Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance 212 338 OLD DALANWALA DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
26 Aug 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DY. CHIEF ENGINEER(PD AND EP)
O/O ELECTRICAL PROJECTS, 2ND FLOOR, SARATHI BUILDING, NFC HYDERABAD
MISCELLANEOUS ELECTRICAL WORKS AT CONTROL LAB BUILDING AT NFC HYDERABAD
2024_NFC_819601_1
EP/ELE/04/2024
Open Tender
Electrical Works
Works
120 days
NFC HYDERABAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹70,000
30 Aug 2024
2 Aug 2024
30 Aug 2024
2 Aug 2024
26 Aug 2024
17 Aug 2024
Amount
Installation, testing and commissioning of following 415V TPN type tested Power Distribution Boards as per instructions mentioned in technical specifications.
PDB-1 with 1000A ACB incomer with dimensions 3m x1m x2.4m
PDB-2 with 400A MCCB incomer with dimensions 1.5m x0.6m x2.4m
PDB-3 with 250A MCCB incomer with dimensions 1.5m x0.5m x1.8m
PDB-4 with 250A MCCB incomer with dimensions 1.5m x0.5m x2.4m
PDB-5 with 400A MCCB incomer with dimensions 1.5m x0.5m x2.2m
PDB-6 with 400A MCCB incomer with dimensions 1.5m x0.6m x2.4m
PDB-7 with 400A MCCB incomer with dimensions 1.5m x0.6m x2.2m
PDB-8, a wall mounted distribution board, with 100A MCCB incomer with dimensions 0.5m x0.25m x0.7m
PDB-9, a wall mounted distribution board, with 100A MCCB incomer with dimensions 0.5m x0.25m x0.7m
Laying only of following sizes of 1.1 KV grade XLPE insulated, PVC extruded inner sheathed, armoured, FRLS PVC ST2 outersheathed cable on cable trays/trenches with all accessories
3.5 core 240 sqmm Al Cable
3.5 core 150 sqmm Al Cable
3.5 core 95 Sq.mm Al Cable
3.5 core 70 Sq.mm Al Cable
3.5 core 50 Sq.mm Al cable
4 core 25 Sq.mm Al cable
4 core 10 Sq.mm Cu cable
Supply and laying of following sizes of 1.1 KV grade XLPE insulated, 4 core 4 Sq.mm Cu Cable, PVC extruded inner sheathed, armoured, FRLS PVC ST2 outersheathed cable on cable trays/trenches with all accessories Make: KEC/ Torrent / RPG / KEI.
Supply
Installation
Providing end terminations for following sizes of 1.1 KV grade XLPE insulated and PVC sheathed armoured cables with required hard ware like heavy duty double compression cable glands, heavy duty long neck copper lugs etc complete Make of glands/ Lugs: Dowells/Jainson/Hex/Comet/Connectwell/Braco
3.5 core 240 sqmm Al Cable
3.5 core 150 sqmm Al Cable
3.5 core 95 Sq.mm Al Cable
3.5 core 70 Sq.mm Al Cable
3.5 core 50 Sq.mm Al cable
4 core 25 Sq.mm Al cable
4 core 10 Sq.mm Cu cable
4 core 4 Sq.mm Cu Cable
Installation only of 80W LED flood light fittings with supply of required junction boxes, fixing accessories like supporting hard ware etc as required to complete the installation in all respects
Installation only of vertical model double door TPN Distribution boards of following sizes
8 way TPN MCCB DB with following components. a. 100 A TPN MCCB with earth fault release and adjustible settings - 1 No Incomer b. 32 A TP MCB - 1 Nos c. 25 A SP MCB - 9 Nos d. 16A SP MCB -12 Nos
8 way TPN MCB DB with following components. a. 63 A 300mA RCBO - 1 No Incomer b. 25 A SP MCB - 4 Nos c. 16 A SP MCB - 8 Nos d. 10A SP MCB - 12 Nos
Installation of following industrial plug and sockets of following sizes
32 A 3 pole & Earth Metal clad power socket with 32 A TP MCB control including plug top
20 A 2pole & Earth Metal clad power socket with 25 A SP MCB control including plug top
Installation only of 2 Pole MCB enclosure box fitted with 32A DP MCB.
Installation only of 2 Pole MCB enclosure box fitted with 63A DP MCB.
SITC of 3Phase 10hp DOL starter module with 32A SDFU with Motor protection relay similar to L&T MPR300 with earth fault protection, R,Y,B indication lamps and ON/OFF TRIP indication lamps. Makes: L&T/ Schneider/ Siemens
Supply
Installation
Fixing only of 1200mm sweep ceiling fans with BEE 5 star rating with required downrods and all other accesories.
Fixing only of following single phase heavy duty industrial exhaust fans with all required accessories, junction boxes etc
600 mm dia exhaust fans
450 mm dia exhaust fans
300 mm dia exhaust fans
Supply and installation of following accesories for already installed Legrand make 105 x 50 mm DLP plastic trunking system
Variable internal angle
Variable external angle
T joint
End cap
Flat angle
Flat junction / coupling
Supply and installation of following accesories for already installed Legrand make 32 x 20 mm DLP plastic trunking system
Variable internal angle
Variable external angle
T joint
End cap
Flat angle
Flat junction / coupling
EARTHING SYSTEM: MAINTENANCE FREE EARTHING SYSTEM : Supply,installation,testing & commissioning of maintenance free earthing system & associated works, etc. complete as per specifications & instructions of E-I-C. A. Providing and making earth station comprising of 17 mm dia 3m long earthing electrode of high tensile low carbon steel rod molecularly bonded 250 micron copper coating on the outer surface, UL listed, filling bore with suitable earth enhancement compound as per IEC 62561-7 & manufacturer's standard, surrounding the earth electrode complete with all required materials & instructions of EIC. Note: The scope includes :- 1) Installation of earth rods including making pit/ drilling suitable size bore holes in normal soil/ hard rock as per manufacturer's recommendations & design. 2) Exothermic welding of joints between earth electrode & GI / tinned Cu strip and between GI / tinned Cu strips, used for interconnection of earth electrodes. B. Providing & making concrete chamber (1:2:4) of size 600 x 600 x 600 mm (inside dimension) with 10 mm thick MS hinged cover mounted on 40 x 40 x 5 mm thick angle iron frame, 50 x 6 mm & 150 mm long GI equipotential bar mounted inside chamber as per instructions of EIC. (For housing Equipotential bar) Note: The date of testing and earth resistance value shall be written on the cover with black base with yellow paint. Make of earth pits: DEHN/OBO/ERICO/JEF
Supply and fixing of 50 x 6 mm hot dip galvanised GI strip for earthing by clamping on walls/trays/trench with all required accesories
Supply
Installation
Supply and fixing of 25 x 6 mm hot dip galvanised GI strip for earthing by clamping on walls/trays/trench with all required accesories
Supply
Installation
Supply and fixing of 25 x 3 mm hot dip galvanised GI strip for earthing by clamping on walls/trays/trench with all required accesories
Supply
Installation
Supply and fixing of hot dip galvanised 8 SWG GI wire for earthing
Supply
Installation
Suply and installation of structural steel like channels, angles etc for fabriaction and erection of cable trays supports, light fitting supports etc and painting of the same with red oxide and 2 coats of grey enamel paint. Rate should also include the required SS bolts and nuts for fixing of supports Make of Structural steel: TATA, Vizag Steel, Jindal Ispat, SAIL
Supply
Installation
Excavation and back filling in soft soil for laying of cables, consolidation, ramming, removal of excess earth, etc complete to bring back the surface to original finish.
Supply and laying of Cement concrete of M30 (PPC cement) to IS 1489 , using river sand and graded stone aggregates of 40mm maximum size for structural foundation, including centering and shuttering upto the required heights with MS Plates/plywood compacting, vibrating and curing upto the cut off level of column
Installation only of 150mm NP2 class hume pipes with required couplers for road crossing of cables
Supply and fixing of 100 mm X 25 mm anodised Aluminium cable tags engraved on black back ground with name of the load along with required hardware for fixing the lables on to the cables.
Supply and installation of panel front rubber mats of size 2 Mts x 1 Mts with 2 mm thick as per latest IS 15652:2006
Supply and fixing of HILTI fire resistance cement of 20kg bag at all wall openings made for cable crossings
Romoval of existing Panel boards of approx dimension 2000x1800x600mm and making good of the surface. The removed material should be shifted to an identified location about 500m away.
Removal of cables of about 240Sq.mm to 25sq.mm sizes and making good of the surface. The removed cables should be cut into 1m length pieces and shifted to an identified location about 500m away.
Removal of MS/PVC lighting Switchboards/ sockets, its associated wiring and making good of the surface. The removed material should be shifted to an identified location about 500m away
Removal of ceiling fans / exhaust fans / light fittings along with their down rods and other accessories and making good of the surface. The removed material should be shifted to an identified location about 500m away.
BHARATHI INDUSTRIAL CONTROLS
Modern Electric Company
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .