Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC AMBADI NEAR PAACHAKKIL BUS STOP MALAPARAMBA POST KOZHIKODE DISTT KERALA 673 009 | KOZHIKODE | KOZHIKODE | KERALA | 673009 | ₹1.2 Cr | L1 | Accepted-AOC BEING L1 AND REASONABLE |
| 2 | L2₹1.3 Cr+₹5.5 L (4.50%)Rejected-Finance KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | ₹1.3 Cr+₹5.5 L (4.50%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹1.4 Cr+₹23.1 L (19.0%)Rejected-Finance | ₹1.4 Cr+₹23.1 L (19.0%) | L3 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹99.7 L
EMD Value
₹1.7 L
Closing Date
26 Jul 2023, 6:00 pmClosed
Commander Works Engineer NB Kochi
Commander Works Engineer NB Kochi Kataribagh Naval Base PO Kochi 682 004
SPECIAL REPAIRS TO BLDG NO P-57 GYMNASIUM AT SMA RAMESHWARAM UNDER GE FORT KOCHI
2023_MES_596040_2
81091
Open Tender
Civil Works
Item Rate
180 days
SMA RAMESHWARAM
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
GE FORT KOCHI
₹1.7 L
Yes
25 Oct 2023
7 Jul 2023
29 Jul 2023
7 Jul 2023
26 Jul 2023
14 Jul 2023
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with screws complete all as specified and directed.
Dismantling framed work timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
Taking down chowkhat with shutter (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and directed.
Taking down chowkhat with shutter (without taking off shutters from the frames) exc 1.5 sqm each but n.exc 4 Sqm each complete all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of brick work/block masonry built in cement mortar complete all as specified and directed.
Dismantling of cast iron drain pipes, of any dia fixed to wall or laid under floors complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness laid bedded & pointed in any mortar in floors, aprons etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding, removing rubbish off the premises complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
M&L for precast concrete interlocking paver block, factory made, Machine pressed / vibro mechanically floated, any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with using grey cement & no pigment laid over and inluding 50mm thick 6.3mm graded stone chippings cushioning complete all as specified and directed.
M&L for precast cement concrete solid building blocks or slabs 10 cm thick 1:3:6 type C-1 (20mm graded stone aggregate) (with plain or interlocking joints as directed) setting in cement mortar 1:6, in walls complete all as specified and directed.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
M&L for Reinforced Cement Concrete type B1, 1:2:4 (using 20mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for TMT bars 6 to 8 mm dia, cut to length bent to shape required including cranking, bending spirally for hooping for slabs , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L TMT bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for slabs , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for flat surfaces and making the surface fair finished complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) in plinth protection, finished even and smooth w/o using extra cement complete all as specified and directed.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick with white cement and pigments, set, jointed and pointed in neat cement slurry in floors including 20mm thick screed bed or bedding in CM 1:4 for laying floor finishes complete all as specified and directed by Engineer-in-Charge.
M&L for wrought 1st class hard wood timber Fir/Spruce/Pine wood runners of 70 mm X 45 mm treated with anti-termite solution and fixed on the bottom side to support the flooring with 10 mm thick EPDM cushioning pads by nails through the two wings at 350 mm c/c complete all as specified and directed by Engineer-in-Charge.
S&F for Kiln Seasoned Teak Wood (Approved by Badminton World Federation And Certified by Labosport Grade 1 – EN 14904 As Per Badminton World Federation Standards) Surface board finished with 21 mm thick, 50 to 85 mm width and in random length in tongue and groove shape incl game line marking for 02 Nos Badminton court. The edges of the boards will have a finger lock grove and the bottom side with air pass groove. The Installation: A vapor barrier will be placed on the leveled IPS sub-floor before laying the under frame. The runners having air cell cushioning pads will be placed on the vapor barrier in perfect level at 350 mm c/c in one direction. The surface boards will be screwed to the runners through the tongue only and will lock the screwed tongue by the groove of the adjoining boards. The ends of the boards will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive. An expansion gap of 8 to 10mm will be left open between the wooden flooring and the surrounding tiled area/wall complete all as specified and directed by Engineer-in-Charge. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation.
M&L for Non skid Polyurethene Lacquer polishing of wooden floor including cleaning and preparing the surface by machine sander with floor sander machine including a coat of wood filler with two or more coats complete all as specifiedand directed by Engineer-in-Charge.
M&L for cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement complete all as specified and directed by Engineer-in-Charge.
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Dismantling single layer Mangalore pattern, or similar tiles, any size in roofing/ chajjas in small patches complete all as specified and directed by Engineer-in-Charge.
M&L for roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed by Engineer-in-Charge.
M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in lime mortar 1:3 or cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for mini MP tiles, of size 228x152mm, Mangalore pattern, interlocking at side joints, laid in 10mm thick CM 1:4 screed mixed with liquid water proofing compound complete all as specified and directed by Engineer-in-Charge.
Dismantling single layer Mangalore pattern or similar tiles in roofing/ chajjas in small patches and refixing it after replacing the broken tiles complete all as specified and directed by Engineer-in-Charge.
M&L for post construction anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by Engineer-in-Charge.
M&L for anti termite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed by Engineer-in-Charge.
S&F powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators, cup boards, partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engr-in-Charge.
S&F powder coated (minimum thickness of powder coating 50 micron) aluminium door shutters, partition aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, 2 Nos of tower bolt , hinges, aluminium snap beading screws etc. complete all as specified and directed by Engr-in-Charge.
S&F brass mortice lock, 4 levers, vertical type, size 100 mm with escutcheon plates, chrome handles and two keys to aluminium door shutter including all neccessary arrangements complete all as specified and directed by Engr-in-Charge.
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) window, cup board and ventilator shutters, fixed/ sliding type with/ without sash bar, aluminium section weighing 0.55 kg/m including necessary fittings like joining cleats, glazing clips, rubber packing, aluminium snap beading, handles and locking arrangements, screws, etc. complete all as specified and directed by Engr-in-Charge.
S&F standard aluminium deco grills (DG 101, 7 mm thick) including making arrangement for opening window, grill shall be fixed with suitable clip beading /clamps complete all as specified and directed by Engr-in-Charge.
S&F 4mm thick sheet/ float glass, ordinary quality and glazing fixed in aluminium window shutters, area n exc 0.5 sqm in each pane complete all as specified and directed by Engr-in-Charge.
S&F 4mm thick figured glass pin head type, fixed in aluminium window shutters, area n exc 0.5 sqm in each pane complete all as specified and directed by Engr-in-Charge.
S&F reflective glass, 5 mm thick, any approved colour and glazing to aluminium window/ door shutters, area of each pane exc 0.5 sqm complete all as specified and directed by Engr-in-Charge.
S&F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed by Engr-in-Charge.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge.
S&F in repairs aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed by Engr-in-Charge.
S&F 17.5mm thick solid plain PVC sheet suitably fixed as in shelves and partitions in cupboards with stainless steel screws and glue complete all as specified and directed by Engr-in-Charge.
S&F in repair curtain rods fancy type powder coated conduit not less than 18mm dia complete all as specified and directed by Engr-in-Charge.
S&F in repair fancy type powder coated bracket suitable for curtain rods fancy type powder coated conduit not less than 18mm dia complete all as specified and directed by Engr-in-Charge.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube complete all as specified and directed by Engr-in-Charge.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed by Engr-in-Charge.
S&F second class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engr-in-Charge. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation
S&F second class hard wood 35mm thick plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed by Engr-in-Charge. Note : Necessary preservation to timber shall be carried out all as specified and the rate quoted is inclusive of this preservation
S&F second class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu.cm each complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new or previously untreated wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-Charge.
S&F 150mm aluminium anodised handles, cast type complete all as specified and directed by Engr-in-Charge.
S&F 200mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed by Engr-in-Charge.
S&F medium weight, cold rolled, stainless steel butt hinges 100mm size complete all as specified and directed by Engr-in-Charge.
S&F 300mm size aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed by Engr-in-Charge.
M&L for preparing the surfaces and treating ends of posts, backs of chowkats, etc. with tar or coal tar black paint, area tarred exc 0.1 sqm but n exc 0.5 sqm each complete all as specified and directed by Engr-in-Charge.
M&L for preparing the surfaces and treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc.,with tar or coal tar black paint, area tarred n exc 0.1 sqm each complete all as specified and directed by Engr-in-Charge.
Dismantling posts or struts (wood, steel or R.C.C.) from concrete, brick work, masonry,etc. any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed by Engr-in-Charge.
M&L for 40mm thick cement concrete type B-1, 1:2:4, using 20mm graded aggregate as in flooring and making surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete 1:3:6, type C2 using 40mm graded stone aggregate as in foundations, filling, post holes and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for round or other steel section for posts including embeding in concrete and screwing etc. including all necessary drilling, welding, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new steel and iron surfaces of any description, over 10cm in width or girth,and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
M&L for surfaces of any description n exc 10cm width or girth when unconnected with other painting or when painted in different tint with a coat of pink primer and two coats of synthetic enamel paints complete all as specified and directed by Engr-in-Charge.
M&L for rendering 10mm thick in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for rendering 5mm thick in CM 1:3 on ceiling surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for rendering 8mm thick in CM 1:4 using liquid WPC over 12mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished even and fair without using extra cement at any floor complete all as specified and directed by Engr-in-Charge. Note: Water proofing compound shall be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed by Engr-in-Charge.
S&F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required and hold fasts confirming to Fe-290 Grade-E-165 complete all as specified and directed by Engr-in-Charge.
S & F in repair vitreous China wash basin, white, flat back, size 550x400mm or nearest available size as approved including pillar taps cat part No CON-021KN of Jaquar, waste coupling, chain and plug and including fixing with brackets, track, bolts etc. as per manufactures instructions complete all as specified and directed by Engr-in-Charge.
S & F in repairs PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engr-in-Charge.
S&F in repairs 32mm bore bottle trap of PTMT having minimum water seal of 25mm (minimum weight 32mm-260 gms/40mm-270 gms) complete all as specified and directed by Engr-in-Charge.
S&F 32mm bore Low Density Polyethylene Pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls,ceilings or in floors etc complete all as specified and directed by Engr-in-Charge.
Taking up or down 20 mm bore steel water tubing and connections including removal to store complete all as specified and directed by Engr-in-Charge.
Taking up or down 25 mm bore steel water tubing and connections including removal to store complete all as specified and directed by Engr-in-Charge.
Dismantling water tanks of capacity n exc. 1000 ltrs and removing to store complete all as specified and directed by Engr-in-Charge.
Supplying and laying of CPVC pipes of outer dia 20mm, SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including necessary fittings/ joints complete all as specified and directed by Engr-in-Charge.
Supplying and laying of CPVC pipes of outer dia 25mm, SDR 11 and plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including necessary fittings/ joints complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs, health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1mtr long easy flex tube and ABS wall hook including making connections and fixed in position complete all as specified and directed by Engr-in-Charge. Make:- Jaquar cat part No ALD-573 or equivalent from Cera/Parryware as approved by GE.
Supply and fix in repairs, soap dish any type fixed to plug with chromium plated fitted to walls with CP/ Brass screws complete all as specified and directed by Engr-in-Charge. Make:- Jaquar cat part No CAN-1177N or equivalent from Cera/Parryware as approved by GE.
S & F in repair brass chromium plated shower rose 125 mm dia with swivel joints and 190mm long SS arm rod including fixing to steel/ CPVC pipe or union complete all as specified and directed by Engr-in-Charge. Make:- Jaquar cat part No 483 & 495 or equivalent from Cera/Kohler as approved by GE.
S&F rotational moulded polyethylene water storage tanks, 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engr-in-Charge.
S&F in repairs chromium plated bib taps 15mm bore fancy type, screwed down, screwed for iron pipe/ CPVC pipe or for brass ferrule complete all as specified and directed by Engr-in-Charge. Make : - Jaquar cat part No CON-107KN or equivalent from Cera/Kohler/Marc as approved by GE.
S&F chromium plated single lever wall mixture with provision for overhead shower with 115mm long bend pipe on upper side, connecting legs and wall flanges complete all as specified and directed by Engr-in-Charge. Make : Jaquar Cat Part No CON-273KN UPR or equivalent from Cera/Kohler as approved by GE.
S&F in repair 25 mm bore gun metal globe or gate valve with iron wheel head screwed both ends for CPVC pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair 15 mm bore chromium plated fancy type stop cock (concealed type) screwed both ends for CPVC pipe or for unions complete all as specified and directed by Engr-in-Charge. Make : Jaquar Cat Part No ALD 069FT and CON-06FTK or equivalent from Cera/Kohler/Marc as approved by GE.
S&F ball brass valves high pressure with polythene float and fly nut complete screwed for iron/CPVC pipes of 20 mm dia or brass ferrule complete all as specified and directed by Engr-in-Charge.
S&F in repair, vitreous china urinal, half stall type, white, with 32mm bore waste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms), grating and union for discharge pipe, push tap suitable for urinals,any colour high pressure of PTMT screwed for iron pipe and fixed, (Minimum weight 15mm-47gms/ 20mm- 75gms) (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed by Engr-in-Charge.
S&F in repairs, stainless steel towel rail 600mm dia, chromium plated complete all as specified and directed by Engr-in-Charge. Make : Jaguar cat part No ACN1111SM or equivalent from parryware/Johnson as approved by GE.
M&L for providing cement concrete 1:2:4, type B-1, using 20mm graded aggregate as in hold fast bed block, coping, kerbs,etc complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete 1:2:4, type B-1, using 20mm graded aggregate as in ramp complete all as specified and directed by Engr-in-Charge.
M & L for 600 x 400 x 6 to7 mm thick glazed coloured ceramic tiles on vertical surface of wall, set and jointed in neat cement slurry over 10 mm thick screed bed in CM 1:3 and pointed in white/coloured cement to match the shade complete all as specified and directed by Engr-in-Charge.
M&L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding .11 sqm, in floors etc. set and jointed in neat cement slurry over 15mm thick screed bed in CM 1:4 and pointed in white/coloured cement to match the shade complete all as specified and directed by Engr-in-Charge.
M&L for polished black granite stone slab 18-20mm thick over 10mm thick backing coat in CM 1:3 on wall cladding/vertical surfaces with fasterners of stainless steel; including rounding of edges complete all as specified and directed by Engr-in-Charge.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with GI step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls/ laid in floors complete all as specified and directed by Engr-in-Charge.
S & F 75mm bore PVC (SWR) pipes single socketed in any length with GI step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls / laid in floors complete all as specified and directed by Engr-in-Charge.
S & F 75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed by Engr-in-Charge.
S & F 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed by Engr-in-Charge.
S & F 110mm bore PVC (SWR) bends any radius complete all as specified and directed by Engr-in-Charge.
S & F 75mm bore PVC (SWR) bends any radius complete all as specified and directed by Engr-in-Charge.
S & F 110mm bore PVC (SWR) vent cowl complete all as specified and directed by Engr-in-Charge.
M&L for chipping and removing all damaged and de bonded concrete and plaster from the RCC column, beam, flights, landing, railing and slabs by manually or mechanically so as to expose the corroded reinforcement bars including the rent of tools, scaffolding complete at any height and and removal of debris to a distance not exceeding 100mtr complete all as specified and directed by Engr-in-Charge.
Supply and application of rust remover/converter (Rebaklense RR of M/s Fosrock Chemicals India Ltd) or Amandur (Manufactured by GK Technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after application including the cost of all materials, rent of tools, scaffolding cost of brush etc complete all as specified and directed by Engr-in-Charge.
Supply and application of Nitozinc Primer (Manufactured by M/s Fosrock Chemicals India Ltd) over the exposed steel reinforcements after removing the rust scales from the exposed reinforcement rods in one square meter area including the cost of all materials rent of tools, scaffolding, cost of paint brush complete.
Supply and application of Nitobond EP (Manufactured by M/s Fosrock Chemicals India Ltd) epoxy bonding agent over the old concrete surface including the cost of all materials, rent of tools, scaffolding and cost of painting brushes etc complete all as specified and directed by Engr-in-Charge.
M&L for providing additional reinforcement bars in place of more than 1/3 corroded reinforcement bars including the charges for cutting, bending, placing and fixing in position using Lok-Fix E-55 (Manufactured by M/s Fosroc Chemicals India Ltd) including the cost of all materials rent of all accessories and tools, scaffolding and supporting materials, labour charges including the cost of steel bars complete all as specified and directed by Engr-in-Charge.
Supply and provisioning Renderoc RG non-shrink cementitious micro concrete (max 120 mm thick) (Manufactured by M/s Fosroc Chemicals India Ltd) to any thickness for beam and column. Fluid micro concrete shall be mixed with 6mm down coarse aggregate and specified quantity of water and mixed using a power operated slow speed stirrer and pouring inside the form work including the cost of all materials, rent for tools, scaffolding, and labour charges, water tight formwork etc. all as per manufacturer instructions complete all as specified and directed by Engr-in-Charge. Note for item Nos 106 to 111: The items shall be executed by manufacturer's agent for which manufacturer and contractor will give separate guarantee for five years.
Taking down unserviceable rolling shutter of any type of area exceeding 5 sqm but not exceeding 10 sqm including hood cover, servicing components such as shaft, spring, ball bearing, lathe, locking plate, guide channel, etc. ensuring smooth functioning and refixing the shutter in the same opening after servicing the components including greasing to all components complete all as specified and directed by Engr-in-Charge.
M & L for preparing newly plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified and directed by Engr-in-Charge.
M & L for preparing newly plastered surfaces of wall and applying two coats of acrylic distemper over a coat of cement primer and wall care putty ( minimum thickness 1mm) and priming coat complete all as specified and directed by Engr-in-Charge.
M & L for preparing newly plastered surfaces of wall & applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete as specified and directed.
M&L for preparation of old painted steel and iron surfaces of any description, over 10cm in width or girth, and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old treated surfaces of wall and applying one coat of acrylic distemper complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
M&L for preparing old decorated surfaces of ceiling and applying one coat of white wash on ceiling complete all as specified and directed by Engr-in-Charge.
M & L for preparing old treated surfaces of wall and applying two coat of antifungal exterior emulsion paint complete as specified and directed by Engr-in-Charge upto any height.
M&L for complete removal of existing treatment by mechanical manners and preparation and applying two coats of weather coat tile protektor by Berger paints or equivalent approved manufacturer to MP roof / chajjas tile surfaces over a coat of primer to a desired finish complete all as specified by manufacturer's instructions.
Removal of existing detoriated decayed tarfelt or any other treatment, loose surface and removing the debris to out side MD land to a distance exc 2.5 Km depositing where directed complete all as specified and directed by Engr-in-Charge.
M&L for rendering 10mm thick in CM 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement and using liquid water proofing compound on roof top complete all as specified and directed by Engr-in-Charge.
Material and labour for seven course Water Proofing Treatment over RCC slab by applying oil bound bitumen primer @ 0.25 Kg/Sqm. Provide and lay 4mm thick APP modified membrane not less than 4Kg/Sqm, reinforced with non woven polyester matt weighing not less than 160gms/Sqm having softening point not less than 140 degree centigrade, longitudinal tensile strength not less than 650N/5cm, tearing strength of 180N, a static puncture resistance of 180, keeping minimum 10cm side overlap and 15cm end overlap by torch application over a coat of blown grade hot bitumen grade 85/25 conforming to IS : 702 heated to a working temperature of 180 degree centigrade and applied @ 1.2Kg/Sqm of the surface area. Apply a coat of blown type bitumen and 4mm thick APP membrane (both as per above specification) over the above layer. Apply a coat of blown type bitumen (as per above specification) and and finishing surface with solar reflective bituminous aluminium paint @ 0.10 Kg/ Sqm complete all as specified and directed by Engr-in-Charge. Notes: (a) 10 yrs gaurantee certificate to be submitted by the contractor. (b) Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency/applicator which will further have to rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
M&L for preparation of new tiles and applying two coats of weather coat tile protektor by Berger paints or equivalant approved manufacturer to MP roof / chajjas tile surfaces over a coat of primer to a desired finish complete all as specified by manufacturer's instructions.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or taking credit and making good the disturbed surfaces of walls, floors, etc complete all as specified and directed by Engr-in-Charge.
Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into existing rigid non-metallic PVC conduit pipe in wall/surface complete for one light / fan point controlled by one, one way switch 06 Amps complete all as specified and directed by Engr-in-Charge.
All as per srl item No 127 here-in-before but for one bell controlled by one bell push, 06 Amps, single pole, one way point complete all as specified and directed by Engr-in-Charge.
All as per srl item No 127 here-in-before but for one 3 pin socket outlet, 05 Amps, independent with cable 1.5 sqmm size complete all as specified and directed by Engr-in-Charge.
All as per srl item No 127 here-in-before but for one 3 pin socket outlet, 05 Amps on same board with other switches with cable 1.5 sqmm size complete all as specified and directed by Engr-in-Charge.
All as per srl item No 127 here-in-before but for one 3 pin socket per outlet, 15 Amps, independent with cable 2.5 Sqmm size complete all as specified and directed by Engr-in-Charge.
Material and labour for point wiring in casing and capping on surface on wall, ISI marked of suitable size with 1.5 Sqmm PVC insulated unsheahed stranded copper conductor cable, single core, 1100 volts grade as per IS colour code, with pressed steel terminal boxes of suitable sizes and 1.6mm thick, duly painted inner and outer side for mounting switches, sockets, fan regulator etc with 1.6mm thick plastic laminated sheet cover with brass screw, cup washer and including PVC insulated and unsheathed stranded copper conductor of size 1.5 sqmm as continuous earth wire complete for one light point controlled by one switch complete all as specified and directed by Engr-in-Charge.
All as per srl item No 132 here-in-before but for one 3 pin socket outlet, 05 Amps on independent board with cable 1.5 sqmm size complete all as specified and directed by Engr-in-Charge.
All as per srl item No 132 here-in-before but for one 3 pin socket per outlet, 15 Amps on independent board with cable 2.5 sqmm size complete all as specified and directed by Engr-in-Charge.
Supply and fixing switch piano, flush type, single pole, one way, 5 Amps complete all as specified and directed by Engr-in-Charge.
Supply and fixing switch socket combination outlet multipurpose 2 in 1, 5 pin, 6 Amps and 2 pin 6 Amps flush type complete all as specified and directed by Engr-in-Charge.
Supply and fixing switch socket combination outlet multipurpose , 6 Amps and 16 Amps flush type complete all as specified and directed by Engr-in-Charge.
Supply and fixing socket outlet multipurpose 2 in 1, 5 pin, 5 Amps and 2 pin 5 Amps complete all as specified and directed by Engr-in-Charge.
Supply and fixing ceiling rose PVC poly carbonate, isolated body with two to three terminals including connection complete all as specified and directed by Engr-in-Charge.
Supply and fixing lamp holder, PVC/Poly carbonate type, with cord grip cap suitable for pendent/batten/angle fittings along with LED bulb complete all as specified and directed by Engr-in-Charge.
Supply and fixing bell push, flush type, 5 Amps complete all as specified and directed by Engr-in-Charge.
Supply and fixing bell Ding Dong AC. 230 volts, single pole complete all as specified and directed by Engr-in-Charge.
Disconnection of electrical wire from ceiling rose, taking down ceiling fan of any type 1200 mm sweep and any make, dismantling the ceiling fan for rewinding including replacement of bearing/bushes etc without causing any damage and refixing same location after complete the necessary repair work complete all as specified and directed by Engr-in-Charge.
All as per srl item No 143 here-in-before but for exhaust fan of size 300mm sweep complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of surface mounted LED integrated batten, 20 Watt, with IP 20 protection comprises of aluminium extruded channel, extruded aluminium body, integrated electronic driver, etc and all accessories pre-wired including connecting up complete all as specified and directed by Engr-in-Charge.
All as per srl item No 145 here-in-before but for10 watts 2 feets LED light fittings complete all as specified and directed by Engr-in-Charge.
Taking down existing LED tube light fitting with connected accessories any type / wattage and refixing the same with mounting accessories without causing any damage complete all as specified and directed by Engr-in-Charge.
Supply and fixing highbay LED luminaire 80 Watts with driver, single phase 90 degree angle luminous complete including taking down old unserviceable halogen lamp complete all as specified and directed by Engr-in-Charge.
Supply and fix heavy exhaust fans AC turbo jet single phase 230/ 240 V of size 300mm sweep 1400 RPM with louver including taking down old unserviceable exhaust fan keep on aside and hand over to MES store complete all as specified and directed by Engr-in-Charge.
Taking down carefully copper/aluminium submain wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors, roofs etc complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring with 2 runs of 6 sqmm PVC insulated unsheathed 1100 volt grade multistranded copper conductor including conduit of suitable size and provision of one runs 6 sqmm PVC insulated unsheathed single core copper conductor as earth continuity , connected to earth dolly inclusive of all accessories complete all as specified and directed by Engr-in-Charge.
Material and labour for wiring for circuit / sub main wiring with two runs of 4.0 Sq mm alongwith one run of 4.0 Sq mm earth wire of FRLSH PVC insulated copper conductor, single core cable drawning into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into/on wall where as possible by cutting of chases and making good to the disturbed surfaces to match the existing complete all as specified and directed by Engr-in-Charge. Note : (1) Two runs of cable, one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
S&F MCB TPN, DB 4 ways, 415 volts double door type complete all as specified and directed by Engr-in-Charge.
S&F in repair sheet metal enclosure DB SPN AC 240 Volts, 8 way with 200 Amps rated bus bar, double door type complete all as specified and directed by Engr-in-Charge.
S&F in repair sheet metal enclosure DB SPN AC 240 Volts 4 way with 200 Amps rated bus bar, double door type complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of MCB, TPN, AC, 415 volts of 63 Amps capacity complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of MCB, SP, AC, 240 volts of 06 to 32 Amps capacity complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair of MCB, DP, AC, 240 volts of 40 Amps capacity complete all as specified and directed by Engr-in-Charge.
Supply, install, testing and commisioning of roof top mounted air operated turbo ventilator fully stainless steel body, incl base plate of suitable thickness, turbo fan with not less than 42 fins including cutting hole on existing GI roof top without causing any damages and all fixing accessories including leak proof arrangements complete all as specified and directed by Engr-in-Charge. Note : The quoted rate shall deemed to be included making hole/any small alteration in GI roof and provision for arresting leakages complete.
Taking down old GI/Al strip any size with connecting accessories like insulator, screws etc complete all as specified and directed by Engr-in-Charge.
Supply and fix air termination, single pointed, aluminium rod 12 mm dia and 300 mm long complete all as specified and directed by Engr-in-Charge.
Supply and fix galvanised iron strip 32 x 6 mm buried in ground /fixed on wall complete all as specified and directed by Engr-in-Charge.
Supply and fix aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 'light grade' galvanised iron tubes 40mm bore with all fitting and fixed to walls/laid in floors/trench complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 'light grade' galvanised iron tubes 20mm bore with all fitting and fixed to walls/laid in floors/trench complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including all fixing accessories in SMC enclosure/junction box complete all as specified and directed by Engr-in-Charge.
M&L for pre-cast cement concrete 1:3:6, type C1 using 20 mm graded stone aggregate as in block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick, buried directly in set ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel Gl protection pipe 15mm bore light grade all as shown in electrical plate No 3 of SSR part 2009 and connected to main switch board / Main DB's including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, Gl pipe medium grade 20mm nominal bore watering pipe, GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete all as specified and directed by Engr-in-Charge.
All as per srl item No 168 here-in-before but connected to 32x6mm Galvanized iron strip complete all as specified and directed by Engr-in-Charge.
Material and labour for wiring for circuit / sub main wiring with two runs of 2.5 Sq mm alongwith one run of 2.5 Sq mm earth wire of FRLSH PVC insulated copper conductor, single core cable drawning into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into/on wall where as possible by cutting of chases and making good to the disturbed surfaces to match the existing complete all as specified and directed by Engr-in-Charge. Note : (1) Two runs of cable, one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
MS BUILDERS
JKM CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .