| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 CrAccepted-AOC 23 WHITE CASTLE 34 35 UNION PARK CHEMBUR MUMBAI MAHARASHTRA 400071 UDYAM MH 18 0012832 | MUMBAI SUBURBAN | MAHARASHTRA | 400071 | ₹13.3 Cr | L1 | Accepted-AOC Contract Awarded to L1 bidder |
| 2 | L2₹16.0 CrRejected-Finance | ₹16.0 Cr | L2 | Rejected-Finance L2 bidder |
| Sl No | Description | Qty | Unit | COMMTEL NETWORKS PRIVATE LIMITED L1 | Eratronics Pvt Ltd L2 |
|---|---|---|---|---|---|
| 1.00PLIDS System for DUPL DAHEJ (INSTA. OF PLIDS @ DAHEJ DUPL PIPELINE) | |||||
| 1.01 | Design and supply DAHEJ-SV-1 PLIDS
Design and Supply of complete PLIDS System for DAHEJ to SV-1 (Vengani) section (Pipeline distance: - 19.3 KM, Optical distance: - 22 KM). Single Channel Controller including processing Server unit along with Rack at Dahej. Complete supplied system under this SOR will be 2 years On-Site Warranty. Latest/Upgraded Licensed Software,OFC based PLIDS,Fiber type Single mode: ITU-T G.655/G.652D/G.652B/G.657A1 G.652 series1550 nm,Monitoring Range: - At least 48 (Forty-Eight) KM or more (for each Sensor port in one direction per trench)
Coherent Optical time domain Reflectometer (COTDR), DAS- Series1550 nm with Quantitative analyses. (Amplitude/Energy level/ Amplitude and Phase shift of back scatter light by launching Laser pulse in fiber)
Optical fiber power losses (splicing losses, fiber losses etc.) budget to 18 DB per sensor port in one direction PLIDS System should be able to support minimum step loss of 0.3 dB splice loss at any given point. No. of Sensor channels per controller 01 (One) or 02 (Two), whole section to be covered. In Dual Channel, Intrusion Detection must be real time & Simultaneous. Independent launch and detect module for each port.
No multiplexing/No switching/ No splitting/ No toggling is allowed, if more than one sensor channel per Controller. laser sources are to separate one.
Operating temperature +5 to +55degC
Inbuilt Redundant Power supply 115-230 VAC; 50-60 Hz / 18 # 28 V DC / 42 # 48 V DC
Humidity 85% RH
Front panel user interface Display & soft buttons
Laser shutoff Required
Communications Ethernet
Data storage eSATA / USB port for external HDD
Proper Space for storing signatures and playbacks
Operating system Unix / Linux
Diagnostics GUI based software from OEM
Optical connectors E2000 or better
Remote access Full remote control
Certification UL, IEC, FCC / CE / BIS
Maximum power consumption of PLIDS system (excluding HMIs) shall not exceed 450W . Refer
Tender SCC and SOW for more details | 1 | EA | 1,52,00,001 ₹1.8 Cr | 1,63,34,540 ₹1.9 Cr |
| 1.02 | Supply & Installation of RWS
Supply and Installation of Remote Work station for PLIDS system at GAIL DAHEJ Terminal.Complete supplied system under this SOR will be 2 years On-Site Warranty. Refer Tender SCC and SOW for more details | 1 | EA | 3,25,000 ₹3.8 L | 4,85,654 ₹5.7 L |
| 1.03 | ITC for PLIDS Dahej-SV-1
Installation and Commissioning of complete PLIDS system for Dahej to SV-1 section.Complete supplied system under this SOR will be 2 years On-Site Warranty.Refer Tender SCC and SOW for more details | 1 | EA | 5,00,000 ₹5.9 L | 18,34,453 ₹21.6 L |
| 2.00PLIDS System for DUPL HAZIRA (PLIDS System SV-2 to IP-3 (Hazira Reg.) | |||||
| 2.01 | Design and supply SV-1 to SV-4 PLIDS
Design and Supply of complete PLIDS System for SV-1 Vengani to SV-4 (Morthan) section (Pipeline distance: -54 KM, Optical distance: -56.1 KM). Dual Channel Controller including processing Server unit at SV-2 Mothiya. Complete supplied system under this SOR will be 2 years On-Site Warranty. Latest/Upgraded Licensed Software,OFC based PLIDS,Fiber type Single mode: ITU-T G.655/G.652D/G.652B/G.657A1 G.652 series1550 nm, Monitoring Range: - At least 48 (Forty-Eight) KM or more (for each Sensor port in one direction per trench) Coherent Optical time domain Reflectometer (COTDR), DAS- Series1550 nm with Quantitative analyses. (Amplitude/Energy level/ Amplitude and Phase shift of back scatter light by launching Laser pulse in fiber) Optical fiber power losses (splicing losses, fiber losses etc.) budget to 18 DB per sensor port in one direction PLIDS System should be able to support minimum step loss of 0.3 dB splice loss at any given point. No. of Sensor channels per controller 01 (One) or 02 (Two), whole section to be covered. In Dual Channel, Intrusion Detection must be real time & Simultaneous. Independent launch and detect module for each port.
No multiplexing/No switching/ No splitting/ No toggling is allowed, if more than one sensor channel per Controller. laser sources are to separate one.
Operating temperature +5 to +55degC
Inbuilt Redundant Power supply 115-230 VAC; 50-60 Hz / 18 # 28 V DC / 42 # 48 V DC
Humidity 85% RH
Front panel user interface Display & soft buttons
Laser shutoff Required
Communications Ethernet
Data storage eSATA / USB port for external HDD
Proper Space for storing signatures and playbacks
Operating system Unix / Linux
Diagnostics GUI based software from OEM
Optical connectors E2000 or better
Remote access Full remote control
Certification UL, IEC, FCC / CE / BIS
Maximum power consumption of PLIDS system (excluding HMIs) shall not exceed 450W.Refer Tender
SCC and SOW for more details | 1 | EA | 2,43,00,000 ₹2.9 Cr | 2,39,57,541 ₹2.8 Cr |
| 2.02 | Design and supply SV-7 to SV-11 PLIDS
Design and Supply of complete PLIDS System for SV-7 (Jalalpore) to SV-11 (Sonwada) section
(Pipeline distance: -64.5 KM, Optical distance: -70.5 KM). Dual Channel Controller including
processing Server unit at SV-9 Nandarkha.Complete supplied system under this SOR will be 2 years
On-Site Warranty. Latest/Upgraded Licensed Software,OFC based PLIDS,Fiber type
Single mode: ITU-T G.655/G.652D/G.652B/G.657A1 G.652 series1550 nm,Monitoring Range: - At
least 48 (Forty-Eight) KM or more (for each Sensor port in one direction per trench)
Coherent Optical time domain Reflectometer (COTDR), DAS- Series1550 nm with Quantitative
analyses. (Amplitude/Energy level/ Amplitude and Phase shift of back scatter light by launching Laser
pulse in fiber)
Optical fiber power losses (splicing losses, fiber losses etc.) budget to 18 DB per sensor port in one direction PLIDS System should be able to support minimum step loss of 0.3 dB splice loss at any given point. No. of Sensor channels per controller 01 (One) or 02 (Two), whole section to be covered. In Dual Channel, Intrusion Detection must be real time & Simultaneous. Independent launch and detect module for each port. No multiplexing/No switching/ No splitting/ No toggling is allowed, if more than one sensor channel per Controller. laser sources are to separate one.
Operating temperature +5 to +55degC
Inbuilt Redundant Power supply 115-230 VAC; 50-60 Hz / 18 # 28 V DC / 42 # 48 V DC
Humidity 85% RH
Front panel user interface Display & soft buttons
Laser shutoff Required
Communications Ethernet
Data storage eSATA / USB port for external HDD
Proper Space for storing signatures and playbacks
Operating system Unix / Linux
Diagnostics GUI based software from OEM
Optical connectors E2000 or better
Remote access Full remote control
Certification UL, IEC, FCC / CE / BIS
Maximum power consumption of PLIDS system (excluding HMIs) shall not exceed 450W.Refer Tender
SCC and SOW for more details | 1 | EA | 2,43,00,000 ₹2.9 Cr | 2,39,57,541 ₹2.8 Cr |
| 2.03 | ITC for PLIDS SV-1 to SV-4
Installation and Commissioning of complete PLIDS system for SV-1 to SV-4 section.Complete supplied system under this SOR will be 2 years On-Site Warranty.Refer Tender SCC and SOW for more details | 1 | EA | 9,00,000 ₹10.6 L | 31,35,439 ₹37.0 L |
| 2.04 | ITC for PLIDS SV-7 to SV-11
Installation and Commissioning of complete PLIDS system for SV-7 to SV-11 section. Complete supplied system under this SOR will be 2 years On-Site Warranty.Refer Tender SCC and SOW for more details | 1 | EA | 9,00,000 ₹10.6 L | 31,35,439 ₹37.0 L |
| 2.05 | Supply & Installation of RWS
Supply and Installation of Remote Work station for PLIDS system each one at HAZIRA Compressor station Control Room. .Refer Tender SCC and SOW for more details | 1 | EA | 3,25,000 ₹3.8 L | 4,85,654 ₹5.7 L |
Updated dates
Tender Value
Refer Docs
EMD Value
₹20 L
Closing Date
8 Dec 2025, 2:00 pmClosed
RAJEEV KUMAR
Hazira Compressor Station, Ichhapore Magdalla Road, PO- ONGCL, Hazira, Dist. Surat 394 518
DESIGN, ENGG, SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF PIPELINE LEAK AND INTRUSION DETECTION SYSTEM (PLIDS) IN BETWEEN PIPELINE SECTION OF DAHEJ TO SV4 AND SV7 TO IP3 OF DUPL
2025_GAIL_254854_1
GAIL/HZR/CNP/1328421/47C/25-26
Open Tender
Miscellaneous Works
425 days
Hazira Compressor Station
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹20 L
Hazira Compressor Station
16 Mar 2026
10 Nov 2025
9 Dec 2025
10 Nov 2025
8 Dec 2025
21 Nov 2025
20 Nov 2025
PLIDS System for DUPL DAHEJ (INSTA. OF PLIDS @ DAHEJ DUPL PIPELINE)
Design and supply DAHEJ-SV-1 PLIDS Design and Supply of complete PLIDS System for DAHEJ to SV-1 (Vengani) section (Pipeline distance: - 19.3 KM, Optical distance: - 22 KM). Single Channel Controller including processing Server unit along with Rack at Dahej. Complete supplied system under this SOR will be 2 years On-Site Warranty. Latest/Upgraded Licensed Software,OFC based PLIDS,Fiber type Single mode: ITU-T G.655/G.652D/G.652B/G.657A1 G.652 series1550 nm,Monitoring Range: - At least 48 (Forty-Eight) KM or more (for each Sensor port in one direction per trench) Coherent Optical time domain Reflectometer (COTDR), DAS- Series1550 nm with Quantitative analyses. (Amplitude/Energy level/ Amplitude and Phase shift of back scatter light by launching Laser pulse in fiber) Optical fiber power losses (splicing losses, fiber losses etc.) budget to 18 DB per sensor port in one direction PLIDS System should be able to support minimum step loss of 0.3 dB splice loss at any given point. No. of Sensor channels per controller 01 (One) or 02 (Two), whole section to be covered. In Dual Channel, Intrusion Detection must be real time & Simultaneous. Independent launch and detect module for each port. No multiplexing/No switching/ No splitting/ No toggling is allowed, if more than one sensor channel per Controller. laser sources are to separate one. Operating temperature +5 to +55degC Inbuilt Redundant Power supply 115-230 VAC; 50-60 Hz / 18 # 28 V DC / 42 # 48 V DC Humidity 85% RH Front panel user interface Display & soft buttons Laser shutoff Required Communications Ethernet Data storage eSATA / USB port for external HDD Proper Space for storing signatures and playbacks Operating system Unix / Linux Diagnostics GUI based software from OEM Optical connectors E2000 or better Remote access Full remote control Certification UL, IEC, FCC / CE / BIS Maximum power consumption of PLIDS system (excluding HMIs) shall not exceed 450W . Refer Tender SCC and SOW for more details
Supply & Installation of RWS Supply and Installation of Remote Work station for PLIDS system at GAIL DAHEJ Terminal.Complete supplied system under this SOR will be 2 years On-Site Warranty. Refer Tender SCC and SOW for more details
ITC for PLIDS Dahej-SV-1 Installation and Commissioning of complete PLIDS system for Dahej to SV-1 section.Complete supplied system under this SOR will be 2 years On-Site Warranty.Refer Tender SCC and SOW for more details
PLIDS System for DUPL HAZIRA (PLIDS System SV-2 to IP-3 (Hazira Reg.)
Design and supply SV-1 to SV-4 PLIDS Design and Supply of complete PLIDS System for SV-1 Vengani to SV-4 (Morthan) section (Pipeline distance: -54 KM, Optical distance: -56.1 KM). Dual Channel Controller including processing Server unit at SV-2 Mothiya. Complete supplied system under this SOR will be 2 years On-Site Warranty. Latest/Upgraded Licensed Software,OFC based PLIDS,Fiber type Single mode: ITU-T G.655/G.652D/G.652B/G.657A1 G.652 series1550 nm, Monitoring Range: - At least 48 (Forty-Eight) KM or more (for each Sensor port in one direction per trench) Coherent Optical time domain Reflectometer (COTDR), DAS- Series1550 nm with Quantitative analyses. (Amplitude/Energy level/ Amplitude and Phase shift of back scatter light by launching Laser pulse in fiber) Optical fiber power losses (splicing losses, fiber losses etc.) budget to 18 DB per sensor port in one direction PLIDS System should be able to support minimum step loss of 0.3 dB splice loss at any given point. No. of Sensor channels per controller 01 (One) or 02 (Two), whole section to be covered. In Dual Channel, Intrusion Detection must be real time & Simultaneous. Independent launch and detect module for each port. No multiplexing/No switching/ No splitting/ No toggling is allowed, if more than one sensor channel per Controller. laser sources are to separate one. Operating temperature +5 to +55degC Inbuilt Redundant Power supply 115-230 VAC; 50-60 Hz / 18 # 28 V DC / 42 # 48 V DC Humidity 85% RH Front panel user interface Display & soft buttons Laser shutoff Required Communications Ethernet Data storage eSATA / USB port for external HDD Proper Space for storing signatures and playbacks Operating system Unix / Linux Diagnostics GUI based software from OEM Optical connectors E2000 or better Remote access Full remote control Certification UL, IEC, FCC / CE / BIS Maximum power consumption of PLIDS system (excluding HMIs) shall not exceed 450W.Refer Tender SCC and SOW for more details
Design and supply SV-7 to SV-11 PLIDS Design and Supply of complete PLIDS System for SV-7 (Jalalpore) to SV-11 (Sonwada) section (Pipeline distance: -64.5 KM, Optical distance: -70.5 KM). Dual Channel Controller including processing Server unit at SV-9 Nandarkha.Complete supplied system under this SOR will be 2 years On-Site Warranty. Latest/Upgraded Licensed Software,OFC based PLIDS,Fiber type Single mode: ITU-T G.655/G.652D/G.652B/G.657A1 G.652 series1550 nm,Monitoring Range: - At least 48 (Forty-Eight) KM or more (for each Sensor port in one direction per trench) Coherent Optical time domain Reflectometer (COTDR), DAS- Series1550 nm with Quantitative analyses. (Amplitude/Energy level/ Amplitude and Phase shift of back scatter light by launching Laser pulse in fiber) Optical fiber power losses (splicing losses, fiber losses etc.) budget to 18 DB per sensor port in one direction PLIDS System should be able to support minimum step loss of 0.3 dB splice loss at any given point. No. of Sensor channels per controller 01 (One) or 02 (Two), whole section to be covered. In Dual Channel, Intrusion Detection must be real time & Simultaneous. Independent launch and detect module for each port. No multiplexing/No switching/ No splitting/ No toggling is allowed, if more than one sensor channel per Controller. laser sources are to separate one. Operating temperature +5 to +55degC Inbuilt Redundant Power supply 115-230 VAC; 50-60 Hz / 18 # 28 V DC / 42 # 48 V DC Humidity 85% RH Front panel user interface Display & soft buttons Laser shutoff Required Communications Ethernet Data storage eSATA / USB port for external HDD Proper Space for storing signatures and playbacks Operating system Unix / Linux Diagnostics GUI based software from OEM Optical connectors E2000 or better Remote access Full remote control Certification UL, IEC, FCC / CE / BIS Maximum power consumption of PLIDS system (excluding HMIs) shall not exceed 450W.Refer Tender SCC and SOW for more details
ITC for PLIDS SV-1 to SV-4 Installation and Commissioning of complete PLIDS system for SV-1 to SV-4 section.Complete supplied system under this SOR will be 2 years On-Site Warranty.Refer Tender SCC and SOW for more details
ITC for PLIDS SV-7 to SV-11 Installation and Commissioning of complete PLIDS system for SV-7 to SV-11 section. Complete supplied system under this SOR will be 2 years On-Site Warranty.Refer Tender SCC and SOW for more details
Supply & Installation of RWS Supply and Installation of Remote Work station for PLIDS system each one at HAZIRA Compressor station Control Room. .Refer Tender SCC and SOW for more details
PLIDS System for DUPL SILVASSA (PLIDS System SV-2 to IP-3 (Silvassa Reg))
Design and supply SV-11 to SV-14 PLIDS Design and Supply of complete PLIDS System for SV-11 (Sonwada) to SV-14 (Vaghadi) section (Pipeline distance: -68KM, Optical distance: -72.61KM). Dual Channel Controller including processing Server unit at IP-2 Silvassa with Outdoor Battery Bank Cum Charger Rack. Complete supplied system under this SOR will be 2 years On-Site Warranty. Latest/Upgraded Licensed Software,OFC based PLIDS,Fiber type Single mode: ITU-T G.655/G.652D / G.652B / G.657A1 G.652 series1550 nm,Monitoring Range: - At least 48 (Forty-Eight) KM or more (for each Sensor port in one direction per trench) Coherent Optical time domain Reflectometer (COTDR), DAS- Series1550 nm with Quantitative analyses. (Amplitude/Energy level/ Amplitude and Phase shift of back scatter light by launching Laser pulse in fiber) Optical fiber power losses (splicing losses, fiber losses etc.) budget to 18 DB per sensor port in one direction PLIDS System should be able to support minimum step loss of 0.3 dB splice loss at any given point. No. of Sensor channels per controller 01 (One) or 02 (Two), whole section to be covered. In Dual Channel, Intrusion Detection must be real time & Simultaneous. Independent launch and detect module for each port. No multiplexing/No switching/ No splitting/ No toggling is allowed, if more than one sensor channel per Controller. laser sources are to separate one. Operating temperature +5 to +55degC Inbuilt Redundant Power supply 115-230 VAC; 50-60 Hz / 18 # 28 V DC / 42 # 48 V DC Humidity 85% RH Front panel user interface Display & soft buttons Laser shutoff Required Communications Ethernet Data storage eSATA / USB port for external HDD Proper Space for storing signatures and playbacks Operating system Unix / Linux Diagnostics GUI based software from OEM Optical connectors E2000 or better Remote access Full remote control Certification UL, IEC, FCC / CE / BIS Maximum power consumption of PLIDS system (excluding HMIs) shall not exceed 450W.Refer Tender SCC and SOW for more details
Design and supply SV-14 to IP-3 PLIDS Design and Supply of complete PLIDS System for SV-14 (Vaghadi) to IP-3 (Aptibudruk) section (Pipeline distance: -16.7KM, Optical distance: -17.9 KM). Complete supplied system under this SOR will be 2 years On-Site Warranty. Latest/Upgraded Licensed Software,OFC based PLIDS,Fiber type Single mode: ITU-T G.655/G.652D/G.652B/G.657A1 G.652 series1550 nm,Monitoring Range: - At least 48 (Forty-Eight) KM or more (for each Sensor port in one direction per trench) Coherent Optical time domain Reflectometer (COTDR), DAS- Series1550 nm with Quantitative analyses. (Amplitude/Energy level/ Amplitude and Phase shift of back scatter light by launching Laser pulse in fiber) Optical fiber power losses (splicing losses, fiber losses etc.) budget to 18 DB per sensor port in one direction PLIDS System should be able to support minimum step loss of 0.3 dB splice loss at any given point. No. of Sensor channels per controller 01 (One) or 02 (Two), whole section to be covered. In Dual Channel, Intrusion Detection must be real time & Simultaneous. Independent launch and detect module for each port. No multiplexing/No switching/ No splitting/ No toggling is allowed, if more than one sensor channel per Controller. laser sources are to separate one. Operating temperature +5 to +55degC Inbuilt Redundant Power supply 115-230 VAC; 50-60 Hz / 18 # 28 V DC / 42 # 48 V DC Humidity 85% RH Front panel user interface Display & soft buttons Laser shutoff Required Communications Ethernet Data storage eSATA / USB port for external HDD Proper Space for storing signatures and playbacks Operating system Unix / Linux Diagnostics GUI based software from OEM Optical connectors E2000 or better Remote access Full remote control Certification UL, IEC, FCC / CE / BIS Maximum power consumption of PLIDS system (excluding HMIs) shall not exceed 450W.Refer Tender SCC and SOW for more details
ITC for PLIDS SV-11 to SV-14 Installation and Commissioning of complete PLIDS system for SV-11 to SV-14 section including Outdoor Battery Bank Cum Charger . Complete supplied system under this SOR will be 2 years On-Site Warranty.Refer Tender SCC and SOW for more details
ITC for PLIDS SV-14 to IP-3 Installation and Commissioning of complete PLIDS system for SV-14 to IP-3 section. Complete supplied system under this SOR will be 2 years On-Site Warranty.Refer Tender SCC and SOW for more details
Supply & Installation of RWS Supply and Installation of Remote Work station for PLIDS system each one at IP-2 Silvassa Control Room. complete supplied system under this SOR will be 2 years..Refer Tender SCC and SOW for more details
5 YEars CAMC for PLIDS
5 YEars PLIDS On-Site CAMC 5 years of On-site complete Comprehensive AMC for complete supplied PLIDS system: Please refer the detailed SCC & SOW as described in the tender documen
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.44 MB
Tender.pdf
Tender Documents • 2.38 MB
Annexures.rar
Other Document • 13.38 MB
CBA.pdf
Other Document • 0.17 MB
BOQ_293589.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid