Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Addl. Chief Engineer cum Director, PWD BTC
O/o the Addl. Chief Engineer cum Director, PWD BTC, Kokrajhar
Infrastructure Development of Elementary and secondary school under BTR at Goria Pather LP School in Udalguri District for the financial year 2021-22.
2022_BTC_24365_1
ACE-35/TECH/UDL(RB)/IFB/18-19
Open Tender
Civil Works
Works
120 days
Udalguri District
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Principal Secretary, BTC, Kokrajhar
₹53,582
Yes
16 Mar 2022
17 Feb 2022
28 Feb 2022
17 Feb 2022
28 Feb 2022
17 Feb 2022
17 Feb 2022 - 28 Feb 2022
180 days
Amount
23.12. : Dismentaling all type of corrugated tropozoidal sheet roofing including riding etc. complete valy and gutter ... skirting etc. complete as directed by the deptt.
39.9.: Dismantaling wood work in frame truss purlins and rafter including staking etc. etc. complete as directed by the department.
23.15. : Demolising C.C. floor of various thickness including top layer and base course and disposal etc. complete.
23.18. Dismentaling and removing the existing door and windows frame (chowkath) both wooden and steel of different size .. (i) Area of door/window upto 3.00 m2
4.1.1.: Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materialsand if necessary dewatering, complete. (a) Brick on flat Soling.
5.1.3.: 40mm thick cement concrete floor consistiong of 25mm under layer of cement concrete in prop. 1:3:6 and 15mm thick wearing layer etc. etc. complete as directed.
6.2.1 : 10mm thick cement plaster in single coat or single coat on fair side etc. etc. complete b) In cement mortar 1:4
7.10.1: Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm /1200mm x 600mm with main runner 38 x 24mm cross tee 29mm x 24mm & wall angle 24mm x 24mm etc. A) Standard Ceiling of Everest make or equivalent as directed by the department i) Using 4mm thick F.C. board
8.1.37: Providing Bore galvalume sheet roofing at all levels including fitting and fixing self drilling self tapping etc. etc. complete. (iii) 50mm thick
8.1.38 : Providing Bore galvalume sheet roofing Ridging etc. etc. complete ii) 0.50mm thick
9.1.2.: Providing wood work in frame chowkath of doors/windows clerestory windows and other similar work etc. complete b) With 1st Class timber
9.9.4.: Providing fitting and fixing Ist class local wood battens framed and braced door and windows sheet celing oxidised etc. complete. A) Using Bansum/Hollock wood.
9.9.9. Providing fitting and fixing fully glassed clerestory window and from hight including fitting etc. complete 2 M.S. pivol hings etc. complete etc. B) With Gamari/Hollock/Bonsum wood ii) 35mm thick
9.2.1. : Providing undressed wood work in roof truss etc etc. complete b) With Hollock/Sundi/Sam
9.4.1: Providing barge board of size 200mm of size 200mm x 25mm with 1st class wood Hollock/ Bonsum timber including fitting and fixing with necessary etc... Complete.
10.4 Extra for providing Security grill welded casement window, Ventilator etc. etc. complete ....
15.2.1: Supllying fitting and fixing avodised alluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects ... etc. complete as directed. (a) Sliding door bolt (i) 300mm x 16mm
(b) Tower bolt (iii) 300mm X 12mm
(c ) Door handle (iii) 150mm
16.1.: Providing, fitting and fixing clear sheet glass beded in putty and.... i) Area of glass panes not exceding 0.15 m2
13.2.3: (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.2.3: (b) Finishing wall with water proffing paint etc. etc. complete
19.3: Providing plinth protection with brick flat laid brick flat laid in cement mortar 1:4 and finished 15mm thick cement plaster in prop. 1:2 with a flating coat of neat cement finish.
19 5: Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plasterin in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc as specified i) 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
Repair/Renovation of Class Room 23.12 Dismentaling all type of corrugated tropozoidal sheet roofing including riding etc. complete valy and gutter….. Skirting etc. complete as directed by the deptt.
39.9 Dismantaling wood work in frame trus and rafter including staking etc. etc. complete as directed by the department.
3.15. : Demolising C.C. floor of various thickness including top layer and base course and disposal etc. complete
23.18. Dismentaling and removing the existing door and windows frame (chowkath) both wooden and steel of different size .. (i) Area of door/window upto 3.00 m2
4.1.1.: Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materialsand if necessary dewatering, complete. (a) Brick on flat Soling
1.3.: 40mm thick cement concrete floor consistiong of 25mm under layer of cement concrete in prop. 1:3:6 and 15mm thick wearing layer etc. etc. complete as directed.
6.2.1: 10mm thick cement plaster in single coat on fair side etc. etc. complete. b) In cement mortar 1:4
7.10.1: Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm /1200mm x 600mm with main runner 38 x 24mm cross tee 29mm x 24mm & wall angle 24mm x 24mm etc. A) Standard Ceilin
8.1.37 : Providing Bore galvalume sheet roofing at all levels including fitting and fixing self drilling self tapping etc. etc. complete. (iii) 50mm thick.
8.1.38 : Providing Bore galvalume sheet roofing Ridging etc. etc. complete ii) 0.50mm thick
9.1.2.: Providing wood work in frame chowkath of doors/windows clerestory windows and other similar work etc. complete b) With 1st Class timber
9.9.4. : Providing fitting and fixing 1st class local wood battens framed and braced door and windows sheet celing oxidised etc. complete. A) Using Bansum/Hollock wood.
9.9.9.: Providing fitting and fixing fully glassed clerestory window and from hight including fitting etc. complete 2 M.S. pivol hings etc. complete etc. B) With Gamari/Hollock/Bonsum wood ii) 35mm thick
9.2.1. Providing undressed wood work in roof truse etc, etc, complete b) With Hollock/Sundi/Sam
9.4.1: Providing barge board of size 200mm X 25mm with 1st class wood Hollock/ Bonsum timber including fitting and fixing with necessary etc... Complete
10.4.: Extra for providing Security grill welded casement window, Ventilator etc. etc. complete...
15.2.1 Supplying fitting and fixing avodised alluminium fittings of approved make resonably smooth, free from sharp edges and corners, flows and other defects…… (a) Sliding door bolt (i) 300mm X 16mm
(b) Tower bolt (iii) 300mm X 12mm
(c ) Door handle (iii) 150mm
16.1 Providing, fitting and fixing clear sheet glass beded in putty and.... i) Area of glass panes not exceding 0.15 m2
13.2.3: (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.2.3: (b) Finishing wall with water proffing paint etc. etc. complete
19.3: Providing plinth protection with brick flat laid in cement mortar 1:4 and finished 15mm thick cement plaster in prop. 1:2 with a flating coat of neat cement finish.
19.5.: Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C. (1:3:6) base over one brick flat soling including 15mm thick cement plasterin in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc as specified. i) 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
RCC Latrine & Urinal 1.1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completetion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil.
4.1.1.: Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick on flat Soling
2.1.1. Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing stepts, walls brick works etc. as directed and specified including dewatering if necessary and curing complete (Shutering where necessary shall be measured and paid separately) (a) In prop 1 cement: 3 sand : 6 coarse aggregate by volume
18.1.1. : Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the in the measurement as they are included in the rate) (Upto 1st floor level) (a) ISI approved Super Ductile (SD) TMT reinforcement bars.
3.2.1.: Providing form work of 12mm thick plywood board so as to give a rough finish including centering shuttering, strutting and propping etc. 3.1.1.1. Column, pillars posts & struct of square/rectangular/ Polygonal in plain ar any shape like Tee/L etc.
3.1.1.2. : Sides and soffits of beam. beam haunchings, cantilever girders bressumers, lintels and horizantal ties. a) For depth not execeding 1.00 M
3.2.1.3. : Flat surface such as soffits of suspended floors roof landing slab Chajja etc. a) Floor etc. upto 200mm in thickness.
2.2.1.: Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinfor cement for reinforced cement concrete work (from work and reinforcement will be measured and paid separately) (1) Using Mixture Machine (A) Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, ......than 100mm thick up to plinth level. (N) Without using admixture, plasticiser (b) M20 grade concrete or prop. 1:1.5:3
(b) In super structure from plinthlevel. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, belcony, lintel, sill bend, beam girder....... and finishing (N) Without using admixture, plasticiser (b) M20 grade concrete or prop. 1.1.5.3
4.1.4: Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed. (i) In sub-structure upto plinth level including dewatering if necessary. b) In prop. 1:4
1.3: Earth/ sand filling in plinth layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading
2.1.3: Providing and laving 25mm thick damp proof course with cement concrete in prop. 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc. complete as directed.
1.8: 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth upto 1st floor level (protruding M.S. rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) A) 112mm thick brick wall (a) In cement mortar in proportion 1:4 (1 cement : 4 sand)
12.1: Providing fitting and fixing 40mm x 48mm wood reinforced PVC chowkats fixed to the column/stiffeners/wall with necessary holdfast etc.
18.5.4 Providing fitting and fixing steel ventilators (openable) of standard rolled steel sections as per relevant I.S. Code etc.
10.2: Providing, fitting and fixing M.S. grill of required for windows/clerestory window/Opening with M.S. flat at required spacing in frame all round, square or round handed bolts and nuts or screws. (C ) Fixed to Brick work/PCC/RCC
6.2.2.: 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arise, internal roundred angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side b) In cement mortar 1:4
B) On tair side b) In cement mortar 1.4
5.1.10 Cement plaster skirting with cement moratr in prop. 1.3 finished with a floating coat of neat cement etc. a) 15mm thick.
2.1.2: Plain cement concrete floor base in prop. 1:3:6 laid in alternate bays as specified with coarse agg of size 13mm to 32mm including etc. (ii) 50 mm thick
5.11.1: Providing Antiskid Tiles of approved quality, size, shape and thickness not less than 8mm on floor, skirting etc. (A) CERAMIC (ii) Executive range-1 (size 400mm x 400mm and above) (a) Somany made-VC Shield (Group-25) (406 x 406) mm Deluxe - VC
5.7.1.2: Providing Ceramic Tiles of approved quality, size shape and thickness not less than 8mm on wall, skirting etc. B) Executive range (Somany/Orient/Nitco/Asian make) ii) Of size 250mm x 350mm and above
12.2.: Providing and fixing 24mm/29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws etc b) 29mm thick.
16.1 Providing and fixing clear sheet glass beded in putty and fixed with/without wooden bedings etc. (i) Area of glass panes not existing 0.15 m2 © 3.00 mm thick.
19.2 Providing plinth protection with brick flat laid in cement mortar 1:4 and finished 15mm thick cement plaster in prop. 1:2 with a flating coat of neat cement finish.
19.5 Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C. (1:3:6) base over one brick flat soling including 15mm thick cement plasterin in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work..... ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
13.4.7: Wall painting (two coats) with plastic emulsion paint approved brand and manufacture (Asian paint/Berger etc. to give an even shade etc. a) Plastic emulsion paint approved brand and manufacture (Asian paint/Berger Paint/ICI paint/J&N paint/Nerolac)
13.9.1: Finishing old/new wall with water proofing weather coat Smooth anti-fungal exterior painting of Apex brand of Asian paints of required shade etc.
Providing of Tube well plateform with brick work. CC work plastering etc.
SANITARY FITTINGS AND WATER SUPPLY 1.13 Providing fitting and fixing white vitreous water closet squatting pan (India type pattern) of size 580 x 240 mm with 100mm SCI 'P' or 'S' Trap of Parrywarel Hindware etc.
1.8 Providing, fitting and fixing vitreous china back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions etc. complete. A) Partyware Make a) White iv) Flat Back (Cat No. C051/72)
1.37.1_ Supplying fitting and fixing P.V.C. pipe of 6 kg/cm2 (Supreme/Prince) of other ISI approved including Joining, fitting and fixing with clamps etc. complete. a) Exposed Surfaces or in tranches ii) 110mm dia
(vi) 75mm dia
1.37.2: Supplying fitting and fixing 87.5 degree PVC bend (Supremel Prince) of other ISI approved including Joining, fitting and fixing with clamps etc. complete. a) Exposed Surfaces or in tranches ii) 110 mm dia
(ii) 75mm dia
1.37.6: Supplying fitting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including Joining and fixing with clamps etc. b) Concealed by chiseling or breaking brick wall/CC/RCC and making good to the damages iv) 110mm dia
1.37.14 Supplying fitting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including Joining and fixing with Clamps etc. (a) In exposed surfaces or in trenches (iv) 110mm X 75mm
1.39: Providing, fitting and fixing PVC cowel of ISI marked complete as directed and specified. (iv) 75mm dia, PVC cowel of ISI make.
1.51 Construction of filter bed in sock pit including earth work in excavation of soil and then filling up of the trench with brick bats/charcoal with earth over a layer of A.C. plain sheet etc. etc. ...... complete.
1.52: Construction of inspection pit of inside measurement 450 x 450 mm x 450mm flush with 100mm dia. HCI/PVC pipes and cement concrete base in prop. 1:3:6 over wat brick soling etc. etc.
5.1.1 Supplying fitting and fixing pipes with all necessary fittings in exposed or in trenches etc. (A) G.I. pipes with G.I. fittings a) TATA/SAIL (Medium) 40mm dia
5.3.8. : Supplying fitting and fixing brass Tez filter 2.00m long
5.3.1. Labour for sinking tube well with 40mm (internal) dia G.I. pipes upto to havings strata, having etc.
5.3.2.: Supplying fitting and fixing Maya Hand Pump No. 6 for 40mm dia Tube Well etc. ii) Mayur
SEPTIC TANK 1.1 Earth work in excavation for foundation trenches of walls, relating walls, footing of column, steps septic (A) Up to a depth of 2m below the existing G.L. (a) in ordinary soil.
4.1.1 Providing soiling in foundation and under floor with stone/ best quality Jhama bricks and packed etc. etc. (a) Brick flat soiling
2.1.1 Plain cement concrete work with coarse agg. Of size 13 mm to 32 mm in foundation bed for flooring step wall etc. etc. b) In prop. 1:3:6
18.1.1 : Supplying fitting and fixing in position reinforcement bars Conforming to relevant IS code etc. etc. ((a) other ISI approved T.M.T. reinforcement bar (SRMB/ BISCONIX TECH)(For Assam Type Bldg, drain, B. wall etc) 10 mm dia
3.2.1 Providing from work of 2mm thick Plywood Board. so as to give a rough finish incl. centering shuttering etc... 3.2.1.1 Column, pillars, posts & strut of squarel rectangular etc.
2. Sides of tie beam, plinth beam, grade beam etc
4.14 Brick work in cement mortar with 1st class brick incl. raking out joints and dewatering in sub structure. (b) In Prop 1:4
2.2.1. Providing and laying plain/reinforced cement concrete work With coarse sand and 20mm down graded stone etc (a) In substructure up to PL foundation, footing, column With base tie and plinth beam etc. (a) M 20 of Prop 1:1.5:3
6.2.2. 15mm thick cement plaster in single coat on rough side Of brick/ concrete walls for interior plastering up to 151 floor level etc. (a) in prop 1:3
25.12 Providing precast RCC slab in prop. 1:2:4 reinforced With 10mm TMT/HYSD bars @ 150mm cement both Ways tying with 20 gauge black annealed etc. etc.
SANITARY FITTINGS 1.37.5 Providing fitting and fixing plain single tee of (Supreme/ Prince) or other ISI approved etc (b) Concealed by sheselling or braking brick wall etc. (ii) 100 mm dia..
1.48 Providing fitting and fixing 150mm dia 90mm thick Cl manhole covered frame of 25kg weight etc.
ELECTRICAL WORK Existing School Building 1.8 :- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. Copper conductor single core cable etc. as required. 1.8.1 Group A
1.8.2 Group B
1.14 :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 x 2.5. sq. mm + 1x 2.5 sq. mm earth wire
1.14.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
1.24 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch
1.24.4 3pin 5/6 socket outlet
1.34 :- Supplying and fixing brass batten/ angle holder including connection etc. as required.
2.3 Supplying and fixing following way, single pole and natural, shee steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.1 6 way, Double door.
2.10 :- Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Sing pole
2.12 Supplying and fixing following rating double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.1 40A
5.17 Providing and fixing 4.00m dia copper wire on surface or in recess for loop erthing as required.
MR-1:- Supplying with including fitting fixing Of ceiling fan etc. as directed by the Deptt.
MR- 2:- Supplying with including fitting & Fixing of LED Tube Light etc. as directed by the deptt.
MR - 3 Supplying with including fitting fixing of LED Bulb 9 Watt. Etc. as directed by the Deptt.
ELECTRICAL WORK Repairing of class Room 1.8 :- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. Copper conductor single core cable etc. as required. 1.8.1 Group A
1.8.2 Group B
1.14 :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 x 2.5. sq. mm + 1x 2.5 sq. mm earth wire
1.14.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
1.24 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1 5/6 A switch
1.24.4 3pin 5/6 socket outlet
1.34 :- Supplying and fixing brass batten/ angle holder including connection etc. as required.
2.3 Supplying and fixing following way, single pole and natural, shee steel, MCB distribution board, 240V, on surface/recess, complete with tinned copper bus, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.1 6 way, Double door.
2.10 :- Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Sing pole
2.12 Supplying and fixing following rating double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.1 40A
5.17 Providing and fixing 4.00m dia copper wire on surface or in recess for loop erthing as required.
MR-1:- Supplying with including fitting fixing Of ceiling fan etc. as directed by the Deptt.
MR- 2:- Supplying with including fitting & Fixing of LED Tube Light etc. as directed by the deptt.
MR - 3 Supplying with including fitting fixing of LED Bulb 9 Watt. Etc. as directed by the Deptt.
Puran Daimari
Jwhwlao Boro
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .