grade of following size direct in groundincluding excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 120 sq. mm
Supplyinganderectionof11KVpininsulatorcompletewithlargesteelhead G.I. pin, nuts, washers etc. as required.
Supplyinganderectionof11KVdisc insulator for11KVoverheadlines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplyingofchannel iron75mmX40mmX6mm(7.14kgpermetre)cross armfortwo11KVoverheadlineconductorscompletewith50mmX50mmX 6mm(angleironbracketweldedtothechannel ironandcompletewith50mm X 6mmM.S. flat iron clamps, bolts and nuts including drilling holes for insulatorpins,bolts,nutsandwashersetc(asperdrawing)andpaintingwith primer and finish paint as required.
Supplyingoftwolengthsofchannel iron75mmX40mmX6mm(7.14kgper metre)doublepolecrossarmfor threewire11KVoverhead line conductors complete with through bolts and nuts forclampingtothepoles,50mmX 6mmM.S. flatsweldedononesidetothechannel ironandwithboltsandnuts ontheothersidefortyingthecrossarmstogether, includingdrillingholesfor insulator pins/ fittings, bolts, nuts andwashers etc (as per drawing) and painting with primer and finish paint as required
Erectionofpoletop/straight twowire/Vshapetwowire,angle iron/channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Erection of ACSR conductor of 7/3.35mmto 7/4.00 diameter and above including binding etc. as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3wire, 11KVoverhead lineswith ratedvoltage9KV (rms)withanominal discharge current ratingof 5KAand complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supply and erection of approved make safe earthing electrode consisting pipe-in pipe technology as per IS 3043-1987 made of corrosion free G.I. pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free earthing in earth pit of minimum bore dia. 150mm size, as mentioned below : With 3 metre G.I. pipes having outer pipe dia of 50mm having 80-200 micron galvanizing, Inner pipe dia. of 25mm having 200-250 Micron galvanizing, connection terminal dia. of 12mm in nominal soil with 50 kg (two bag) back filling bentonite compound UL listed and confirm to relevant International/Indian standards around electrode upto ground level.
Dismantlingofpole/street lightstandard/strutembeddedincementconcrete foundation etc. as required.
Dismantlingof over head lines comprisingof copper/ aluminiumover head conductor, Cl. wire, cross arms, insulators etc. as required.
Total impact of GST for the purpose of CTC
M/s Kamrul Construction (BID ID -1169337)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .