| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Vishvaraj Environment Private Limited L1 |
|---|---|---|---|---|
| 1.00 | Supply ,delivery at site and installation & commissiong of Open chennel Ultrasonic Flow Meter at Inlet Chamber as per technical Specification and direction of the EIC | 1 | Nos | 1,78,407 ₹1,78,407 Lowest |
| 2.00 | Dismantling , repairing and reinstallation with supplying of New spare i.e gear and pinion main shaft etc at Flash Mixer as required as per sample , technical specification and direction of the EIC | 2 | Item | 90,105 ₹1,80,210 Lowest |
| 3.00 | Withdrawling , dismantling and repairing and reinstallation of Floculaor unit and replacement of both upper & lower side bearing and shaft as reuired as per technical Specification and direction of the EIC | 1 | Item | 97,613 ₹97,613 Lowest |
| 4.00 | Withdrawling and dismantling the Gear box and repairing with replacement of Gear at Alum Agitator as per sample and technical specification and direction of the EIC | 2 | Item | 52,561 ₹1,05,122 Lowest |
| 5.00 | Dismantling , repairing and reinstallation of Sluice gate Valve seat with supplying of spare at IPS/Floculator unit as required and direction of EIC | 8 | Set | 22,526 ₹1,80,208 Lowest |
| 6.00 | Supply and delivery at site of of chaquer plate with fixing in different place as required at IPS area as per direction of EIC | 2,000 | Kg | 155 ₹3,10,000 Lowest |
| 7.00 | Dismantling , repairing and reinstallation with replacement of spare i.e gear box as required for Poly dosing Agitator aas per technical specification and direction of the EIC | 1 | Set | 52,561 ₹52,561 Lowest |
| 8.00 | Supply ,and delivery at site and instalation all delivery pipe and fabrication the same as diffuser unit as per requirement and technical specification and direction of EIC | 1 | Lot | 38,294 ₹38,294 Lowest |
| 9.00 | Supply,delivery at site and installation of floating equipment for Mechanical Level Indicatior for Poly Solution Level Indicator at Poly dosing room as per specification and direction of the EIC | 5 | Item | 77,340 ₹3,86,700 Lowest |
| 10.00 | Supply,delivery at site and installation of Loss of Head (LOH) indicator as per specifiction with mounting structure at filter house as per requirement and technical specification and direction of EIC | 4 | Set | 2,29,767 ₹9,19,068 Lowest |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
12 Mar 2024, 4:00 pmClosed
SE, MC-I, EM Sector, KMDA
Office of the S.E, MC-I, EM Sector, KMDA, L Block, 1st Floor, Unnayan Bhavan, Salt Lake City, Kolkata- 700 091
Renovation, repairing and replacing of Electro-Mechanical equipments related to 140 MLD Water Treatment Plant at Panihara, Madhyamgram within Madhyamgram Municipal Area.
2024_KMDA_670452_1
04 / KMDA / EM / SE / MC-I / NIT/ 2023-24 (2nd Call)
Open Tender
Electrical Work/ Equipment
Item Rate
485 days
Madhyamgram
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹2 L
Office of the SE, MC_I, EM sector, KMDA
31 Jul 2024
20 Feb 2024
14 Mar 2024
20 Feb 2024
12 Mar 2024
20 Feb 2024
23 Feb 2024
Amount
Supply ,delivery at site and installation & commissiong of Open chennel Ultrasonic Flow Meter at Inlet Chamber as per technical Specification and direction of the EIC
Dismantling , repairing and reinstallation with supplying of New spare i.e gear and pinion main shaft etc at Flash Mixer as required as per sample , technical specification and direction of the EIC
Withdrawling , dismantling and repairing and reinstallation of Floculaor unit and replacement of both upper & lower side bearing and shaft as reuired as per technical Specification and direction of the EIC
Withdrawling and dismantling the Gear box and repairing with replacement of Gear at Alum Agitator as per sample and technical specification and direction of the EIC
Dismantling , repairing and reinstallation of Sluice gate Valve seat with supplying of spare at IPS/Floculator unit as required and direction of EIC
Supply and delivery at site of of chaquer plate with fixing in different place as required at IPS area as per direction of EIC
Dismantling , repairing and reinstallation with replacement of spare i.e gear box as required for Poly dosing Agitator aas per technical specification and direction of the EIC
Supply ,and delivery at site and instalation all delivery pipe and fabrication the same as diffuser unit as per requirement and technical specification and direction of EIC
Supply,delivery at site and installation of floating equipment for Mechanical Level Indicatior for Poly Solution Level Indicator at Poly dosing room as per specification and direction of the EIC
Supply,delivery at site and installation of Loss of Head (LOH) indicator as per specifiction with mounting structure at filter house as per requirement and technical specification and direction of EIC
Servicing of Filter Bed Control desk 10 Nos with replacement of spare i.e level indicator, pressure indicator, B/W flow Meter, Valve position indicator, AR pressure indicator, digital Timer etc complete at Filter House as per specification and direction of EIC
Dismantling , repairing of NRV(800 NB ) Seat and Dashpot with supplying of Sapre i.e Control Nozzle of Dashpot , poston Head including Shaft etc at Filter House as required as per sample and technical specification and direction of EIC
Supply,delivery at site of LED 140 W Steet Light and fitting and fixing the same as per specification and direction of EIC
Supply and delivery of Cable of 16 Sq.mm XLPE Cable with laying for Street/yard Lighting as per specification and direction of EIC
Supply,delivery at site of LED 140 W Bay Light and fitting and fixing the same as per specification and direction of EIC
Repairing of Aircondition and supplying of spare ie gass, Panel Board etc as required and direction of EIC
Restoration of Pre & Post (25Kg and 10 Kg) Chlorination System completely with supplying of different spare as per requirement as per technical specification and standared for Post & Pre Chlorination System at Chemical House as per direction of EIC
Supply, delivery at site of Non-Return Valve (150 NB ) with installation as per technical specification at WWRS as per technical specification and direction of the EIC
Supply,delivery at Site and Installation of Wate Water Submersible Sludge Pump 15 HP (capacity , 15.5 MWC Head, 150 CUM/Hr , 1450 RPM) at WWRS as per specification and per direction of EIC
Supply ,delivery and installtion of Sludge Sump Pump with necessary spare all complete at Sludge Pump House as per specification and as per direction of EIC
Servicing, repairing of FlowMeter with supplying of Spare as per requirement for Clear water at Common delivery line as per diredtion of EIC
Supply and installation of ACB 3200Amp , 75 KA, MDO type , Make : L&T) at LT Main Incomer Panel as per technical Specification and per direction of EIC
Supply and installation of Microprocesoer Based , SR 18G ,ACB 630 Amp , 50 KA, MDO type , Make : L&T) at LT Main Incomer Panel as per technical Specification and per direction of EIC
Supply and installation of Microprocesoer Based , SR 18G ACB 2500 Amp , 60 KA, MDO type , Make : L&T) at LT Main Incomer Panel as per technical Specification and per direction of EIC
Servicing of and overhauling the all LT Panel with ACB 630 Amp,800 Amp, 2500 Amp, 3200Amp as per standard practice and direction of EIC
Supply and delivery at site of Micom Protection Relay Qty-3 Nos (Make: Seimens , Model : 7SR1102 and 7SR1105) as per technical specification and servicing and overhauling the HT panel as per direction of EIC
Servicing ,overhauling and supplying of required spare for 2 nos Centrifuge as per specification at Centrifuse Room as per direction of EIC
Supply, deliver of boost cum Bettery cherger panel all complete SEDCL 33 KV HT Room as per specification and direction of EIC
Supply , delivery and installation of Alum Dosing Orific Meter (Model H250 /M9) at Inlet Chenel as per sample and direction of EIC
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .