Loading…
Loading…
Tender Value
₹2.1 L
EMD Value
₹2,100
Closing Date
15 Jun 2026, 6:00 pm6d left
EXECUTIVE ENGINEER,VAPI R DN
Tender for Erection & Maintanance of HT ,LT,TC and other works and supply ,laying, testing & commissioning of 11 KV underground cable ( cable will be supplied by DGVCL) in various Villages ( Pariya -Sukhlav Route) in all scheme under Pardi Rural Sdn Under Vapi Rural Division.
311488
DGVCL/VPR /EXP/O&M/2026-27/3 DT.05.06.2026 SR.NO.16
Open
Miscellaneous Works
Valsad
5 documents required · 4 mandatory · 1 optional
₹1,180
DGVCL , Payable @ VAPI RURAL DIVISION
₹2,100
5 Jun 2026
5 Jun 2026
5 Jun 2026
15 Jun 2026
5 Jun 2026
(A) CAPITAL WORK LABOUR RATES FOR FY 2024-25 (WITHOUT GST)
Sr No. Item Code Description UNIT Rate
9926000001 HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF CROSS ARMS, CLAMPS ANTI-CLIMBING DEVICES, NO.
1 DANGER BOARD, INSULATORS ETC. COMPLETE AND PAINTING OF FABRICATED MATERIALS AND NUMBERING
COMPLETE WITH COST PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
9926000002 ERECTION OF PSC POLES OF 8METER 200 KG INCLUDING EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING NO.
2 OFCROSS ARMS, TOP FITTING CLAMPS ANTICLIMBING DEVICES, INSULATORS ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
9926000003 ERECTION OF STEEL POLES OF 9 TO 11 METERS INCLUDING EXCAVATION OF PIT AND REFILLING OF EARTH, NO.
FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING DEVICES, DANGER BOARD, INSULATORS ETC.
3 COMPLETE AND PAINTING OF STEEL POLE, FABRICATED MATERIALS USED ON THE POLE AND NUMBERING
WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
9926000004 ERECTION OF STEEL POLE OF 13 METERS FOR RAILWAY CROSSING ON BG/MG/NG LINE FOR 0.400/11/22KV NO.
OVERHEAD LINES I.E INCLUDING EXCAVATION OF PIT & REFILLING OF EARTH, FIXING CROSS ARMS, TOP FITTING
4 CLAMPS,ANTICLIMBING DEVICES DANGER BOARD, INSULATORS ETC. COMPLETE AND PAINTING OF STEEL
POLES, FABRICATED MATERIALS USED ON THE POLES ANDNUMBERING WITH COSTOF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
9926000005 ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS & NO.
REFILLING OF EARTHING, FIXING OF CHANNELS, SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING DEVICES
5 DANGERBOARDS,INSULATORS ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SETS AND EARTHING. (WITHOUT AB SWITCH)
9926000006 ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO 11 METERS.STEEL POLE INCLUDING EXCAVATION OF PITS NO.
&REFILLING OF EARTH, FIXING OF CHANNELS, SUPPORTING ANGLES,CLAMPS,ANTI-CLIMBING DEVICES DANGER
6 BOARDS, INSULATORS ETC.COMPLETE &PAINTING POLES,FABRICATED MATERIAL SUSED ON THE POLES AND
NUMBERING WITH COST OF PAINTSAS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY
SET ANDEARTHING. (WITHOUT AB SWITCH)
9926000007 ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH, HGFUSES OF 8 MTRS 200 KG PSC NO.
POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH,FIXING OF CHANNELS SUPPORTING ANGLES,
7 CLAMPS,ANTI-CLIMBING DEVICES, DANGER BOARDS, INSULATORS,DO FUSES ETC. COMPLETE AND PAINTING
OF FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT EXCLUDING OF ERECTION OF GUY SET AND EARTHING. (WITH
9926000008 ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH,HG FUSES, 9 TO 11 METERS STEEL NO.
POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH, FIXING OF CHANNEL, SUPPORTING ANGLES,
8 CLAMPS, ANTICLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC. COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE POLES ANDNUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUTEXCLUDING ERECTION OF GUY SET AND EARTHING. (WITH AB SWITCH)
9926000009 ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OFAB SWITCH,FUSES, TRANSFORMERS, NO.
LIGHTENING ARRESTORS, DISTRIBUTION BOX. OF 8 METERS 200 KG PSC POLES INCLUDING EXCAVATION OF
PITS AND REFILLING OF EARTH, CARTING OF TRANSFORMERS FROM STORES TO SITE, FIXING OF
9 CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING DEVICES DANGER
BOARDS,CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
9926000010 ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH,HG FUSES TRANSFORMERS, NO.
LIGHTENING ARRESTORS, DISTRIBUTION BOX 9 TO 11 METERS STEEL POLES INCLUDINGEXCAVATION OF
PITS & REFILLING OF EARTH CARTING OF TRANSFORMERS FROM STORE TO SITE, FIXINGOF CHANNELS
10 SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTICLIMBING DEVICES, DANGER
BOARDS,CONDUCTOR AND CABLE WIRING ETC. COMPLETE AND PAINTING OF POLES FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTIONS OF GUY
SETS AND EARTHING.
9926000011 ERECTION OF GUY SET INCLUDING EXCAVATION OF PITS & REFILLING OF EARTH AS PER STANDARD NO.
SPECIFICATION WITH STAY CLAMPS, STAY WIRE, ANCHOR ROD, TURN BUCKLE, EYEBOLT, GUY INSULATOR,
11 CEMENT CONCRETE BLOCK ETC. BUT EXCLUDING CONCRETING.
9926000012 CONCRETING OF POLES, GUYS, ETC. INCLUDING COST OF CEMENT SAND METAL (1:2:4)AND WATER ETC. AS PER CMT
12 STANDARD SPECIFICATION.
9926000013 ERECTION OF COIL TYPE EARTHING INCLUDING COST OF COAL,SALT ETC. BUT WITHOUT COST OF Gl WIRE AS NO.
13 PER STANDARD SPECIFICATION(20kg salt+20kg coal)
9926000014 ERECTION OF Gl PIPE/CI PLATE TYPE EARTHING INCLUDINGCOST OF COAL SALT ETC. BUT WITHOUT COST NO.
14 OF PIPE/GIPLATE Gl WIRE AS PER STANDARDSPECIFICATION. (20k solt+20k coal)
9926000015 ERECTION OF STREET LIGHT FIXTURE COMPLETE WITH CLAMPS, BRASS NIPPLE, BRASS HOLDER TECK NO.
15 WOODBUSH,REFLECTORS FUSE, WIRING ETC. AS PER STANDARD SPECIFICATION BUT EXCLUDING COST OF
9926000016 STRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING ONECONDPER
16 FIXING OF INSULATORS BINDING JUMPERING ETC. KM
17 9926000017 STRINGING OF Gl WIRE 8 SWG INCLUDING BINDING JUMPERING ETC. DO
9926000018 PROVIDING SINGLE PHASE SERVICE CONNECTION WITH- PVC 4MM TWIN CORECABLE FROM TERMINAL POLE NO.
18 TOMETERING POINT INCLUDING FIXING OFMETER WITH METER EARTHING COMPLETE WORK AS PER
STANDARD SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
9926000019 PROVIDING THREE PHASE 4 WIRE SERVICE CONNECTION WITH PVC 4MM2/10MM2 FOUR CORE CABLE FROM NO.
TERMINAL POLE TO METERING POINT INCLUDING FIXING OF METER WITH METER EARTHING COMPLETE WORK
19 AS PER STANDARD SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
9926000020 ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD ROCK AREA FOR ERECTION OF POLE/ GUY ETC. AS PER NO.
STANDARD SPECIFICATION OVER & ABOVE NORMAL COST COVERED AGAINST EXCAVATION OF PIT UNDER
20 NORMAL SOIL FOR ERECTION OF POLE,GUY, DOUBLE POLE STRUCTURE EARTHING WITH THE APPROVAL OF
SUPDT.ENGINEER.
21 9926000021 PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL CROSSING. MTR
9926000022 PROVIDING GUARDING OF LT LINES ON ROAD/RAIL CROSSING. MTR
9926000023 LT LINE TAPPING- SINGLE PHASE NO.
24 9926000024 LT LINE TAPPING- THREE PHASE NO.
25 9926000025 LAYING OF OVER HEAD LT CABLE FOR ROAD CROSSING,HT LINE CROSSING AND TELEPHONE LINE CROSSING NO.
9926000026 ERECTION OF SINGLE POLE STRUCTURESWITH, HG FUSES,TRANSFORMERS,LIGHTENING ARRESTOR, NO.
DISTRIBUTION BOX. ON 8 METERS 200 KG PSC POLE INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROM STORES TO SITE, FIXING OF CHANNELS, SUPPORTING
ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING DEVICES DANGER BOARDS,CONDUCTOR AND CABLE
26 WIRING ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE POLE AND NUMBERING
WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
9926000027 ERECTION OF SINGLÉ POLE STRUCTURES WITH HG FUSES,TRANSFORMERS,LIGHTENING NO.
ARRESTOR, DISTRIBUTION BOX. ON 9 to 11 METERS RSJ POLE INCLUDING EXCAVATION OF PITS AND REFILLING
OF EARTH, CARTING OF TRANSFORMERS FROM STORES TO SITE, FIXING OF CHANNELS, SUPPORTING
27 ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING DEVICES DANGER BOARDS,CONDUCTOR AND CABLE
WIRING ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE POLE AND NUMBERING
WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OFGUY SETS AND
9926000028 ERECTION OF PSC POLES OF IO METER 270 KG INCLUDING EXCAVATION OF PIT AND REFILLING OF EARTH, NO.
28 FIXING OF CROSS ARMS, TOP FIITING CLAMPS ANTICLIMBING DEVICES, INSULATORS ETC. COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
9926000029 ERECTION OF DOUBLE POLE STRUCTURE OF 10 METER 270 KG PSC POLES INCLUDING EXCAVATION OF PITS & NO.
REFILLING OF EARTHING, FIXING OF CHANNELS, SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING
29 DEVICES DANGERBOARDS,INSULATORS ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS
USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARDSPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS ANDEARTHING. WITHOUT AB SWITCH
9926000030 STRINGING OF IOOMM2 ACSR/100MM2 AAAC CONDUCTOR FOR HT/ LT LINES INCLUDING FIXING OF ONE
30 INSULATORS, BINDING JUMPERING ETC. COND
9926000031 STRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES INCLUDING FIXING OF INSULATORS, BINDING ONE
31 JUMPERING ETC. COND
9926000032 ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OF AB SWITCH,HG FUSES, TRANSFORMERS, NO.
LIGHTENING ARRESTORS, DISTRIBUTION BOX. OF 10 METERS 270 KG PSC POLES INCLUDING EXCAVATION OF
PITS AND REFILLING OF EARTH, CARTING OF TRANSFORMERS FROM STORES TO SITE, FIXING OF CHANNELS,
32 SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTI-CLIMBING DEVICES,DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION
OF GUY SETS AND EARTHING.
33 9926000033 DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING OF FABRICATION AT STORE &STACKING OF POLE SAFELY No.
ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
34 9926000034 DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING OF FABRICATION AT STORE & STACKING OF POLE No.
SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
9926000035 DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) (WITH TRANSFORMER) WITH CREDITING OF No.
35 FABRICATION & TRANSFORMER AT STORE & STACKING OF POLE SAFELY ON ROADSIDE OR CREDITING TO
DEPARTMENTAL STORE
9926000036 DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) (WITHOUT TRANSFORMER) WITH CREDITING OF No.
36 FABRICATION AT STORE & STACKING OFPOLE SAFELY ON ROAD SIDE ORCREDITING TO DEPARTMENTAL STORE
9926000037 STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM INCLUDING FIITING OF ALL ACESSORIES I.E. SPECIAL KM
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF
37 MESSENGER WIRE AND TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY INSULATED PIERCE-
ING CONNECTORS THROUGH SERVICE CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED BY ENGINEER
9926000038 STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM INCLUDING FITTING OF ALL ACESSARIES KM
I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT SHACKLE INSULATOR ETC. FOR
38 FIXING OF MESSENGER WIRE AND TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY INSULATED
PIERCE-ING CONNECTORS THROUGH SERVICE CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED BY
ENGINEER IN CHARGE.
9926000039 STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL KM
39 DESIGNSUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, BINDING TO PIN INSULATOR,PREPARING
SHACKLEPOINT,JUMPERS ETC. AS REQUIRED &DIRECTED BY ENGINEER IN CHARGE
9926000040 STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL KM
40 DESIGNSUSPENSION / TENSION CLAMP, FIXING OFCROSS ARM, BINDING TO PIN INSULATOR,PREPARING
SHACKLEPOINT,JUMPERS ETC. AS REQUIRED AND DIRECTED BY ENGINEER IN CHARGE
9926000041 STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM INCLUDING FITTING OF ALL ACESSORIES I.E. KM
SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS ARM, LT SHACKLE INSULATOR ETC. FOR
41 FIXING OF MESSENGER WIRE AND TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY INSULATED
PIERCE-ING CONNECTORS THROUGH SERVICE CONNECTION BOX COMPLETE AS REQUIRED & DIRECTED BY
ENGINEER IN CHARGE.
42 9926000042 DISMENTALING OF RSJ (9/11 METER) POLE AND CREDITING THE OLD MATERIAL TO STORE Nos
9926000043 DISMENTALING TRANSFORMER CENTER ON IO MTR,270KG PSC POLE WITHOUT TRANSFORMER WITH Nos
43 CREDITING OF FABRICATION AT STORE AND STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
9926000044 DISMENTALING OF TRANSFORMERCENTER ON IOMTR,270KG PSC POLE(WITH TRANSFORMER) WITH Nos
44 CREDITING OF FABRICATION AT STORE AND STACKINGOF POLE SAFELY ON ROAD SIDE ORCREDITING TO
DEPARTMENTAL STORE
45 9926000045 DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM AND CREDITING FITTINGOF ALL ACESSARIES AND KM
FABRICATION TO DEPARTMENTAL STORE
46 9926000046 DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM AND CREDITING FITTINGOF ALL ACESSARIES AND KM
FABRICATION TO DEPARTMENTAL STORE
47 9926000047 DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM AND CREDITING FITTING OF ALL ACESSARIES TO KM
DEPARTMENTAL STORE.
48 9926000048 DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM AND CREDITING FITTING OF ALL KM
ACESSARIES TO DEPARTMENTAL STORE.
49 9926000049 DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 1*35 SQ MM AND CREDITING FITTING OF ALL KM
ACESSARIES TO DEPARTMENTAL STORE.
9926000050 RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING ONE
50 FIXING OF INSULATORS, BINDING JUMPERING ETC. COND
9926000051 RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES INCLUDING , BINDING JUMPERING ETC. ONE
52 9926000052 LABOUR CHARGE FOR THE INSTALLATION OF NEW DTR METER. (METER WILL BE PROVIDED BY DGVCL NO.
53 9926000053 LABOUR CHARGE FOR THE REPLACEMENT OF DTR METER AND OLD METER SHOULD BE CREDITED TO SDN NO.
STORE. (METERWILL BE PROVIDED BY DGVCL
54 9926000054 LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR METER CONNECTION. (CT COILWILL BE PROVIDED BY PER
55 9926000055 LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR DTR METER CONNECTION AND OLD CT SHOULD BE PER
CREDITED TO SDN STORE. (CT COIL WILL BE PROVIDED BY DGVCL CT
56 9926000056 LABOUR CHARGE FOR FIXING OF MMB FORDTR METER (MMB WILL BE PROVIDED BY DGVCL NO.
57 9926000057 LABOUR CHARGE FOR REPLACEMENT OF DTR METER BOX. (METER WILL BEPROVIDED BY NO.
58 9926000058 PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE COPPER CABLE 3.5 METER (CABLETO BE PROVIDED BY NO.
9926000059 LABOUR CHARGE FORPROVIDING/RECONNECTION OF TERMINALCONNECTION WITH PROPER PER
SIZE OF LUGS. LUGS COST IS BORNE BY AGENCY TERMIN
9926000060 LABOUR CHARGE FOR THE SPOT READINGOF DTR METER WITH DETAIL SURVEY OF DEFECT IF ANY. A DULY SIGN PER
60 COPY BY SURVEYOR PERSON OF AGENCY IN PROFORMA REPORT SHOULD BE SUBMITTEDTO SDN ONLY IF DTR
ALLPARAMETER OF VOLTAGE, CURRENT & LOAD AS SHOWN IN PER-FORMA IS FILLED) AS PER THE
INSTRUCTION OF ENGINEER IN-CHARGE.
9926000061 LABOUR CHARGE FOR THE SPOT READINGOF DTR METER WITH DETAIL SURVEY OF DEFECT IF ANY. A DULY SIGN PER
61 COPY BY SURVEYOR PERSON OF AGENCY IN PROFORMA REPORT SHOULD BE SUBMITTED TO SDN OFFICE. DTR
(DULY FILL PER-FORMA IN FAULT CONDITION IN WHICH READINGPARAMETER IS NOT SHOWN IN METER
9926000062 INSTALLATION OF DTR METER INCLUDING METER BOX, PROVIDING & FIXING OF 1.5SQ MM SINGLE STRAND 10 NO.
62 CORE ARMOURED COPPER CABLE (3.5METER), TERMINATION IN METER & COIL BOX,CT/PT COIL WILLBE
PROVIDED BY DGVCL
63 9926000063 INSTALLATION OF DTR METER INCLUDING METER BOX, TERMINATION IN METER & COIL ETC. (WITHOUT 10 NO.
CORE COPPERCABLE) (METER,METER BOX,CT/PT COILWILL BE PROVIDED BY DGVCL
64 9926000064 Binding of messanger Conductorat with a distance not more than 0.75 mtr with 6 turns minimum on XLPE Cable NO
with single strand binding wire (including cost of binding wire)
65 9926000086 Supply and Installation of 11/22 kV Distribution Transformers HT Terminal protector (UV Resistance) with using PER SET
95/120/150 sq.mm long barrel aluminum lug. (1Set = 3 Nos i.e. on R, Y, B)
9926000087 Supply & Installation of HT EPR Tap on 11/22 kV Distribution Transformer with replacement of bare conductor PER SET
66 by HT ABC conductor (DO bottom side to transformer) after removal of semi conductor by HT ABC (6 inch both
side). HT ABC to be supplied by DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
9926000088 Supply, Installation, Testing and Commissioning of Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic) Type, NO
67 Earth Electrodes for HT Feeder Pole Having 2000 mm Electrode Length as per the Tender Specifications and
Drawing. (All Materials Will Be Supplied By Agency)
9926000089 Supply, Installation, Testing and Commissioning of Maintenance Free, Ready Capsule, Pipe-In-Cage (Pic) Type, NO
68 Earth Electrodes for HT Feeder Pole Having 3000 mm Electrode Length as per the Tender Specifications And
Drawing. (All Materials Will Be Supplied By Agency)
9926000090 Supply and Installation of 25 X 3 mm GI Strip having hot dip- galvanized-zinc coating of 80-100 microns without Meter
any joints or welding. Both the end of the GI strip should be connected with GI nut bolts and required
69 fabrication work for giving separate earthing connections to(1) Neutral of the transformer(2) MS structures of
the transformer center (Approximately 25 meter GI strip per transformer centre- as per requirement and
instruction of Engineer in- charge) (All Materials will be supplied by Agency)
9926000092 Supply and Installation of uPVC standard make Pipe of 1.25" diameter for covering GI strip with UV protected Meter
70 Cable Ties of 550 X 7.6 mm size to bind with pole face(Approximately 25 meter uPVC pipe for GI strip covering
per transformer centre -as per requirement and instruction of Engineer in-charge.
71 9926000093 Supply & fixing of upto 33 kV Conducotr sleev for Busbar to Drop out Fuse and Drop out fuse to Transformer Meter
H.T. including Busbar (12 mm sleev) as per technical specification. (All Materials will be supplied by Agency)
72 9926000094 Supply & fixing of upto 33 kV Conducotr sleev for Busbar to Drop out Fuse and Drop out fuse to Transformer Meter
H.T. including Busbar(15 mm sleev) as per technical specification. (All Materials will be supplied by Agency)
9926000095 Supply & fixing of Disc type Red Color FRP(Non-flammable) material with Weather resistant, Non-conductive NO
73 bird guard OD=300 MM, ID=33 MM, Width =1.25 MM, one side cut from ID to OD. (All Materials will be
supplied by Agency)
74 9926000096 Providing and fixing of LT Terminal protectors i.e. Re-useable boot (LT Side 1.1 kV) including LT (1.1 kV) NO
insulating taps. All live part at LT side shall be covered with fixing of LT insulating taps.
75 Nylon Net around Transformer Center
75.1 9926000097 Nylon Net (12 * 15 ft) Per Net
9926000098 Nylon Dori Per tc
75.3 9926000099 Labour charge for fitting Nylon Net (All fabricated material for fitting nylon net shall be provided by DGVCL) Per tc
(B)Labour Charges for Maintenance Work
1 9924000001 Cutting of Tree branches surrounding HT/LT line per Tree
2 9924000002 Replacement of old jumpers & providing new double jumpers with 8" binding & capsuling with PVC pipe etc. No
3 9924000005 Support pole for stay PSC/STP/RSJ No.
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
5 9924000007 Pin binding of conductor 11/22kv Pin insulator per pole in coastal area with cleaninGg . No.
6 9924000008 Pin binding of conductor LT shackle insulator No.
7 9924000009 Replacement of one/bothinsulator at strain pole No.
8 9924000010 Replacement of LT shackle insulator at cut point No.
9 9924000011 Re-fixing of V cross Arm No.
10 9924000012 Re placement of V cross Arm No.
11 9924000013 Re-fixing of Top fitting in proper position No.
12 9924000014 Replacement of Top fitting No.
13 9924000015 Replacement of LT cross Arm No.
14 9924000016 Providing DO fuse on DP with carting& jumpering (ONE DO FUSE) No.
15 9924000017 Numberings of pole with paint by preparing back ground of one colour and No.
have lettering(height 3" * width0.5" using stencil
16 9924000018 Fixing of MMB(IPH.) at consumer end No.
17 9924000019 Fixing of MMB(3PH.) at consumer end No.
18 9924000020 Replacement of (Iph.) meter forUrban area No.
19 9924000021 Replacement of (Iph.) meter for Rural area No.
20 9924000022 painting consumer no. on MMB (Urban) (with letter size height40mm* width 8mm No.
21 9924000023 painting consumer no. on MMB (Rural) (with letter size height 40mm* width 8mm No.
22 9924000024 Replacement of deteriorated Single hase Service line No.
23 9924000025 Fixing of new dist. Box with complete wiring includin clamps, nut bolts etc. No.
24 9924000026 Repairing of guarding involving reshaping of bearer wire cross lacing binding etc. R Mtr.
25 9924000027 Painting of steel fabricated material of RSJ DO DP structure with paint No.
26 9924000028 Painting of steel fabricated material of RSJ pole mounted transformer double pole structure with paint No.
27 9924000029 Painting of steel fabricated material of RSJ single pole with paint No.
28 9924000030 painting of steel fabricated material of PSC Single pole (HT line) with paint No.
29 9924000031 painting of steel fabricated material of PSC DO DP double pole with paint No.
30 9924000032 painting of steel fabricated material of PSC double pole at pole mounted transformer with paint No.
31 9924000033 Providing line separator single phase No.
32 9924000034 Providing line separator three phase No.
33 9924000035 Replacement / Providing of stay insulator along with adjustment No.
of tension in stay wire
34 9924000036 Replacement of deteriorated /providing LT dist. Box with new up to 100KVA capacity & crediting it to store. No.
35 9924000037 Replacement of deteriorated /providing LT dist. Box with new above 100KVA capacity & crediting it to store. No.
36 9924000038 Adjustment of tension in stay wire No.
37 9924000039 Refitting of LA No.
38 9924000040 Converting pin point to Shackle point including dismantling & restringing etc. location
39 9924000041 replacement of 11KV Pin insulator with providin new double in binding No.
40 9924000042 replacement of 22KV Pin insulator by new 11 kv pin insulator with spares & providin new double in binding No.
41 9924000043 Providing 11 kv double disc insulators with binding & restringing No.
42 9924000045 Replacement of existing conductor (all size) with new double in binding Cond/KM
43 9924000046 Plumbing of psc Pole with straightening at pin point No.
44 9924000047 Plumbing of psc Pole with straightening at tension point No.
45 9924000048 Plumbing of tilted DP structure (PSC/RSJ/STP) with refilling of stone Murrum etc. No.
46 9924000049 Providing new 11 kv AB [GO switch with fabrication and insulated colour code jumper binding lugs etc. Set
47 9924000051 Replacement of old 11 kv AB /GO switch with providing new insulated jumper, binding, lugs etc. Set
48 9924000052 Providing cage type loop guard in vertical LT line with using PVC reel insulators etc. per pole
49 9924000053 Labour charges for replacement /providing of MMB & service with all No.
accessories for three phase connection
50 9924000054 Labour charges for replacement /providing of MMB & service with all accessories for connection No.
51 9924000055 Dismantling of existing Dist. X'mer center (RSJ/STP POLE) 25/63/100/200 KVA No.
with all fabrication & crediting the old material to store.
52 9924000056 Disconnection from LT pole 1 phase No.
53 9924000057 Reconnection from LT pole 1 phase (payment after receipt of R/C charges) No.
54 9924000058 Disconnection from LT pole 3 phase No.
55 9924000059 Reconnection from LT pole 3 phase (payment after receipt of R/C chagr es No.
56 9924000060 Dismantling & removing of service line from pole & crediting to S/dn (1 phase) No.
57 9924000061 Dismantling & removing of service line from pole & crediting to S/dn (3h phase ) No.
58 9924000062 Reconnection of service line complete with PVC cable(1 ph) No.
59 9924000063 Reconnection of service line complete with PVC cable(3 ph) No.
Providing spiral type earthing by connecting earth terminal with earth terminal of meter box with G.I. SWG no
up to 1.5meters (total weight approximately 2.2kg-20 meter in length) with salt and coal 10kg each, including
60 9924000064 pvc rigid pipe 20mm dia (1.5mtr length) to cover exposed part of G.I. wire , providing and fixing of single core No.
1.5 sq mm single strand copper insulated cable with cable nail clip to be connected with connector to G.I. wire
at consumer end as per drawing DGVCL cons. earth. Earth resistance should be less than 2 ohms(All materials
supplied by contractor .
Providing and fixing of single core 1.5 sq mm single strand copper insulated cable with cable nail clip for spiral
type earthing at consumer end. The end of G.I. no 8 is to be connected by connector with copper cable of which
61 9924000070 other end shall be connected to the earth terminal of meter box. This item shall be used in location where per meter
there is more distance between earth terminal and earthing terminal of meter. All materials supplied by
(C) REPLACEMENT OF BARE CONDUCTOR BY HT / LT AERIAL BUNCH CONDUCTOR
Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT shackle insulator etc. for fixing of messenger wire and
1 9924000065 inclusive of dismantling charge of existing bare conductor and crediting in to store & dismentaling of service KM
line from LT bare conductor and to provide service connection on Aerial Bunch Cable by insulated pierceing
connectors through service connection box complete as required & directed by Engineer in Charge.
Stringing of LT ABC of 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM including fitting of all acessaries i.e. special
design suspension / tension clamp, fixing of cross arm, LT shackle insulator etc. for fixing of messenger wire and
2 9924000066 inclusive of dismantling charge of existing bare conductor and crediting in to store & dismentaling of service KM
line from LT bare conductor and to provide service connection on Aerial Bunch Cable by insulated pierceing
connectors through service connection box complete as required & directed by Engineer in Charge.
Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM including fitting of all acessaries i.e. special design
3 9924000067 suspension / tension clamp, fixing of cross arm, binding to pin insulator,preparing shackle point,jumpers etc. KM
and inclusive of dismantling charge of existing bare conductor and crediting in to store complete as required &
directed by Engineer in Charge
Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM including fitting of all acessaries i.e. special design
4 99240000658 suspension / tension clamp, fixing of cross arm, binding to pin insulator,preparing shackle point,jumpers etc. KM
and inclusive of dismantling charge of existing bare conductor and crediting in to store complete as required &
directed by Engineer in Charge
Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM including fitting of all acessaries i.e. special
design suspension / tension clamp, fixing of cross arm, LT shackle insulator etc. for fixing of messenger wire and
5 9924000069 inclusive of dismantling charge of existing bare conductor and crediting in to store & dismentaling of service KM
line from LT bare conductor and to provide service connection on Aerial Bunch Cable by insulated pierceing
connectors through service connection box complete as required & directed by Engineer in Charge.
( D )LAYING OF 11 KV MVCC
1 LAYING. TESTING & COMMISSIONING OF SPECIALLY DESIGNED 11 KV AL -59 ACS MEDIUM VOLTAGE COVERED CKM
CONDUCTOR AS PER THE TECHNICAL SPECIFICATIONS ( WITH ACCESSORIES )
2 LAYING,TESTING & COMMISSIONING OF SPECIALLY DESIGED 11KV 55 MM2 AAAC MEDIUM VOLTAGE COVERED CKM
CONDUCTOR AS PER THE TECHNICAL SPECIFICATIONS ( WITH ACCESSORIES)
(D)LABOUR RATE FOR UNDERGROUND CABLE WORK FOR FY 2024-25 (WITHOUT GST)
Sr. No. Item Code No. Description Unit Rate
Labour charge for excavation of cable trench of 400mm width x 1200mm depth, in any type of soil for laying of
1 9925000001 cable of size up to 240 mm2 (For additional cable 200 mm additional width shall be considered i.e. half trench Meter
length is to be considered
Labour charge for excavation of cable trench of 600mm width x 1200mm depth, in any type of soil for laying of
2 9925000002 cable of size up to 240 mm2 (For additional cable 200 mm additional width shall be considered i.e. half trench Meter
length is to be considered
Labour charge for excavation of cable trench of 400mm width x 1500mm depth, in any type of soil for laying of
3 9925000003 cable of size up to 240 mm2 (For additional cable 200 mm additional width shall be considered i.e. half trench Meter
leng th is to be considered
Labour charge for laying of 11kV / 22 kV XLPE Cable of size up to 240 mm2 & preparation of sand layer 100mm
thick, in the cable trench & covering the cable with 150 mm dia (Outer), thickness 25 mm, 1.0 meter long RCC
4 9925000004 half round muffs and providing and fixing of 4inch width yellow colour polyethylene tape with Meter
printing"CAUTION ELECTRIC CABLE BELOW' at 0.75 m depth from ground surface after laying cable in trench.
This will provide indication that electric cable is passing underground so as to protect cable from mechanical
injuries, refilling the same, as per Instruction of E gineer in Charge (EIC) .
Labour charge for horizontal drilling using Auger machine without damage to surface road at max 2.0 mtrs
depth & putting of 6.11 kg/cm2 , class-4,Green color, 110mm 0.D. 8.5mm thickness H.D.P.E. pipe confirms to IS
4984-1987(3rd revision) and BIS certification and laying of 11KV/22KV XLPE cable of size up to 240 mm2 in
5 9925000005 HDPE pipe, as per Site Condition (excluding cost of pipe). The detail map obtained from HDD machine and excel Meter
sheet hard and soft copy) indicating the respective depth and distance from adjacent landmark for each
segment for HDD is must require to be submitted. HDD to be carried out at depth 1.5 mtrs to 2.0 mtrs as per
site conditions and as er instruction of EIC.
Labour charge for horizontal drilling manually without damage to surface road at max 2.0 mtrs depth & putting
of 6.11 kg/cm2 , class-4,Green color, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe confirms to IS 4984-1987(3rd
revision) and BIS certification and laying of 11KV/22KV XLPE cable of size up to 240 mm2 size, as per Site
6 9925000006 Condition (excluding cost of pipe). The detail map and excel sheet (hard and soft copy) indicating the respective Meter
depth and distance from adjacent landmark for each segment of cable to be submitted. Drilling to be carried
out at depth Minimum 1.2 mtrs to 2.0 mtrs as per site conditions as per instruction of EIC.
7 9925000007 Supply of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5 mm thickness H.D.P.E. pipe confirms to IS 4984 Meter
and BIS certification for laying of underground 11KV/ 22KV XLPE cable up to 240 mm 2 size.
8 9925000008 Labour work for RCC concreting on disputed location and repairing of damage portion of road crossing for the CMT
work carried out for roads crossing as well as concreting & muffing of poles including all materials
Providing & fixing concrete stone route marker of 300 mm width x 150 mm thick x 650 mm height embedded in
earth at least 300 mm below & 350 mm above ground level respectively at distance approx. 50 meters along
the length of cable. The RCC concreting (1:2:4)(all necessary materials will be in bidder's scope) of route
9 9925000009 marker is to be carried out 300 mm width x 150 mm thick x 300 mm below ground level as per instruction of No
EIC. The route marker should be with name of company with approved yellow colour-DGVCL. The distance from
marker to cable and cable depth with feeder name etc., marked with arrow sign is to be painted on it. The
route marker is to be fixed at location near to any fixed permanent location (not necessary to fix exact on top of
cable) as per instruction of EIC.
Erection of D.P. (double pole) structure using 9 / 11 Mtr. RSJ pole with cable connection arrangement along
10 9925000010 with fitting of necessary fabrication for 11KV cable including excavation of pit & refilling of earth as per No
instruction of EIC. (Exclusive of concreting & muffing of poles)
Erection of Single pole structure using 9 / 11 Mtr RSJ pole with cable connection arrangement along with fitting
11 9925000011 of necessary fabrication for 11KV/22 KV cable including excavation of pit & refilling of earth as per instruction No
of EIC. (Exclusive of concreting & muffing of poles
Erection of D.P. (double pole) structure using 8.0 Mtr. PSC pole with cable connection arrangement along with
12 9925000012 fitting of necessary fabrication for 11KV cable including excavation of pit & refilling of earth as per instruction of No
EIC. (Exclusive of concreting & muffing of poles
Erection of Single pole structure using 8.0 Mtr PSC pole with cable connection arrangement along with fitting of
13 9925000013 necessary fabrication for 11KV/22 KV cable including excavation of pit & refilling of earth as per instruction of No.
EIC. (Exclusive of concreting& muffing of poles
Labour charge for erecting of 11kV / 22 kV XLPE cable of size up to 240 mm 2 on DP Structure with fixing of
14 9925000014 Nos polymer cleats on top and middle part. Polymer cleats, nut bolts etc. fixing material to be provided by perJob
Providing & fixing of 6.11kg/cm2 , class4,Green color, 110mm O.D. 8.5mm thickness H.D.P.E. pipe confirms to IS
4984 and BIS certification on the erected DP structure for the mechanical protection of cable by inserting the
15 9925000015 cable inside HDPE pipe. The HDPE pipe shall be erected in such a way that 300mm shall be below the ground perJob
level and the rest 2700 mm shall be supported on the DP Structure with 01 No Polymer cleat. All materials
including polymer cleat and Nut bolt to be provided by contractor.
Providing and fixing of pipe type earthing from 80 mm dia class-B GI pipe with pit to be filled with salt & coke
16 9925000016 and construction of chamber as per DGVCL Drg. No. dg /100 for DP and cable. The earthing pit should be joined No
with cable by G.I. strip of size 1" width & 2 mm thick. All material GI pipe, Coke Salt etc will be supplied by
17 9925000017 Supply & fixing of heat shrink type end terminations (outdoor) for up to 11kV 3C x 185 mm2 size XLPE cable as No
per DGVCL technical s ecification
18 9925000018 Supply & fixing of heat & shrinkable end terminations (outdoor) for up to 22 kV 3C x 185 mm 2 size XLPE cable No
( as per DGVCL technical specification)
19 9925000019 Supply & fixing of heat shrinkable type end terminations (indoor) for up to 11kV 3C x 185 mm 2 size XLPE cable No
as per DGVCL technical specification
20 9925000020 Supply & fixing of heat & shrinkable end terminations (indoor) for up to 22 kV 3C x 185 mm 2 size XLPE cable as No
per DGVCL technical specification
21 9925000021 Supply & fixing of heat shrinkable straight through joint for up to 11kV 3C x 185 mm 2 size XLPE cables as per No
DGVCL technical specification.
22 9925000022 Supply & fixing of heat shrinkable straight through joint type for up to 22kV 3C x 185 mm 2 size XLPE cable as No
per DGVCL technical specification
Labour charge for excavation of 2100mm long x 1200mm wide x 1200 mm deep joint pits for installation of
23 9925000023 11kV / 22kV Straight through joints as per instruction of engineer-in-charge & covering the cable with 150 mm No
dia (Outer), thickness 25 mm, 1.0 meter long RCC half round muffs & refilling same as per instruction of EIC .
Providing and fixing of insulating bus bar, made from 11KV/22KV XLPE cable after removal of semi conducting
layer and applying of PVC heat shrinkable antitracking core insulating tubing (1.1KV), on both end terminal
24 9925000024 using Aluminium long barrel heavy duty up to 240 sq mm lugs, Aluminium bus connector. Taping with PGclamp No
for bus conductor as per drawing and as per instruction of EIC. The Allurninium lugs and PG clamp shall be
covered with 11KV/22KV HT insulating tapes.(11KV/22KV XLPE cable will be in scope of DGVCL while all other
materials will be in bidder's scope.
25 9925000025 Testing of cable at various points and commissioning the feeder as per instruction of engineer-in-charge.Test No
result shall be submitted by contractor with bill.
26 9925000026 Preparation and submission of 6 (six) copies, of complete layout drawings with GIS mapping as per actual cable Set
routing showing road crossing, HDPE pipe sleeving, jointing locations, markers etc.
Providing and fixing of Sign Board at junction point Made out of 2 mm aluminium sheet size 750x300 mm (2.5 x
1 ft) rectangle, as per design, pretreated with phosphate process and acid etching coated with one coat of
epoxy primer and two coats of best quality paints, reflectorized with Hi Intensity retro — reflective sheeting as
27 9925000027 per the latest and frame fabricated from suitable size iron angle. The Sign Board is to be fixed on the base No
prepared from channel and bracing angles which is grouted by means of cement concreting of 1:2:4 for size of
300 mm dia x 800 mm height (500 mm to be grouted in ground). The details to be displayed on sign board will
be given by InchargeEngineer. (a) Hi intensity Micro prismatic Grade
Providing and fixing of Sign Board (Danger Board) on Distribution Transformer Centers Made out of 2mm
aluminium sheet size 300x300mm (1X1 ft) as per design, pre treated with phosphate process and acid etching
28 9925000028 coated with one coat of epoxy primer and two coats of best quality paints, reflectorized with Hi-Intensity No
retroreflective sheeting as per the latest and frame fabricated from suitable size iron angle. The Sign Board
(Danger Board is to be fixed at the location as per instruction of In-charge Engineer. (a) Hi intensity Micro
prismatic Grade
Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm (W) from 3 mm aluminium sheet along with
29 9925000029 mm dia aluminium binding wire for fixing of aluminium tag near end termination joint at DP structure for No
identifying the cable. The details of feeder i.e. 11 / 22 KV with feeder name should be punched on the tag by
letter punch of size 16 mm as per instruction of In-charge Engineer.
30 9925000030 Supply & fixing of heat shrink type end terminations (outdoor) for 11kV 3C x 240 mm2 size XLPE cable as per Nos
DGVCL technical specification.
31 9925000031 Supply & fixing of heat & shrinkable end terminations (outdoor) for 22 kV 3C x 240 mm2 size XLPE cable as per Nos
DGVCL technical specification
32 9925000032 Supply & fixing of heat shrink type end terminations (indoor) for 11kV 3C x 240 mm2 size XLPE cable as per Nos
DGVCL technical specification
33 9925000033 Supply & fixing of heat & shrinkable end terminations (indoor) for 22 kV 3C x 240 mm2 size XLPE cable as per Nos
DGVCL technical specification
34 9925000034 Supply & fixing of heat shrinkable straight through joint for 11kV 3C x 240 mm2 size XLPE cables as per DGVCL Nos
technical s ecification.
35 9925000035 Supply & fixing of heat shrinkable straight through joint type for 22kV 3C x 240 mm2 size XLPE cable as per Nos
DGVCL technical s ecification
Installation, Testing and commissioning of 11 KV,630 A SCADA Compatible, RRL type3 Way RMU including Two
36 9925000038 numbers of earthings as per Drawing (material is in bidder's scope) and as per DGVCL Technical specification. Nos
Installation, Testing and commissioning of 11 KV,630 A SCADA Compatible, RRLL type4 Way RMU including Two
37 9925000039 numbers of earthings as per Drawing (material is in bidder's scope) and as per DGVCL Technical specification. Nos
Installation, Testing and commissioning of 22KV,630 A SCADA Compatible, RRL type-3 Way, RMU including Two
38 9925000040 numbers of earthings as per Drawing (material is in bidder's scope) and as per DGVCL Technical specification. Nos
Installation, Testing and commissioning of 22KV,630 A SCADA Compatible, RRLL type-4 Way, RMU including
39 9925000041 Two numbers of earthings as per Drawing (material is in bidder's scope) and as per DGVCL Technical Nos
Construction of plinth for 11KV, RRL type- 3 Way( i.e Two numbers of Isolator & One number of Breaker) Ring
40 9925000042 Main Unit as per DGVCL's technical specification mentioned in drawing no: Drg. 11kv-01. All required material Nos
will be supplied by contractor.
Construction of plinth for 11KV, RRLL type4 Way (i.e Two numbers of Isolator & Two number of Breaker)Ring
41 9925000043 Main Unit as per DGVCL's technical specification mentioned in drawing no:Drg. 11kv-02.AlI required material Nos
will be supplied by contractor.
Construction of plinth for 22KV, RRL type- 3 Way (i.e Two numbers of Isolator & One number of Breaker) Ring
42 9925000044 Main Unit as per DGVCL's technical specification mentioned in drawing no: Drg. 22kv-01. All required material Nos
will be supplied by contractor.
Construction of plinth for 22KV, RRLL type4 Way (i.e Two numbers of Isolator & Two number of Breaker)Ring
43 9925000045 Main Unit as per DGVCL's technical specification mentioned in drawing no:Drg. 22kv-02.All required material Nos
will be supplied by contractor.
Modifications e.g. Providing and fixing ofTerminal protectors i.e. Re-use able boot (HT Side 11/22KV, LT Side
1.1KV) including 11/22 KV insulating taps and L.T.(I.I KV) insulating taps ,Busbar, Tapping from Bus Bar (11/22
KV XLPE cable) through P.G. Clamp for H.T. Jumper to D.O. Fuse to bushings of Transformer Center, providing &
Fixing of jumper and providing & fixing of Heat Shrinkable Anti Tracking CoreInsulating Tubing (Insulation Level
44 9925000046 11/22 KV) in H.T. jumper , Clamping arrangement of cable support frame on both side of existing Over Head Nos.
type Distribution Transformer to utilize in Under Ground cable network as per drawing & as per instruction of
Engineer incharge. All live parts i.e. PGClamp, connections of D.O.fuses, HT bushings etc . shall be covered with
fixing of 11/22 KV HT insulating tapes. ( 11/22 KV XLPE cable will be in scope of DGVCL while all other materials
will be in bidder's scope )
45 9925000047 Laying of any size of 11/ 22 KV XLPE /PILCCable in readymade trench or in open space
46 9925000060 Labour charges for lying of O/H XLPE cable pole to pole KM
47 9925000064 Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 meter long RCC half round pipe NO
TOTAL ESTIMATE-TWO LAKH TEN THOUSAND ONLY
Note :- All Rates are Excluding of GST.
Executive Engineer (O&M),
D.G.V.C.L.,Vapi Rural Division.
1. DGVCL will provide key material like M.S. materials,ABC/Bare conductors,PSC/RSJ Poles,Insulators,Fabricated
materials etc. to the contractor.2.All fabricated items shall be fabricated as per DGVCL approved drawing and
by welding rods confirming to the relevent ISI specification and as directed by Engineer in charge.3.Necessary
electricity connection for fabrictated items shall be provided by DGVCL on payment of required charge for
connection & electricity bill of the same shall be paid by the agency.4.All the rates are inclusive of PF and
Exclusive of GST applicable time to time.5.All steel material are to be painted as below:(a) Scrubbing of rusted
surface properly before applying the paints on to the RSJ poles & steel fabricated materials of RSJ/PSC poles is
must required.(b) Two coats of approved ISI mark red oxide (primer) is to be properly painted for the RSJ poles
& steel fabricated materials of RSJ/PSC poles. (c) Two coats of approved ISI mark silver paint (i.e. triple mangoes
or equivalent quality silver paint) is to be properly painted on to the RSJ poles & steel fabricated materials of
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2.1 Notice.pdf
2.2 Integrity Part.pdf
2.4 Terms and condition.pdf
bank detail for Payment.pdf
Document.pdf
NEW Bid Document terms and condition.pdf
schedule-B.pdf
Download all tender documents and submit your bid