| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹4.0 L+₹6,329.65 (1.60%)Rejected-Finance NAMO PARA BAKULTALA LANE PURULIA 723103 | PURULIA | PURULIA | WEST BENGAL | 723103 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹4.0 L+₹8,833.62 (2.23%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹9,000
Closing Date
3 Jun 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer, PMD,PHE.Dte
Office of the Executive Engineer Purulia Mechanical Division,PHE.Dte Ranchi Road,Purulia.
Providing yard lighting and other related works at OHR Zone-II of Arsha water supply scheme under Purulia Mechanical Division PHE Dte.
2025_PHED_846455_4
03 /EE/PMD/PHED OF 2025-2026
Open Tender
MECHANICAL
Item Rate
60 days
Purulia
Please refer Tender documents.
5 documents required · 5 mandatory
₹9,000
Yes
17 Jul 2025
16 May 2025
5 Jun 2025
16 May 2025
3 Jun 2025
16 May 2025
Amount
Supply & Delivery at site 7 mtr. Conical/ Cylindrical GRP street light pole made by CNC filament machine using Thermoset resin having minimum 65% glass containt in one piece with straight non decorative GRP single arm of 1000 mm and internal junction box (6A SP MCB & 4 way connector). Top 85 ±2mm ID and bottom 176 ±2mm ID. (Make- PHED Approved make)
Construction of RCC foundation volume not less than 0.4 cum in portion 4:2:1 and Ø10 and Ø8 TOR including provision of cable entry in Pole junction box and neatly cemented finish (3mm thick) above ground level.
Erection of 7 mtr pole on RCC foundation.
Supplying and fixing 415V, 32 Amp TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating on flat iron frame, make: L&T/ approved make
Supplying and Delivery 1.1 KV grade 3.5 core 25 sq. mm XLPE insulated Al. Armoured cable for connection from WBSEDCL meter room to main Switch. (Make: PHED Approved make)
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supply and delivery at site of 1.1 KV grade 2 core 6 sq.mm XLPE insulated Al. Ar. Cable Conforming to IS:7098(Part-I) 1988.
Laying of one No. cable of 1.1 KV grade 2 core 6 sq.mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of cable of 1.1 KV grade 2 core 6 sq.mm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting.
Supply & Storage of 60 watt LED fixtures of approved make with IP66 protection, PDC housing with finless design and polycarbonate cover(IK08). Pole dia. 48-60 mm.
Supply and fitting fixing of Street Light Panel (Conforms to IS/IEC 60947-4-1 ) with following specification: Maximum load : 6 kW, Provided with Protection Degree IP 54, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, Digital 24 hour timer, Contactor Rating (A)-32 A TP, MCB Rating-40 A TPN including fixing on MS angle frame with S & F all necy with complete the power connection and earthing connection.
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 4 Way
Supply, delivery and fitting fixing of 40 Amp. 30 mA DP RCCB with IS 12640-1 & IEC 61008-1) 240 V, 50 Hz with 10 kA short circuit withstand capacity on exsisting SS enclosure.
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. (i) 2 x 56/0.3 (4 sqmm) + 1 x 22/0.3 (1.5 sqmm)
Supply & Storage of FRLSH PVC insulated 1.5 sqmm industrial grade copper conductor unsheathed flexible cables 1.1 KV confirming to IS 694.
Supply & Fixing including 40 mm dia GI Pipe with die cast aluminium housing of gate light 1x40watt LED outdoor luminaire (make-CGL-LP-TO-40 CDL/ similar spec. of other approved) Milk White decorative post top for 360° indirect light IP 65 protection Resistant to impact and corrosion as per direction of EIC.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry 1.1 KV Gr. 2 core 6 sq.mm XLPE Armored Al. Cable.
Finishing the end of the same by crimping method incl. supplying and fixing solderless socket (Dowels make) tapes, anticorrosive paste & jointing materials. 2 core 6 sqmm cable.
Earthing with 1 no. of G.I. earth spike (20 mm dia x 1.5 mtr. Long) driven into the ground upto 2 mtr. Drawing earth one with separate 6 SWG G.I. Wires providing 15 mm dia G.I. pipe protection from earth spike feeder box/ junction box/ poles and fixing to the same by suitable nuts & bolts all commette as per direction of EIC.
Fixing of Street light fittings with suitable tie clamps & MS Plate for mounting on pole / tower and connecting necessary wires including hiring charges of ladder and other incidential charges.
Testing & commissioning the whole installation up to the entire satisfaction of the EIC.
Add GST @ 18%
Add CESS @ 1%
BISHWANATH NANDI (BID ID -6494094)
TAPAN KUMAR DEY (BID ID -6467982)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .