Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL PIN 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹49.8 L+₹13.8 L (38.4%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹68.9 L+₹32.9 L (91.5%)Rejected-AOC 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | L3 | Rejected-AOC Not Lowest | |
| 4 | Rejected-Technical 1159 VILL POST LISARI MEERUT UP 250002 | MEERUT | MEERUT | UTTAR PRADESH | 250002 | - | Rejected-Technical Due to enlisted in two class below | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to enlisted in two class below |
Tender Value
₹64.9 L
EMD Value
₹1.2 L
Closing Date
1 Feb 2024, 6:00 pmClosed
CWE Hills Dehradun
HQ CWE Hills Mall Road Dehradun Cantt 248003
Special repair to Bldg No T194 T194B and T194FG at Mainwaring line Lansdowne
2024_MES_636121_1
87177/LDN/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Lansdowne
Class C cat a(i)
6 documents required · 6 mandatory
₹1,000
Yes
AGE (I) Lansdowne
₹1.2 L
Yes
12 Apr 2024
6 Jan 2024
8 Feb 2024
6 Jan 2024
1 Feb 2024
27 Jan 2024
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified.
S&F Pre-painted galvalume aluminium zinc coating AZ-150 GI based corrugated steel sheet 0.50mm thick of any colour (ISI Marked) having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating AZ-150 GI based plain steel sheet 0.50mm thick (ISI Marked) of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section,in any position, any description complete all as specified and directed.
M & L for 2nd class softwood in timber scantling for wall panelling, ceiling, roof truss,post, purlins, rafters and similar work (Clean sawn Timber framed and fixed type) including necessary coating framed joints with glue, complete all as specified and directed.
S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed. Note : The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
M & L for 2nd class soft wood boarding 20 mm thick planed one side, rebeted or fixed with screw, fixed to timber frame work with nails complete all as specified and directed. .
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc and removing unserviceable material,outside cantt area distance not exceeding 1.5 KM. complete all as specified and directed.
M&L for 12mm thick rendering on fair faces of brick work or concrete surface in cement plaster (1:6) finished the surface even and fair complete all as specified and directed.
M&L for 15mm thick plastering on fair faces of brick wall in two layers, Ist layer 10mm thick CM (1:6), and IInd layer 5mm thick CM (1:4), surface finished even and fair mixed with @ 200ml per bag WPC (liquid type) complete all as specified and directed. Note :- WPC (Liquid type) shall be measured and paid separately as supply only.
Supply only liquid water proofing compound.ISI marked complete all as specified and directed.
M&L for preparation of newly plastered surface of external wall all as prescribed by manufacture of paint and applying two coats of exterior anti fungal acrylic emulsion paint (walmista of Berger paint or equitant in Asian paint, Nerolac etc having three years of performance warranty) over a coat of exterior water based primer of same make all as specified and prescribed by manufacture of paint and as directed at site by Engineer-in-Charge.
Note:- (i) The newly plastered surface must be prepared in a manner so that there should not be any impression of dent and it should be made even all as per manufacture instruction before application of emulsion paint. The cost of all materials, T&P and labour required for preparation of surface are deemed to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) after carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v) The colour / shade will be all as approved by GE / AGE (I). (vi) The cost of Scaffolding wherever required are deemed to be included in the rates quoted by the contractor.
M&L for preparation of newly plastered surface of interior wall by application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper over a coat of primer using roller all as specified and prescribed by manufacturer of paint/ distemper and as directed at site by Engineer-in-Charge.
Note:- (i) The new surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper The cost of all material T&P and labour required for preparation of surface are deemed to be included in the rates quoted . (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v) The colour / shade will be all as approved by GE / AGE (I)
M&L for preparation of old decorated surface of interior wall by complete removal of existing treatment with mechanical sander (rpm 1500-2700) along with internal dust extraction system for clean environment certified by reputed paint manufacturers and application of wall care putty to remove the dent and to make the surface even and smooth by grinding or rubbing with sand paper and applying two coats of acrylic distemper using roller all as specified and prescribed by manufacturer of paint and all as directed at site by Engr-in-Charge .
Note: (i) The old surface must be prepared in a manner so that there should not be any impression of dent and it should be made even and smooth all as per manufacture’s instruction before application of distemper. The cost of materials, labour & T&P required for preparation of surface are deemed to be included in the rates quoted. (ii) The work must be got executed through authorised applicator of manufacture after concluding an MoU with manufacture for company back guarantee by the contractor. The authorised applicator of manufacturer shall be got approved from GE/ AGE (I) before commencement of work. (iii) All the material to be incorporated in the work shall be brought by contractor to MES store yard which will be subsequently issued by deportment for incorporation in the work to ensure the quantity to be consumed all as per recommendation of manufacture. (iv) After carrying out preparation of surface the same shall be got approved from GE /AGE (I) before application of distemper for each building. (v) The colour / shade will be all as approved by GE / AGE (I).
M&L for preparation of newly plastered surfaces on wall and apply 1mm thick of Birla/ JK wall care putty for smooth finish of wall complete all as specified and directed.
M & L for Preparation of old wooden surfaces of any description over 10 cm width or girth & applying two coats of synthetic enamel paint Ist quality after removal of existing treatment from old surface with help of thiner or other removing chemical materilas complete all as specified and directed.
M & L for 300x300x 7 to 8mm thick:- Non-Skid light coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.06 Sqm and not exc. 0.11 Sqm, in floor etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 15 mm thick screed bed in cm 1:6 including dismantling of existing old tile. complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I)
M & L for 300X450X 8 to 9 mm thick joint free light coloured glazed ceramic tiles of any design and pattern, as in dado etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622:2017, Group B III with average water absorption between 10% to 15%. Length, width and straightness of sides + 0.20% (Max deviation). Thickness + 4.0% (Max deviation). Straightness of sides and Rectangularity +0.15% (Max Deviation). surface flatness + 0.22% (Max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 10 mm thick in cm (1:4) backing coat and including dismantling of old tiling and removing old unserviceable materials from the distance not exceeding 1.5 Km complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I) Lansdowne
M & L for 400x400x 7 to 8mm thick Joint free Non-Skid light coloured ceramic tiles of any design and pattern, 7 to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.06 Sqm and not exc. 0.11 Sqm, in floor etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 15 mm thick screed bed in cm 1:6 including dismantling of existing old tile. complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I)
M & L for Joint free Virified Ceramic tiles light coloured of any design and pattern, 10 mm thick (Square/rectangular) area of each tiles not exceeding 0.36 Sqm, in floor etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles. Tiles shall be confirming to IS-15622.2006, Group B II with average water absorption between 3% to 6%. Length, width and straightness of sides + 0.10% (Max deviation). Thickness + 5.0% (Max deviation). Centre & Edge curvature and warpage + 0.50% (Max deviation). Breaking strength 1000 N (Minimum) and minimum 95% tiles shall be free from visible defects. including 15 mm thick screed bed in cm 1:6 including dismantling of existing old tile. complete all as specified and directed. Note:- Shade of the tiles including Colour, design and pattern shall be approved by AGE(I)
M & L for pre- polished granite slab machine cut of size 15 to 20 mm thick including necessary notching, chamfering the edges over cement screed bed including Cutting, Grinding and Mirror polishing(Granite finish) with suitable grinding stones complete including 20mm thick in CM 1:6 including dismantling of existing old tile. complete all as specified and directed. Note:- Shade of the granite including Colour, design and pattern shall be approved by AGE (I)
Dismantling of wall and ceiling board (fibre,insulation etc) or insulation board ,slabs blankets, any thickness incl cover fillets complete all as specified and directed.
M&L for providing false ceiling fully perforated 12 mm thick micro tegular edged GRG false ceiling tiles at all heights with GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanized iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
Taking down Chowkats with shutter exceeding 1.5 Sqm . but n . exc 4.00 Sqm each (Without taking off shutters from the frames) all as directed.
Taking down chowkats with shutter n. exc 1.5 sqm each. (without taking of shutter from the frame) all as directed..
S&F 30mm thick molded WPC factory made 1005 decorative type, moulded, solid door shutter (confirming as per IS: 4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600kg/cum manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, termite proof, fire retardent and having screw holding capacity all as specified and directed..
S&F 30mm thick molded WPC wire mesh factory made 1005 decorative type, moulded, solid door shutter, panel door shutter prepare to receive glass, gauze etc (single or two panel Including wire mesh(confirming as per IS: 4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10mm deep mould on single side with wood grain texture and back side plain with density not less than 600kg/cum manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, termite proof, fire retardent and having screw holding capaciity.all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows and other frames/ chowkhat of following size comprising of virgin PVC polymer having K-value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and direction.
Note: (i) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable and variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. (ii) M.S. hold fast/ lugs or SS dash fasteners shall be measured and paid for separately.
65mm x100mm size
65mm x 125mm size
S & F Butt hinges, 100 mm long stainless steel non magnetic ( ISI marked ) complete all as specified and directed..
S&F 300mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and directed.
S&F 200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and directed.
S & F Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified and directed.
S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.
S & F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed with stanless steel wire staple complete all as specified and directed.
S & F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sq.m. each pane including hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in Stone concrete block or slab walls.
M&L for providing and fixing windows & ventilators fabricated from Rolled Formed GI Section made of Galvanised steel colour coated(PPGI Sheets) (Base steel as per IS 513 ‘’D’’ quality. Galvanised as per IS 277 with Zinc of 90 Gsm/SqMt w. PAINT: Pre-Painted sections should be with primer coat of epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.GI Section of 0.58mm thick in Double rebate windows in which both glazed shutter and flymesh shutter, 74 X 60mm outer frame , Mullion 72 x 49mm, Glazed shutter 48 x 22mm, Flymesh 41 x 22mm, Beading with round ends for Glass Fixing 12 x 12mm in fixed portion and the outer frame and mullions to have rebate for glazed/gauzed shutters the sections cut to length metre joined with corner PolyVinylChloride brackets centre mullion fixed with PolyVinylChloride Mullion caps . Glass of 4mm thick plain float glass fitted with Ethylene Propylene Diamine Monomer in glazed shutter and wiremesh of Stainless steel of 36 guage to fix mesh in mesh shutter using VC Black Gypsum Drywall screws and Spoon profile of 0.58mm GI Sheet. Corners of the windows should be joined with corner brackets made of polyvinylchloride with crca of zinc phosphate coat.Each glazed shutter and fly mesh shutter shall be provided with SS Pivot Hinges 2 in each, PolyVinylChloride handle 1 in each and Powder coated Peg stay in Glass shutter.Window shall be provided with Powder coated MS Grill/Guard Bars made of 10mm MS Sq Bar welded to 6 x 12mm MS Flat with countersunk holes at both vertical ends . Gap between the bars should not be more than 150mm . Window frames shall be fixed to brick / concrete masonry by using nylon self expension caps & 75/100 mm MS screws after drilling in walls. VC Black Gypsum Drywall screws should be used while fixng corner brackets,stay,hinges,mullion caps of windows.
Taking up or down steel tubing with connections for cleaning for refixing or removing to storeyard complete of bore 15mm.complete all as specified and directed.
All as per item No 45 here-in-before but 20mm. Bore complete all as specified and directed.
S& F for GI tubing 15mm bore, medium grade ISI marked with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions, including short lengths etc.) ( heavy grade ISI Marked) , fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and directed.
S& F for GI tubing 20mm bore, medium grade ISI marked with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions, including short lengths etc.) ( heavy grade ISI Marked) , fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and directed.
S&F in repair vireous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including PVC cover Make : Cera/Parryware complete all as specified and directed.
S & F CI Nahani trap 75 mm dia with grating (ISI Marked only) including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) complete all as specified and directed
S&F in repairs PVC low level flushing cistern (ISI Marked only), valveless, syphonic action dwell type, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 60/90 cm long etc, supplied and fixed, complete all as specified.
S&F Vitreous china wash hand basin ,white ,flat back of size 550x400mm (ISI Marked only) with PVC connection 15mmdia 450 mm long with PTMT (ISI Marked only) nuts and PVC washer and including cutting for pinning in ends,pair of cast iron brackets and provision of PVC waste pipe 32mm of adequate length , waste coupling 32 mm dia of PTMT half or full threaded Min wt 45 gram,complete all as specified and directed by Engr-in-charge.
S&F in repair bib tap cast copper alloy with crutch or butter fly handle, screwed down for iron pipe 15 mm bore of tubing fancy type chromium plated (ISI Marked). complete all as specified and directed.
S&F in repair stop valve cast copper alloy screwed down high presure screwed both end for iron pipe 15 mm dia fancy type chromium plated (ISI Marked). complete all as specified and directed.
S&F in repair Pillar taps, Fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with long screwed shanks and fly-nuts, screwed for iron pipe screwed down for 15 mm dia bore GI pipe complete all as specified and directed
S & F in repairs 110 mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints fixed to walls complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) pipes single socketed , in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S & F in repairs 75mm bore PVC ( SWR ) pipes ,single socketed in any length with rubber ring joints laid in trenches or in floors.complete all as specified and directed.
S&F PVC (SWR ) bend of 75 mm bore ( ISI Marked) pipe of any radius.complete all as specified and directed.
S&F PVC (SWR) bends with access door any, radius 110 mm bore.complete all as specified and directed.
S&F PVC (SWR) branch piece single (Y) junction equal or unequal, radius 110 mm bore.complete all as specified and directed.
S&F PVC (SWR) junction single (T) equal or unequal, radius 110 mm bore.complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore.complete all as specified and directed.
S & F in repairs grating doom 100mm dia ( ISI Marked) with waste hole of PTMT (Min. Wt. 25 gram ) complete all as specified and directed.
Dismantling of water tanks exc 250 & n. exc 500 Ltr capacity etc and removing to store all as directed.
S&F rotational moulded polyethylene water storage tank of capacity 500 Ltrs, double layer construction, ISI mark (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm dia GI pipe medium grade washout pipe 450 mm long with plug and 20 mm dia GI pipe medium grade overflow pipe 600 mm long with fittings, of following capacity of tank complete all as specified and as directed:-
S&F in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed for 20mm.dia bore of pipe all as specified and as directed:
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level).all as specified and as directed:
Demolition of brick or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dresse stonework and precast concrete articles
M&L for 75 mm thick PCC, 1:4:8,Type D-2 (using 40mm graded stone agg) as in sub base of flooring all as specified and directed
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block 60mm thickness, M-35 Grade with pre-polished, coloured/ laquar finish any shape and size, as approved confirming to IS 15658-2006 including PCC (1:2:4) type B1(using 20mm graded agg) haunching/ benching against sides of path/paver block (kerbs), complete all as specified and directed.
M & L for brickwork with subclass "B" bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6) all as specified and directed
M & L for walling of random rubble stone masonry, un-coursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6 complete all as specified and directed.
M & L for walling of random rubble stone masonry but except stones un-coursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6 complete all as specified and directed.
Extra over stone walling for hammer dressing to faces of stone and dressing of faced beds and joints as specified for RR walling uncoursed or brought upto courses hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc. 40mm for lime or sand stone complete all as specified and directed.
M&L for raised pointing to RR or Polygon rubble uncoursed or brought upto course in cement mortar 1:4 complete all as specified and directed.
M & L for plain cement concrete Type B-1(1:2:4) (using 20 mm graded stone aggregate), cills, steps, parapets , copings,bond stone, bed plates, hold fast and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6), type C-2 using 40mm graded stone aggregate as in plinth protection, surface finished even & smooth without using extra cement, with and including joint filling (Size 30mm deep x 10mm wide) with sealing compound grade-A at 3m interwal and corner complete all as specified and directed.
Dismantling post or strut embeded in concrete( wood/steel/RCC) any section embeded in concrete including taking out embeded portion and making good all as directed & specified
Dismantling fencing wire mesh of any description complete all as specified and directed
M&L for cement concrete 1:4:8, type D2, ,(using 40mm graded aggregate) as in foundations, filling, post hole filling, mass concrete and similar work complete all as specified and directed.
S&F MS as in Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
S&F chain link mild steel galvanised wire fencing of mesh size 100mm x100mm and dia of wire 3mm including 5mm dia GI line wires at top and bottom fixed to any type of standards rails, straining bolts etc including provision of binding wire complete all as specified and directed.
Fixing only chain link fencing including line wires any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed
S&F round Bar 10 mm and over cut to length, bend to shape required including cranking, bending spirally for hoopings for cols, hooking ends and binding with ad including mild steel wire (annealed) not less than 0.9 mm dia. Fe 410 (Gde E-250) Quality -A or Fe-290 (Gde E-165)
E/M PORTION Taking down carefully copper/aluminum point wiring (light/fan/socket power) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.
Taking down carefully copper/aluminum sub main wiring complete, including fixture such as conduit etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.
Taking down carefully TPN DB/ MCB DB complete, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors, etc. all as specified and directed.
M&L for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continuous earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including concealed rigid PVC conduit''medium grade'' (ISI marked) , not less than 20 mm dia duly condealed on wall/ceiling or above false ceiling with fittings medium grade (Color conding of wires shall be Phase, neutral and earth wire all as specified) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets, fan regulators etc including white cover plate complete all as specified and directed. Note: (i) Cost of cutting chases of suitable girth where required on brick/ concrete surface and making good disturbed surface shall deemed to be included in quoted rates. (ii) If the contractor fail to make good the disturbed surface of wall/ ceiling etc and do not match with the existing surface of wall/ ceiling to the entire satisfaction of Engr-in-Charge a recovey @ of Rs. 50/- per RM willl be made from payment due to the contractor. In case of any dispute the decision of accepting officer will be final and binding.
One light/fan/bell point controlled by one No modular type switch 6 Amps single pole one way
One 3 pin 6 Amps socket outlet on same board controlled by one, one way 6 Amps modular switch.
One socket outlet 5/3 pin 6 Amps controlled by one modular switch on independent board.
All as per item No 91 here-in-above but wiring with 2.5 sqmm single core multi stranded copper condcutor 1100 V grade PVC insulated FRLSH but unsheathed single core for 16 Amps power point on independent board and 2.5 sqmm FRLSH cable as earthwire.
S & F switch Modular single pole, one way 6 Amps , 1 module,ISI Marked 230 volts, 50 hz complete all as specified and directed.
S & F bell push Modular single pole, one way 6 Amps , 1 module, ISI marked, 230 volts, 50 hz complete all as specified and directed.
S&F Modular switch 1 way 16 Amps, 1 module,ISI Marked 230 volts, 50 Hz complete all as specified and directed.
S&F Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed.
S&F Modular Socket outlet, 16A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed.
S&F bell ding dong elelctric 230V AC single pole complete all as specified and directed
S & F fancy lamp holder, insulated body with back plate for batten fitting complete all as specified & directed
S&F ceiling rose 3 terminal / PVC/ polycarbonate, isolated body complete all as specified and directed
S&F MCB DB SPN 12way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed.
S&F MCB DB SPN 08 way with 200 amps 240 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed.
S&F MCB DB TPN 4 way with 200 amps 415 volts rated copper busbar in sheet steel enclosure.double door type complete all as specified and directed.
S&F MCB , SP, AC, 240 volts of 06 to 32 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
S&F MCB, SPN, AC, 240 volts of 40 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
S&F MCB, TPN, AC, 415 volts of 63 Amps capacity 10KA, 'C' series and making connections with suitable size of copper lugs complete all as specified & directed.
S&F surface mounted LED luminiare 20 watt with all accessories having aluminum extruded channel with diffuser for glare free light,high lumen output,driver PF>0.95 having over voltage protection upto 400 volts surge protection,level 7-10 KV thermal short circuit protection THD<10% made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency>120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose all as directed.
S&F LED Bulb 10 Watt (cool day light) having colour temp 6500 K and lumen output 950 suitable for "B-22 type to fix on batten holder complete all as specified and directed.
S&F 36 Watt, Recess LED Panel 2X2environmental friendly, fully diffused, using engineering grade polycarbonate diffuser, new generation, aesthetically designed, CRCA housing, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/ Grid Ceiling, Voltage range – 120v- 280V AC, System efficacy – 110 Lumen / Watt, power factor >0.95, thd<15%, CCT 6500K, including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ all as specified & directed,
S&F Crown shaped Post top lantern fitting in soothing moon finish made up of polycarbonate, including 20 W retrofit LED lamp with B-22 base complete all as specified and directedx..
S&F LED building security light 1 x 20 W housing made out of pressure die-cast aluminium alloy with toughned glass, IP 66 protection working on 240 volts, 50 Hz, consisting of reflecting lamps wired with appropriate driver PF> 0.95 having over voltage protection upto 440 volt, surge protection level > 10 KV, thermal short circuit protection THD< 10% made up of long life LED chip (SMD) in modular with Ra< 70, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminaire efficiency> 120 luminous /watt power LED should be of more than 01 watt CCT should be between 5700° K- 6500° K including fixed on wall with 1.2 mtr 32 mm GI pipe bracket & 02 Nos MS clamp made out of F1 40 x 6 mm or as directed including connecting with 1.5 sqmm , 3 core, PVC insulated copper conductor cable 1100 Volt grade from ceiling box to light complete all as specified and as directed.
S&F sub main wiring two single core 6 Sqmm PVC insulated, unsheathed, stranded copper conductor cable(FRLSH) 1100Volts grade drawn in & including rigid PVC Conduit 20mm dia or more medium grade concealed in wall along with 6.00 Sqmm PVC insualted unsheathed copper conductor cable (FRLSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed. Note : Two runs of phase, neutral wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
S&F Exhaust fan Steel body AC single phase 230 Volt of size 300 mm sweep complete with blade, Frame and louvers including making hole and grouting of nut bolts etc and making good the disturbed sufaces of wall complete all as specified and directed.
Disconnecting and taking out old unserviceable LT UG XLPE Cable and Supplying & laying, of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked of size 16 sqmm 2 core complete all as specifed and directed.
Disconnecting and taking out old unserviceable LT UG XLPE Cable and Supplyin &, laying of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098 ) ISI marked of size 25 sqmm 4 core complete all as specifed and directed.
Disconnecting and taking out old unserviceable LT UG XLPE Cable and Supplying & laying of 1.1 KV grade XLPE insulated PVC sheathed steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked of size 70 sqmm 3.5 core complete all as specifed and directed.
Disconnecting and taking out old unserviceable LT Panel and Material and labour for design ,supply, fabrication, Installation, testing and commissoning Factory made LT panel at outdoor type totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 Hz AC supply system, fully compartmentalized, both side openable, made out of 3.00 mm thick CRCA sheet, protection of enclousure IP-54 as per IS: 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size(minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed.
(Outgoing) Consist of separate compartment for each MCCB.- (a) MCCB 63 Amp, 415 Volts, 04 Pole 50Hz, 25 KA with adjustable thermal magnetic release in built instantaneous protection, Ics = 100 % Icu(1 sec) - 01 Nos. (b) MCB SPN 40Amp - 03 Nos
Excavation in trenches in soft/disintegrated soil not exc 1.5 m wide and not exceeding 1.5m in depth for laying UG cable/foundation etc complete all as specified and directed.
Returning filling in soft/disintegrated soil including spreading levelling watering and well ramming in layers n.exc 25cm each layer complete all as specified and directed.
Removal of excavated surplus soft/disintegrated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid sepetarely under relevent item of Sch.
S & Laying well burnt bricks, subclass 'B' bricks, laid flat with width equal to length of brick and laid dry over eletric cable for protection of cable complete as directed.
S & F galvanised iron tube with all fittings 'light grade 40mm dia for laid under roads/drain or fixing of poles/wall with flate iron clamps, muts, boltls and washers all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4mm GI Wire check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI Wire upto 7.5 mtrs long with 15 mm dia Medium grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip toDB, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI Wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
RAMAPATI ENGINEERING SERVICES
Anil Kumar Gupta
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .