Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹29.8 L+₹65,235 (2.24%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹33.9 L+₹4.8 L (16.5%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹36.7 L+₹7.6 L (26.0%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
26 Dec 2022, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
PROVN OF ELECTRIC SUPPLY TO PERIMETER GUARD POST AND SECURITY LIGHTS FOR PERIMETER ROAD AT SHIKARGARH AND PROVN OF SMART STREET LIGHTS AT ARMY AREA JODHPUR UNDER GE (A) UTILITY JODHPUR
2022_MES_565294_1
82223/76/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (ARMY) UTILITY
₹83,000
Yes
10 Feb 2023
25 Nov 2022
29 Dec 2022
25 Nov 2022
26 Dec 2022
12 Dec 2022
26 Nov 2022 - 10 Dec 2022
Amount
Supply, fixing, stringing, testing and commissioning of ACSR insulated squirrel conductor of size 6+1/2.11 mm binding with insulators including binding material and connection of all service connections/existing cables complete all as specified and as directed.
S&F LED street light luminaire 45 watt, high performance with single die ceramic base, high power LED light source, IP66 protection, PDC housing & aesthetic finless design and toughened glass cover and street light optics for lighting complete including provn of bracket made of 32mm dia, GI pipe, light grade with suitable length including fixing arrangement complete all as specified and as directed.
M&L for prestressed cement concrete poles, 9 M long of size 102mm x 172mm at top and 102 mm x 279 mm at bottom, class-10, conforming to relevant latest IS complete all as specified and directed.
M&L for steel structure, cross arms, bracing supports, clamps, back plates of any type, section including nuts, bolts, washers, welding, fabrication/bending cold or hot in any size and shape required at site complete including applying of two coats of aluminum paints over a coat of red oxide primer complete all as directed
S&F pin type porcelain insulator, vitreous white, brown or green including one galvanised mild steel spindle, two GI washers and GI Nuts 100 mm height, 65 mm dia for 1100 volts grade complete all as specified.
S&F shackle Type, porcelain, vitreous, white, brown or green insulator, 75 mm in height and 90 mm dia including galvanised mild steel straps of size 30 x 3 mm, insulator bolt of 12 mm dia, washers and nuts for 1100 volt grade complete all as specified and as directed.
M&L for earth continuity conductor or main earthing lead with 4 mm dia galvanised iron or steel wire, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc.as required compete all as specified and as directed.
M&L for stay assembly complete with 230x230x 6 mm thick plate and 16 mm dia stay rod all as shown in electric plate No-1 of SSR-part -1 including stay wire of size 7/4mm dia and suitable loop insulator of appropriate size complete all as specified and directed. Note : Rate quoted is deemed to be inclusive of excavation in any type of soil, PCC foundation etc as required for fixing of stay assy.
M&L for earthing complete with galvanized steel earth plate electrodes 600mmx600mmx6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing wire 4mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 25 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of strata, PCC pit in 1:3:6, type C-1 with RCC cover, charcoal , salt, funnel etc complete all as specified and as directed.
Supply, laying and testing XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core laid in trenches/floor or fixed to wall/pole etc complete all as specified and as directed.
S&F 40mm bore GI tubing, light grade for protection of cables on poles / under road crossing complete all as specified and as directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and not exceeding 10sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil for foundation/ pipes/ cable etc complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 m in depth, and not exceeding 10 M² on plan and getting out in soft/loose soil for erection of poles, struts/stays, leveling of yard etc complete all as specified and directed.
M&L for tibba sand cushioning to underground cable including hand punning down complete all as specified and as directed. Note:- Only punned thickness will be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type I, flat, size 250 mm x 150mm x 40mm complete laid over the cable perpendicular to the cable for protection complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, in soil complete all as specified and directed.
Removing of excavated surplus soils, not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for Cement concrete 1:3:6, type C2, using 40 mm graded stone aggregate as in foundation of pole /struts/stay assembly etc complete all as directed.
M&L for Cement concrete 1:3:6, type C-2, using 20 mm graded stone aggregate, fair finishing to exposed surfaces using extra cement for pedestal of poles/copping including necessary form work complete all as specified and as directed.
Supply, install, testing and commissioning of all in one integrated LED solar light consists of solar photovoltaic module, battery, battery management system, control electronics, LED driver, microwave sensor, inter-connecting cables and pole mounting piece integrated into the luminaire as a single unit. Solar street light with IP65 ingress protection having a system wattage of with 50Wp high efficiency monocrystalline solar panel, highly efficient MPPT based charge controller and 12.8 V, >23.4 Ah Lithium Ferro Phosphate(LiFePO4) battery with proper battery management system. LED lumen efficacy shall be greater than 140lm/W and LED driver should have >90% efficiency. Typical correlated colour temperature should be 5700K with CRI>70. It should have microwave sensor based movement detection and dim level adjustment to effectively extend the working time. AIO should be onsite configurable via a handheld remote. The luminaire should be housed in IK 08 impact resistance certified aluminum with polycarbonate lens cover. The luminaire shall have a specially designed adjustable pole mounting piece for optimal light distribution. LED Wattage =35 Watts and Lumens not<5000 Lumens, with 5 Years OEM Service warranty, and including necessary civil work complete all as specified and directed at site by E.I.C. Make: CAT Part No: BRP110 LED50/757 of Philips or its techno commercial equivalent of Wipro/Havells/approved manufacturer listed in appendix.
S&F Intelligent sensor based LED Street Light fitting 60 Watt, that dims automatically to 50% of the rated wattage on sensing of movements/occupancy within 8 mtr radius (light installed at a height of 8 m above ground level should be able to sense the movement below), with IP 66 Pf>0.95, >110 lm/W and including 3 core 1.5 Sqmm PVC cable copper conductor weather proof from pole box to street light fitting and including necessary civil work all as complete all as specified and directed at site by E.I.C Make: Philips/Wipro/Shakti/Crompton/approved manufacturer listed in appendix.
S&F GI pipe Bracket of 40 mm dia, light grade pipe bend to shape of approx. length 0.75 Mtr including 2 Nos. MS Clamp of flat iron of suitable size complete with nut, bolt, washers Including two coats of aluminium paints over a coat of red oxide primer all as specified and directed.
S&F GI pipe Bracket of 32 mm dia, light grade pipe bend to shape of approx. length 1.5 Mtr including 2 Nos. MS Clamp of flat iron of suitable size complete with nut, bolt, washers Including two coats of aluminium paints over a coat of red oxide primer all as specified and directed at site.
Nvimal Engineers and Contractor
SANJOLI CONSTRUCTION COMPANY
Shri Electrical Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .