| 4 | L4₹42.2 L+₹12.5 L (42.4%)Rejected-Finance 97 ABROL NAGAR PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹44.7 L+₹15.1 L (51.0%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
21 May 2025, 6:00 pmClosed
GE (KH) YOL
GE (KH) YOL
Repair/replacement of internal wiring and allied works of Officers Md Accn in Upper Garrison and Repair/Maint of geysers, exhaust fans, ceiling fans and allied works in Upper Garrison at YOL CANTT
2025_MES_704797_1
GE/Y-38/2025-26
Open Tender
Civil Works
Item Rate
180 days
YOL CANTT
As per NIT
7 documents required · 7 mandatory
₹500
GE (KH) YOL
₹92,000
Yes
2 Jul 2025
19 Apr 2025
23 May 2025
19 Apr 2025
21 May 2025
8 May 2025
Amount
PART-I:- Taking down carefully the existing aluminium/copper point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets, ceiling rose, fan regulators, lamp holders, call bell, bell pushes any type etc by unscrewing and taken away from site, complete and make good the disturbed surface as existing, complete all as specified and directed.
Taking down sheet metal enclosure DBs, main switch board etc and making good distrubed surface to match with existing surface, complete all as specified and directed.
M & L for point wiring with 1.5 sqmm (Nominal Area) FRLS PVC insulated unsheathed multi stranded copper conductor, 1100 Volts grade, in and including concealed PVC conduit (ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable size including concealed MS pressed steel (Modular sunken box) terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and Modular cover plate as top cover (ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sqmm (nominal area) copper multistranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point/Exhaust fan point controlled by one switch, complete all as specified and directed. Note : i)Wiring Colour code i.e. Red/Yellow/Blue for Phase, Black for neutral and Green for earth shall be maintained. ii) Rate of cutting chases, cement plaster, white wash and making surface good as existing surface included in quoted rate. iii) Point wiring is considered for Modular Switches and sockets. Rate of Metallic Sunken box and modular sheet cover plate and other connected accessories required for modular point wiring included in quoted rate. iv) Rate of modular switch and sockets will be paid seperately under relevant item.
All as per item No 3 above but for 3 pin 5 Amp socket outlet on same board with 1.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continuos earth on independent board, complete all as specified and directed.
All as per item No 3 above but for 3 pin 5 Amp socket otlet on independant board with 1.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continuos earth on independent board, complete all as specified and directed.
All as per item No 3 above but for 3 pin 15 Amp socket otlet on independant board with 1.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continuos earth on independent board, complete all as specified and directed.
All as per item No 3 above but for one light point controlled by two 2 -way switches, complete all as specified and directed.
M & L for point wiring with 1.5 sqmm (Nominal Area) FRLS PVC insulated unsheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC casing capping/conduit (ISI marked) with accessories such as bends, cross, elbow, tees etc. of suitable size including PVC junction box /MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated hylam sheet top cover (ISI marked) including continuous earth wire FRLS PVC insulated unsheathed 1.5 Sqmm (nominal area) copper multistranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified for one light point/ fan point controlled by one switch, complete all as specified and directed. Note : i) Wiring Colour code i.e. Red/Yellow/Blue for Phase, Black for neutral and Green for earth shall be maintained. ii) Rate of casing&caping included in quoted rate. iii) Point wiring is considered for Modular Switches and sockets. Rate of Metallic Sunken box and modular sheet cover plate and other connected accessories required for modular point wiring included in quoted rate. iv) Rate of modular switch and sockets will be paid seperately under relevant item.
All as per item No 8 above but for 3 pin 5 amps socket outlet on same board with 1.5 sqmm PVC copper conductor (FRLS) cable and PVC insulated, unsheathed 1.5 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed.
All as per item No 8 above but for 3 pin 5 amps socket outlet on independent board with 1.5 sqmm PVC copper conductor (FRLS) cable and PVC insulated, unsheathed 1.5 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed.
All as per item No 8 above but for 3 pin 15 amps socket outlet on independent board with 1.5 sqmm PVC copper conductor (FRLS) cable and PVC insulated, unsheathed 2.5 sqmm stranded copper conductor cable as continous earth wire, complete all as specified and directed.
All as per item No 8 above but for one light point controlled by two 2 -way switches, complete all as specified and directed.
S&F Modular Switch one way 6 Amp, one module 230 Volts, complete all as specified and directed.
S&F Modular Switch one way 16 Amp, one module 230 Volts, complete all as specified and directed.
S&F Modular Switch two way 6 Amp, one module 230 Volts, complete all as specified and directed.
S&F Modular socket 6 Amp 3 Pin, two module 230 Volts, complete all as specified and directed.
S&F Modular socket 6/16 Amp 3 Pin, two module 230 Volts, complete all as specified and directed.
S&F in repair Ceiling rose surface type 3 terminals 65x20mm, complete all as specified and directed.
Supply and fix in repair bell push piano flush type 5 Amp single pole one way, complete all as specified and directed.
S&F in repair Bell electric, Ding Dong AC 230 Volts, single pole, complete all as specified and directed.
Supply and fix in repair Switch piano 6 A SP 230 Volts 2 way, complete all as specified and directed.
Supply and fix in repair Switch piano flush type single pole one way 6 A SP 230 Volts, complete all as specified and directed.
S&F in repair Switch piano flush type single pole one way 16 A SP 230 Volts, complete all as specified and directed.
S&F in repair Socket outlet 2 in 1, 3 pin 6 Amps Flush type, complete all as specified and directed.
S&F in repair Socket outlet 2 in 1, 3 pin, 6 and 16 Amps flush type, complete all as specified and directed.
S&F in repair Switch Socket combination outlet 2 in 1, 3 pin 6 Amps Flush type, complete all as specified and directed.
S&F in repair Switch Socket combination outlet 2 in 1, 3/5 pin 6 and 16 Amps flush type, complete all as specified and directed.
S&F in replacement of Modular Switch one way 6 Amp, one module 230 Volts, complete all as specified and directed.
S&F in replacement of Modular Switch one way 16 Amp, one module 230 Volts, complete all as specified and directed.
S&F in replacement of Modular Switch two way 6 Amp, one module 230 Volts, complete all as specified and directed.
S&F in replacement of Modular socket 6 Amp 3 Pin, two module 230 Volts, complete all as specified and directed.
S&F in replacement of Modular socket 6/16 Amp 3 Pin, two module 230 Volts, complete all as specified and directed.
Supply and fix in repair Lamp Holder, PVC / Polycarbonate type with back plate suitable for batton fittings, complete all as specified and directed.
Supply and fix in repair LED Bulb 9 watt, Cool/warm white 6500k / 3000K, suitable for base B22/ E27, 230 volts, complete all as specified and directed.
Supply and fix in repair LED inverter Bulb 12 watt, Cool/warm white 6500k / 3000K, suitable for base B22/ E27, 230 volts, complete all as specified and directed.
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover with PVC Box of size 8"x10" for fixing switches, sockets & regulator etc, complete all as specified and directed.
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover with PVC Box of size 7"x4" for fixing switches, sockets & regulator etc, complete all as specified and directed.
S & F in repairs 3mm thick backelite sheet (hylam) as sheet cover with PVC Box of size 4"x4" for fixing switches, sockets & regulator etc, complete all as specified and directed.
Supply and fix in repairing LED Adore 2.8 W having base suitable for B22/ E27/ E14 holder CDL Candle Lamp, WW/ CDL, 6500/3000 K, 230 volts, complete all as required at site and directed by Engr - in - Charge. Make: Havells / Polycab/Bajaj /CG
Supply and fix modular switch 6Amps, 1 module including all As per existing make. complete all as specified and as directed by Engr-in- Charge.
Supply and fix modular switch 16Amps, 1 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge.
Supply and fix modular switch 6Amps two way, 1 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge.
Supply and fix modular socket out 6Amps, 2 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge.
Supply and fix modular socket out 6/16Amps, 2 module all As per existing make, complete all as specified and as directed by Engr-in- Charge.
Supply and fix modular Bell Push with indicator 6 Amps, 1 module including all As per existing make, complete all as specified and directed by Engr-in- Charge,
Supply and fix modular fan step regulator, 1 Module including all As per existing make, complete all as specified and directed by Engr-in- Charge.
Supply and fix modular cover plate with frame, 2 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge.
Supply and fix modular cover plate with frame, 3 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge.
Supply and fix modular cover plate with frame, 4 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge.
Supply and fix modular cover plate with frame, 6 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge.
Supply and fix modular cover plate with frame, 8 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge.
Supply and fix modular cover plate with frame, 10 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge,
Supply and fix modular cover plate with frame, 12 module including all As per existing make, complete all as specified and as directed by Engr-in- Charge.
Supply and fix modular metal flush box, 2 module including taking down old unsv one, complete all as specified and directed.
Supply and fix modular metal flush box, 3 module including taking down old unsv one, complete all as specified and directed.
Supply and fix modular metal flush box, 4 module including taking down old unsv one, complete all as specified and directed.
Supply and fix modular metal flush box, 6 module including taking down old unsv one, complete all as specified and directed.
Supply and fix modular metal flush box, 8 module including taking down old unsv one, complete all as specified and directed.
Supply and fix modular metal flush box, 10 module including taking down old unsv one, complete all as specified and directed.
Supply and fix modular metal flush box, 12 module including taking down old unsv one, complete all as specified and directed.
Supply and Fixing in repair the sheet metal enclosure with socket plugtop with MCB of a two pin and earth plug and a socket complete with one double pole MCB of 20 Amps rated, complete all as specified and directed.
Supply and fix in repair sheet metal enclosure (SPN DB) single pole and neutral 8 way double door including taking down old unsv DB any way, complete all as specified and directed.
Supply and fix sheet metal enclosure (SPN DB) single pole and neutral 12 way double door including taking down old unsv DB any way, complete all as specified and directed.
Supply and fix distribution board iron clad TPN DB double door with IP-43 protection 415 V 3 Phase 50 HZ 4 Way complete with appropriate size of copper busbar and neutral link complete and incl cutting chasing to wall for fixiing DB and making good the disturbed wall to match with existing surface, complete all as specified and directed.
S & F in replacement distribution board iron clad, double door with IP-43 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 4 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge (Outgoing MCB will be measured separately).
Supply and fix MCB, SP 6 to 32 Amps, 10 KA, C Series including taking down old unsv MCB SP, complete all as specified and directed. Note : The connection to the MCBs shall be done through thimble/ lugs do not direct wire shall be connected to MCBs.
Supply and fix SPN 240V 32 Amps, 10 KA, C series,including taking down old unsv MCB SPN, complete all as specified and directed. Note : The connection to the MCBs shall be done through thimble/ lugs do not direct wire shall be connected to MCBs.
Supply and fix SPN 240V 63 Amps, 10 KA, C series,including taking down old unsv MCB SPN, complete all as specified and directed. Note : The connection to the MCBs shall be done through thimble/ lugs do not direct wire shall be connected to MCBs.
S & F MCB, TPN, 63 A capacity, 415 V, 10 KA, C series including taking down old MCB TPN, complete all as specified and directed. Note: The connection to the MCBs shall be done through thimble/ lugs do not direct wire shall be connected to MCBs.
S & F MCB, 4 Pole, 63 A capacity, 415 V, 10 KA, C series including taking down old MCB 4 Pole, complete all as specified and directed. Note: The connection to the MCBs shall be done through thimble/ lugs do not direct wire shall be connected to MCBs.
S & F TPN, 4 Pole, 100 A capacity, 415 V, 10 KA, C series including taking down old MCB 4 Pole, complete all as specified and directed. Note: The connection to the MCBs shall be done through thimble/ lugs do not direct wire shall be connected to MCBs.
S & F MCCB, 4 Pole, 100 A capacity, 415 V, 10 KA, C series including taking down old MCB 4 Pole, complete all as specified and directed. Note: The connection to the MCBs shall be done through thimble/ lugs do not direct wire shall be connected to MCBs.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 6 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 sqmm copper conductor and connected to common earth dolly, complete all as specified and directed, including taking down old submain wiring. Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. Make:Finolex, Havells.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 6 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface casing caping medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 6 sqmm copper conductor and connected to common earth dolly, complete all as specified and directed, including taking down old submain wiring. Note :-(i) One run of PVC casing caping, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. Make:Finolex, Havells.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 4 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 4 sqmm copper conductor and connected to common earth dolly, complete all as specified and directed, including taking down old submain wiring. Note :-(i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. Make:Finolex, Havells.
M & L for sub main wiring with two single core PVC insulated unsheathed, 1100 Volts grade, (FRLS) copper cable 4 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface casing caping medium duty (ISI Marked) with conduit accessories such as junction boxes, bends, tees etc. including continuous earth wire PVC insulated unsheathed 1100 volts grade, cable 4 sqmm copper conductor and connected to common earth dolly, complete all as specified and directed, including taking down old submain wiring. Note :-(i) One run of PVC casing caping, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. Make:Finolex, Havells.
S&F in replacement of single core cable PVC insulated and unsheathed, 1100 Volts grade, (FRLS) copper cable 1.5 sqmm multi stranded conductor from point wiring including removel olg existing unserviceable one, complete all as specified and directed. Make:Finolex, Havells.
S&F in replacement of single core cable PVC insulated and unsheathed, 1100 Volts grade, (FRLS) copper cable 2.5 sqmm multi stranded conductor from point wiring including removel olg existing unserviceable one, complete all as specified and directed. Make:Finolex, Havells.
S&F in repair LED tube light fitting integral type 1x 10 W, 3 in 1 light (Cool day light, normal white and warm white in one fitting) 230V, ultra slim square profile LED lighting fixture with extruded polycarbonate, environment friendly, energy efficient ready to use complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light, complete all as specified and directed. Make : Havells/CG/Philips.
S&F in repair LED tube light fitting Motion sensor type 1x 10 W, fitting) 230V, ultra slim square profile LED lighting fixture with extruded polycarbonate, environment friendly, energy efficient ready to use complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable sized, including dismantling of unserviceable tube light, complete all as specified and directed. Make : Havells/CG/Philips.
S&F in repair LED tube light fitting integral type 1x 20 W, 3 in 1 light (Cool day light, normal white and warm white in one fitting) 230V, ultra slim square profile LED lighting fixture with extruded polycarbonate, environment friendly, energy efficient ready to use complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light, complete all as specified and directed. Make : Havells/CG/Philips.
S&F in repair LED tube light fitting Motion sensor type 1x 20 W, 3 in 1 light (Cool day light, normal white and warm white in one fitting) 230V, ultra slim square profile LED lighting fixture with extruded polycarbonate, environment friendly, energy efficient ready to use complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light, complete all as specified and directed. Make : Havells/CG/Philips.
S&F in repair LED tube light fitting inverter type 1x 20 W, 230V, LED tube light fitting 3 in 1 light (Cool day light, normal white and warm white in one fitting) 4 hours backup with extruded polycarbonate, environment friendly, energy efficient ready to use complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light, complete all as specified and directed. Make : Havells/CG/Philips.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as required at site, complete all as specified and directed by Engr - in - Charge.
Supply and fixing in repair round shape 20 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp (warm white/ cool white) suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. Make : Havells/ CG/ Bajaj
Supply and fix in repair bldg security light 50 Watt New generation energy saving and environmental friendly long life LED Bldg security light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having Top Opening seperate toughtned glass/verminproof driver compartment, SPDs with IP66 protection connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket of size 32 mm dia length 1.2 mtr along with clamps, complete all as specified and directed by Engr - in - Charge. Make : Havells /Crompton/Philips.
Supply and fix in repair Decorative wall light fixture made up of Polycarbonate, with 9 W LED lamp B22 base complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable light fitting, complete all as specified and directed. Make : Havells/CG/ philips. Note : Rate of LED Bulb included in quoted rate.
Material and labour for PVC Casing & Caping of size (20 x 12) mm ISI Marked suitable for electrical wiring, complete all as specified and directed.
Material and labour for PVC Casing & Caping of size (25 x 16) mm suitable for electrical wiring, complete all as specified and directed.
Material and labour for uPVC electrical conduit pipe of size 20 mm dia (heavy duty) Ivory color ISI MARKED suitable for electrical wiring including junction box, tees and bends etc, complete all as specified and directed.
Material and labour for uPVC electrical conduit pipe of size 25 mm dia (heavy duty) Ivory color ISI MARKED suitable for electrical wiring including junction box, tees and bends etc, complete all as specified and directed.
Material and labour for electrical round sheet PVC material used for covering junction boxes, fan mounting and other electrical opening on wall, complete all as specified and directed by Engr - in - Charge.
Supply and fixing in repair MCB Protected socket (modular AC box) 3 Module with MCB SP of capacity 25 Amp and power socket for geyser, complete all as specified and directed by Engr - in - Charge.
Material and labour for repair of wooden/ metal box fitted on site for protection of 2 to 4 Nos meter boxes / DB Boxes by dimentling existing unsv hinges, doors and locking arrangements and other part etc and replacing with new hinges, doors, locking arrangements and other parts as required at site and directed by Engr- in- Charge including painting the complete box with paint, complete all as specified and directed by Engr - in - Charge.
Replacement of earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15 mm bore including provn of concrete pit in plain cement concrete M-20 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of rainforced cement concrete M-20 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work.
Taking down ceiling fan of any sweep, any size/make from existing position of any height by disconnecting electrical connections and transporting to workshop. Inspection of ceiling fan in presence of Engr-in-charge/JE (or rep of department) after dismentling spares parts. Transporting ceiling fan back from work shop to site including hanging/ fixing and connecting up and testing etc complete all as required at site and directed by Engr - in - Charge.
M&L for complete repair and maintenance of unserviceable ceiling fan of 1200mm/1400mm sweep at work shop, incl dismantling complete the ceiling fan parts i.e. blades, fan rod, canopy, connection, inspecting serviceability of all the parts, re fixing of serviceable parts after cleaning and replacement of unserviceable parts with company's genuine parts i.e. capacitor, bearing, bushes, shaft, bracket, rubber bush, connecting wire, PVC connector, aluminium clamp for rod, bracket, bush rod, blade and greasing/oiling etc assembling, cleaning and testing of ceiling fan as directed. Note:- (i) Unserviceable parts as above shall be measured and paid separately under relevant items of Sch 'A' as supply only. (ii) Rewinding of stator will be measured & paid for separately under relevant item of Sch 'A'. (iii) Writing of MES Nos and painting of ceiling fan shall be measured & paid separately uner relevant item of Sch 'A'. (iv) A register will be maintained by the contractor for record of repair duly signed by JE and Engr-in-Charge & contractor. (v) Cost of minor part i.e. Cotterr pin, PVC connector, screws shall deemed to be included in the quoted rate.
Removing of old burnt winding wiring any type, cleaning stator complete for burnt wiring, carbon residue and rewinding of stator winding of any type/any make fan/ any stator design ceiling fan of 1200mm sweep with superior quality super enameled winding copper wire of existing specification, gauge and weight with superior quality insulation for satisfactory functioning fan in presence of JE incharge, complete all as directed by Engr-in-Charge.
Supply only ball bearing of existing number suitable for ceiling fan 1200/ 1400mm sweep of approved makes including necessary greasing, complete all as specified and directed. Make : NBC/ SKF/FAG
Supply only gun metal bush of existing size suitable for 1200/ 1400mm sweep ceiling fan, complete all as specified and directed.
Supply only capacitor 2.5 MFD including necessary connection, complete all as specified and directed. MAKE- USHA/Havells/Epcos/BAJAJ
Supply only down rod 15mm bore, 300mm long fixed one end with mild steel U clamp, nut, lockable bolt, rubber reel, lock pin and other end having threaded/ drilled hole end, suitable nut, bolt, split pin and check nut or aluminium clamp duly white painted suitable for all size and makes of ceiling fan, complete all as specified and directed.
All as per Srl Item No. 102 here-in-before but 450mm long.
Supply only blade of 1200mm sweep of ceiling fan, complete all as specified and directed.
Supply and fixed in repair stepped type electronic fan regulator flush type, complete all as specified and directed.
M&L for painting one coat of synthetic enamel paint (white) using spray machine painting on the surface of ceiling fan of 1200/ 1400mm sweep (including blade) complete after preparation of surface i.e cleaning, washing of surfaces filling cavities with filler, cleaning dust and writing MES No., complete all as specified and directed by Engr-in-Charge.
Supply only U clamp/ brass bracket assy with rubber reel with nuts, bolt 10mm dia, lock/ split pin, washer suitable for ceiling fan clamp, complete all as specified and directed.
Supply only top and bottom canopy of plastic with steel screw suitable for rod for fan of 1200/ 1400mm sweep, complete all as specified and directed.
Taking down carefully exhaust fan of any sweep, any size/make from existing position of any height by disconnecting electric connections and transporting to workshop. Inspection of ceiling fan in presence of Engr-in-charge/JE (or rep of department) after dismentling spares parts. Transporting exhaust fan back from work shop to site including hanging/ fixing and connecting up etc, complete all as required at site and directed by Engr - in - Charge.
M&L for complete Repair and maintenance of unserviceable exhaust fan of any sweep at work shop, including dismantling complete the parts i.e. blades, fan cover, connection, inspecting serviceability of all the parts, re fixing of serviceable parts after cleaning and replacement of unserviceable parts with company's genuine parts i.e. capacitor, bearing, bushes, shaft, connecting wire, PVC connector and greasing/oiling etc assembling, cleaning and testing of exhaust fan as directed. Note: (i) Unserviceable parts as above shall be measured and paid separately under relevant items of Sch 'A' as supply only. (ii) Rewinding of stator will be measured & paid for separately under relevant item of Sch 'A'. (iii) Painting of ceiling fan shall be measured & paid separately uner relevant item of Sch 'A'. (iv) A register will be maintained by the contractor for record of repair duly signed by JE and Engr-in-Charge & contractor. (v) Cost of minor part i.e. Cotterr pin, PVC connector, screws shall deemed to be included in the quoted rate.
M&L for rewinding stator of exhaust fan 450mm sweep with super enameled copper winding wire of existing specification, gauge and weight including insulating material, complete all as specified and directed.
M&L for rewinding stator of exhaust fan 300mm sweep with super enameled copper winding wire of existing specification, gauge and weight including insulating material, complete all as specified and directed.
M&L for rewinding stator of exhaust fan 250/200mm sweep with super enameled copper winding wire of existing specification, gauge and weight including insulating material, complete all as specified and directed.
Supply and fixing of motor of plastic body exhaust fan of 200/250mm sweep as per existing sample, complete all as specified and directed by Engr-in-Charge.
Supply only ball bearing of exhaust fan suitable for 200 to 450mm sweep as per existing ball bearing including necessary greasing, complete all as specified and directed. Make:-NBC/SKF/FAG/Norma
Supply only mounting legs with rubber suitable for any type of exhaust fan, complete all as specified and directed.
Supply only of steel blade suitable for exhuast fan upto 300mm sweep, complete all as specified and directed.
Supply only of plastic blade complete set suitable for exhuast fan upto 300mm sweep, complete all as specified and directed.
Supply only of plastic body, suitable for exhaust fan of size 300 mm sweep and making necessary connection, complete all as specified and directed by Engr - in - Charge.
Supply & fix exhaust fan louvers suitable upto 300mm sweep exhuast fan complete with necessary nut, bolt iron work, complete all as specified and directed.
Supply & fix XPM Jaali at wall opening for exhaust fan of size 300mm/450mm sweep of suitable size, complete all as specified and directed by Engr-in-Charge.
Supply only capacitor 1/1.8 MFD 50 Hz suitable for Exhaust fan, complete all as specified and directed. MAKE- USHA/Havells/Epcos/BAJAJ
M&L for painting one coat of synthetic enamel paint (black) using spray machine painting on the surface of exhaust fan of size upto 450mm sweep (including louvers and other parts of exhaust fan) complete after preparation of surface i.e cleaning, washing of surfaces filling cavities with filler, cleaning dust and dirt, complete all as specified and directed by Engr-in-Charge.
Supply only PVC insulated copper (Flexible) conductor PVC sheathed three core 0.50 sqmm for making connections between ceiling rose and winding, complete all as specified and directed.
Taking down water storage heater (Geyser) of 25/35/50 liters capacity from electric socket and disconnecting from PVC connection, water supply and screw down kept aside for reuse at same / different location after cleaning of geyser tank, refixing the same duly grouting nuts, bolts washers and connecting to existing water connection, complete all as specified and as directed by Engineer-in-Charge. Note :- Unserviceable part shall be measured and replaced separately under respective items.
Supply and replacement of heating elements 2KW 230V ISI marked round base suitable for water heater of any type including connection with suitable cable, complete all as specified and directed by Engineer-in-Charge. Make:-Theeta/Racold/Airex
Supply and replacement of heating elements 2KW 230V ISI marked triangular base suitable for water heater of any type including connection with suitable cable, complete all as specified and directed by Engineer-in-Charge. Make:-Theeta/Racold/Airex
Supply and replacement of heating elements 1.5KW 230V ISI marked triangular base suitable for water heater of any type including connection with suitable cable, complete all as specified and directed by Engineer-in-Charge. Make:-Theeta/Racold/Airex
Supply and replacement of heating elements 3KW 230V ISI marked suitable for instant water heater of any type including connection with suitable cable, complete all as specified and directed by Engineer-in-Charge. Make:-Theeta/Racold/Airex
S&F in repair heating element (as per sample exist in ground of make recold/venus geyser) inbulid with round base and having 6 hole for fixing and provision of thermostat of 25 ltrs capacity geyser including necessary studs, screws and rubber gasket/washers, complete all as specified and directed.
S&F in repair for thermostat switch of geyser 230V, (adjustable range bewteen 0 degree to 90 degree centigrade temp range), ISI marked as per existing thermostat suitable for hot water storage heater 25/ 35 / 50 Ltr, complete all as specified and as directed.
S&F in repair for capillary thermostat switch (as per sample exist in ground of make recold/venus geyser) of geyser 230V, (adjustable range bewteen 0 degree to 90 degree centigrade temp range), ISI marked as per existing thermostat suitable for hot water storage heater 25/ 35 / 50 Ltr, complete all as specified and as directed.
S&F in repair for defective steel inner tank of 25 Litres capacity geyser tank made out of steel sheet 2 mm thick suitable for 6 hole assembly, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair for defective steel inner tank of 25 Litres capacity geyser tank made out of steel sheet 2 mm thick suitable for 9 hole assembly, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair defective steel inner tank of 35 Litres capacity geyser tank made out of steel sheet 2 mm thick suitable for 6 hole assembly, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair defective steel inner tank of 35 Litres capacity geyser tank made out of steel sheet 2 mm thick suitable for 9 hole assembly, complete all as specified and as directed by Engineer-in-Charge.
S&F in repair best quality PVC pipe hot and cold water for geyser with adopter both end of size 10mm dia and 600mm length (ISI marked) suitable for geyser, complete all as specified and as directed.
S&F in repair Air release valve 15mm dia, ISI marked for geyser of cap 25/ 35/ 50 Ltr, complete all as specified and directed.
S&F in repair non return valve 15 mm dia, ISI marked for geyser of cap 25/ 35/ 50 Ltr, complete all as specified and directed.
S&F in repair fusiable plug of brass 15mm bore, ISI marked for geyser of cap 25/35/50 Ltr, complete all as specified and directed.
S&F in repair for indicating lamp (green or red), 230V, flush type, suitable for water heater including taking down old unserviceable, complete all as specified and directed.
S&F in repair siphon assembly made out of brass of 25 /35 ltrs (9 hole) capacity geyser including necessary studs, screws and rubber gasket/washers, complete all as specified and directed.
S&F in repair siphon assembly made out of brass of 25 /35 ltrs (6 hole) capacity geyser including necessary studs, screws and rubber gasket/washers, complete all as specified and directed.
Replacement of insulation material (Glass Wool, 25mm thick) for geysers 25-50 ltrs capacity, complete all as specified and directed.
Repair to geysers inner water tank of 25 to 50 ltrs capacity in gas welding / brazing for water tightness, complete all as specified and directed by Engr - in - Charge.
Supply & Fix PVC cable 3 core 1.5 Sqmm flexible stranded, complete all as specified and directed.
Replacement of old unserviceable anchor bolt 12mm x 100mm long, complete all as specifed and directed. (Note:- Anchor bolt shall be grouted with hammer drill only).
S&F in replacement of heavy stainless steel connection pipe withbrass union fitted at both end suitable for connection to 15mm GI pipe, 450mm long for hot water including 01 no PVC washer on both ends, complete all as specified and directed.
M&L for painting of outer body of geyser with two coats of synthetic enamel paint (white colour) by using spray gun and, complete all as specified and directed by Engr - in - Charge.
Taking down wall mounted fan of any sweep, any size/make from existing position of any height by disconnecting elect connections and transporting to workshop. Inspection of ceiling fan in presence of JE/ Engr-In-Charge (or rep of department) after dismentling spares parts. Transporting exhaust fan back from work shop to store yard including hanging/ fixing and connecting up and testing etc, complete all as required at site and directed by Engr - in - Charge.
M&L for complete Repair and maintenance of unserviceable wall mounted fan of any sweep at work shop, incl dismantling complete the parts i.e. blades, fan cover, connection, inspecting serviceability of all the parts, re fixing of serviceable parts after cleaning and replacement of unserviceable parts with company's genuine parts i.e. capacitor, bearing, bushes, shaft, connecting wire, PVC connector and greasing/oiling etc assembling, cleaning and testing of exhaust fan, complete all as specified and directed.
M&L for rewinding stator of wall mounted fan 300mm sweep with super enameled copper winding wire of existing specification, gauge and weight including insulating material, complete all as specified and directed.
Supply only ball bearing of wall mounted fan suitable for 300mm sweep as per existing ball bearing including necessary greasing, complete all as specified and directed. Make : NBC/ SKF/ Norma/ FAG
Supply and fix capacitor of wall mounted fan as per exisiting make and model, complete all as specified and directed.
Supply and Fixing in repair the sheet metal enclosure with socket plugtop with MCB of a two pin and earth plug and a socket complete with one single pole MCB of 20 Amps rated, complete all as specified and directed.
Supply and fix Plug top 3 Pin type of rating 6 Amp, 230 volts, complete all as specified and directed.
Supply and fix Plug top 3 Pin type of rating 16 Amp, 230 volts, complete all as specified and directed.
Supply and fix in replacement of plastic blade complete set suitable for wall mounted fan upto 300mm sweep, complete all as specified and directed.
M&L for GI tubing heavy grade 40mm dia pipe by making holes in wall, fixing of pipe and making disturbed surfaces good as existing for hanging of ceiling fan including all type of necessary attachements like angle iron, flat iron, nuts and bolts etc. required for hanging of ceiling fan all as required at site and as directed by Enge-In-Charge. Note:- (i) The length of the GI pipe shall be as per exisiting (room) length exc 3m but n.exc 4m. (ii) Taking down ceiling fan cleaning and refixing same and making electric connection with fan after fixing of pipe include in quoted rates.
M&L for fixing of ceiling fan with the help of anchor hook in ceiling including fan hanging junction box and making electric connection with fan, complete all as specified and as directed by Enge-In-Charge. Note:- Only fixing of old ceiling fan considered in item.
M&L for fixing of exhaust fan by making hole in stone/brick wall, fixing the exhaust fan with suitable arrangement, finishing the disturbed wall surface and connecting electrically, complete all as required at site and as directed by Enge-In-Charge. Note:- Only fixing of old exhaust fan considered in item.
M&L for fixing of exhaust fan in existing opening with the help of ply board having thickness 10mm and making electrical connection, complete all as required at site and as directed by Enge-In-Charge. Note:- Only fixing of old exhaust fan considered in item.
smc engineering company (BID ID -3296563)
M/S PUSHPINDER ENGINEERS (BID ID -3297112)
Eshaan Construction Co. (BID ID -3302103)
M/S DEEPANSH ELECTRICALS (BID ID -3301933)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .