Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹15.7 L+₹11.3 L (253.2%)Admitted-Fee/PreQual/Technical/Finance 19 421 VRINDAVAN BUILDING OPP GOVT ITI HMT ROAD KALAMASSERY ERNAKULAM KERALA 683104 | ERNAKULAM | KERALA | 683104 | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | Powertech Equipments and Services L2 | Excel Electrical Equipment LLP L1 |
|---|---|---|---|---|---|
| 1.00OVERHAULING OF 11000/3300/440V, POWER TRANSORMERS IN TOWNSHIP AND THERMAL PLANT AT FACT CD | |||||
| 1.01 | Leak rectification of 500KVA 11000/440V Transformer in Thermal plant. The scope of work includes dismantling of HT and LT cables and busbars draining oil from the main tank, dismantiling and lifting up the top cover, dismantling LT & HT bushings, replacing the all gaskets of transformer with new one, servicing the buchhols relay, replacing of explosion vent diaphram, supply and installation of of new oil level guage, replacing silica gel of breather, assembling all the dismantled integrals with suitable new gaskets (RC70C grade), filtration of drained oil and refill the same to transformer with BDV more than 40KV, painting of the transformer and its accessories with epoxy primer and paint, connecting all power & control cables and busbars, conducting routine test and commissioning. | 6 | NO | 8,97,120 ₹8,97,120 | 2,76,000 ₹2,76,000 Lowest |
| 1.02 | Leak rectification of 1000KVA 11000/440V Transformer in Thermal plant. The scope of work includes dismantling of HT and LT cables and busbars draining oil from the main tank, dismantiling and lifting up the top cover, dismantling LT & HT bushings, replacing the all gaskets of transformer with new one, servicing the buchhols relay, replacing of explosion vent diaphram, supply and installation of of new oil level guage, replacing silica gel of breather, assembling all the dismantled integrals with suitable new gaskets (RC70C grade), filtration of drained oil and refill the same to transformer with BDV more than 40KV, painting of the transformer and its accessories with epoxy primer and paint, connecting all power & control cables and busbars, conducting routine test and commissioning. | 1 | NO | 1,85,600 ₹1,85,600 | 48,500 ₹48,500 Lowest |
| 1.03 | Leak rectification of 2.75 MVA 11000/3300/440V Transformer in Thermal plant. The scope of work includes dismantling of HT and LT cables and busbars draining oil from the main tank, dismantiling and lifting up the top cover, dismantling LT & HT bushings, replacing the all gaskets of transformer with new one, servicing the buchhols relay, replacing of explosion vent diaphram, supply and installation of of new oil level guage, replacing silica gel of breather, assembling all the dismantled integrals with suitable new gaskets (RC70C grade), filtration of drained oil and refill the same to transformer with BDV more than 40KV, painting of the transformer and its accessories with epoxy primer and paint, connecting all power & control cables and busbars, conducting routine test and commissioning. | 1 | NO | 4,51,750 ₹4,51,750 | 54,700 ₹54,700 Lowest |
| 1.04 | Transformer oil filtering as per IS 1866 | 7,800 | L | 39,000 ₹39,000 Lowest | 66,300 ₹66,300 |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
7 Oct 2026, 4:00 pmClosed
NITHIN C S
SM (P and P)-CD
OVERHAULING OF 11000/3300/440V, POWER TRANSORMERS IN TOWNSHIP AND THERMAL PLANT AT FACT CD.
2026_FACT_927114_1
04026/2026-2027/E34189
Limited
Miscellaneous Works
Item Rate
60 days
Ambalamedu
This tender is issued on limited tender basis from the registered bidders of FACT (CD).
4 documents required · 4 mandatory
₹0
₹5,000
Yes
9 Oct 2026
22 Sept 2026
8 Oct 2026
22 Sept 2026
7 Oct 2026
22 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1OVERHAULING OF 11000/3300/440V, POWER TRANSORMERS IN TOWNSHIP AND THERMAL PLANT AT FACT CD | |||||
| 1.01 | Leak rectification of 500KVA 11000/440V Transformer in Thermal plant. The scope of work includes dismantling of HT and LT cables and busbars draining oil from the main tank, dismantiling and lifting up the top cover, dismantling LT & HT bushings, replacing the all gaskets of transformer with new one, servicing the buchhols relay, replacing of explosion vent diaphram, supply and installation of of new oil level guage, replacing silica gel of breather, assembling all the dismantled integrals with suitable new gaskets (RC70C grade), filtration of drained oil and refill the same to transformer with BDV more than 40KV, painting of the transformer and its accessories with epoxy primer and paint, connecting all power & control cables and busbars, conducting routine test and commissioning. | 6 | NO | - | - |
| 1.02 | Leak rectification of 1000KVA 11000/440V Transformer in Thermal plant. The scope of work includes dismantling of HT and LT cables and busbars draining oil from the main tank, dismantiling and lifting up the top cover, dismantling LT & HT bushings, replacing the all gaskets of transformer with new one, servicing the buchhols relay, replacing of explosion vent diaphram, supply and installation of of new oil level guage, replacing silica gel of breather, assembling all the dismantled integrals with suitable new gaskets (RC70C grade), filtration of drained oil and refill the same to transformer with BDV more than 40KV, painting of the transformer and its accessories with epoxy primer and paint, connecting all power & control cables and busbars, conducting routine test and commissioning. | 1 | NO | - | - |
| 1.03 | Leak rectification of 2.75 MVA 11000/3300/440V Transformer in Thermal plant. The scope of work includes dismantling of HT and LT cables and busbars draining oil from the main tank, dismantiling and lifting up the top cover, dismantling LT & HT bushings, replacing the all gaskets of transformer with new one, servicing the buchhols relay, replacing of explosion vent diaphram, supply and installation of of new oil level guage, replacing silica gel of breather, assembling all the dismantled integrals with suitable new gaskets (RC70C grade), filtration of drained oil and refill the same to transformer with BDV more than 40KV, painting of the transformer and its accessories with epoxy primer and paint, connecting all power & control cables and busbars, conducting routine test and commissioning. | 1 | NO | - | - |
| 1.04 | Transformer oil filtering as per IS 1866 | 7,800 | L | - | - |
stage.html
html • 0.02 MB
finance_974278.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
ComplianceStatement.pdf
Tender Documents • 0.19 MB
TenderDocuments.pdf
Tender Documents • 1.02 MB
SpecialTermsandConditions.pdf
Tender Documents • 0.26 MB
BOQ_974278.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .