Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹9.6 L+₹3.6 L (58.7%)Rejected-Finance | L2 | Rejected-Finance Reject | |
| 3 | L3₹12.5 L+₹6.4 L (106.3%)Rejected-Finance OPPOSITE VIPUL GAS AGENCY HOSPITAL ROAD SOLAN H P | SOLAN | SOLAN | HIMACHAL PRADESH | L3 | Rejected-Finance Reject | |
| 4 | L4₹13.6 L+₹7.5 L (124.5%)Rejected-Finance NEAR AVN HOSTEL NAHAN TEHSIL NAHAN DISTT SIRMOUR HP | NAHAN | SIRMOUR | HIMACHAL PRADESH | L4 | Rejected-Finance Reject | |
| 5 | L5₹15.4 L+₹9.3 L (154.6%)Rejected-Finance | L5 | Rejected-Finance Reject |
Tender Value
Refer Docs
EMD Value
₹13,000
Closing Date
27 Feb 2023, 11:00 amClosed
Executive Engineer Jal Shakti Division Nahan
Executive Engineer Jal Shakti Division Nahan
Providing and installation of submersible pumping machinery with allied accessories
2023_HPIPH_69015_1
NHN-SMROO-722- 18229-289 dt 15-02-23
Open Tender
Pumps/Motors
Item Rate
90 days
Dadahu
Please refer Tender documents.
12 documents required · 12 mandatory
₹250
Executive Engineer Jal Shakti Division Nahan
₹13,000
Yes
12 Jul 2023
16 Feb 2023
27 Feb 2023
16 Feb 2023
27 Feb 2023
16 Feb 2023
Amount
BOOSTER STAGE
Supply, erection, testing & commissioning of submersible pumping set of reputed make KSB /BS/Johnston/ Worthington / Sabar/ Oswal conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor . The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:-
Total Head in mtrs (i/c depth of Column Pipe in case of T/well) :- 20mtrs
Capacity (in LPS) :- 15.82 LPS
Dia of R/Main (in mm) :- 150 mm.
Dia of Column Pipe (in mm) :- 150 mm.
Length of R/main :- 60mtrs
HP:- 2X7.50HP = 15 HP
SITE CONDITIONS :-
Location of Site :- To be filled by Engineer Incharge
The altitude of place in which the motor is intended to work :- 500 mtrs
Humidity :- Wheather generally remains humid during monsoon season
Nature of atmosphere :- As normally encountered in Shivalik Ranges
Detail of quality of water :- Clear water
Water free from sand or not :- Free from sand.
Water corosive or not :-
Turbidity :- Clear water.
Type of well :-
Inside Dia of Well :- ----
Depth of water during HFL in the pond :- To be filled by Engineer Incharge
Max. draw down :- ------
Depth of well :- ------
Any other information or requirement :- ------
OPERATING CONDITIONS :-
Type of current :- AC three
Operating frequency :- 50 HZ
Rated voltage :- 400 (+/-) 10% volts
System of earthing if any to to be adopted :- Double loop earthing as per BIS 3043-1987 latest with upto date ammendments
Speed of revolution :- To be quoted by Tenderer
Direction of rotation :- To be quoted by Tenderer
No. of working hours per day :- 4hours
The max. Temp. of cooling air & water in the place in which the pumpset is intented to work in ordinary service :- 35 Degree Centigrade
MOTOR :-
Ref to BIS code :- BIS 9283-1979 or latest with upto date ammendments
Type of enclosure of motor :- As per BIS 4691-1985 or latest with up to date ammendments
Type of duty :- S1 i.e. Continuous duty type as per IS-12824-1989 or latest with up to date ammendments
Mechanical out put in KW :- Suitable for driving submersible pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover.
Class of insulation :- Class ~B~
Max.permissible temp. rise of motor reqd. if different from that given in B (viii) above :- To be specified by the tenderer
Particulars of test reqd. & where they are to be conducted :- As per terms & conditions attached
Particulars as to whether voltage limiting device will be employed :- ATS/Star Delta starter , oil immersed,fully automatic to be insta -lled between bus bar & motor. Shunt capa -citor is also propos -ed to be installed for improving the power factor at site.
(NOTE:- Star delta starter upto 37.5 KW & ATS for 37.5 KW & above)
Type of motor :- As per BIS 9283-1979 or latest with upto date ammendments
Details of shaft extension reqd :- To work with the pump offered
Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit :- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.
Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period :- To work the pump offered
Where possible fault capacity of the system to which the motor is connected :- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations
PUMPS :- BIS 1520-1980 read with BIS 9137-1978
Nos of pumps reqd. :- 1Nos pump.
Spare parts required :- For two years normal maintenance as recommended by manufacturer.
Type of drive :- Electric induction motor
Optional fittings reqd. :- Air cook for exhausting air from each stage
PUMP OPERATING CONDITIONS :-
Capacity of each pump (in lps) :- 15.82 LPS
Total head (in Mts.) :- 20mtrs
If total head is not known then following details be provided :-
i) Static head (in mtrs) :- 9mtrs.
ii) Minimum depth of water (in mtrs) :-
iii) Seasonal Variation in water level (in mtrs) :-
iv) Ground level to max. water level (in mtrs) :-
v) Ground level to delivery point (in mtrs) :-
vi) Pressure in the suction tank (in kg/cm^2) :-
vii) Pressure in the delivery tank (in kg/cm^2) :-
Length of R/Main (in mtrs) :- 60mtr
Dia of R/Main (in mm) :- 150 mm.
Length of Column pipe (in mtrs) :-
Dia of Column pipe (in mtrs) :- 150mm
Turbidity of water (in ppm) :- clear water
Drive type :- Electric driven
Limits of total head in which the pump is reqd. to operate :- (-) 15% to (+) 10% of total head.
Suction/delivery size of pump :- To be specified by the tenderer
Efficiency of pump at :- To be specified by the tenderer
a) duty head
b) (+) 10 % head
c) (-) 15 % head
Material of construction :- To be specified by the tenderer (manufacturers certficate to be appended)
Providing and fixing of Auto control panel with push button star delta starter for submersible pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring , comprising of main switch of suitable Amp. T.P. Volt meter, ammeter,hour run meter, phase indicating lamps with GSM based , Remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day,Inbuilt protection against overload/undervoltage,Dry run,single phase preventor,Inbuilt GPS tracker,phase reversal configurable volt/current limits with a facility to access the system through minimum 10 Nos. authenticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts,installation and testing at site with entire satisfaction of Engineer-in-charge. ( all meters to be installed shall be digital ).
Supply of Kirloskar /Kilburn /IVC /Fouress /Gled /BHEL/ Leader /Kartar make of suitable size cast iron / steel double flanged sluice valve having size one size larger than the nominal dia of delivery of the pump or equal to dia of column pipe (in case of t/well) and capable of withstanding nominal seat pressure as mentioned in item No.1a-(+) surge pressure and conforming to BIS standards with up to date ammendments for delivery line of pump Class of valve 150mm Dia. PN-1.6
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader /Kartar/ KSB make of suitable size cast iron double flanged swing check type reflux valve having bye pass arrangement & size one size larger than the nominal dia of delivery of the pump or equal to dia of column pipe (in case of t/well) and capable of withstanding nominal seat pressure as mentioned in item No.1(a) + surge pressure and conforming to BIS standards with up to date ammendments for delivery line of pump .150mm Dia of valve. PN 1.60.
P/L & fixing of suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/ Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc.conforming to BIS 3624-1987 or latest with up to date ammendments.
Errection of all equipments including cost of tees bends tapers and any other fittings required as per site conditions and as per direction of the Engineer Incharge.
At Main Stage
Supply, erection, testing & commissioning of submersible pumping set of reputed make KSB /BS/Johnston/ Worthington / Sabar/ Oswal conforming to latest relevent BIS code. The pump should be fitted with free flow impellers of bronze /suitable alloy as per BIS 5659 or latest with up to date ammendments suitable for raw/clear water having greased packed bearings & shell with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti / Crompton make conforming to relevent BIS code with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber chamber & grease packed lubricated bearings & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor . The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. & suitable for operation on data given below:-
Total Head in mtrs (i/c depth of Column Pipe in case of T/well) :- 120 mtrs
Capacity (in LPS) :- 31.63 LPS
Dia of R/Main (in mm) :- 150 mm.(existing)
Length of R/main :- 465 mtrs
SITE CONDITIONS :-
Location of Site :- To be filled by Engineer Incharge
The altitude of place in which the motor is intended to work :- 500 mtrs
Humidity :- Wheather generally remains humid during monsoon season
Nature of atmosphere :- As normally encountered in Shivalik Ranges
Detail of quality of water :- Clear water
Water free from sand or not :- Free from sand.
Water corosive or not :-
Turbidity :- Clear water.
Type of well :-
Inside Dia of Well :- ----
Depth of water during HFL in the pond :- To be filled by Engineer Incharge
Max. draw down :- ------
Depth of well :- ------
Any other information or requirement :- ------
OPERATING CONDITIONS :-
Type of current :- AC three / single phase
Operating frequency :- 50 HZ
Rated voltage :- 400 (+/-) 10% volts
System of earthing if any to to be adopted :- Double loop earthing as per BIS 3043-1987 latest with upto date ammendments
Speed of revolution :- To be quoted by Tenderer
Direction of rotation :- To be quoted by Tenderer
No. of working hours per day :- 4hours
The max. Temp. of cooling air & water in the place in which the pumpset is intented to work in ordinary service :- 35 Degree Centigrade
MOTOR :-
Ref to BIS code :- BIS 9283-1979 or latest with upto date ammendments
Type of enclosure of motor :- As per BIS 4691-1985 or latest with up to date ammendments
Type of duty :- S1 i.e. Continuous duty type as per IS-12824-1989 or latest with up to date ammendments
Mechanical out put in KW :- Suitable for driving submersible pumps required for duties specified against pumps. To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover.
Class of insulation :- Class ~B~
Max. permissible temp. rise of motor reqd. if different from that given in B (viii) above :- To be specified by the tenderer
Particulars of test reqd. & where they are to be conducted :- As per terms & conditions attached
Particulars as to whether voltage limiting device will be employed :- ATS/Star Delta starter , oil immersed,fully automatic to be installed between bus bar & motor. Shunt capacitor is also proposed to be installed for improving the power factor at site.
(NOTE:- Star delta starter upto 37.5 KW & ATS for 37.5 KW & above)
Type of motor :- As per BIS 9283-1979 or latest with upto date ammendments
Details of shaft extension reqd :- To work with the pump offered
Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit :- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.
Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period :- To work the pump offered
Where possible fault capacity of the system to which the motor is connected :- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations
PUMPS :- BIS 1520-1980 read with BIS 9137-1978
Nos of pumps reqd. :- 1Nos pump.
Spare parts required :- For two years normal maintenance as recommended by manufacturer.
Type of drive :- Electric induction motor
Optional fittings reqd. :- Air cook for exhausting air from each stage
PUMP OPERATING CONDITIONS :-
Capacity of each pump (in lps) :- 31.63 LPS
Total head (in Mts.) :- 120 mtrs
If total head is not known then following details be provided :-
i) Static head (in mtrs) :- 98 mtrs.
ii) Minimum depth of water (in mtrs) :-
iii) Seasonal Variation in water level (in mtrs) :-
iv) Ground level to max. water level (in mtrs) :-
v) Ground level to delivery point (in mtrs) :-
vi) Pressure in the suction tank (in kg/cm^2) :-
vii) Pressure in the delivery tank (in kg/cm^2) :-
Length of R/Main (in mtrs) :- 465mtr
Dia of R/Main (in mm) :- 150 mm.
Length of Column pipe (in mtrs) :-
Dia of Column pipe (in mtrs) :-
Turbidity of water (in ppm) :- clear water
Drive type :- Electric driven
Limits of total head in which the pump is reqd. to operate :- (-) 15% to (+) 10% of total head.
Suction/delivery size of pump :- To be specified by the tenderer
Efficiency of pump at :- To be specified by the tenderer
a) duty head
b) (+) 10 % head
c) (-) 15 % head
Material of construction :- To be specified by the tenderer (manufacturers certficate to be appended)
Providing and fixing of Auto control panel with push button star delta starter for submersible pumps of L&T and reputed make fabricated with M.S sheet and Angle stand duly painted and complete with internal wiring , comprising of main switch of suitable Amp. T.P. Volt meter, ammeter,hour run meter, phase indicating lamps with GSM based , Remote start/stop operation call/SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day,Inbuilt protection against overload/undervoltage,Dry run,single phase preventor,Inbuilt GPS tracker,phase reversal configurable volt/current limits with a facility to access the system through minimum 10 Nos. authenticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts,installation and testing at site with entire satisfaction of Engineer-in-charge. ( all meters to be installed shall be digital ).
Supply of Kirloskar /Kilburn /IVC /Fouress /Gled /BHEL/ Leader /Kartar make of suitable size cast iron / steel double flanged sluice valve having size one size larger than the nominal dia of delivery of the pump or equal to dia of column pipe (in case of t/well) and capable of withstanding nominal seat pressure as mentioned in item No.4a (+) surge pressure and conforming to BIS standards with up to date ammendments for delivery line of pump Class of valve 150mm Dia. ASA 150
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader /Kartar/ KSB make of suitable size cast iron double flanged swing check type reflux valve having bye pass arrangement & size one size larger than the nominal dia of delivery of the pump or equal to dia of column pipe (in case of t/well) and capable of withstanding nominal seat pressure as mentioned in item No.4(a) + surge pressure and conforming to BIS standards with up to date ammendments for delivery line of pump .150mm Dia of valve shall be ASA 150
P/L & fixing of suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L PVC jointless flat water proof cable as per BIS 694-1990 (latest with up to date ammendments) suitable for the pump sets offered from circuite breaker to motor & motor to starter including all other electrical equipments such as thimbles, flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/ Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc.conforming to BIS 3624-1987 or latest with up to date ammendments.
Errection of all equipments including cost of tees bends tapers and any other fittings required as per site conditions and as per direction of the Engineer Incharge.
vats associates
ROYAL ENGINEERING WORKS
Anand Bhushan
BHAW SINGH KAPOOR CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .