| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.7 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹69.6 L+₹7.9 L (12.9%)Rejected-Finance FALAH COMPLEX 9 10 PLAYANAGADI | KERALA | L2 | Rejected-Finance Being L2 |
Tender Value
₹73.1 L
EMD Value
₹50,000
Closing Date
7 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Joji Paul
EXECUTIVE ENGINEER LSGD DIVISION AYYANTHOLE THRISSUR 680 003
LAC ADS 2021-22 KUNNAMKULAM LA - KUNNAMKULAM POLICE STATION 2 ND FLOOR AND ADDITIONAL WORKS IN KUNNAMKULAM MUNICIPALITY
2022_LSGD_470535_36
TN-16/2021-22
Open Tender
Civil Works - Buildings
Item Rate
365 days
Thrissur
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
Yes
₹50,000
Yes
27 May 2022
31 Jan 2022
9 Feb 2022
31 Jan 2022
7 Feb 2022
31 Jan 2022
180 days
Amount
Police station buildng
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15<sup>0</sup> landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.2.2 : Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete
50.13.1 : 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
od1439231/2021_2022 : White Cement washing TWO coat including all labour, material, conveyance , scaffolding charges etc complete.
11.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
11.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
od1518994/2021_2022 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
11.38 : Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
21.1.1.1 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)
9.48.1 : Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
21.3.2 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness
50.9.1.2 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) using good quality Pincoda wood
od1441404/2021_2022 : Supplying and Fixing readymade Ferra door including all cost and conveyance, labour charges
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
od1441562/2021_2022 : Supplying and fixing 20mm thick ready made PVC door (85*210cm) with frame 50*42 mm including conveyance,cost of fitting , labour for fixing etc.<br>
10.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
17.2.2 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked black solid plastic seat and lid
17.7.2 : Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
od1441667/2021_2022 : Floor trap 110mm with steel cover
50.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2
50.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2
50.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
50.18.8.7.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
50.18.9.16.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall
50.18.9.17.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
od1443550/2021_2022 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, testing of joints complete as per direction of Engineer in Charge.90 mm dia 6 Kgf/ cm2
50.18.9.20.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl
50.18.9.21.7 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl
50.18.9.22.8 : Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
50.17.1.2 : Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.17.1.4 : Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
18.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
50.18.9.10.1 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
9.88 : Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
25.7 : Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
25.1 : Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
od1446138/2021_2022 : Designing, fabricating, testing, protection, installing and fixing in position semi<br>(grid) unitized system of structural glazing (with open joints) for linear as well as<br>curvilinear portions of the building for all heights and all levels, including:<br>a) Structural analysis & design and preparation of shop drawings for the specified<br>design loads conforming to IS 875 part III (the system must passed the proof test<br>at 1.5 times design wind pressure without any failure), including functional design<br>of the aluminum sections for fixing glazing panels of various thicknesses, aluminium<br>cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps<br>etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cumsmoke<br>seals, microwave cured EPDM gaskets for water tightness, pressure<br>equalisation & drainage and protection against fire hazard including:<br>b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of<br>6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3<br>Dimentional movement for achieving perfect verticality and fixing structural glazing<br>system rigidly to the RCC/ masonry/structural steel framework of building structure<br>using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic<br>contacts with nuts and washers etc. of stainless steel grade 316, of the required<br>capacity and in required numbers.<br>c) Providing and filling, two part pump filled, structural silicone sealant and one<br>part weather silicone sealant compatible with the structural silicone sealant of<br>required bite size in a clean and controlled factory / work shop environment ,<br>including double sided spacer tape, setting blocks and backer rod, all of approved<br>grade, brand and manufacture, as per the approved sealant design, within and all<br>around the perimeter for holding glass.<br>d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick<br>and of sizes, shapes and profiles, as required as per the site conditions, to seal the<br>gap between the building structure and all its interfaces with curtain glazing to<br>make it watertight.<br>e) Making provision for drainage of moisture/ water that enters the curtain glazing<br>system to make it watertight, by incorporating principles of pressure equalization,<br>providing suitable gutter profiles at bottom (if required), making necessary holes<br>of required sizes and of required numbers etc. complete. This item includes cost<br>of all inputs of designing, labour for fabricating and installation of aluminium grid,<br>installation of glazed units, T&P, scaffolding and other incidental charges including<br>wastages etc., enabling temporary structures and services, cranes or cradles etc.<br>as described above and as specified. The item includes the cost of getting all the<br>structural and functional design including shop drawings checked by a structural<br>designer, dully approved by Engineer-in-charge.<br>The item also includes the cost of all mock ups at site, cost of all samples of the<br>individual components for testing in an approved laboratory, field tests on the<br>assembled working structural glazing as specified, cleaning and protection till the<br>handing over of the building for occupation. In the end, the Contractor shall provide<br>a water tight structural glazing having all the performance characteristics etc. all<br>complete as required, as per the Architectural drawings, as per item description,<br>as specified, as per the approved shop drawings and as directed by the Engineerin-<br>Charge.<br>Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded<br>aluminium section capping for fixing in the grooves of the curtain glazing and<br>vermin proof stainless steel wire mesh shall be paid for separately under relevant<br>items under this sub-head. However, for the purpose of payment, only the actual<br>area of structural glazing (including width of grooves ) on the external face shall<br>be measured in sqm. up to two decimal places.<br>Note:-2. The following performance test are to be conducted on structural glazing<br>system if area of structural glazing exceeds 2500 Sqm from the certified laboratories<br>accreditated by NABL(National Accreditation Board for Testing and Calibration<br>Laboratories), Department of Science & Technologies, India. Cost of testing is<br>payable separately. The NIT approving authority will decide the necessity of testing<br>on the basis of cost of the work, cost of the test and importance of the work.<br>Performance Testing of Structural glazing system<br>Tests to be conducted in the NBL Certified laboratories<br>1. Performance Laboratory Test for Air Leakage Test (-50pa to – 300pa) & (+50pa to<br>+300pa) as per<br>ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”<br>2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing<br>method for a range up to 2000 ml.”<br>3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing<br>method for a range upto 2000 ml”<br>4. Structural Performance Deflection and deformation by static air pressure test<br>(1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing<br>method for a range upto 50 mm”<br>5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for<br>Qualitative test” Tests to be conducted on site<br>6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi)<br>upto 2000ml”
od1446139/2021_2022 : Providing, assembling and supplying vision glass panels (IGUs) comprising of<br>hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units<br>of size and shape as required and specified, comprising of an outer heat<br>strengthened float glass 6mm thick, of approved colour and shade with reflective<br>soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned<br>clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary<br>seal and secondary seal (structural silicone sealant) etc. all complete for the required<br>performances, as per the Architectural drawings, as per the approved shop<br>drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall<br>be assembled in the factory/ workshop of the glass processor. (Payment for fixing<br>of IGU Panels in the curtain glazing is included in cost of item No.26.2) For payment,<br>only the actual area of glass on face # 1 of the glass panels (excluding the areas of<br>the grooves and weather silicone sealant) provided and fixed in position, shall be<br>measured in sqm.<br>(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on<br>face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make<br>having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection<br>internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-<br>0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance<br>glass shall be decided by technical sanctioning authority as per the site requirement
APPENDIX 2
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
60.7.1 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
od1445297/2021_2022 : Drilling 150 mm dia DTH bore well vertically suitable to accommodate well pipe of 180 mm dia PVC Pipe<br>6 kg/ cm2 for various depth up to150 m below ground level, having over burden 20 m or more in all<br>classes of soil and rock inclusive of hire charge for machinery and all other accessories and stores<br>putting up temporary sheds, conveying , lowering the casing pipe,jointing with coupling , developing and<br>flushing continuously for 3 hours testing the discharge, , lowering dummy of the proposed Submersible<br>motor pump set in the drilled bore well assuring the free movement of the same , ceiling the casing pipe<br>in the rock with cement grout, providing temporary cap if necessary as per the direction of departmental<br>officers, including cost of fuel ,oil and other stores and all items incidental to the completion of work,<br>including conveyance of casing pipe,coupling and dummy etc. but excluding the cost of casing pipe and<br>specials etc. complete
od1445410/2021_2022 : Supply of 180 mm dia PVC pipe 6 kg/cm2 for<br>casing
od1445411/2021_2022 : Supplying and fixing 180mm end cap of first quality
od1445737/2021_2022 : Supplying and fixing 50 mm dia UPVC column pipe incuding all cost and conveyance
od1445738/2021_2022 : Supplying and fixing 4 mm 3 core cable including all cost and conveyance<br>
od1445773/2021_2022 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, testing of joints complete as per direction of Engineer in Charge.50 mm dia 6 Kgf/ cm2
18.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontal
18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
od1531045/2021_2022 : Roofing with G.I hard colour powder coated traffod sheets 0.5 mm thick or nearest available thickness with overlaps of 150 mm at ends and GI hook or crank C.I. bolts and nuts including plain washers and bitumen washers etc complete<br><br>
od1530988/2021_2022 : Supplying and fixing 150mm dia PVC half cut section with brackets at the end of sheet or tiled roof for rain water collection including all cost and materials, conveyance, labour charges etc. complete.<br>
od1530989/2021_2022 : Ridge capinging with pre painted galvenised steel sheets 0.5 mm thick 60 cm wide including all cost and materials, conveyance, labour charges etc. complete. <br>
od1443550/2021_2022 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, testing of joints complete as per direction of Engineer in Charge.90 mm dia 6 Kgf/ cm2
18.19.4.2 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreVertical
od1532801/2021_2022 : Interlocking Concrete Block Pavement<br><br>Providing and Laying of Interlocking Concrete Block Pavements having thickness 80 mm as per drawings and Technical Specification Clause 1504.
B2S DEVELOPERS
Bidder Name
K R PAULSON
B2S DEVELOPERS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_674693.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .