Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹6.7 L+₹40,693.28 (6.52%)Rejected-Finance | L2 | Rejected-Finance Rejected Being L2 | |
| 3 | L3₹6.8 L+₹55,028.63 (8.81%)Rejected-Finance | L3 | Rejected-Finance Rejected Being L3 | |
| 4 | L4₹7.2 L+₹96,121.58 (15.4%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L4 | Rejected-Finance Rejected Being L4 | |
| 5 | L5₹8.7 L+₹2.5 L (40.0%)Rejected-Finance | L5 | Rejected-Finance Rejected Being L5 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
15 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Leh
GE (AF) Leh c/o 56APO
CERTAIN REPAIR MAINTENANCE OF EXTERNAL E/M SERVICESS INCLUDING SECURITY LIGHTS AT AF DETT KARGIL UNDER GE (AF) LEH
2023_MES_589630_1
8427/GE(AF)/LEH/T-15/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Leh
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Leh
₹20,000
Yes
28 Jun 2023
15 Apr 2023
18 May 2023
15 Apr 2023
15 May 2023
1 May 2023
Amount
Excavation in trenches not exc 1.5m wide and and not exc. 1.5m depth wide in any type of soil for laying electric cables/pipes etc including getting out excavated earth and trimming the sides and bottoms of trenches , complete all as specificed and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
Sand cushioning to under ground cable with clean dry sand locally available with layer of sand 8cm thick before laying of cable and 15 cm after laying of cable, complete all as specified and directed by Engineer-in-Charge. Note- For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR Part-I.
Factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other in and including taking down old unservicable cable cover, complete all as specificed and directed by Engineer-in-Charge.
LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 150 sqmm cross sectional area, 3.5 core ,laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers including jointing and testing complete and taking out unserviceable cable , complete all as specified and directed by Engineer-in- Charge. Note : Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 6 here-in-beforee but size 95 sqmm 3.5 core.
All as per item No 6 here-in-beforee but size 35 Sqmm 3.5 core
All as per item No 6 here-in-beforee but size 16 sqmm 4 core.
All as per item No 6 here-in-beforee but size 10 sqmm 2 core.
All as per item No 6 here-in-beforee but size 6 Sqmm 2 core.
Cutting existing road/PCC hard standing/pavement for laying of under ground cable/GI tubing and making good to match with the existing surface with PCC 1:2:4 Type C-1 using 20mm graded stone aggregates including all excuation and earth work , complete all as specified and directed by Engineer-in- Charge. Note:- Only PCC shall be measured and paid separately.
Mild steel galvanized tubes light grade ISI marked 50mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe ,compllete all as specified and as directed by Engineer-in-Charge.
Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, final, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint including dismantling of existing old damage PCC pole/ steel pole of any description , complete all as specified and as directed by Engineer in charge. Note :Cost of Transportation of Pole at location shall deemed to be included in the rate quoted by contractor against this item and nothing extra shall be admissible on this account .
Taking down carefully U/S street light from poles / building any type and size after disconnecting the electrical connections for carrying out necessary repairs if found repairable and refixed in the same location after repair. (Rate including carrying to MES store if accessories or component found unserviceable), complete all as specified and directed by Engineer-in- Charge.
PVC insulated round sheathed industrial cable of size 1.5 Sqmm 2 core multi-stranded copper conductorfor connecting junction box to street light fitting in and including old unservicable cable , complete all as specified and directed by Engineer-in- Charge.
PVC conduit medium grade 25mm thick for running 2 core cable from junction box to street / flood light fitting including necessary fixing arrangement such as MS clamp of suitable size complete with nuts and bolts in and including taking down old unservicable conduit , complete all as specified and directed by Engineer-in- Charge.
Electronic drivers suitable for LED street light fitting of capacity 45/60 Watt as in replacment , complete all as specified and directed by Engineer-in- Charge.
Street light bracket fitting made out of 40mm dia GI pipe light grade tubing 1.2 mtr long bent to required shape including 02 Nos of MS clamp of size 450x50x5mm flat duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer and fixed to pole / walls etc fixed in and including taking down old unservicable bracket , complete all as specified and directed by Engineer-in- Charge.
LED street light fittings high power energy saving luminaire, with system wattage 60 watt with system efficacy (lm/w) not less than 90 lumens per watt, total system lumen not less than 5400 lumens, PF not less than 0.95, high pressure die cast aluminium alloy LM6 housing heat sink for better heat transmission with epoxy powder coated IP-65 class 1 protection, toughened glass/UV stabilized polycarbonate cover, well designed thermal management system in and including taking down old unsv street light bracket fitting ,complete all as specified and directed by Engineer-in- Charge.
Thermoplastic cable junction boxes IP 55/65 with metric knockout for cable entry of size 200 x160x 98 mm fixing on pole / wall with MS clamps / MS flat iron ( as per site requirement) of size 25x4mm , nuts bolts and washer and glands, including one No of MCB SP 6 Amps in and including taking down old unserviceable boxes , complete all as specified and directed by Engineer-in- Charge.
MCB SP 6 to 32 Amps - 10KA 240 Volts as in replacment, complete all as specified and directed by Engineer-in- Charge.
Plain cement concrete ,1:3:6, type C-1, using 20 mm graded mechanically crushed stone aggregates for coping around pole,including necessary form work finished the surface even and smooth without using extra cemrnt where coping of pole are dameged, complete all as specified and as directed by Engineer-in- Charge.
Plain cement concrete 1:4:8, type D-2, using 40 mm graded mechanically crushed stone aggregates as in foundations of pole and filling of mass concrete, complete all as specified and directed by the Engineer in Charge.
Preparation of old painted surfaces by scraping, scretching and cleaning the old painted surface and painting of LT steel tubular pole 9 mtrs long from bottam to top with aluminium paint and painting to bottam up to 1.5 mtr height from top of PCC coping with sysnthetic enamel paint 2 coats in black and Yellow/white strip 30 cm apart alternatively including numbering in 8 cm height of number with white paint both paint aluminium /synthetic duly approved ,complete all as specified and as directed by Engineer-in-Charge .
Earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 25x4mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 5 of SSR Part-I and testing ,including dismanteling of old unserviceable earthing , complete all as specified and as directed by Engineer-in-Charge. Note : (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 1.00 metre away from earth.
Bus bar chamber factory made (CPRI approved), outdoor type (kiosk), floor mounted, compartment type, dust and vermin proof (IP-55 protection) suitable for 415 volts grade, 3 phase, 4wire 50Hz AC supply with electrolytic grade aluminum strip with heat shrink cable sleeves with colour code supported on epoxy resin based insulator 4 strips of suitable length for current rating 200 A , colour coded & sleeved, fabricated out of 3.15mm thick mild steel CRCA sheet mounted on 50mmx50mmx6mm angle iron frame and welded to 75cm long 50mmx50mmx6mm size angle iron legs (04 Nos), front & rear openable, with front hinged door inclusive locking arrangement with provision of all incoming/outgoing cable entries alongwith suitable size double compression type cable glands and adopter boxes for incoming and outgoing cable & spray painting with two coats of first quality super enameled grey paint over and including a coat of red oxide primer, including anti-corrosive treatment (7 tank), legs grouted in floor in PCC (1:2:4) bed block of size 30cmx30cmx60cm, in and including taking down of old unserviceable Bus bar , complete all as specified and as directed by Engineer-in-Charge.
MCCB FP current rating 320 Amps 36 KA adjustable thermal and fixed magnetic , 415 Volts AC, 50 Hz, including connecting with existing system and cabling network and making good disturbed surfaces, testing in and including taking out unserviceable MCCB , complete all as specified and directed by Engineer-in-Charge.
MCCB FP current rating 200 Amps 25 KA adjustable thermal and fixed magnetic , 415 Volts AC, 50 Hz, including connecting with existing system and cabling network and making good disturbed surfaces, testing in and including taking out unserviceable MCCB , complete all as specified and directed by Engineer-in-Charge.
MCCB FP current rating 160 Amps 25 KA adjustable thermal and fixed magnetic , 415 Volts AC, 50 Hz, including connecting with existing system and cabling network and making good disturbed surfaces, testing in and including taking out unserviceable MCCB , complete all as specified and directed by Engineer-in-Charge.
MCCB three pole 415 V AC, current rating 100 amps, breaking cap 25 KA adjustable thermal and fixed magnetic , including connecting with existing system and cabling network and making good disturbed surfaces, testing in and including taking out unserviceable MCCB , complete all as specified and directed by Engineer-in-Charge.
MCCB three pole 415 V AC, current rating 63 amps, breaking cap 25 KA adjustable thermal and fixed magnetic , including connecting with existing system and cabling network and making good disturbed surfaces, testing in and including taking out unserviceable MCCB , complete all as specified and directed by Engineer-in-Charge.
Cable jointing kit for 1.1 KV grade cable for indoor/outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, Al conductor cable of size 25 to 50 Sqmm, complete all as specified and directed by Engineer-in-Charge.
Cable jointing kit for 1.1 KV grade cable for indoor/outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, Al conductor cable of size 70 to 120 Sqmm, complete all as specified and directed by Engineer-in-Charge.
Cable jointing kit for 1.1 KV grade cable for indoor/outdoor termination , heat shrink type, joint complete with jointing material and accessories suitable for 3.5/4 core XLPE, armoured, Al conductor cable of size 150 to 185 Sqmm, complete all as specified and directed by Engineer-in-Charge.
Steel water tubing, 20 mm bore medium grade, galvanized with all fittings ( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc) and fixed complete to walls, ceiling or laid in floors in and including taking up or down steel water tubing and connections ,complete all as specified and directed by Engineer-in- Charge.
All as per Item 37 here-in-before but 25 mm dia
All as per Item 37 here-in-before but 40mm dia
All as per Item 37 here-in-before but 50mm dia
Gun-metal, globe or gate valves, 20 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked) as in replacment, complete all as specified and directed by Engineer-in- Charge.
All as per Item 41 here-in-before but 25 mm dia
All as per Item 41 here-in-before but 40mm dia
All as per Item 41 here-in-before but 50mm dia
GI elbow of 20mm dia as in replacment, complete all as specified and directed by Engineer-in- Charge.
All as per Item 45 here-in-before but 25 mm dia
All as per Item 45 here-in-before but 40mm dia
All as per Item 45 here-in-before but 50mm dia
GI Tee 20 mm dia as in replacment, complete all as specified and directed by Engineer-in- Charge.
All as per Item 49 here-in-before but 25 mm dia
All as per Item 49 here-in-before but 40mm dia
All as per Item 49 here-in-before but 50mm dia
GI Socket 20 mm dia as in replacment, complete all as specified and directed by Engineer-in- Charge.
All as per Item 53 here-in-before but 25 mm dia
All as per Item 53 here-in-before but 40mm dia
All as per Item 53 here-in-before but 50mm dia
GI Union 20 mm dia as in replacment, complete all as specified and directed by Engineer-in- Charge.
All as per Item 56 here-in-before but 25 mm dia
All as per Item 56 here-in-before but 40 mm dia
All as per Item 56 here-in-before but 50 mm dia
GI Nipple 20 mm dia as in replacment, complete all as specified and directed by Engineer-in- Charge.
All as per Item 61 here-in-before but 25 mm dia
All as per Item 61 here-in-before but 40 mm dia
All as per Item 61 here-in-before but 50 mm dia
Brass valves, high pressure, with polythene float and fly nut ,20mm dia , screwed for iron pipes or brass ferrule and fixed in PVC OHT tanks as in replacment ,complete all as specified and directed by Engineer-in- Charge.
All as per Item 65 here-in-before but 25 mm dia
Note : Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents.
M/s Raj Construction
osho traders
SUMEET TRADING CORPORATION
Hitech Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .