Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC Accepted for acceptance being lowest | |
| 2 | L2₹32.0 L+₹1.8 L (5.92%)Rejected-Finance | L2 | Rejected-Finance Not L1. | |
| 3 | L3₹34.7 L+₹4.5 L (14.8%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not L1. | |
| 4 | L4₹34.7 L+₹4.5 L (14.8%)Rejected-Finance | L4 | Rejected-Finance Not L1. |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
4 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jamnagar No.2
Air Force-II, Udhyog Nagar, Jamnagar - 361004
ADDN / ALTN TO BUILDING NO P-275 AND IMPROVEMENT TO ROOF OF CERTAIN MD ACCN AT AF STATION UNDER GE (AF) JAMNAGAR NO.2
2022_MES_556401_1
8383/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No.2
₹66,000
Yes
24 Nov 2022
7 Oct 2022
5 Nov 2022
7 Oct 2022
4 Nov 2022
21 Oct 2022
Amount
Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat, including removal of debries to outside MOD land complete all as specified and directed.
M & L for 25 mm thick cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in levelling course complete all as specified and directed.
M&L Non - skid joint free coloured Ceramic tiles (1st quality) not less than 7 mm thick of size exc 0.06 sqm but n exc 0.11 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over & including 15mm screed bed or bedding in CM 1:6 complete all as specified and directed.
M&L for Non-skid joint free coloured Ceramic tiles (1st quality) not less than 7mm thick tiles of size exc 0.11 sqm but n exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over & including 15mm screed bed or bedding in CM 1:6 complete all as specified and directed.
M&L for Non-skid joint free coloured Ceramic tiles (1st quality) not less than 7mm thick tiles of size exc 0.18 sqm but n exc 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over & including 15mm screed bed or bedding in CM 1:6 complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 350 x 250 x 7mm / 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat of mortar in CM 1:4 for laying wall tiles finishes complete all as specified and directed.
Dismantling of kota stone slabs and granite tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or plateform etc complete all as specified and directed.
M&L for Granite work 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in coloured cement (1:2) using marble dust with admixture of pigment to match with granite shade complete all as specified and directed.
M & L for machine cut & machine polished kota stone slab 18 to 20 mm thick as in kitchen plateform, treads of steps laid over and including 15 mm thick screed bed in CM 1:6, jointed with grey cement slurry mixed with colour pigment to match the shade of the slab, rubbing and polishing complete all as specified and directed.
M&L for 18 to 20mm thick machine cut kota stone slab in riser of steps, skirting,dado and pillar laid over cement mortar in 1:4 base laid and jointed with grewy cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for rounding to edges of Granite/ Kota stone slabs edge, such as in steps cooking plateform, and other similar situation complete all as specified and directed.
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, including removal of debries to a distance exc 1.5 Km but n. exc 2 Km. complete all as specified and directed.
M&L for rendering 10 mm thick in CM 1:6 on brick or stone walls to be finished even and smooth (without using extra lime or cement) complete all as specified and directed.
M&L for rendering 10 mm thick on concrete surface whilst the concrete is green, in cement mortar (1:4) finishing the surface even and smooth without using extra cement, including mixing only liquid water proofing compound as per manufacturer instruction complete all as specified and directed. Note: WPC will be measured & Paid separately.
M&L for 15 mm thick rendering in cement mortar 1:4 on stone / PCC block masonry wall surface, including mixing liquid water proofing compound in second layer only as per manufacturers instructions, finished the surface even & smooth without using extra cement complete all as specified and directed. Note:- WPC will be measured & paid separately.
M&L for 5 mm thick rendering in cement mortar 1:3 on on ceiling, finished the surface even & smooth without using extra cement complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls & applying two coat of Distemper oil emulsion over a coat of chalk whitening compatible primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coat of cement Base paint over a coat of primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparation of old distempered/ decorated surfaces of walls incl brooming down, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coats of distemper oil emulsion complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted of steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for repairing of chajja / roof projection / roof spout by taking down old plaster applying 10mm thick rendering in cement mortar 1:3 and finishing the surface even & smooth with out using extra cement and complete surface finish with two coats of exterior emulsion etc complete all as specified and directed.
M&L for repairing of chajja / roof projection by taking down old plaster, damaged concrete surface, cutting of exposed reinforcement and making good with 1:4 including admixture of SBR (cost of SBR including) as per manufacture, and provide reinft cement concrete 1:2:4 type B1 as required, necessary scafolding,formwork etc up to 9 Mtr heigh and applying 10 mm thick rendring in cement mortar 1:3 , finishing the surface even & smooth with out using extra cement complete all as specified and directed. Note : Reinft will be paid separately.
M&L for preparation of old decorated external surfaces of walls including brooming down, scrapping down, smoke soot, mould, moss and efflorence salt and trading oil and grease spouts and cleaning with water on wall applying one coat of Acrylic emulsion (Exterior weather coat) paint of any tint as per manufacturers instructions etc complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls and providing one coat of cement base paint complete all as specified and directed.
Removal of existing roof treatment consisting of screed bed, tar felts etc, and removal of debris outside MD land complete all as specified and directed.
Roughening of surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for plan cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate), in roof for padding to achieve the 1:40 slope complete all as specified and directed.
Material and labour for water proofing treatment by applying one coat of oil base bituminous primer @ 0.3 Kg / Sqm with brush / roller, laying of 3 mm thick APP based polymer modified membrane reinforced non-woven polyester, weight not less than 3.50 Kg / Sqm and sealing all the over laps 100 mm in length side and 100 mm in width side of membranes laid with torch application complete all as specified and directed.
Dismantling water tanks of capacity exc 250 and n.exc 500 ltrs and removing to store complete all as specified and directed.
Supply and fix 500 litres capacity, rotational moulded, polythene water storage tank (Cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with 25mm dia GI tank nipple of for inlet, outlet, washout and overflow etc complete all as specified and directed.
Disconnecting existing tanks exc 500 ltr and n exc 1000 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning repairing, etc. complete all as specified and directed.
Demolition of concrete surfaces in ground floor and paving n.exc. 15cm thickness (below or above ground level) and removing the same to a distance of 1.5 KM including loading and dumping / levelling at the destination complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:2:4 type B2 (using 40mm graded stone aggregate) as in floor/ hard standing etc all as specified finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 75mm thick plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth potection including finished the surface even and smooth without using of extra cement and complete all as specified and directed.
Taking down chowkats or frame with shutter (with out taking off shutter from the frame) n.exc 1.5 Sqm complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutter from the frame) .exc 1.5 Sqm and n. exc 4.0 sqm area of each complete all as specified and directed.
Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size etc all as specified below complete all as specified and directed. (a) Frame (top & side) section shall of size 101.60 x 44.75 x 2.4 mm (Section No 14021) (b) Vertical Members of shutter Section shall be be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter Section shall be be of size 83.50 x 44.45 x 2.00 mm (Section No 19581) (d) Lock rail (Middle member) of shutter Section shall be be of size 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter Section shall be be of size 150.00 x 44.45 x 3.10 mm (Section No 19584) (f) Glazing clip for securing glass of shutters shall be be of 0.80 mm thick (Section No 19370).
Supply fabricate & fix in position anodised aluminium powder coated (minimumthickness of powder coating 50 micron) three track window ( two shutters glazed ) with frame, glazed with 4 mm thick tinted glass and, wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in Member for wire gauge Section shall be 18.00 x 25.00 x 1.35 (Section No 20791). position, concelled type lock for all two shutter, PVC roller etc all as specified below, including taking down old window complete all as specified and directed. (a) Frame (top & side) section shall of size 92.00 x 31.75 x 1.50 mm (Section No 20831) (b) Frame (bottom) section shall of size 92.00 x 31.75 x 1.50 mm (Section No 20832) (c) Top & side Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55 (Section No 20738) (d) Shutter Interlock Section shall be be of size 18.00 x 40.00 x 1.45 (Section No 20737) (e) Bottom Members of shutter Section shall be be of size 18.00 x 40.00 x 1.55 (Section No 20736) Note:- Section No given above are of make Jidal, Contractor may use similar section of other make mention in Appx B.
S&F aluminium (powder coated with approved colour) ventilator, partialy glazed and partialy louvers, outer frame & mullion fabricated with aluminium section of size 82.50 mm x 38.00 mm x 1.70 mm thick (Cat No 20036), half portion glazed with 4 mm thick frosted glass including rubber beading, & glazing clip, half portaion louvers of 80 mm wide & 4 mm thick frosted glass including aluminium louver patti including S.S wire gauge of fixing of 0.36mm dia and 1.40 width of aparture with 25x3mm thick aluminium strip with screw to upper half portion of ventilator all fitting & fixture and fixed in position including taking down old ventilator complete all as specified and directed. Note:-(i) Section No given above are of make Jindal, Contractor may use similar section of other make mention in Appx B
S & F in repairs 20 mm dia Curtain rails, mild steel, chromium plated with fixing brackets / concealed brackets & holders, stops, rollers etc. decorative type complete all as specified and directed.
Dismantling wrought iron or mild steel or cast iron work of any description not otherwise provided for complete all as specified and directed.
M & L for framed work such as grills, gratings, etc. with ends of bars houldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L for hollow Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161:1979 grade St-240 complete all as specified and directed.
M&L for preparation of new surfaces of steel exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Demolition of reinforced cement concrete including removing the same to a distance of 1.5 KM including loading and dumping/ levelling at the destination complete all as specified and directed.
M&L for Pre cast Reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for manholes/soakage well and similar works supported on walls set in cement mortar 1:6 complete all as specified and directed. Note:- Reinforcement steel will be measured & paid separately.
M & L for mild steel TMT bars 10 mm dia, cut to length, bent to shape required including bending, and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping, benching and like including weathering, slightly round or chamfered angles and throating as directed and including necessary use and waste of formwork complete all as specified and directed.
Demolition of brick work/ stone work /PCC block masonry built in Cement mortar complete all as specified and directed.
M&L for Cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete complete all as specified and directed.
M&L for providing precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks exc 10 cm in width (with plain or inter locking joints as directed) setting in CM 1:6 complete in wall, pillars and similar works complete all as specified and directed.
Dismantling ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
M & L 4mm thick asbestos cement plain building boards, fixed to timber framework with screws complete all as specified and directed.
M & L 12mm Perforated particle board/ tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed.
S&F false ceiling with 12 mm thick of size 1.20m x 1.80m POP sheets fixed with machine screaws on and including GI channel 22 gauge thick grid work, main joints placed at 1.20m center to center, cross joints placed at 450mm centre to centre, hanging wiht 22 gauge GI strip suspenders from roof, 'J' hooks bolts and nuts etc and treating the POP sheets with thin layer of POP with gypsum anhydrous binder and prepare the surface till smooth surface is achieved and applying two coats of plastic paint of any pattern and design over a coat of primer on ceiling sheets all complete as required as per manufacture's instructions and as directed by the Engr-in-charge. Note : (a) Pattern and design shall be directed by Engr-in-charge during execution of work (b) The exposure surface of the false ceiling shall be joint less seen smooth to receive paint. (c) The POP sheets shall be fixed with suitable screws below the grid shall not be placed over the grid).
M & L decorative conrnices/moulding using POP of cross sectional dimension exc.25 Sqcm and n.exc 50 Sqcm as per pattern and design as approved and fixed in position including preparation of surfaces and applying two coats of plastic paint over primers match with the ceiling sheets complete all as specified and directed. Note : Pattern and desin shall be directed by Engr-in-Charge during execution of work.
Taking down steel water tubing and connection 15mm dia bore and removal from site.
Taking down steel water tubing and connection 20mm dia bore and removal from site.
Taking down steel water tubing and connection 25mm dia bore and removal from site.
Supply and fix 15 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and directed.
Refixing 15mm old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
Supply and fix 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and directed.
Refixing 20mm old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
Supply and fix 25 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line complete all as specified and directed.
Refixing 25mm old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.)
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc, including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed.
S&F PVC (SWR) pipes 75 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement, fixed to walls complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement , fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends 110 mm dia complete all as specified and directed.
S&F PVC (SWR) bends 75 mm dia complete all as specified and directed.
Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point, socket point or power point including fixture and fitting such as switches, ceiling roses, pendants , regulators, sockets , light fitting etc. removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good the disturbed surfaces of wall / floor or ceiling to match with existing surface and finishing the surfaces with distemper / white washing / colour washing as per existing complete all as specified and directed.
Taking down carefully by unscrewing from fitting and fixtures such as ceiling fittings, bulk head fittings, tube light fittings, street light, flood LED lights etc complete all as specified and directed.
M&L for concealed point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke(FRLS) cable 1100 volts grade ISI marked drawn through and including Heavy duty PVC rigid conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc excluding flush box suitable for modular switches complete all as specified and directed. Make of wire: L&T/RR Kabel/Finolex Note: Rate of point wiring shall include cutting chases for conduit/flush boxes etc.
M&L for point wiring for power point with PVC insulated and unsheathed multistranded FRLS copper conductor single core 2.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories suitable for modular type fitment including provision of modular flush boxes of suitable size and thickness as per IS complete alongwith copper earth wire PVC insulated & unsheathed multistranded (FRLS) copper conductor cable of size 2.5 sqmm as continous earth wire connected to common earth and erth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. Make of wire: L&T/RR Kabel/Finolex Make of PVC Capping: Finolex/Precision/Prince
All as per item No 5 above but wiring with 4.0 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 4.0Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as continous earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch complete all as specified and directed. Make of wire : L&T/RR Kabel/Finolex
S & F industrial type plug & socket board SP & N enclosure with 2 pole and earth metal plug & socket complete with 10 Amp MCB SP, complete all as specified and directed. Make: Legrand cat part No : 607841 or equivelent make mentioned in Appx 'B' to PS.
M & L for module cover plate with frame as per site requirement for following module:- Make : Legrand/C&S Electric/Havells
(a)4 module
(b) 6 module
(c) 8 module
M & L for Modular metal Flush box as per site requirement. Make : Legrand/C&S Electric/Havells
(a) 4 module
(b) 6/8 module
M & L for modular switch 1 way 6 Amp 1 Module complete all as specified and directed. Make : Legrand Arteor series Cat Part No : 573400 / Kolors (Krest-white) / Crabtree or equivelent make mentioned in Appx 'B' to PS.
M &L for Modular fan step regulator 100 watt 2 module complete all as specified and directed. Make :- Legrand Arteor series Cat Part No : 573416 / Kolors (Krest-white) / Crabtree or equivelent make mentioned in Appx 'B' to PS.
S&F energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 20 watt, channel housing & diffuser of length 1200 mm (approx.) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed. Make : Wipro / Philips / Havells
Supply and fixing in repair recess mounted LED luminaire with full diffuser 36 watt of 2x2 grid for new age work space, powder coated luminaire with minimum 100lm/watt efficiency,25000 to 50000 working hours and 6500CCT complete all as specified and directed. Make: Wipro/Philips/Syska.
Supply and fix in repair round recess mounted LED slim luminaire with full diffuser 24 watt suitable for opearting voltage 220-240VAC and inbuilt driver, powder coated luminaire with minimum 100lm/watt efficacy, 25000 to 50000 working hours and 6000CCT complete all as specified and directed. Make : Philips / Havells / Wipro
S t modi
JAMNAGAR ELECTRIC AND MACHINERY CO
Shree Khodal Infra Project
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .