| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.7 LAccepted-AOC | 1 | Accepted-AOC Being price submitted by the contractor is lowest | |
| 2 | 2₹6.1 L+₹40,116 (7.10%)Rejected-Finance | 2 | Rejected-Finance Being price submitted by the bidder is not lowest | |
| 3 | 3₹6.1 L+₹49,182 (8.70%)Rejected-Finance | 3 | Rejected-Finance Being price submitted by the bidder is not lowest | |
| 4 | 4₹11.4 L+₹5.8 L (102.6%)Rejected-Finance | 4 | Rejected-Finance Being price submitted by the bidder is not lowest | |
| 5 | 5₹12.5 L+₹6.8 L (120.5%)Rejected-Finance | 5 | Rejected-Finance Being price submitted by the bidder is not lowest |
| Sl No | Description | Qty | Unit | SRI NIKHILDUTTA CONSTRUCTIONS L4 | SRI BALAJI CONSULTANCY SERVICES L2 | ASHOKA CONSTRUCTIONS L3 | S GHOUSE JANI L1 | ET ENTERPRISES L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Sub- head: Earthwork | ||||||||
| 1.10Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | ||||||||
| 1.20 | All kinds of soil | 5.5 | 1 Cum | 167 ₹919 Lowest | 780 ₹4,290 | 500 ₹2,750 | 338.98 ₹1,864 | 580 ₹3,190 |
| 1.30All kinds of soil | ||||||||
| 2.00Sub-head: Concrete work | ||||||||
| 2.10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – All work up to plinth level: | ||||||||
| 2.20 | 1:2:4(1 cement: 2 coarse sand (Zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural soures) | 0.2 | 1 Cum | 6,359 ₹1,272 Lowest | 18,000 ₹3,600 | 7,878 ₹1,576 | 6,779.66 ₹1,356 | 6,500 ₹1,300 |
| 2.30 | 1:5:10 (1 cement : 5 coarse sand(zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) | 0.1 | 1 Cum | 4,900 ₹490 Lowest | 15,000 ₹1,500 | 5,500 ₹550 | 5,084.75 ₹508 | 7,500 ₹750 |
| 3.00Sub- head:Brick work | ||||||||
| 3.10Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand): | ||||||||
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
18 Aug 2025, 10:30 amClosed
AO,
ICAR-NMRI, Chengicherla, Boduppal, Hyderabad
Construction of shed near badminton court at ICAR-NMRI, Hyderabad
2025_DARE_871151_1
2-216/2025-26/NMRI/Works/Shed
Open Tender
Miscellaneous Works
Lump-sum
ICAR-NMRI, Chengicherla, Boduppal Hyderabad
Please refer Tender Documents
2 documents required · 2 mandatory
₹0
₹15,000
Yes
17 Dec 2025
30 Jul 2025
19 Aug 2025
31 Jul 2025
18 Aug 2025
11 Aug 2025
Amount
Sub- head: Earthwork
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
All kinds of soil
Sub-head: Concrete work
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – All work up to plinth level:
1:2:4(1 cement: 2 coarse sand (Zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural soures)
1:5:10 (1 cement : 5 coarse sand(zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Sub- head:Brick work
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand):
With Modular bricks.
Sub-head: Wood and PVC Work
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fasteners shall be paid for separately).
Second class teak wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well-matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Sub-head: Steel Work
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes.
Sub-Head: Roofing
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm(+0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineering-in-charge. The sheet shall be fixed using self-drilling/self-tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizonal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of man “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.
Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
GI metal ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.50 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gsm/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
Sub-head: Finishing
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat; preparation of surface, etc. complete.
On steel work
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
One coat
Sub-Head: Aluminum Work
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing/paneling, C.P. brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)
For fixed portion
Anodised aluminum (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately)
Anodised aluminum (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side.
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminum snap beading shall be paid in basic item):
With float glass panes of 4.0mm thickness
Lumpsum on Electrical fitting and carpentry fitting
SRI BALAJI CONSULTANCY SERVICES (BID ID -3267473)
ASHOKA CONSTRUCTIONS (BID ID -3266571)
SRI NIKHILDUTTA CONSTRUCTIONS (BID ID -3267367)
ET ENTERPRISES (BID ID -3264328)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .