Exe.Engr._II, KSHED, P.W.Dte.
Ground Floor, Lee Road Hostel, 3, Lee Road P.O._Lala Lajpat Rai Sarani, Kolkata_700020
Annual comprehensive maintenance of Fire Detection and Alarm System of Vidyasagar SGH, Behala, South 24 Parganas.
2026_WBPWD_5019449_1
WBPWD/EE-II/KSHED/T40/26-27
Open Tender
Support/Maintenance Service
Item Rate
365 days
Vidyasagar S G Hospital
Please refer Tender documents.
6 documents required · 6 mandatory
₹21,460
O/o EE, KSHED, P.W.Dte.
20 Aug 2026
20 Aug 2026
10 Sept 2026
20 Aug 2026
8 Sept 2026
26 Aug 2026
25 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Day to day preventive & corrective maintenance of the entire Fire Detection and Alarm system installed at the Vidyasagar S.G. Hospital by engaging 1 no. skilled person in each shift as given in Annexure-I having adequate knowledge in fire detection system as per terms & condition. | |||||
| 1.01 | Skilled Labour - Total 03 Shifts Per Day (01 No Per Shift) | 12 | Months | - | - |
| 2Replacement cost for following supply & installation of spare parts (Consumable spares & Emergency spares) as and when required for annual preventive and corrective maintenance of Fire Detection System. (As per attached Annexure II) | |||||
| 2.01 | Supply, Installation, Testing & Commissioning analog Addressable Intelligent multi sensor detector (VDS/UL/FM/ULC aproved) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable photo thermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard (Make: Siemens/Edwards) | 85 | Nos. | - | - |
| 2.02 | Supply, Installation, Testing & Commissioning Addressable Heat Detector (Fixed temperature cum rate of rise) ( VDS / UL / FM / ULC approved ) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard (Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Make: Siemens/Edwards) | 4 | Nos. | - | - |
| 2.03 | Supply, Installation, Testing & Commissioning Addressable Loop Powered Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC approved) approved. (Make: Siemens/Edwards) | 5 | Nos. | - | - |
| 2.04 | Supply, Installation, Testing & CommissioningAddressable Manual Call Point (VDS / UL / FM / ULC approved) soft addressable type within built fault isolator as per NFPA style 7 wiring complete as required. (Make: Siemens/Edwards) | 5 | Nos. | - | - |
| 2.05 | Supplying, installation, testing and commissioning of LED type Response Indicator (VDS / UL / FM / ULC approved) having 2 Nos. red coloured LED lamps including connections etc. (Make: Siemens) | 3 | Nos. | - | - |
| 2.06 | S&F of MCP Glass in place of damaged one | 10 | Nos. | - | - |
| 2.07 | S&F of 12 Volt, 12 AH SMF UPS Battery (FR Type) (Make: Exide/Amara Raja) | 2 | Nos. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.05 MB
termsandconditions.pdf
Additional Documents • 1.03 MB
TenderForm.pdf
Tender Documents • 0.69 MB
BOQ_5091820.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].